HHR60AAAH [PANASONIC]

NICKEL METAL HYDRIDE BATTERIES;
HHR60AAAH
型号: HHR60AAAH
厂家: PANASONIC    PANASONIC
描述:

NICKEL METAL HYDRIDE BATTERIES

文件: 总1页 (文件大小:28K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET  
Typical Charge Characteristics  
HHR60AAAHCylindrical AAAsize (HR 11/45)  
Dimensions (with Tube)  
(mm)  
2.0  
1.8  
1.6  
Charge: 50mA x 16 hrs.  
10.5+0  
0.7  
-
1.4  
1.2  
1.0  
0.8  
(+)  
10˚C  
25˚C  
60˚C  
0
2
4
6
8
10  
12  
14  
16  
18  
20  
44.5+0  
1.0  
-
Charge Time (hours)  
Typical Discharge Characteristics  
120  
110  
( )  
100  
90  
Specifications  
80  
mm  
inch  
70  
Diameter  
Height  
10.5 +0/-0.7  
44.5 +0/-1.0  
Grams  
0.41 +0/-0.03  
1.75 +0/-0.04  
Ounces  
60  
Charge: 50mA x 16 hrs.  
Charge Temperature: -10 to 60°C  
Discharge: 100mA  
Cut off Voltage: 1.0V  
Discharge temperature: 25°C  
50  
40  
30  
Approximate  
Weight  
13  
0.46  
-20  
-10  
0
10  
20  
30  
40  
50  
60  
70  
Temperature (°C)  
Nominal Voltage  
1.2V  
550 mAh  
500 mAh  
Average2  
Discharge  
Capacity1  
Rated (Min.)  
Approx. Internal impedance  
at 1000Hz at charged state.  
35m  
Standard  
50mA x 16hrs.  
250mA x 2.4 hrs.4  
25mA x 32 hrs.  
17mA x 48 hrs.  
Rapid3  
Charge  
2.0  
1.8  
1.6  
Charge: 500mA x 16 hrs. 25°C  
Discharge: 100mA  
Low Rate  
C
F
˚
˚
10°C  
25°C  
60°C  
Standard  
Rapid  
14˚F to 140˚F  
-10˚C to 60˚C  
Charge  
14˚F to 113˚F  
14˚F to 140˚F  
-4˚F to 95˚F  
-4˚F to 113˚F  
-4˚F to 131˚F  
-4˚F to 149˚F  
-10˚C to 45˚C  
-10˚C to 60˚C  
-20˚C to 35˚C  
-20˚C to 45˚C  
-20˚C to 55˚C  
-20˚C to 65˚C  
Discharge  
1.4  
1.2  
1.0  
0.8  
< 1 year  
< 6 months  
< 1 month  
< 1 week  
Storage  
1
2
3
After charging at 0.1It for 16 hours, discharging at 0.2It.  
For reference only.  
0
1
2
3
4
5
6
Discharge Time (hours)  
Need specially designed control system  
Control System:  
dT/dt cut-off; 1 to 2°C/min  
-UV cut-off; -UV per cell = 5 to 10 mV  
T-control; T=65°C  
Rapid charger timer; 2.4h (at 1.25a)  
Trickle timer; within 2h  
Note: [It] was previously expressed as [C]. [It] is an IEC standard expression  
for the amount of charge or discharge current and is expressed as:  
It(A) = Cn (Ah)/1h  
4
With control system  
Battery performance and cycle life are strongly affected by how they  
are used. In order to maximize battery safety, please consult Panasonic  
when determining charge / discharge specs, warning label contents  
and unit design.  
* [It] is the reference test current in ampres  
* [Cn] is the rated capacity of the cell or battery in Ampere-hours.  
n = the time base [hours] for which the rated capacity is declared  
AUGUST 2005  
NICKEL METAL HYDRIDE HANDBOOK  
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to  
modification without notice. Contact Panasonic for the latest information.  

相关型号:

HHR70AAAJ

NICKEL METAL HYDRIDE BATTERIES
PANASONIC

HHR75AAA

NICKEL METAL HYDRIDE BATTERIES
PANASONIC

HHS-109

Hybrid Junction 5 - 200 MHz
TE

HHS-109PIN

Hybrid Junction 5 - 200 MHz
TE

HHS-110

Hybrid Junction 10 - 500 MHz
TE

HHS04Z52

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, HALF BRICK-9
BEL

HHS04Z52-T

1-OUTPUT 200W DC-DC REG PWR SUPPLY MODULE, HALF BRICK-9
BEL

HHS04Z527

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, HALF BRICK-9
BEL

HHS04Z528

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, HALF BRICK-9
BEL

HHS04Z52N

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, HALF BRICK-9
BEL

HHS04Z52N7

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, HALF BRICK-9
BEL

HHS04Z52N8

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, HALF BRICK-9
BEL