HG2-DC48V-F [PANASONIC]
TYPICAL APPLICATIONS; 典型应用![HG2-DC48V-F](http://pdffile.icpdf.com/pdf1/p00185/img/icpdf/HG2-DC_1048105_icpdf.jpg)
型号: | HG2-DC48V-F |
厂家: | ![]() |
描述: | TYPICAL APPLICATIONS |
文件: | 总9页 (文件大小:2526K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Discontinued as of August 31, 2012
20 AMP POWER RELAY
HG RELAYS
TYPICAL APPLICATIONS
HP relays enjoy wide use in various
applications, particularly in automation
controls and remote controls.
9. Amusement equipment
Control of equipment in amusement
parks, etc., control of bowling alley
equipment, control of fountains in public
parks
Applications include:
1. Industrial machinery
For controlling positioning, pressure, and
temperature in molding equipment,
boilers, pumps, charging pressure
equipment, measuring and evaluation
equipment, textile machines, etc.
2. Machine tools
Control of positioning and directional
change in turning machines, lathes,
borers, etc.
3. Food processing packing machines
Automatic control of packing equipment
for milk and seafood, bottling, canning,
and packaging
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances. (The suffix “F”
should be added to the part number.)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
Product to be discontinued.
FEATURES
1. High-capacity and long life
The electrical life of this high capacity is
20A 100,000 operations (250 V AC). It
can be used for 1.5kW (3-phase 200 V)
motor control.
4. Office equipment
Control of copiers, time recorders, etc.
5. Coin operate machines
Control of food, cigarette, and other
vending machines
2. High breakdown voltage
Both between contacts, and between
contacts and coil, high breakdown
voltage is 2,000 V for 1 minute.
3. Easy mounting and wiring
The terminal arrangement is apparent at
a glance and wiring is easy. Moreover,
#250 series tab terminals can be used.
4. Socket and terminal sockets
available
Lineup includes DIN terminal sockets that
enable the use of DIN rails. The pole
numbers of the terminal sockets are
interchangeable and different terminal
sockets can be used in combination.
5. UL/CSA approved
6. Measuring devices and equipment
For repeating installation of control
signals and in power amplifiers
7. Generators, transformers and
power receiving equipment
Functional parts in protective equipment,
functional assistance in automatic
adjustment equipment, telemeters and
other remote monitoring equipment
8. Control of conveyance equipment
Control panels for elevators, escalators,
and other conveyance equipment, control
of all kinds industrial transport equipment
such as conveyors.
ORDERING INFORMATION
HG
F
Contact arrangement
2: 2 Form C
3: 3 Form C
4: 4 Form C
Coil voltage
AC 24, 48, 100, (115), 200, (220), (240) V
DC 12, 24, 48, 100, (110), 200 V
Contact material
F: AgSnO2 type
The voltage values in parentheses are for order-made products for export.
Note: UL/CSA approved type is standard.
ds_61C08_en_hg: 011111D
1
HG
Discontinued as of August 31, 2012
TYPES
2 Form C
3 Form C
4 Form C
Coil voltage
Part No.
Part No.
Part No.
24V AC
48V AC
HG2-AC24V-F
HG2-AC48V-F
HG2-AC100V-F
HG2-AC115V-F
HG2-AC200V-F
HG2-AC220V-F
HG2-AC240V-F
HG2-DC12V-F
HG2-DC24V-F
HG2-DC48V-F
HG2-DC100V-F
HG2-DC110V-F
HG2-DC200V-F
HG3-AC24V-F
HG3-AC48V-F
HG3-AC100V-F
HG3-AC115V-F
HG3-AC200V-F
HG3-AC220V-F
HG3-AC240V-F
HG3-DC12V-F
HG3-DC24V-F
HG3-DC48V-F
HG3-DC100V-F
HG3-DC110V-F
HG3-DC200V-F
HG4-AC24V-F
HG4-AC48V-F
HG4-AC100V-F
HG4-AC115V-F
HG4-AC200V-F
HG4-AC220V-F
HG4-AC240V-F
HG4-DC12V-F
HG4-DC24V-F
HG4-DC48V-F
HG4-DC100V-F
HG4-DC110V-F
HG4-DC200V-F
100V AC
115V AC
200V AC
220V AC
240V AC
12V DC
24V DC
48V DC
100V DC
110V DC
200V DC
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.
Note: Terminal sockets and sockets are not included. Please order these separately.
RATING
1. Coil data
1) AC coils
Nominal operating
current
[20%] (at 20C 68F)
Nominal operating
power
Max. allowable
voltage
(at 40C 104F)
Coil inductance
Contact
arrangement
Nominal coil
voltage
Pick-up voltage Drop-out voltage
(at 20C 68F) (at 20C 68F)
50Hz
167mA
86mA
60Hz
150mA
75mA
50Hz
60Hz
50Hz
60Hz
24V AC
48V AC
0.441H
1.717H
7.457H
9.868H
30.39H
35.99H
42.06H
0.299H
1.195H
5.174H
6.844H
20.71H
25.00H
29.97H
0.204H
0.817H
3.540H
4.685H
14.16H
17.48H
20.48H
0.416H
1.660H
7.216H
9.531H
29.00H
34.82H
41.68H
0.290H
1.163H
5.039H
6.648H
20.14H
24.27H
29.06H
0.199H
0.795H
3.444H
4.557H
13.79H
16.89H
19.87H
100V AC
115V AC
200V AC
220V AC
240V AC
24V AC
42mA
36mA
80%V or less of 30%V or more of
nominal voltage nominal voltage
110%V of
nominal voltage
2 Form C
3 Form C
4 Form C
36mA
31.3mA
18mA
4.2VA
3.6VA
(Initial)
(Initial)
21mA
19mA
16.4mA
15mA
18mA
250mA
125mA
61mA
216mA
108mA
52mA
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
24V AC
80%V or less of 30%V or more of
nominal voltage nominal voltage
110%V of
nominal voltage
52.4mA
30mA
45.2mA
26mA
6.0VA
8.8VA
5.2VA
7.6VA
(Initial)
(Initial)
27.3mA
25mA
23.6mA
21.6mA
316mA
158mA
76mA
367mA
184mA
88mA
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
80%V or less of 30%V or more of
nominal voltage nominal voltage
110%V of
nominal voltage
76.8mA
44mA
66.1mA
38mA
(Initial)
(Initial)
39mA
34mA
36.6mA
31.6mA
ds_61C08_en_hg: 011111D
2
HG
Discontinued as of August 31, 2012
2) DC coils
Nominal operating
current
[10%] (at 20C 68F)
Max. allowable
voltage
(at 40C 104F)
Contact
arrangement
Nominal coil
voltage
Pick-up voltage Drop-out voltage
(at 20C 68F) (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
12V DC
24V DC
48V DC
100V DC
110V DC
200V DC
12V DC
24V DC
48V DC
100V DC
110V DC
200V DC
12V DC
24V DC
48V DC
100V DC
110V DC
200V DC
119.6mA
57.6mA
30.3mA
14.4mA
14.4mA
7.2mA
100
416
1.4W
1.4W
1.5W
1.4W
1.6W
1.4W
1.6W
1.6W
1.6W
1.7W
1.8W
1.7W
2.0W
1.9W
2.2W
2.0W
2.2W
2.6W
80%V or less of 10%V or more of
1,585
6,950
7,650
27,800
89.5
110%V of
nominal voltage
2 Form C
nominal voltage
(Initial)
nominal voltage
(Initial)
134mA
66mA
364
80%V or less of 10%V or more of
33.1mA
16.5mA
16.5mA
8.4mA
1,450
6,060
6,670
23,800
71.4
110%V of
nominal voltage
3 Form C
nominal voltage
(Initial)
nominal voltage
(Initial)
168mA
81.2mA
45.7mA
20.3mA
20.3mA
12.9mA
296
80%V or less of 10%V or more of
1,050
4,930
5,420
15,500
110%V of
nominal voltage
4 Form C
nominal voltage
(Initial)
nominal voltage
(Initial)
Notes: 1. The rated current area is15% (60Hz) [AC coils],. 10% (20C) [DC coils]
2. The coil resistance for DC operation is the value measured when the coil temperature is 20C 68F. Compensate 0.4% for every 1C change in temperature.
3. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will
flow leading possibly to coil burnout.
4. As a general rule, only a pure DC voltage should be used for the coil drive.
However, a DC power supply that contains ripples has characteristics that differ from pure DC.
Therefore, please verify characteristics (operate voltage, release voltage, humming) using the actual circuit that will be used.
2. Specifications
Characteristics
Item
Initial contact resistance, max
Contact material
Specifications
Max. 15 m (By voltage drop 6 V DC 1A)
AgSnO2 type
Contact
Nominal switching capacity
Min. switching capacity (Reference value)*1
20A 250V AC (resistive load)
100mA 5V DC
Rating
Min. 100M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Insulation resistance (Initial)
Between open contacts
2,000 Vrms for 1min (Detection current: 10mA.)
2,000 Vrms for 1min (Detection current: 10mA.)
2,000 Vrms for 1min (Detection current: 10mA.)
Breakdown voltage
Between contact sets
(Initial)
Electrical
Between contact and coil
characteristics
Max. 30ms (2 Form C), Max.40ms (3 Form C, 4 Form C)
(Nominal voltage applied to the coil, excluding contact bounce time.)
Operate time*2
Max. 30ms (2 Form C), Max.40ms (3 Form C, 4 Form C)
(Nominal voltage applied to the coil, excluding contact bounce time.) (without diode)
Release time*2
Min. 98 m/s2 (Except for contact operating direction)
(Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Functional
Shock resistance
Mechanical
characteristics
Destructive
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10s.)
10 to 55 Hz at double amplitude of 2 mm
Min. 107 (at 180 cpm)
Min. 106 (at 180 cpm)
20A 250V AC resistive load (cos=1), Min. 105
Functional
Vibration resistance
Destructive
AC coil
Mechanical
Expected life
Conditions
DC coil
Electrical
Ambient temperature: –50C to +40C –58F to +104F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions for operation, transport and storage*3
Max. Operating speed
20 cpm (at max. rating)
Unit weight
Notes:
2 Form C: approx. 130g 4.59oz, 3 Form C: approx. 185g 6.53oz, 4 Form C: approx. 240g 8.47oz
*1This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load.
*2 For the AC coil types, the operate/release time will differ depending on the phase.
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
ds_61C08_en_hg: 011111D
3
HG
Discontinued as of August 31, 2012
REFERENCE DATA
1. Switching capacity range
AC resistive
load
20
10
AC inductive
load (cosϕ=0.4)
DC resistive
load
DC inductive
load (L/R=7ms)
1
0.1
10
100
500 1,000
Contact voltage, V
DIMENSIONS(mm inch)
Download CADData from our Web site.
2 Form C
CAD Data
External dimensions
Schematic (Bottom view)
2.5 dia. 9 deep hole for
7
2
8.4
7
3 dia. tapping screw
.331
.276
8
6
5
1
3
4
.098 dia. .354 deep hole for
.118 dia. tapping screw
16
20.5
.807
.630
2.5 dia. 8 deep hole for
3 dia. tapping screw
.098 dia. .315 deep hole for
.118 dia. tapping screw
15
.591
34
36
1.339
1.417
56
2.205
4
8.5
.157
.335
Compatible with tab terminal
#250 series receptacle.
7
.276
10.5
.413
7.5
.295
7.26
.286
17
.669
General tolerance: 0.5 .020
3 Form C
CAD Data
External dimensions
Schematic (Bottom view)
2.5 dia. 9 deep hole for
3 dia. tapping screw
10
2
8.4
8.4
7
.331 .331
.276
11
9
1
4
5
.098 dia. .354 deep hole for
.118 dia. tapping screw
3
6
7
16
8
20.5
.807
.630
2.5 dia. 8 deep hole for
3 dia. tapping screw
.098 dia. .315 deep hole for
.118 dia. tapping screw
17
.669
50
36
1.969
1.417
56
2.205
4
8.5
.157
.335
Compatible with tab terminal
#250 series receptacle.
7
.276
10.5
.413
7.5
.295
7.26
.286
17
17
.669 .669
General tolerance: 0.5 .020
ds_61C08_en_hg: 011111D
4
HG
Discontinued as of August 31, 2012
4 Form C
CAD Data
External dimensions
Schematic (Bottom view)
2.5 dia. 9 deep hole for
3 dia. tapping screw
10
1
8.4
8.4
7
.331
.331
.276
9
8
7
2
3
4
.098 dia. .354 deep hole for
.118 dia. tapping screw
15 11
14 12
6 5
16
20.5
.807
.630
2.5 dia. 8 deep hole for
3 dia. tapping screw
.098 dia. .315 deep hole for
.118 dia. tapping screw
34
1.339
68
36
2.677
1.417
56
2.205
4
8.5
.157
.335
Compatible with tab terminal
#250 series receptacle.
7
.276
10.5
.413
7.5
.295
7.26
.286
17
17
17
.669 .669 .669
General tolerance: 0.5 .020
For Cautions for Use, see Relay Technical Information.
ds_61C08_en_hg: 011111D
5
Discontinued as of August 31, 2012
ACCESSORIES
(Sockets and
Terminal sockets)
HG RELAY
ACCESSORIES
Socket
Products to be discontinued.
Terminal socket for DIN rail assembly
TYPES
1. For DIN rail terminal sockets, sockets and general terminal sockets hold-down clip included.
2. The terminal socket installation rail can be used also for the square plug-in terminal socket of the timer and the terminal
socket of the HP relay.
Packing quantity
Type
No. of poles
Item
HG2-socket
Part No.
Carton
10 pcs.
5 pcs.
5 pcs.
10 pcs.
5 pcs.
Case
2-pole
3-pole
4-pole
2-pole
3-pole
HG2-SS
HG3-SS
HG4-SS
HG2-SFD
HG3-SFD
50 pcs.
25 pcs.
25 pcs.
50 pcs.
25 pcs.
Socket
HG3-socket
HG4-socket
HG2-DIN terminal socket
HG3-DIN terminal socket
DIN rail terminal socket
Note: For a 4-pole relay with DIN rail terminal socket, use two 2-pole types side by side.
Socket and terminal socket conform to UL, CSA as standard.
ds_61C08_en_hg: 011111D
6
HG
Discontinued as of August 31, 2012
DIMENSIONS (Unit: mm inch)
1. Socket (with hold-down clip)
HG2-Socket (HG2-SS)
External dimensions
Mounting hole diagram
With a relay mounted
17±0.1
31.5±0.5
22
.669±.004
1.240±.020
.866
6±0.3
4.2±0.3
.236±.012
6.2±0.3
.165±.012
.244±.012
48±0.5
1.890±.020
59±1
2.323±.039
40.5
36.5
37.5±0.5
1.594
1.437
1.476±.020
48
1.890
6±0.3
.236±.012
2-4.2 dia. hole
(or 2-M4 screw hole)
14.5
.571
17±0.1
2-.165 dia. hole
(or 2-M.157 screw hole)
.669±.004
22
Approx.
23.5
.925
.866
Note: Hold-down clip is
packaged with the
socket.
Compatible with tab terminal
#250 series receptacle.
34
1.339
30.5
1.201
General tolerance: 0.6 .024
HG3-Socket (HG3-SS)
External dimensions
Mounting hole diagram
With a relay mounted
17
48±0.5
28
.669
1.890±.020
1.102
4.2±0.3
6.2±0.3
6±0.3
.165±.012
.244±.012
.236±.012
48±0.5
1.890±.020
40.5
59
2.323
48
36.5
1.594
1.437
37.5±0.5
1.476±.020
1.890
6±0.3
28
.236±.012
14.5
1.102
2-4.2 dia. hole
.571
34
(or 2-M4 screw hole)
Approx.
23.5
.925
1.339
2-.165 dia. hole
(or 2-M.157 screw hole)
Compatible with tab terminal
#250 series receptacle.
51±1
Note: Hold-down clip is
packaged with the
socket.
2.008±.039
47
1.850
General tolerance: 0.6 .024
HG4-Socket (HG4-SS)
External dimensions
Mounting hole diagram
With a relay mounted
17
65.5±0.5
45
.669
2.579±.020
6
1.772
4.2±0.3
.165±.012
6.2±0.3
.236
.244±.012
48±0.5
59
2.323
48
1.890
40.5
36.5
1.890±.020
1.594
1.437
37.5±0.5
1.476±.020
6
17±0.1
.236
14.5
.669±.004
.571
45
2-4.2 dia. hole
Approx.
23.5
.925
1.772
51
(or 2-M4 screw hole)
2-.165 dia. hole
(or 2-M.157 screw hole)
Note: Hold-down clip is
packaged with the
socket.
2.008
Compatible with tab terminal
#250 series receptacle.
68±1
2.677±.039
64.5±1
2.539±.039
General tolerance: 0.6 .024
ds_61C08_en_hg: 011111D
7
HG
Discontinued as of August 31, 2012
2. Terminal socket for DIN rail assembly (with hold-down clip and installation screw)
HG2-Terminal socket for DIN rail assembly (HG2-SFD)
With a relay mounted
Note: Hold-down clip is packaged with the terminal socket.
External dimensions
Schematic
Mounting hole diagram
* Installation screw block
2
10±0.2
7
26±0.2
26±0.2
.394±.008
1.024±.008
1.024±.008
(installation screw, hexagonal nut,
spring washer)
26±0.6
21±0.6
1
8
.827±.024
1.024±.024
17±0.2
.669±.008
10±0.6
.394±.024
M4 screw
M.157
Hold-down clip
4.5±0.3
.177±.012
6
±0.3
.236±.012
80
3.150
69±0.2
3
6
2.717±.008
0.56±0.15
.022±.006
69±1
2.717±.039
10.44±0.2
.411±.008
7.56±0.2
.298±.008
4
5
58±1
80±1
3.150±.039
2.283±.039
2-M4 screw hole
2
.079
34
34
1.339
(or 4.2±0.1 dia. hole)
1.339
7.26±0.2
2-M.157 screw hole
(or .165±.004 dia. hole)
.286±.008
Panel hole dimensions
for side-by-side installation
9±0.3
HG2 relay
34.5±0.6
1.358±.024
36±0.6
.354±.012
34±0.6
Tolerance: 0.1 .004
1.339±.024
1.417±.024
*For direct mounting, use the included installation screw
block.
HG3-Terminal socket for DIN rail assembly (HG3-SFD)
With a relay mounted
Note: Hold-down clip is packaged with the terminal socket.
External dimensions
Schematic
Mounting hole diagram
* Installation screw block
2
12
10
10±0.2
.394±.008
43±0.2
43±0.2
(installation screw, hexagonal nut,
spring washer)
43±0.6
1.693±.024
17±0.2 17±0.2
.669±.008 .669±.008
21±0.6
1
3
11
1.693±.008
1.693±.008
.827±.024
10±0.6
M4 screw
M.157
Hold-down clip
4.5±0.3
.177±.012
6±0.3
.394±.024
.236±.012
80
3.150
4
6
9
69±1
2.717±.039
69±0.5
2.717±.020
0.56±0.15
.022±.006
10.44±0.2
.411±.008
7.56±0.2
.298±.008
80±1
58±1
5
7
8
3.150±.039
2.283±.039
2
.079
51
51
2.008
2.008
2-M4 screw hole
7.26±0.2
.286±.008
(or 4.2±0.1 dia. hole)
Panel hole dimensions
for side-by-side installation
2-M.157 screw hole
(or .165±.004 dia. hole)
9±0.3
HG2 relay
34.5±0.6
.354±.012
1.358±.024
Tolerance: 0.1 .004
*For direct mounting, use the included installation screw
block.
51±0.6
36±0.6
2.008±.024
1.417±.024
ds_61C08_en_hg: 011111D
8
HG
Discontinued as of August 31, 2012
With 4-pole HG relays, use two HG2-Terminal sockets
for DIN rail assembly side by side.
With a relay mounted
Schematic for terminal socket and relay
1
2
7
2
7
10
9
2
1
15
1
3
8
8
11
Note: The plain numbers
denote the terminal
socket terminal
HG4
number. The white
numbers in black
circles denote the
relay terminal
3
6
6
3
4
12
14
8
6
7
5
4
5
4
5
number.
Note: Hold-down clip is packaged with the terminal socket.
(TOP VIEW)
OTHER WAYS TO MOUNT RELAYS
With direct mounting by cover tapping
(Tab terminal connection)
Compatible with #250 series
Mounting hole diagram
2-3.5 dia. hole
2-.138 dia.
HG2
A
(Dimension A)
HG2: 15mm .591inch
HG3: 17mm .669inch
HG4: 34mm 1.339inch
3 dia. tapping screw
.118 dia.
TERMINAL SOCKET (SOCKET) COMBINATION
Because the pole numbers of the terminal sockets (sockets) are interchangeable,
different terminal sockets (sockets) can be used in combination.
HG4
HG2
HG2
HG2
HG4 main unit Æ HG2 terminal socket + HG2 terminal socket
HG2 main unit + HG2 main unit + HG2 main unit Æ HG3 terminal socket + HG3 terminal socket
HG3
HG3
HG3 main unit + HG3 main unit Æ HG2 terminal socket + HG2 terminal socket + HG2 terminal socket
NOTES
1. Hold-down clip
the direction of contact switching. (In
4. Do not insert or remove relays into
or out of live circuits.
5. To prevent damage or distortion,
when tightening fixing screws, the
optimum torque range should be 1.176
to 1.37 N·m (12 to 14 kgf·cm).
Please use the hold-down clip whenever
HG relays will be used in applications
where strong vibrating or shock force
occurs.
direction of contact switching operation,
resistance to external shock is more than
98 m/s2). Moreover, if the mounted relay
is likely to be susceptible to strong
vibrations or shocks, be sure to fit the
hold-down clip.
2. Mounting direction
There is no restriction on the mounting
direction. However, if the mounted relay
will be susceptible to strong vibrations or
shocks, to avoid influence on switching
operations, mount so that the direction of
vibration and shock are not in line with
3. Environment
Avoid use in adverse conditions, such as
where there is exposure to harmful gas,
or where ambient temperatures are high
(more than 40C).
For Cautions for Use, see Relay Technical Information.
ds_61C08_en_hg: 011111D
9
相关型号:
![](http://pdffile.icpdf.com/pdf2/p00308/img/page/HG2-DC110V_1856388_files/HG2-DC110V_1856388_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00308/img/page/HG2-DC110V_1856388_files/HG2-DC110V_1856388_2.jpg)
HG2-DC6V
Power/Signal Relay, DPDT, Momentary, 0.23A (Coil), 6VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount
PANASONIC
![](http://pdffile.icpdf.com/pdf2/p00259/img/page/HG2-DC6V-F_1564492_files/HG2-DC6V-F_1564492_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00259/img/page/HG2-DC6V-F_1564492_files/HG2-DC6V-F_1564492_2.jpg)
HG2-DC6V-F
Power/Signal Relay, DPDT, Momentary, 0.23A (Coil), 6VDC (Coil), 1400mW (Coil), DC Input, AC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
©2020 ICPDF网 联系我们和版权申明