HG-SC111 [PANASONIC]

Contact-type Digital Displacement Sensor;
HG-SC111
型号: HG-SC111
厂家: PANASONIC    PANASONIC
描述:

Contact-type Digital Displacement Sensor

文件: 总18页 (文件大小:1832K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Contact-type Digital Displacement Sensor HG-S SERIES  
1094  
FIBER  
SENSORS  
LASER  
Superb craftsmanship!  
The accuracy and robustness of the HG-S series are backed by master craftsmanship.  
The plain bearings are accurately aligned with the center of the spindle during their installation to the top and  
bottom sections of the body to ensure smooth sliding.  
This process involves careful adjustment of each bearing by a skilled worker. Even though the plain bearing has  
a certain width, the clearance is managed to the accuracy of several μm.  
Those with experience in mechanisms design will know that this value signifies amazingly high control precision.  
SENSORS  
PHOTOELECTRIC  
SENSORS  
MICRO  
PHOTOELECTRIC  
SENSORS  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS /  
SAFETY COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
The high-precision, robust sensor is made possible by master craftsmanship.  
Maximize the high accuracy of our sensors in your pursuit of “ever higher levels of quality.ˮ  
PARTICULAR  
USE SENSORS  
Resistance to lateral load  
SENSOR  
OPTIONS  
Lateral loads often occur in the workplace, so we conduct our own unique lateral load resistance testing. There is a  
reason why you can use this product with peace of mind for a long time.  
SIMPLE  
WIRE-SAVING  
UNITS  
Lateral load  
resistance  
Withstands more than 100 million sliding operations under application of  
lateral load (typical value) (Note 1)  
WIRE-SAVING  
SYSTEMS  
No.1* in class  
As of June 2017,  
MEASUREMENT  
SENSORS  
*
Lateral load resistance test (Note 2)  
Example of a lateral load occurring in the workplace  
in-company survey.  
STATIC  
CONTROL  
DEVICES  
Lateral load is generated when the  
sensor is positioned at an angle or  
the workpiece becomes tilted.  
LASER  
MARKERS  
Lateral load  
PLC  
HUMAN MACHINE  
INTERFACES  
ENERGY  
Hitting the spindle laterally with a roller  
We conducted our own unique lateral  
load resistance testing  
MANAGEMENT  
SOLUTIONS  
Notes:  
1) Value on HG-S1010 /  
HG-S1110.  
FA COMPONENTS  
2) Button-type probe for  
evaluation purposes  
was installed on the test  
sample for the lateral  
load resistance test.  
<Test conditions>  
Impact cycle: 13 times per second  
Impact stroke: 1 mm 0.039 in  
MACHINE VISION  
SYSTEMS  
Measurement of workpiece not securely held by the jig  
UV CURING  
SYSTEMS  
Resistance to shock and vibration  
Shock resistance: 200 G approx.  
Vibration / shock  
resistance  
Vibration resistance: 20 G approx.  
10 to 500 Hz frequency  
(HG-S1032: 10 to 150 Hz frequency),  
3 mm 0.118 in double amplitude  
(Maximum acceleration 196 m/s2)  
in X, Y and Z directions for two hours each  
Selection  
Guide  
Laser  
Displacement  
Magnetic  
Displacement  
Contact  
Displacement  
Collimated  
Beam Sensors  
Metal-sheet  
Double-feed Detection  
1,960 m/s2 acceleration in X, Y and Z directions three  
times each  
No.1* in class  
As of June 2017,  
*
in-company survey.  
Resistant to upward thrust impact  
Hot-swappable  
Digital Panel  
Controller  
Spindle stopper installed at the lower section  
Change of sensor head without turning off the power supply  
Even if unexpected upward thrust occurs, the lower part  
of the spindle blocks the impact. Damage to the internal  
structure, including the glass scale, is minimized.  
The sensor head can be changed safely without turning off  
the controller. This reduces the man-hours required for the  
change of line setup for processing of different workpieces,  
thus achieving a significant reduction of setup change time.  
Other Products  
HG-S  
Spindle stopper  
Setup change  
hange of sens
gether with th
Jig for workpiece A  
Jig for workpiece B  
Contact-type Digital Displacement Sensor HG-S SERIES  
1095  
CONTROLLER  
FIBER  
SENSORS  
Versatile and easy-to-use controller  
LASER  
SENSORS  
The controller features the industry’s first* dual display and offers versatile functions and excellent ease of use.  
PHOTOELECTRIC  
SENSORS  
It allows simple and reliable operation of the advanced measurement function in a diversity of applications.  
* As a sensor product using optical absolute method, as of September 2015 (according to in-company survey)  
MICRO  
PHOTOELECTRIC  
SENSORS  
Dual display for added indication  
flexibility (equipped with NAVI fu
The 2-line digital display simultaneously
head measurement (measured value) a
judgment value (calculated value).  
High-speed response of 3 ms in  
combination with any sensor head  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS /  
SAFETY COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
Industry’s  
first!*  
INDUCTIVE  
PROXIMITY  
SENSORS  
All-direction LCD  
The high-contrast LC
clear indications and
PARTICULAR  
USE SENSORS  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
Equipped with intuitive circle meter  
Values between allowable maximum and  
minimum values are indicated in green. Valu
outside of the allowable range are indicated i
orange. This provides at-a-glance understan
of the margin to the tolerance limits.  
WIRE-SAVING  
SYSTEMS  
MEASUREMENT  
SENSORS  
STATIC  
CONTROL  
DEVICES  
LASER  
MARKERS  
Provided with maintenance mode  
useful on production floor  
PLC  
The following data are stored and can be  
used for analysis on the spot.  
HUMAN MACHINE  
INTERFACES  
Higher than  
maximum value  
Lower than  
minimum value  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Abnormal sensor head upward thrust value  
• Number of sensor head upward thrusts  
Cumulative total number of sliding operations  
Anytime selection of function to copy  
The selective copy function significantly redu
the man-hours required for initial setting and  
maintenance.  
FA COMPONENTS  
MACHINE VISION  
SYSTEMS  
Alarm setting for notification of  
upward thrust  
Alarm can be set to notify an upward  
thrust (stroke) that exceeds the set level.  
This allows you to conduct a preventive  
maintenance before the sensor head  
generates a malfunction.  
UV CURING  
SYSTEMS  
Selection  
Guide  
Laser  
Easy-to-understand 2-line digital display  
Displacement  
Magnetic  
Displacement  
Displa
The 2-line digital display simultaneously shows sensor head measurement and judgment value.  
Co
Beam S
Double-fee
Digita
Co
Sub-screen: Displays sensor head measurement  
and other data.  
Main screen:Displays judgment value.  
Other P
HG-S  
Easy tolerance setting  
Simple 1-point teaching  
Align with master workpiece and press ENTER key for easy tolerance setting.  
Tolerance on positive side (HIGH set value)  
Reference value  
Tolerance on negative side (LOW set value)  
One push!  
Tolerance setting completed!  
Master workpiece  
Contact-type Digital Displacement Sensor HG-S SERIES  
1096  
No need for trigger input  
FIBER  
SENSORS  
Equipped with self-trigger hold function  
Easy setting of time length from measurement start to measurement stabilization.  
LASER  
SENSORS  
Minimizes measurement fluctuation due to the vibration caused by stopping of spindle rotation.  
PHOTOELECTRIC  
SENSORS  
MICRO  
PHOTOELECTRIC  
SENSORS  
High  
AREA  
SENSORS  
Static width  
(1) Static width setting  
SAFETY LIGHT  
Stability range above the ST level can be set as desired.  
Set the range where measurements are considered to be stable.  
Low  
CURTAINS /  
SAFETY COMPONENTS  
ST  
level  
PRESSURE /  
FLOW  
SENSORS  
(2) Delay timer setting  
Delay timer  
INDUCTIVE  
PROXIMITY  
SENSORS  
Desired delay time after measurement exceeding the ST level can be set.  
Set the time required for stabilization of measurement.  
Time  
PARTICULAR  
USE SENSORS  
Lateral connection of slave units for added operational ease  
SENSOR  
OPTIONS  
Connection of up to 15 slaves units  
SIMPLE  
WIRE-SAVING  
UNITS  
One master unit can be connected with up to 15 slave units in any order. This allows easy multi-point calculations.  
(Example: Connection of 15 slave units)  
WIRE-SAVING  
SYSTEMS  
Controller variations  
MEASUREMENT  
SENSORS  
■ Master unit (1 model)  
• High performance type  
analog current + input /  
■ Slave unit (3 models)  
High performance type  
STATIC  
CONTROL  
DEVICES  
(analog current + input / output)  
Standard type (input / output)  
(
)
output  
LASER  
MARKERS  
• Wire-saving type  
Hold function (9 types)  
PLC  
Sample hold (S-H)  
Peak hold (P-H)  
Bottom hold (B-H)  
Master unit  
High performance type  
(analog current + input / output) (analog current + input / output) (input / output)  
HG-SC101  
Slave unit  
High performance type  
Slave unit  
Slave unit  
Wire-saving type  
HG-SC113  
Peak-to-peak hold (P-P)  
NG hold (NG-H)  
Peak-to-peak hold/2 (P-P/2)  
Self-sample hold (SLF.S-H)  
Self-bottom hold (SLF.B-H)  
HUMAN MACHINE  
INTERFACES  
Standard type  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Self-peak hold (SLF.P-H)  
HG-SC111  
HG-SC112  
End plates  
MS-DIN-E  
Calculation function (8 types)  
FA COMPONENTS  
MAX (maximum value) MIN (minimum value) FLAT (flatness) AVERAG (average value)  
* End plates (optional) must be mounted on both sides of the controller  
after the connection of slave units.  
MACHINE VISION  
SYSTEMS  
STAND (reference difference) TORSIN (torsion) CURVEA (curvature) THICK (thickness)  
UV CURING  
SYSTEMS  
Selection  
Guide  
Laser  
Displacement  
Magnetic  
Displacement  
Contact  
Displacement  
Collimated  
Beam Sensors  
Metal-sheet  
Double-feed Detection  
Digital Panel  
Controller  
Other Products  
HG-S  
Contact-type Digital Displacement Sensor HG-S SERIES  
1097  
COMMUNICATION UNIT FOR DIGITAL DISPLACEMENT SENSOR  
FIBER  
SENSORS  
Directly send the measurement values of multiple sensors to a host!  
Communication unit for CC-Link IE Field / CC-Link  
LASER  
SENSORS  
PHOTO-  
ELECTRIC  
SENSORS  
MICRO  
PHOTO-  
Communication unit for CC-Link IE Field  
Communication Unit for CC-Link  
ELECTRIC  
SENSORS  
SC-HG1-CEF  
SC-HG1-C  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS /  
SAFETY  
COMPONENTS  
Communication speed: 1 Gbps  
iQSS support is planned  
Communication speed: 10 Mbps (max.)  
Supports iQSS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
The communication unit can be used  
to connect directly to a CC-Link  
network. This lets you acquire digital  
data and ON / OFF information in  
real-time without a program.  
Cloud server  
Equipment maintenance  
and management  
Production execution  
system  
PARTICULAR  
USE  
SENSORS  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
Production instruction  
terminal  
PLC  
Display  
In addition, you can change  
controller settings and log  
WIRE-SAVING  
SYSTEMS  
measurement data via the CC-Link  
network, so you can also use the  
system for preventative maintenance  
of digital displacement sensors.  
MEASURE-  
MENT  
SENSORS  
STATIC  
CONTROL  
DEVICES  
Hub  
PLC Local  
PLC Master  
PLC Master  
LASER  
MARKERS  
PLC  
HUMAN  
MACHINE  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
FA  
COMPONENTS  
High-precision data  
High-precision data  
SC-HG1-CEF  
SC-HG1-C  
SC-HG1-C  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
SYSTEMS  
High-precision data  
High-precision data  
SC-HG1-CEF  
Selection  
Guide  
Connection of 1 master unit and up to 14 slave units (Note)  
Note: When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit  
Connection of 1 master unit and up to 14 slave units (Note)  
Laser  
Displacement  
Magnetic  
Displacement  
Contact  
Displacement  
Communication unit for RS-485  
Collimated  
Beam  
Sensors  
Programmable  
Controller  
Communication unit for RS-485  
Metal-sheet  
Double-feed  
Detection  
SC-HG1-485  
SERIES  
FP7  
SC-HG1-485  
Digital Panel  
Controller  
RS-485 communication  
Other  
Products  
Ethernet  
Web server  
Communication speed: 1.2 kbps / 2.4 kbps / 4.8 kbps / 9.6 kbps /  
HG-S  
19.2 kbps / 38.4 kbps / 57.6 kbps / 115.2 kbps  
For use of high-precision measurement results  
as traceability data examples. Transfers not only  
measurements results obtained at multiple points  
but also setting statuses as digital data in a batch.  
Analysis, cause investigation, etc.  
Data logging, etc.  
Provides powerful support to the management  
of inspection records and identification of failure  
Connection of 1 master unit  
and up to 14 slave units (Note)  
RS-485 communication protocol  
causes.  
MODBUS (RTU / ASCII): Connection of up to 99 stations  
MEWTOCOL-COM: Connection of up to 64 stations  
Note: When connected to a communication unit for digital  
displacement sensor, up to 14 slave units can be  
connected per master unit.  
Contact-type Digital Displacement Sensor HG-S SERIES  
1098  
APPLICATIONS  
FIBER  
SENSORS  
AUTOMOTIVE APPLICATIONS  
OTHER APPLICATIONS  
LASER  
SENSORS  
PHOTO-  
Coupling aspection  
Crankshaft dimension measurement  
Transmission parts height measurement  
Installed height measurement  
Motor shaft eccentricity measurement  
X-Y stage position measurement  
Tablet surface flatness measurement  
Resin roller eccentricity measurement  
ELECTRIC  
SENSORS  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE  
SENSORS  
SENSOR  
OPTIONS  
Screw head height measurement  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
SENSORS  
STATIC  
CONTROL  
DEVICES  
LASER  
MARKERS  
PLC  
HUMAN  
MACHINE  
INTERFACES  
Automotive parts dimension measurement  
ENERGY  
MANAGEMENT  
SOLUTIONS  
FA  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
SYSTEMS  
Selection  
Guide  
Laser  
Management of press-fit points of press-fit parts  
Displacement  
Magnetic  
Displacement  
Contact  
Displacement  
Collimated  
Beam  
Sensors  
Contact-type displacement  
Metal-sheet  
Double-feed  
Detection  
sensor and load cell are used  
to manage pressure change  
point and stroke position for the  
confirmation of proper press-fit  
mounting.  
Digital Panel  
Controller  
Other  
Products  
HG-S  
Contact-type Digital Displacement Sensor HG-S SERIES  
1099  
FIBER  
ORDER GUIDE  
SENSORS  
LASER  
SENSORS  
Sensor heads  
PHOTO-  
ELECTRIC  
SENSORS  
Measurement  
range  
Type  
Appearance  
Resolution  
Model No.  
HG-S1010  
HG-S1010R  
HG-S1110  
HG-S1110R  
HG-S1032  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
General purpose  
Standard  
AREA  
General  
purpose  
0.5 μm  
0.020 mil  
SENSORS  
32 mm  
1.260 in  
type  
SAFETY LIGHT  
CURTAINS /  
SAFETY  
Low measuring  
force  
High precision  
10 mm  
0.394 in  
type  
COMPONENTS  
10 mm  
0.394 in  
PRESSURE /  
FLOW  
10 mm  
0.394 in  
type  
Standard  
10 mm  
0.394 in  
type  
SENSORS  
High  
0.1 μm  
0.004 mil  
INDUCTIVE  
PROXIMITY  
SENSORS  
precision  
Low measuring  
force  
PARTICULAR  
USE  
SENSORS  
32 mm  
1.260 in  
type  
General  
purpose  
32 mm  
1.260 in  
0.5 μm  
0.020 mil  
SENSOR  
OPTIONS  
Standard  
SIMPLE  
WIRE-SAVING  
UNITS  
Sensor head connection cables (bending-resistant type)  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
Type  
Appearance  
Cable length  
Model No.  
CN-HS-C3  
SENSORS  
STATIC  
CONTROL  
DEVICES  
3 m  
9.843 ft  
LASER  
MARKERS  
Straight  
7 m  
CN-HS-C7  
connector  
22.966 ft  
PLC  
20 m  
65.617 ft  
HUMAN  
MACHINE  
CN-HS-C20  
CN-HS-C3L  
CN-HS-C7L  
CN-HS-C20L  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
3 m  
9.843 ft  
FA  
COMPONENTS  
L-shaped  
connector  
7 m  
22.966 ft  
MACHINE  
VISION  
SYSTEMS  
20 m  
65.617 ft  
UV  
CURING  
SYSTEMS  
Controllers  
Maximum number of  
connectable  
controllers  
Selection  
Guide  
Type  
Appearance  
Model No.  
Output  
Laser  
Displacement  
NPN  
open-collector  
transistor  
Magnetic  
Displacement  
High performance type  
HG-SC101  
Contact  
analog current  
+
input / output  
Master  
unit  
Displacement  
Collimated  
PNP  
open-collector  
transistor  
Beam  
Sensors  
HG-SC101-P  
HG-SC111  
Metal-sheet  
Double-feed  
Detection  
Digital Panel  
Controller  
NPN  
open-collector  
transistor  
High performance type  
Other  
Products  
analog current  
+
input / output  
PNP  
open-collector  
transistor  
HG-SC111-P  
HG-SC112  
HG-S  
Up to 15 slave units can  
be connected per  
master unit (Note)  
NPN  
open-collector  
transistor  
Slave  
units  
Standard type  
(input / output)  
PNP  
open-collector  
transistor  
HG-SC112-P  
Wire-saving type  
HG-SC113  
Note: When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.  
Contact-type Digital Displacement Sensor HG-S SERIES  
1100  
ORDER GUIDE  
FIBER  
SENSORS  
LASER  
SENSORS  
Communication units for digital displacement sensors  
PHOTO-  
ELECTRIC  
SENSORS  
Designation  
Appearance  
Model No.  
Description  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
Can directly send high-precision measurement values to a CC-Link IE Field host device.  
• Communication method  
CC-Link IE Field  
AREA  
Communication  
unit for  
CC-Link IE Field  
SENSORS  
SC-HG1-CEF  
• Number of connected units  
Host (CC-Link IE Field): Max. 121 units (1 master station, 120 slave stations)  
Controllers: Maximum of 15 units (1 master, 14 slaves) per SC-HG1-CEF unit  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
COMPONENTS  
PRESSURE /  
FLOW  
Can directly send high-precision measurement values to CC-Link Master.  
• Communication method  
SENSORS  
Switchable CC-Link Ver.1.10 or 2.00  
• Number of occupied station  
CC-Link Ver.1.10: 4 stations, CC-Link Ver.2.00: Switchable 2 or 4 stations  
• Number of connected units  
Controllers: Maximum of 15 units (1 master, 14 slaves) per SC-HG1-C unit  
INDUCTIVE  
PROXIMITY  
SENSORS  
Communication  
unit for CC-Link  
SC-HG1-C  
PARTICULAR  
USE  
SENSORS  
Can directly send high-precision measurement values by RS-485 communication  
• Communication protocol  
SENSOR  
OPTIONS  
MODBUS (RTU / ASCII) / MEWTOCOL-COM  
• Number of connected units  
Host (RS-485): 1 to 99 units when MODBUS (RTU / ASCII) is used, 1 to 64 units  
when MEWTOCOL-COM is used  
Controllers: Maximum of 15 units (1 master, 14 slaves) per SC-HG1-485 unit  
Communication  
unit for RS-485  
SIMPLE  
SC-HG1-485  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
End plates  
SENSORS  
STATIC  
CONTROL  
DEVICES  
Designation  
Appearance  
Model No.  
Description  
LASER  
MARKERS  
MS-DIN-E  
2 pcs. per set  
Always use this when connecting controllers and a digital  
displacement sensor communication unit.  
End plates  
PLC  
HUMAN  
MACHINE  
INTERFACES  
OPTIONS  
ENERGY  
MANAGEMENT  
SOLUTIONS  
FA  
Options (made-to-order)  
COMPONENTS  
MACHINE  
VISION  
Designation  
Appearance  
Model No.  
Description  
Standard type  
SYSTEMS  
UV  
CURING  
SYSTEMS  
TR-S10-C×5  
5 pcs. per set  
Super-hard type  
TR-S10-H  
TR-S321-H  
TR-S411-K  
TR-S601  
TR-J102  
Selection  
Guide  
Laser  
Displacement  
Probe  
Super-hard needle type  
Flat-seated type  
Magnetic  
Displacement  
Contact  
Displacement  
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Digital Panel  
Controller  
Roller type  
Other  
Products  
Length 15 mm 0.591 in type  
Length 25 mm 0.984 in type  
HG-S  
Joint  
TR-J104  
TR-G20×5  
5 pcs. per set  
Rubber bellows  
Computer  
software for  
CC-Link /  
This software makes it possible to use a computer to monitor current sensor values, save  
setting information to a CSV file, display log data, save log data to a CSV file, etc.  
Applicable models: SC-HG1-C, SC-HG1-CEF, SC-GU3-01 and SC-GU3-04 (Note)  
SC-PC1  
CC-Link IE Field  
Note: For SC-GU3-01 and SC-GU3-04, refer to the communication unit for open network SC-GU3 series (p.971~).  
Contact-type Digital Displacement Sensor HG-S SERIES  
1101  
FIBER  
SPECIFICATIONS  
SENSORS  
LASER  
SENSORS  
Sensor heads  
PHOTO-  
ELECTRIC  
SENSORS  
10 mm 0.394 in type  
32 mm 1.260 in type  
General purpose  
Standard  
Type  
General purpose  
Standard Low measuring force  
HG-S1010R  
High precision  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
Standard  
HG-S1110  
Low measuring force  
AREA  
Model No.  
HG-S1010  
HG-S1110R  
HG-S1032  
Item  
SENSORS  
CE marking directive compliance  
Compatible controller  
Position detection method  
Measurement range  
Stroke  
EMC Directive, RoHS Directive  
SAFETY LIGHT  
CURTAINS /  
SAFETY  
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113  
Optical absolute linear encoder method  
10 mm 0.394 in  
COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
32 mm 1.260 in  
INDUCTIVE  
PROXIMITY  
SENSORS  
10.5 mm 0.413 in or more  
32.5 mm 1.280 in or more  
PARTICULAR  
USE  
Downward  
mount  
1.65 N or less  
1.10 N (Note 3)  
0.35 N or less  
0.30 N (Note 3)  
1.65 N or less  
1.10 N (Note 3)  
0.35 N or less  
0.30 N (Note 3)  
2.97 N or less  
1.90 N (Note 3)  
SENSORS  
Measuring  
force  
(Note 2)  
SENSOR  
OPTIONS  
1.35 N or less  
0.85 N (Note 3)  
1.35 N or less  
0.85 N (Note 3)  
2.09 N or less  
1.19 N (Note 3)  
Upward mount  
Side mount  
──  
──  
SIMPLE  
WIRE-SAVING  
UNITS  
1.50 N or less  
0.95 N (Note 3)  
0.25 N or less  
0.20 N (Note 3)  
1.50 N or less  
0.95 N (Note 3)  
0.25 N or less  
0.20 N (Note 3)  
2.53 N or less  
1.50 N (Note 3)  
WIRE-SAVING  
SYSTEMS  
Resolution  
0.5 μm 0.020 mil  
0.1 μm 0.004 mil  
0.5 μm 0.020 mil  
Sampling period  
1 ms  
MEASURE-  
MENT  
SENSORS  
Full range: 2.0 μm 0.079 mil or less  
Narrow range: 1.0 μm 0.039 mil or less  
(any 60 μm 2.362 mil)  
Full range: 1.0 μm 0.039 mil or less  
Narrow range: 0.5 μm 0.020 mil or less  
(any 60 μm 2.362 mil)  
Full range: 3.0 μm 0.118 mil or less  
Narrow range: 2.0 μm 0.079 mil or less  
(any 60 μm 2.362 mil)  
STATIC  
CONTROL  
DEVICES  
Indication accuracy (P-P)  
Tip deviation amount  
Hot swap function  
Operation indicator  
Protection  
35 μm 1.378 mil (typical) (Note 4)  
40 μm 1.575 mil (typical) (Note 4)  
LASER  
MARKERS  
Incorporated  
PLC  
2-color LED (Orange / Green)  
IP67 (IEC) (Note 5)  
HUMAN  
MACHINE  
IP67 (IEC) (Note 5)  
──  
──  
IP67 (IEC) (Note 5)  
INTERFACES  
Ambient temperature  
Ambient humidity  
Insulation resistance  
-10 to +55 °C +14 to +131 °F (No condensation or icing allowed), Storage: -20 to +60 °C -4 to +140 °F  
35 to 85 % RH, Storage: 35 to 85 % RH  
ENERGY  
MANAGEMENT  
SOLUTIONS  
100 MΩ or more at 250 V DC  
FA  
COMPONENTS  
10 to 500 Hz frequency (HG-S1032: 10 to 150 Hz frequency), 3 mm 0.118 in double amplitude (Maximum acceleration  
Vibration resistance  
196 m/s2) in X, Y and Z directions for two hours each  
MACHINE  
VISION  
SYSTEMS  
Shock resistance  
Mounting nut tightening strength  
Probe tightening torque  
Grounding method  
1,960 m/s2 acceleration in X, Y and Z directions three times each  
UV  
CURING  
SYSTEMS  
12.5 N·m  
15 N·m  
0.1 to 0.4 N·m (no force applied to main unit)  
Capacitor grounding  
Body: Zinc (HG-S1032: Aluminum), Holder: Stainless steel, Spindle: Tool steel (HG-S1032: Free-cutting steel),  
Probe (Note 6): Ceramic, Rubber bellows: NBR (black)  
Selection  
Guide  
Material  
Laser  
Displacement  
Weight  
Net weight: 80 g approx.  
Net weight: 150 g approx.  
Magnetic  
Displacement  
Standard type (HG-S1010 / HG-S1110 / HG-S1032): Sensor head fastening wrench 1 pc., Mounting nut 1 pc.  
Low measuring force type (HG-S1010R / HG-S1110R): Sensor head fastening wrench 1 pc., Mounting nut 1 pc., Rubber bellows 1 pc.  
Accessories  
Contact  
Displacement  
Collimated  
Beam  
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were as follows: standard type measurement probe (TR-S10-C),  
ambient temperature +20 °C +68 °F, and a clean atmosphere where dust and liquids such as water and oil do not come in contact with the equipment.  
2) In the case of low measurement force type (HG-S1010R / HG-S1110R), measurements were obtained with products in standard configuration without  
rubber bellows.  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Digital Panel  
Controller  
3) Typical value near center of measurement.  
4) Value calculated from the clearance of the upper and lower plain bearings.  
5) Excludes damage and deterioration to rubber bellows due to external causes.  
Other  
Products  
6) The probes (optional) are also available.  
HG-S  
Contact-type Digital Displacement Sensor HG-S SERIES  
1102  
SPECIFICATIONS  
FIBER  
SENSORS  
LASER  
SENSORS  
Controller  
PHOTO-  
Master unit  
High-performance type  
HG-SC101  
Slave unit  
ELECTRIC  
SENSORS  
Type  
High-performance type  
HG-SC111  
Standard type  
HG-SC112  
Wire-saving type  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
NPN output  
PNP output  
HG-SC113  
Item  
HG-SC101-P  
HG-SC111-P  
HG-SC112-P  
AREA  
SENSORS  
CE marking directive compliance  
Compatible sensor head  
Number of connectable units  
Supply voltage  
EMC Directive, RoHS Directive  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
HG-S1010(R), HG-S1110(R), HG-S1032  
Up to 15 slave units can be connected per master unit. (Note 2)  
24 V DC ±10 %, including ripple 0.5 V (P-P)  
COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
Current consumption (Note 3)  
70 mA or less (when sensor head is connected)  
Current output range: 4 to 20 mA/F.S. (default value)  
Error output: 0 mA  
PARTICULAR  
USE  
Analog current output (Note 4)  
Linearity: ±0.25 % F.S.  
SENSORS  
Load impedance: 250 Ω max.  
SENSOR  
OPTIONS  
<NPN output type>  
<PNP output type>  
NPN open-collector transistor  
• Maximum sink current: 50 mA (Note 5)  
• Applied voltage: 30 V DC or less  
(between output and 0 V)  
• Residual voltage: 1.5 V or less  
(at 50 mA sink current)  
PNP open-collector transistor  
• Maximum source current: 50 mA (Note 5)  
• Applied voltage: 30 V DC or less  
(between output and +V)  
• Residual voltage: 1.5 V or less  
(at 50 mA source current)  
SIMPLE  
WIRE-SAVING  
UNITS  
Control outputs  
(Output 1, Output 2, Output 3)  
WIRE-SAVING  
SYSTEMS  
• Leakage current: 0.1 mA or less  
• Leakage current: 0.1 mA or less  
MEASURE-  
MENT  
SENSORS  
Short-circuit protection  
Judgment output  
Alarm output  
Incorporated (automatic reset type)  
STATIC  
NO / NC switching method  
Open when alarm occurs  
CONTROL  
DEVICES  
LASER  
<NPN output type>  
<PNP output type>  
MARKERS  
Non-contact input or  
Non-contact input or  
NPN open-collector transistor  
• Input condition:  
Invalid (+8 V to +V DC or open)  
Valid (0 to +1.2 V DC)  
PNP open-collector transistor  
• Input condition:  
Invalid (0 to +0.6 V DC or open)  
Valid (+4 V to +V DC)  
PLC  
External inputs  
(Input 1, Input 2, Input 3)  
HUMAN  
MACHINE  
INTERFACES  
Input impedance: 10 kΩ approx.  
Input impedance: 10 kΩ approx.  
ENERGY  
Trigger input  
Preset input  
Input time 2 ms or more (ON)  
MANAGEMENT  
SOLUTIONS  
Input time 20 ms or more (ON)  
Input time 20 ms or more (ON)  
Input time 20 ms or more (ON)  
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type  
204-segment LCD  
FA  
COMPONENTS  
Reset input  
Bank input A / B (Note 6)  
Response time  
Digital display  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
SYSTEMS  
Display resolution  
Display range  
0.1 μm 0.004 mil  
-199.9999 to 199.9999 mm -7.874 to 7.874 in  
2
Contamination level  
Elevation  
2,000 m 6561.68 ft or less (Note 7)  
IP40 (IEC)  
Selection  
Guide  
Protection  
Laser  
Displacement  
Ambient temperature  
Ambient humidity  
Voltage withstandability  
Insulation resistance  
Vibration resistance  
Shock resistance  
Material  
-10 to +50 °C +14 to +122 °F (No dew condensation or icing allowed) (Note 5), Storage: -20 to +60 °C -4 to +140 °F  
35 to 85 % RH, Storage: 35 to 85 % RH  
Magnetic  
Displacement  
Contact  
Displacement  
1,000 V AC for one min. between all supply terminals connected together and enclosure  
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure  
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (Maximum acceleration 49 m/s2) in X, Y and Z directions for two hours each  
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Digital Panel  
Controller  
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each  
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal  
0.2 mm2 2-core cable (brown and  
Other  
Products  
0.15 mm2, 7-core composite  
cable, 2 m 6.562 ft long  
0.15 mm2, 6-core cabtyre  
cable, 2 m 6.562 ft long  
Cable  
blue lead wires) / 0.15 mm2 7-core  
composite cable, 2 m 6.562 ft long  
HG-S  
Weight  
Net weight: 140 g approx.  
Net weight: 140 g approx.  
Net weight: 130 g approx.  
Net weight: 60 g approx.  
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 °C +68 °F.  
2) When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.  
3) Current consumption does not include analog current output.  
4) Linearity F.S. = 16 mA, and is linearity with respect to digitally measured values.  
5) When slave units are connected to the master unit, the maximum sink current / source current of the control output and ambient temperature vary  
depending on the number of connected slave units as shown below.  
Number of connected slave units  
1 to 7 units  
Maximum sink current / source current of control output  
Ambient temperature  
20 mA  
10 mA  
-10 to +45 °C +14 to +113 °F  
8 to 15 units  
6) Banks 1 to 3 can be selected by switching bank input A / B.  
7) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.  
Contact-type Digital Displacement Sensor HG-S SERIES  
1103  
FIBER  
SPECIFICATIONS  
SENSORS  
Communication units for digital displacement sensors  
LASER  
SENSORS  
Designation  
Model No.  
Communication unit for CC-Link IE Field  
SC-HG1-CEF  
Designation  
Model No.  
Communication unit for CC-Link  
SC-HG1-C  
PHOTO-  
ELECTRIC  
SENSORS  
Item  
Item  
CE marking directive compliance  
EMC Directive, RoHS Directive  
CE marking directive compliance  
EMC Directive (Note 2), RoHS Directive  
MICRO  
PHOTO-  
Compatible controllers  
Maximum number of  
connectable controllers  
Supply voltage (Note 2)  
Current consumption  
Communication method  
Remote station type  
Compatible controllers  
Maximum number of  
connectable controllers  
Supply voltage (Note 3)  
Current consumption  
Communication method  
Remote station type  
HG-SC□  
HG-SC□  
ELECTRIC  
SENSORS  
Maximum of 15 controllers  
(one master, 14 slaves) per SC-HG1-CEF unit  
24 V DC ±10%, including ripple 0.5 V (P-P)  
200 mA or less  
Maximum of 15 controllers  
(one master, 14 slaves) per SC-HG1-C unit  
24 V DC ±10 %, including ripple 0.5 V (P-P)  
80 mA or less  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS /  
SAFETY  
CC-Link IE Field  
Remote device station  
Switchable CC-Link Ver.1.10 or 2.00  
Remote device station  
COMPONENTS  
Network No.  
setting  
Cyclic transmission  
(Maximum number of  
links per station)  
Transient transmission  
Station No.setting  
Baud rate  
1 to 239 (decimal) [1 to EF (hex)]  
(0 and 240 or more: Error) (Note 3)  
Number of  
CC-Link Ver.1.10: 4 stations, CC-Link Ver.2.00:  
Switchable 2 or 4 stations  
PRESSURE /  
FLOW  
occupied station  
SENSORS  
Station No. setting  
Baud rate  
Maximum  
transmission distance 328.084 ft  
Pollution degree  
Operating altitude  
Protection  
Ambient  
temperature  
Ambient humidity  
Voltage  
withstandability  
Insulation  
resistance  
Vibration  
resistance  
Shock  
resistance  
Material  
Communication cable  
Weight  
1 to 64 (0 and 65 or more: Error)  
RX / RY128 points each (128 bits), 16 bytes  
INDUCTIVE  
PROXIMITY  
SENSORS  
10 Mbps  
100 m  
5 Mbps  
160 m  
2.5 Mbps  
400 m  
625 kbps  
900 m  
156 kbps  
1,200 m  
RWr / RWw64 points each (64 words), 128 bytes  
Server function only, data size 1,024 bytes  
1 to 120 (decimal) (0 and 121 or more: Error)  
1 Gbps  
524.934 ft 1,312.336 ft 2,952.756 ft 3,937.008 ft  
PARTICULAR  
USE  
2
SENSORS  
2,000 m 6561.680 ft or less (Note 4)  
IP40 (IEC)  
-10 to +45 °C +14 to +113 °F (No dew condensation or  
icing allowed), Storage: -20 to +60 °C -4 to +140 °F  
35 to 85 % RH, Storage: 35 to 85 % RH  
1,000 V AC for one min. between all supply terminals  
connected together and enclosure  
Transmission line types Line, star (mixing of line and star types is possible), ring  
SENSOR  
OPTIONS  
Maximum  
100 m 328.084 ft  
transmission distance  
SIMPLE  
WIRE-SAVING  
UNITS  
Maximum number of  
121 units (1 master station, 120 slave stations)  
connectable units  
Cascade connection levels  
Pollution degree  
Operating altitude  
Protection  
Ambient  
temperature  
Ambient humidity  
Voltage  
withstandability  
Insulation  
resistance  
Vibration  
resistance  
Shock  
resistance  
Material  
Maximum 20  
WIRE-SAVING  
SYSTEMS  
2
20 MΩ or more, with 250 V DC megger between all supply  
terminals connected together and enclosure  
2,000 m 6561.680 ft or less (Note 4)  
IP40 (IEC)  
-10 to +45 ºC +14 to +113 °F (No dew condensation or  
icing allowed) Storage: -20 to +60 ºC -4 to +140 °F  
35 to 85 % RH, Storage: 35 to 85 % RH  
1,000 V AC for one min. between all supply terminals  
connected together and enclosure  
MEASURE-  
MENT  
10 to 150 Hz frequency, 0.75 mm 0.030 in double  
amplitude in X, Y and Z directions for two hours each  
SENSORS  
98 m/s2 acceleration (10 G approx.) in X, Y and Z  
STATIC  
CONTROL  
DEVICES  
directions five times each  
Enclosure: Polycarbonate  
Specified cable (shielded twisted cable) (Note 5)  
Net weight: 80 g approx., Gross weight: 130 g approx.  
LASER  
MARKERS  
20 MΩ or more, with 250 V DC megger between all supply  
terminals connected together and enclosure  
Notes: 1) Where measurement conditions have not been specified precisely,  
the conditions used were an ambient temperature of +20 °C +68 °F.  
2) If our product will be incorporated in a customer product that will comply with the EMC Directive, install our product  
in a conductive box in accordance with “PLC User’s Manual [Published by Mitsubishi Electric Corporation]”.  
3) Power is supplied from a connected controller / master controller.  
4) Do not use or store in an environment that has been pressurized to  
an air pressure higher than the atmospheric pressure at 0 m.  
PLC  
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in  
X, Y and Z directions for two hours each  
HUMAN  
MACHINE  
98 m/s2 acceleration (10 G approx.) in X, Y and Z  
directions five times each  
INTERFACES  
Enclosure: Polycarbonate  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Communication Ethernet cable that satisfies 1000BASE-T standard Category 5e  
cable  
Weight  
5) Use only a special-use communication cable that is approved by the CC-Link Partner Association.  
or higher (Double-shielded / STP, straight cable) (Note 5)  
Net weight: 100 g approx.,Gross weight: 150 g approx.  
FA  
Designation  
Model No.  
Communication unit for RS-485  
COMPONENTS  
Notes: 1) Where measurement conditions have not been specified precisely,  
the conditions used were an ambient temperature of +20 °C +68 °F.  
2) Power is supplied from a connected controller / master controller.  
3) For the network No. setting on this product, convert the network  
number to hex and set the hex value.  
Item  
SC-HG1-485  
EMC Directive, RoHS Directive  
HG-SC□  
MACHINE  
VISION  
CE marking directive compliance  
SYSTEMS  
Compatible controllers  
Supply voltage  
(Note 2)  
Current consumption  
Communication method  
Synchronization method  
Communication protocol  
Baud rate  
24 V DC ±10 %, Ripple P-P 10 % or less  
(Within specified power supply voltage range)  
UV  
CURING  
4) Do not use or store in an environment that has been pressurized to  
an air pressure higher than the atmospheric pressure at 0 m.  
5) Use CC-Link Partner Association recommended cable.  
SYSTEMS  
40 mA or less  
Two-wire half duplex communication  
Start-stop synchronization  
MODBUS (RTU / ASCII) / MEWTOCOL-COM  
1.2 kbps / 2.4 kbps / 4.8 kbps / 9.6 kbps / 19.2 kbps / 38.4 kbps / 57.6 kbps / 115.2 kbps  
Complies with EIA RS-485  
Selection  
Guide  
Electrical characteristics  
Host  
Laser  
1 to 99 units when MODBUS (RTU / ASCII) is used,  
1 to 64 units when MEWTOCOL-COM is used  
Maximum of 15 controllers (1 master, 14 slaves) per  
SC-HG1-485 unit  
Displacement  
Number of  
(RS-485)  
connectable  
Magnetic  
Displacement  
units  
Sensors  
Contact  
Displacement  
Stop bit length  
Parity check  
Data bit length  
Pollution degree  
Operating altitude  
Protection  
1 bit / 2 bits  
Even / Odd / None  
8 bits (RTU) / 7 bits (ASCII)  
2
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Digital Panel  
Controller  
2,000 m 6561.68 ft or less (Note 3)  
IP40 (IEC)  
-10 to +45 °C 14 to +113 °F (No dew condensation or  
icing allowed), Storage: -20 to +60 °C -4 to +140 °F  
Other  
Products  
Ambient  
temperature  
Ambient humidity  
Voltage  
withstandability  
35 to 85 % RH, Storage: 35 to 85 % RH  
1,000 V AC for one min. between all supply terminals  
connected together and enclosure  
HG-S  
Insulation  
resistance  
20 MΩ, or more, with 250 V DC megger between all  
supply terminals connected together and enclosure  
Vibration  
10 to 150 Hz frequency, 0.75 mm 0.030 in double  
amplitude in X, Y and Z directions for two hours each  
resistance  
Shock  
resistance  
98 m/s2 acceleration (10 G approx.) in X, Y and Z  
directions five times each  
Material  
Enclosure: Polycarbonate  
Total extension  
distance  
Communication cable: 1,200 m 3,937.008 ft or less  
between SC-HG1-485 (terminal) and PLC  
Weight  
Accessory  
Net weight: 75 g approx., Gross weght: 120 g approx.  
Termination resistor switching jumper pin: 1 pc.  
Notes: 1) Where measurement conditions have not been specified precisely,  
the conditions used were an ambient temperature of +20 °C +68 °F.  
2) Power is supplied from a connected controller / master controller.  
3) Do not use or store in an environment that has been pressurized to  
an air pressure higher than the atmospheric pressure at 0 m.  
Contact-type Digital Displacement Sensor HG-S SERIES  
1104  
For communication unit for digital displacement sensors, refer to the User’s Manual.  
The User’s Manual can be downloaded from our website.  
I/O CIRCUIT DIAGRAMS  
FIBER  
SENSORS  
NPN output type  
PNP output type  
LASER  
SENSORS  
HG-SC101 / Master unit  
HG-SC101-P / Master unit  
PHOTO-  
Color code  
Color code  
ELECTRIC  
SENSORS  
+V  
+V  
(Brown) +V  
(Brown) +V  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
Load  
*1  
(Black) Output 1  
(Pink) External input 1  
(Purple) External input 2  
Load  
*1  
Load  
AREA  
(White) Output 2  
*1  
SENSORS  
SAFETY LIGHT  
(Black / Grey) Output 3  
CURTAINS  
SAFETY  
/
COMPONENTS  
(Pink / Purple) External input 3  
+
+
PRESSURE /  
FLOW  
24 V DC  
±10 %  
24 V DC  
±10 %  
(Pink) External input 1  
SENSORS  
(Black) Output 1  
INDUCTIVE  
PROXIMITY  
SENSORS  
(Purple) External input 2  
(Pink / Purple) External input 3  
(White) Output 2  
*1  
PARTICULAR  
USE  
Load  
*1  
SENSORS  
(Black / Grey) Output 3  
Load  
*1  
SENSOR  
OPTIONS  
Load  
(Blue) 0 V  
(Blue) 0 V  
(Grey) Analog current output (4 to 20 mA)  
(Grey) Analog current output (4 to 20 mA)  
SIMPLE  
0 V  
0 V  
WIRE-SAVING  
UNITS  
Load  
(250 Ω max.)  
Load  
(250 Ω max.)  
(Shield) Analog ground (Note)  
(Shield) Analog ground (Note)  
AGND  
AGND  
WIRE-SAVING  
SYSTEMS  
Internal circuit  
Users’ circuit  
Internal circuit  
Users’ circuit  
HG-SC111 / Slave unit  
HG-SC111-P / Slave unit  
MEASURE-  
MENT  
Connect to +V (Brown) of HG-SC101  
Color code  
(Black) Output 1  
Connect to +V (Brown) of HG-SC101-P  
SENSORS  
Color code  
*1  
STATIC  
Load  
CONTROL  
DEVICES  
(Pink) External input 1  
Load  
*1  
Load  
(White) Output 2  
*1  
LASER  
MARKERS  
(Purple) External input 2  
(Black / Grey) Output 3  
PLC  
(Pink / Purple) External input 3  
HUMAN  
(Pink) External input 1  
MACHINE  
INTERFACES  
(Black) Output 1  
ENERGY  
(Purple) External input 2  
MANAGEMENT  
SOLUTIONS  
(White) Output 2  
*1  
Load  
FA  
(Pink / Purple) External input 3  
*1  
*1  
COMPONENTS  
(Black / Grey) Output 3  
Load  
Load  
MACHINE  
VISION  
(Blue) 0 V  
Connect to 0 V (Blue) of HG-SC101  
SYSTEMS  
Connect to 0 V (Blue) of HG-SC101-P  
(Grey) Analog current output (4 to 20 mA)  
(Grey) Analog current output (4 to 20 mA)  
UV  
CURING  
SYSTEMS  
Load  
Load  
(Shield) Analog ground (Note)  
AGND  
(Shield) Analog ground (Note)  
AGND  
(250 Ω max.)  
(250 Ω max.)  
Internal circuit  
Users’ circuit  
Internal circuit  
Users’ circuit  
HG-SC112 / Slave unit  
HG-SC112-P / Slave unit  
Connect to +V (Brown) of HG-SC101  
Color code  
(Black) Output 1  
Connect to +V (Brown) of HG-SC101-P  
Selection  
Guide  
Color code  
*1  
Load  
Laser  
Load  
(Pink) External input 1  
Displacement  
*1  
Load  
Magnetic  
(White) Output 2  
*1  
Displacement  
(Purple) External input 2  
Contact  
Displacement  
(Black / Grey) Output 3  
Collimated  
Beam  
Sensors  
(Pink / Purple) External input 3  
Metal-sheet  
Double-feed  
Detection  
(Pink) External input 1  
Digital Panel  
Controller  
(Black) Output 1  
(White) Output 2  
Other  
Products  
(Purple) External input 2  
*1  
Load  
(Pink / Purple) External input 3  
*1  
*1  
HG-S  
(Black / Grey) Output 3  
Load  
Load  
Connect to 0 V (Blue) of HG-SC101  
Users’ circuit  
Connect to 0 V (Blue) of HG-SC101-P  
Users’ circuit  
Internal circuit  
Internal circuit  
* 1  
* 1  
Non-voltage contact or NPN open collector transistor  
Non-voltage contact or PNP open collector transistor  
or  
or  
0 to +1.2 V DC: Effective  
+4 V to +V DC: Effective  
+8 V to +V DC or open: Ineffective  
0 to +0.6 V DC or open: Ineffective  
Note: Use shielded wire for the analog output.  
Note: Use shielded wire for the analog output.  
Contact-type Digital Displacement Sensor HG-S SERIES  
1105  
Refer to the user’s manual for details. The user’s manual can be downloaded from our website.  
Refer to p.1595 for general precautions.  
FIBER  
PRECAUTIONS FOR PROPER USE  
SENSORS  
LASER  
SENSORS  
Sensor head  
Mounting  
Never use this product as a sensing device for personnel protection.  
PHOTO-  
ELECTRIC  
SENSORS  
• When using sensing devices for personnel protection, use products  
that meet the laws and standards for personnel protection that  
apply in each region or country, such as OSHA, ANSI and IEC.  
MICRO  
PHOTO-  
• When tightening the nut, take care not to damage the  
rubber bellows.  
ELECTRIC  
SENSORS  
• If the rubber bellows is deformed, a load will occur when  
the spindle operates and damage may result.  
• Do not remove the rubber bellows from the standard type  
products (HG-S1010 / HG-S1110 / HG-S1032) except for  
when replacing them. Unnecessary removal of rubber bellows  
can result in entry of dust and water, thus causing malfunction.  
AREA  
• This catalog has been prepared to aid selection of appropriate  
products. When using the product, be sure to read the user’s manual.  
SENSORS  
SAFETY LIGHT  
CURTAINS /  
SAFETY  
COMPONENTS  
PRESSURE /  
FLOW  
Part description  
Sensor head  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
1.Open a hole in the housing in  
which the sensor head will be  
<Standard type>  
(HG-S1010 / HG-S1110)  
<Standard type>  
(HG-S1032)  
PARTICULAR  
USE  
Mounting hole  
SENSORS  
mounted.  
+0.015  
6.5 to 12.5 mm  
0.256 to 0.492 in  
HG-S1032:  
ø8H7  
mm  
0
Sensor head connection  
cable connector  
Sensor head connection  
cable connector  
SENSOR  
OPTIONS  
HG-S1032:  
+0.018  
ø12H7  
mm  
6.5 to 10.5 mm  
0.256 to 0.413 in  
0
(
)
SIMPLE  
WIRE-SAVING  
UNITS  
2.Insert the sensor head into the  
hole you opened in the housing,  
and fasten provisionally with the  
provided mounting nut.  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
SENSORS  
Operation indicator  
(Orange / Green)  
Note: The orientation of the mounting nut  
depends on the thickness of the housing.  
For details, refer to DIMENSIONS  
(p.1107~).  
STATIC  
CONTROL  
DEVICES  
Mounting nut  
Mounting nut  
(accessory)  
LASER  
MARKERS  
Rubber bellows  
Probe  
Operation indicator  
(Orange / Green)  
PLC  
3.Fasten the sensor head.  
Mounting nut  
Sensor head  
When fastening the sensor head,  
tighten the mounting nut with a  
wrench while holding the sensor head  
in place with the provided sensor head  
fastening wrench as shown right.  
Tighten to a torque of 12.5 N·m or  
less. (HG-S1032: 15 N·m or less)  
fastening wrench  
(accessory)  
HUMAN  
MACHINE  
INTERFACES  
<Low measuring force type>  
(HG-S1010R / HG-S1110R)  
Rubber bellows  
Probe  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Sensor head connection  
cable connector  
FA  
COMPONENTS  
Wrench  
MACHINE  
VISION  
<Correct>  
<Incorrect>  
SYSTEMS  
4.Make sure that the rubber  
bellows has not become  
deformed as shown right.  
If the rubber bellows is  
deformed, restore the  
normal shape by rotating  
the bellows or otherwise.  
UV  
CURING  
SYSTEMS  
Operation indicator  
(Orange / Green)  
Mounting nut  
Probe  
Selection  
Guide  
Attaching the sensor head connection cable  
Laser  
Displacement  
Magnetic  
Displacement  
• When disconnecting, always make sure that the fastening ring  
has been completely loosened before pulling out the cable.  
• Risk of damage if you pull the cable with excessive  
force (15 N or more) with the fastening ring tightened.  
Contact  
Displacement  
Collimated  
Beam  
Controller  
Sensors  
Metal-sheet  
Double-feed  
Detection  
(Note)  
Digital display / operation cover  
Digital Panel  
Controller  
Mounting  
Other  
Products  
Sensor head connection cable connector  
Female connector  
1.Insert the sensor head connection  
cable into the connector for the  
sensor head connection cable on the  
sensor head.  
Male connector  
(only for slave units)  
HG-S  
(Note)  
(Note)  
2.Turn the fastening ring on the sensor  
head connector in the direction  
shown to fasten the ring.  
1. Insert  
2. Tighten  
Digital display / SUB (Green)  
Circle meter (Orange, Green)  
Guide mark (White)  
LEFT key UP key  
RIGHT key  
Removal method  
Output 1 indicator (Orange)  
Output 2 indicator (Orange)  
Output 3 indicator (Orange)  
Input indicator (White)  
1.Turn the fastening ring on the  
sensor head connector in the  
direction of the arrow to loosen  
the ring.  
2.Grasp the sensor head  
connector and pull up to remove.  
ENTER key  
DOWN key  
Status mark (White)  
Digital display / MAIN (White)  
Preset indicator (Green)  
Preset key  
EXIT key  
Copy checkmark (Orange)  
Note: Not provided on slave units or wire-saving type (HG-SC113).  
2. Pull out  
1. Loosen  
Contact-type Digital Displacement Sensor HG-S SERIES  
1106  
Refer to the user’s manual for details. The user’s manual can be downloaded from our website.  
Refer to p.1595 for general precautions.  
PRECAUTIONS FOR PROPER USE  
FIBER  
SENSORS  
LASER  
SENSORS  
Removal method  
Controller  
PHOTO-  
1.Loosen the screws on the end plates  
2.Remove the end plates.  
3.Slide and remove the controllers,  
Mounting  
Mounting  
ELECTRIC  
SENSORS  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
Slide  
1.Insert the rear of the mounting  
part into the DIN rail.  
2.While pressing down on the rear  
of the mounting part, insert the  
front of the mounting part into  
the DIN rail.  
one at a time.  
AREA  
SENSORS  
Common  
SAFETY LIGHT  
2. Press  
CURTAINS  
SAFETY  
/
1. Insert  
Wiring  
35 mm 1.378 in width DIN rail  
COMPONENTS  
PRESSURE /  
FLOW  
The product is designed to fulfill the specifications when  
SENSORS  
combined with the HG-S□ sensor head and HG-SC□  
controller. If the product is used in combination with  
other products, it not only fails to meet the specifications  
but also generates a malfunction in some cases.  
Removal method  
1. Press forward  
2. Lift  
INDUCTIVE  
PROXIMITY  
SENSORS  
1.Grasp the product and push forward.  
2.Lift the front to remove.  
PARTICULAR  
USE  
SENSORS  
• For the controller DC power supply, only use a power  
supply that is isolated by means of an isolation  
transformer or otherwise.  
• Risk of short-circuiting and damage to the controller  
or power supply if a transformer such as an auto  
transformer is used. Risk of short-circuiting and  
damage to the controller or power supply if incorrectly  
mounted or connected.  
SENSOR  
OPTIONS  
Attaching the sensor head connection cable  
Mounting  
SIMPLE  
WIRE-SAVING  
UNITS  
1.Insert the sensor head connection cable  
into the connector for the sensor head  
connection cable on the controller.  
WIRE-SAVING  
SYSTEMS  
1. Insert  
MEASURE-  
MENT  
SENSORS  
Removal method  
Lock release lever  
STATIC  
CONTROL  
DEVICES  
1.Grasp the controller, and while  
pressing on the lock release lever  
on the connector of the sensor  
head connection cable, pull toward  
you to disconnect.  
• Make sure that the power supply is off while performing  
wiring or expansion work.  
• After you have completed wiring work, check the wiring  
carefully before switching on the power.  
• Do not run the wires together with high-voltage lines or  
power lines or put them in the same raceway. This can  
cause malfunction due to induction.  
1. Pull out  
LASER  
MARKERS  
PLC  
Note: If you attempt to disconnect the cable by pulling it without pressing the  
lock release lever, cable wire breakage and connector damage may occur.  
HUMAN  
MACHINE  
INTERFACES  
• Verify that the supply voltage variation is within the rating.  
Connection  
ENERGY  
MANAGEMENT  
SOLUTIONS  
• If power is supplied from a commercial switching  
regulator, ensure that the frame ground (F.G.) terminal of  
the power supply is connected to an actual ground.  
• Do not use during the initial transient time after the power  
supply is switched on.  
• Always shut off the power before connecting a  
slave unit to or disconnecting a slave unit from the  
master unit. Risk of controller damage if you attempt  
connection with the power on.  
FA  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
• Make sure that stress by forcible bend or pulling is not  
applied directly to the sensor cable joint.  
Insert the male connector firmly into the female  
connector. Risk of controller damage if not completely  
connected.  
• To connect units, the units must be mounted on a DIN  
rail. Attach end plates MS-DIN-E (optional) so as to  
enclose the connected units at the ends.  
• Up to 15 slave units (up to 14 slave units when a  
communication unit for digital displacement sensor is  
connected) can be connected per master unit.  
• When connecting slave units to a master unit, connect  
only NPN output types, or only PNP output types.  
Dissimilar output types cannot be connected together.  
UV  
CURING  
SYSTEMS  
Others  
• This device has been developed / produced for industrial  
use only.  
• Do not use this product outside the range of the  
specifications. Risk of an accident and product damage.  
There is also a risk of a noticeable reduction of service  
life.  
• This controller uses an EEPROM. The EEPROM has a  
service life of one million setting operations.  
• This product is suitable for indoor use only.  
• Avoid dust, dirt, and steam.  
Selection  
Guide  
Laser  
Displacement  
Magnetic  
Displacement  
Contact  
Displacement  
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Master unit  
Connection method  
Digital Panel  
Controller  
• Take care that the product does not come in direct  
contact with organic solvents such as thinner.  
1.Mount one master unit on the DIN  
rail.  
Other  
Products  
• Take care that the product does not come in direct  
contact with strong acid or alkaline.  
• Take care that the product does not come in direct  
contact with oil or grease.  
2.Remove the connector cover.  
3.Mount each slave unit one at a  
time on the DIN rail. Remove all  
connector covers except for the  
cover on the end slave unit.  
Slave unit  
HG-S  
Connector cover  
Do not use in an environment containing inflammable or  
Slide  
explosive gases.  
• Performance may not be satisfactory in a strong  
4.Slide each slave unit to connect  
the female and male connectors.  
electromagnetic field.  
• This product is a precision device. Do not drop or  
otherwise subject to shock. Risk of product damage.  
• Never attempt to disassemble, repair, or modify the  
product.  
5.Attach end plates MS-DIN-E  
(optional) with the flat side facing  
in so as to enclose the connected  
units at the ends.  
6.Tighten the screws to fasten the  
end plates.  
End plate  
MS-DIN-E (optional)  
End plate  
MS-DIN-E (optional)  
Contact-type Digital Displacement Sensor HG-S SERIES  
1107  
FIBER  
DIMENSIONS (Unit: mm in)  
The CAD data can be downloaded from our website.  
SENSORS  
LASER  
Sensor head  
SENSORS  
HG-S1010(R) HG-S1110(R)  
PHOTO-  
ELECTRIC  
SENSORS  
Installation of sensor head connection cable  
Standard type  
HG-S1010 / HG-S1110  
Low measuring force type  
HG-S1010R / HG-S1110R  
The diagrams show the sensor head connection cable  
connected to the low measurement force type.  
Sensor head connection cable (Straight type)  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
18  
18  
Sensor head connection  
cable (L-shaped type)  
0.709  
AREA  
0.709  
SENSORS  
11  
0.433  
11  
0.433  
11  
0.433  
11  
0.433  
74.3  
2.925  
15 0.591  
or more  
SAFETY LIGHT  
CURTAINS /  
SAFETY  
15 0.591  
or more  
23  
0.906  
2.5  
0.098  
76.3  
3.004  
COMPONENTS  
ø9  
3.8  
0.150  
ø0.354  
PRESSURE /  
FLOW  
SENSORS  
27.5  
1.083  
23.5  
0.925  
ø9.5  
ø0.374  
3.8  
0.150  
INDUCTIVE  
PROXIMITY  
SENSORS  
84.5  
84.5  
3.327  
3.327  
Operation  
indicator  
(Orange / Green)  
Operation  
indicator  
(Orange / Green)  
PARTICULAR  
USE  
135.5  
5.335  
135.5  
5.335  
2.5  
2.5  
0.098  
SENSORS  
0
0
0.098  
-0.022  
0
-0.022  
0
ø8  
ø8  
2 face width  
10 0.394  
2 face width  
10 0.394  
SENSOR  
OPTIONS  
ø0.315  
ø0.315  
-0.001  
-0.001  
10  
0.394  
10  
0.394  
Rubber  
bellows  
M8 × 0.5  
M8 × 0.5  
0.020  
0.020  
SIMPLE  
WIRE-SAVING  
UNITS  
46  
1.811  
46  
1.811  
6
6
0.236  
0.236  
WIRE-SAVING  
SYSTEMS  
SR1.59 SR0.063  
7 0.276  
7 0.276  
SR1.59 SR0.063  
MEASURE-  
MENT  
SENSORS  
Installation of mounting nut attachment  
STATIC  
CONTROL  
DEVICES  
Standard type  
HG-S1010 / HG-S1110  
Low measuring force type  
HG-S1010R / HG-S1110R  
6.5 to 10 0.256 to 0.394  
(plate thickness)  
10 to 12.5 0.394 to 0.492  
(plate thickness)  
6.5 to 10 0.256 to 0.394  
(plate thickness)  
10 to 12.5 0.394 to 0.492  
(plate thickness)  
LASER  
MARKERS  
7
7
PLC  
0.276  
0.276  
HUMAN  
MACHINE  
A
A
Mounting nut  
Mounting nut  
INTERFACES  
Mounting nut  
Mounting nut  
Threaded  
part  
Threaded  
part  
Threaded  
part  
Threaded  
part  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Mounting nut  
10 0.394  
Mounting nut  
10 0.394  
Detail of part A  
Detail of part A  
FA  
COMPONENTS  
Sensor head  
HG-S1032  
MACHINE  
VISION  
SYSTEMS  
Installation of mounting nut  
attachment  
Installation of sensor head connection cable  
UV  
CURING  
Sensor head connection cable (Straight type)  
Sensor head connection  
cable (L-shaped type)  
SYSTEMS  
76.8  
3.024  
15 0.591  
or more  
5
15 0.591  
or more  
7
23  
17.5  
0.689  
27  
0.906  
0.276  
76.3  
1.063  
0.197  
ø9  
ø0.354  
5
3.004  
ø3.8  
Selection  
Guide  
17.5  
0.689  
0.197  
ø0.150  
A
Mounting nut  
Laser  
27.5  
1.083  
23.5  
0.925  
ø9.5  
ø0.374  
Displacement  
3.8  
0.150  
Detail of part A  
Magnetic  
Displacement  
6.5 to 8.5 0.256 to 0.335  
(plate thickness)  
Contact  
Displacement  
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Mounting nut  
133.5  
5.256  
Digital Panel  
Controller  
14  
0.551  
Other  
Products  
Mounting nut  
Threaded  
part  
Operation  
indicator  
(Orange / Green)  
HG-S  
3
0
0.118  
-0.027  
0
ø12  
8.5 to 10.5 0.335 to 0.413  
(plate thickness)  
ø0.472  
-0.001  
8.5  
0.335  
M12 × 0.75  
0.030  
6.5  
0.256  
78.5  
3.091  
14 0.551  
(2 face width)  
Mounting nut  
Threaded  
part  
10.25  
0.404  
SR1.59 SR0.063  
Contact-type Digital Displacement Sensor HG-S SERIES  
1108  
DIMENSIONS (Unit: mm in)  
FIBER  
The CAD data can be downloaded from our website.  
Controller (Master unit)  
SENSORS  
LASER  
HG-SC101(-P)  
SENSORS  
PHOTO-  
ELECTRIC  
SENSORS  
Output 1 indicator (Orange)  
LEFT key  
UP key  
RIGHT key  
Output 2 indicator (Orange)  
Output 3 indicator (Orange)  
Input indicator (White)  
Preset indicator (Green)  
Preset key  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
DOWN key  
ENTER key  
AREA  
SENSORS  
EXIT key  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
ø5.5 ø0.217 cable, 2 m 6.562 ft  
(9-core composite cable)  
INDUCTIVE  
PROXIMITY  
SENSORS  
3
0.118  
20 0.787  
21.1  
0.831  
3.2 0.126  
80 3.150  
or more  
15 0.591  
or more  
PARTICULAR  
USE  
SENSORS  
43.1  
1.697  
19.9  
SENSOR  
OPTIONS  
0.783  
20  
0.787  
13.8  
0.543  
5.9 0.232  
SIMPLE  
16  
0.630  
WIRE-SAVING  
UNITS  
3
6.5 0.256  
0.118  
58.5  
14.3 0.563  
21.5  
0.846  
36.5  
1.437  
64.8  
2.551  
WIRE-SAVING  
SYSTEMS  
2.303  
Suitable for 35 mm 1.378 in width DIN rail  
MEASURE-  
MENT  
SENSORS  
Controller (Slave unit)  
HG-SC111(-P) HG-SC112(-P)  
STATIC  
CONTROL  
DEVICES  
Output 1 indicator (Orange)  
Output 2 indicator (Orange)  
Output 3 indicator (Orange)  
LEFT key  
UP key  
LASER  
RIGHT key  
MARKERS  
Input indicator (White)  
Preset indicator (Green)  
Preset key  
PLC  
DOWN key  
ENTER key  
HUMAN  
EXIT key  
MACHINE  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
HG-SC111(-P): ø5.5 ø0.217 cable, 2 m 6.562 ft  
(7-core composite cable)  
HG-SC112(-P): ø5.5 ø0.217 cable, 2 m 6.562 ft  
(6-core cable)  
FA  
21.1  
0.831  
3
0.118  
COMPONENTS  
5.6  
0.220  
20 0.787  
or more  
3.2 0.126  
80 3.150  
MACHINE  
VISION  
15 0.591  
or more  
SYSTEMS  
43.1  
UV  
19.9  
1.697  
CURING  
SYSTEMS  
20  
0.787  
0.783  
13.8  
0.543  
5.9 0.232  
16  
0.630  
3
6.5 0.256  
0.118  
14.3 0.563  
58.5  
64.8  
2.551  
21.5  
0.846  
36.5  
1.437  
2.303  
Selection  
Guide  
Suitable for 35 mm 1.378 in width DIN rail  
Laser  
Displacement  
Controller (Slave unit)  
Magnetic  
HG-SC113  
Displacement  
Contact  
Displacement  
Output 1 indicator (Orange)  
Output 2 indicator (Orange)  
Output 3 indicator (Orange)  
Collimated  
LEFT key  
UP key  
Beam  
Sensors  
RIGHT key  
Metal-sheet  
Double-feed  
Detection  
Input indicator (White)  
Preset indicator (Green)  
Preset key  
Digital Panel  
Controller  
DOWN key  
ENTER key  
Other  
Products  
EXIT key  
HG-S  
21.1  
0.831  
5.6  
0.220  
3.2 0.126  
15 0.591  
80 3.150  
2.6 0.102  
or more  
43.1  
1.697  
19.9  
0.783  
13.8  
0.543  
5.9 0.232  
16  
0.630  
3
6.5 0.256  
0.118  
14.3 0.563  
Suitable for 35 mm 1.378 in width DIN rail  
64.8  
2.551  
21.5  
0.846  
36.5  
1.437  
Contact-type Digital Displacement Sensor HG-S SERIES  
1109  
FIBER  
DIMENSIONS (Unit: mm in)  
The CAD data can be downloaded from our website.  
Communication unit for RS-485  
SENSORS  
LASER  
Communication unit for CC-Link IE Field  
SC-HG1-CEF  
SC-HG1-485  
SENSORS  
PHOTO-  
ELECTRIC  
SENSORS  
18  
Power indicator (Green)  
18  
0.709  
0.709  
D LINK indicator (Green)  
Power indicator (Green)  
RUN indicator (Green)  
14  
MICRO  
PHOTO-  
RD indicator (Green)  
Communication indicator (Green)  
Upper communication error indicator (Red)  
Lower communication error indicator (Red)  
14  
0.551  
0.551  
STS1 indicator (Green)  
STS2 indicator (Red)  
ELECTRIC  
SENSORS  
01.3094  
01.3094  
6
AREA  
16.6  
0.654  
16.6  
0.654  
0.236  
6
Upper communication  
connector  
SENSORS  
0.236  
SAFETY LIGHT  
CURTAINS /  
SAFETY  
21  
0.827  
COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
Communication setting switches  
30.6 1.205 21.1 0.831  
Port1 LINK indicator (Green)  
Port 1 ERR. indicator (Yellow)  
Port 2 LINK indicator (Green)  
Port 2 ERR. indicator (Yellow)  
ERROR indicator (Red)  
SD indicator (Green)  
INDUCTIVE  
PROXIMITY  
SENSORS  
10.6  
Upper communication  
connector  
58.5 2.303  
Termination resistor  
switching jumper  
pin (Note)  
0.417  
Station No. / Network No.  
setting switch  
21.1  
0.831  
PARTICULAR  
USE  
Communication setting  
switch cover  
SENSORS  
21.2  
0.835  
43.1  
1.697  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
38 1.496  
MEASURE-  
MENT  
9.55  
21.5 0.846  
80 3.150  
0.376  
38 1.496  
9.55  
0.376  
SENSORS  
21.5  
Suitable for 35 mm 1.378 in width DIN rail  
80  
3.150  
0.846  
STATIC  
CONTROL  
DEVICES  
Suitable for  
35 mm 1.378 in width DIN rail  
Setting switch cover  
Note: The termination resistor switching jumper pin is not attached to the  
product at the factory.  
LASER  
MARKERS  
Attach the termination resistor switching jumper pin to the unit at the  
terminating end.  
Make sure that the termination resistor switching jumper pin have been  
removed from all units except the one at the terminating end.  
PLC  
HUMAN  
MACHINE  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Communication unit for CC-Link  
End plate  
SC-HG1-C  
MS-DIN-E  
FA  
COMPONENTS  
L_RUN (communication operation)  
indicator (Green)  
MACHINE  
VISION  
SYSTEMS  
M3 (length 18 mm 0.709 in) pan head screw  
RD (data transmission)  
indicator (Green)  
2.75 0.108  
14  
UV  
CURING  
0.551  
3 0.118  
15  
60 2.362  
3 0.118  
M3 square nut  
SYSTEMS  
Power indicator (Green)  
ERR. indicator (Red)  
5.6  
01.3094  
0.591  
0.220  
6
0.236  
24.7  
0.972  
02.8127  
Selection  
Guide  
4
32  
1.6  
0.157  
Suitable for 35 mm 1.378 in width DIN rail  
1.260  
0.063  
Laser  
L_ERR (communication error) indicator (Red)  
SD (data reception/transmission) indicator (Green)  
Communication setting switches  
Displacement  
Upper  
communication  
connector  
35.7 21.1  
Magnetic  
1.406 0.831  
55.9 2.201  
Displacement  
Material: Polycarbonate  
Contact  
Displacement  
Collimated  
Communication  
setting switch cover  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Digital Panel  
Controller  
Other  
Products  
HG-S  
38  
1.496  
9.55  
21.5  
0.376  
0.846  
80 3.150  
Suitable for 35 mm 1.378 in width DIN rail  
1110  
MEMO  

相关型号:

HG-SC111-P

Contact-type Digital Displacement Sensor
PANASONIC

HG-SC112

Contact-type Digital Displacement Sensor
PANASONIC

HG-SC112-P

Contact-type Digital Displacement Sensor
PANASONIC

HG-SC113

Contact-type Digital Displacement Sensor
PANASONIC

HG02403000J0G

Barrier Strip Terminal Block
AMPHENOL

HG02406000J0G

Barrier Strip Terminal Block
AMPHENOL

HG03504000J0G

Barrier Strip Terminal Block
AMPHENOL

HG04308000J0G

Barrier Strip Terminal Block,
AMPHENOL

HG05208000J0G

Barrier Strip Terminal Block,
AMPHENOL

HG0630C000J0G

Barrier Strip Terminal Block
AMPHENOL

HG07403000J0G

Barrier Strip Terminal Block
AMPHENOL

HG07404000J0G

Barrier Strip Terminal Block
AMPHENOL