HJ4-AC100V-6 [PANASONIC]
Power/Signal Relay, 4PDT, Momentary, 1500mW (Coil), 5A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT;型号: | HJ4-AC100V-6 |
厂家: | PANASONIC |
描述: | Power/Signal Relay, 4PDT, Momentary, 1500mW (Coil), 5A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT 光电二极管 继电器 |
文件: | 总9页 (文件大小:443K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TÜV Rheinland
To Be Discontinued
Last time buy: September 30, 2018
Relay for control panel of
2c 7A and 4c 5A
HJ RELAYS
FEATURES
TYPICAL APPLICATIONS
1. Economical prices achieved
2. Useful for wide range of
Control panels
Power supply units
Molding machines
Machine tools
Welding equipment
Agricultural equipment
Office equipment
applications
Gold-plated contact types are capable of
switching under low level (1mA: reference
value) to powerful high level (7A: 2-pole)
loads.
3. Wide range of types available
The lineup includes 2-pole and 4-pole
products, relays with operating indicator
lights, and push-button types.You will
also find relays that absorb surge when
the coil goes to the off state with diodes
(for DC type) or CR circuits (for AC type).
Moreover, the availability of a broad
range of coil voltages meets a wide range
of needs.
Vending machines
Communications equipment
Amusement machines
RoHS compliant
4. Sockets and terminal sockets are
available.
ORDERING INFORMATION
HJ
Contact arrangement
2: 2 Form C
4: 4 Form C
Operation indication
Nil: Without LED indication
L: With LED indication
Test button
Nil: Without a test button
T: With a test button
Nominal coil voltage
AC 12, 24, 48, 100, 120, 200, 220/240 V
DC 12, 24, 48, 110 V
Surge suppression
Nil: Without
D: With diode
R: With CR circuit
Contact surface
Nil: Without Au plating
6: With Au plating
Notes: 1. Certified by UL/C-UL and TÜV
2. The LED indication color is green for the DC coil and red for the AC coil.
ASCTB6E 201709-T
–1–
To Be Discontinued
Last time buy: September 30, 2018
HJ
TYPES
1. Au plating type
1) Plug-in type
2) Plug-in type (with LED indication)
2 Form C
Part No.
4 Form C
Part No.
2 Form C
4 Form C
Part No.
Nominal coil
voltage
Nominal coil
voltage
Part No.
12V DC
24V DC
HJ2-DC 12V-6
HJ2-DC 24V-6
HJ2-DC 48V-6
HJ2-DC110V-6
HJ2-AC 12V-6
HJ2-AC 24V-6
HJ2-AC 48V-6
HJ2-AC100V-6
HJ2-AC120V-6
HJ2-AC200V-6
HJ2-AC220/240V-6
HJ4-DC 12V-6
HJ4-DC 24V-6
HJ4-DC 48V-6
HJ4-DC110V-6
HJ4-AC 12V-6
HJ4-AC 24V-6
HJ4-AC 48V-6
HJ4-AC100V-6
HJ4-AC120V-6
HJ4-AC200V-6
HJ4-AC220/240V-6
12V DC
24V DC
HJ2-L-DC 12V-6
HJ2-L-DC 24V-6
HJ2-L-DC 48V-6
HJ2-L-DC110V-6
HJ2-L-AC 12V-6
HJ2-L-AC 24V-6
HJ2-L-AC 48V-6
HJ2-L-AC100V-6
HJ2-L-AC120V-6
HJ2-L-AC200V-6
HJ2-L-AC220/240V-6
HJ4-L-DC 12V-6
HJ4-L-DC 24V-6
HJ4-L-DC 48V-6
HJ4-L-DC110V-6
HJ4-L-AC 12V-6
HJ4-L-AC 24V-6
HJ4-L-AC 48V-6
HJ4-L-AC100V-6
HJ4-L-AC120V-6
HJ4-L-AC200V-6
HJ4-L-AC220/240V-6
48V DC
48V DC
100/110V DC
12V AC
100/110V DC
12V AC
24V AC
24V AC
48V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
3) Plug-in type (with diode)
4) Plug-in type (with diode and LED indication)
2 Form C
4 Form C
2 Form C
4 Form C
Nominal coil
voltage
Nominal coil
voltage
Part No.
Part No.
Part No.
Part No.
12V DC
24V DC
HJ2-DC 12V-D-6
HJ2-DC 24V-D-6
HJ2-DC 48V-D-6
HJ2-DC110V-D-6
HJ4-DC 12V-D-6
HJ4-DC 24V-D-6
HJ4-DC 48V-D-6
HJ4-DC110V-D-6
12V DC
24V DC
HJ2-L-DC 12V-D-6
HJ2-L-DC 24V-D-6
HJ2-L-DC 48V-D-6
HJ2-L-DC110V-D-6
HJ4-L-DC 12V-D-6
HJ4-L-DC 24V-D-6
HJ4-L-DC 48V-D-6
HJ4-L-DC110V-D-6
48V DC
48V DC
100/110V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
5) Plug-in type (with CR)
6) Plug-in type (with CR and LED indication)
2 Form C
4 Form C
Part No.
2 Form C
4 Form C
Part No.
Nominal coil
voltage
Nominal coil
voltage
Part No.
Part No.
100/110V AC
110/120V AC
200/220V AC
220/240V AC
HJ2-AC100V-R-6
HJ2-AC120V-R-6
HJ2-AC200V-R-6
HJ2-AC220/240V-R-6
HJ4-AC100V-R-6
HJ4-AC120V-R-6
HJ4-AC200V-R-6
HJ4-AC220/240V-R-6
100/110V AC
110/120V AC
200/220V AC
220/240V AC
HJ2-L-AC100V-R-6
HJ2-L-AC120V-R-6
HJ2-L-AC200V-R-6
HJ2-L-AC220/240V-R-6
HJ4-L-AC100V-R-6
HJ4-L-AC120V-R-6
HJ4-L-AC200V-R-6
HJ4-L-AC220/240V-R-6
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2. Without Au plating type
1) Plug-in type
2) Plug-in type (with LED indication)
2 Form C
Part No.
4 Form C
Part No.
2 Form C
4 Form C
Part No.
Nominal coil
voltage
Nominal coil
voltage
Part No.
12V DC
24V DC
HJ2-DC 12V
HJ2-DC 24V
HJ2-DC 48V
HJ2-DC110V
HJ2-AC 12V
HJ2-AC 24V
HJ2-AC 48V
HJ2-AC100V
HJ2-AC120V
HJ2-AC200V
HJ2-AC220/240V
HJ4-DC 12V
HJ4-DC 24V
HJ4-DC 48V
HJ4-DC110V
HJ4-AC 12V
HJ4-AC 24V
HJ4-AC 48V
HJ4-AC100V
HJ4-AC120V
HJ4-AC200V
HJ4-AC220/240V
12V DC
24V DC
HJ2-L-DC 12V
HJ2-L-DC 24V
HJ2-L-DC 48V
HJ2-L-DC110V
HJ2-L-AC 12V
HJ2-L-AC 24V
HJ2-L-AC 48V
HJ2-L-AC100V
HJ2-L-AC120V
HJ2-L-AC200V
HJ2-L-AC220/240V
HJ4-L-DC 12V
HJ4-L-DC 24V
HJ4-L-DC 48V
HJ4-L-DC110V
HJ4-L-AC 12V
HJ4-L-AC 24V
HJ4-L-AC 48V
HJ4-L-AC100V
HJ4-L-AC120V
HJ4-L-AC200V
HJ4-L-AC220/240V
48V DC
48V DC
100/110V DC
12V AC
100/110V DC
12V AC
24V AC
24V AC
48V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
3) Plug-in type (with a test button)
4) Plug-in type (with LED indication and a test button)
2 Form C
4 Form C
Part No.
2 Form C
4 Form C
Nominal coil
voltage
Nominal coil
voltage
Part No.
Part No.
Part No.
12V DC
24V DC
HJ2-T-DC 12V
HJ2-T-DC 24V
HJ2-T-AC100V
HJ2-T-AC200V
HJ4-T-DC 12V
HJ4-T-DC 24V
HJ4-T-AC100V
HJ4-T-AC200V
12V DC
24V DC
HJ2-L-T-DC 12V
HJ2-L-T-DC 24V
HJ2-L-T-AC100V
HJ2-L-T-AC200V
HJ4-L-T-DC 12V
HJ4-L-T-DC 24V
HJ4-L-T-AC100V
HJ4-L-T-AC200V
100/110V AC
200/220V AC
100/110V AC
200/220V AC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
ASCTB6E 201709-T
–2–
To Be Discontinued
Last time buy: September 30, 2018
HJ
5) Plug-in type (with diode)
6) Plug-in type (with diode and LED indication)
2 Form C
4 Form C
2 Form C
4 Form C
Nominal coil
voltage
Nominal coil
voltage
Part No.
Part No.
Part No.
Part No.
12V DC
24V DC
HJ2-DC 12V-D
HJ2-DC 24V-D
HJ2-DC 48V-D
HJ2-DC110V-D
HJ4-DC 12V-D
HJ4-DC 24V-D
HJ4-DC 48V-D
HJ4-DC110V-D
12V DC
24V DC
HJ2-L-DC 12V-D
HJ2-L-DC 24V-D
HJ2-L-DC 48V-D
HJ2-L-DC110V-D
HJ4-L-DC 12V-D
HJ4-L-DC 24V-D
HJ4-L-DC 48V-D
HJ4-L-DC110V-D
48V DC
48V DC
100/110V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
7) Plug-in type (with CR)
8) Plug-in type (with CR and LED indication)
2 Form C
4 Form C
Part No.
2 Form C
4 Form C
Nominal coil
voltage
Nominal coil
voltage
Part No.
Part No.
Part No.
100/110V AC
110/120V AC
200/220V AC
220/240V AC
HJ2-AC100V-R
HJ2-AC120V-R
HJ2-AC200V-R
HJ2-AC220/240V-R
HJ4-AC100V-R
HJ4-AC120V-R
HJ4-AC200V-R
HJ4-AC220/240V-R
100/110V AC
110/120V AC
200/220V AC
220/240V AC
HJ2-L-AC100V-R
HJ2-L-AC120V-R
HJ2-L-AC200V-R
HJ2-L-AC220/240V-R
HJ4-L-AC100V-R
HJ4-L-AC120V-R
HJ4-L-AC200V-R
HJ4-L-AC220/240V-R
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
RATING
1. Coil data
1) AC coils (50/60Hz)
Nominal coil current [ 20%]
Nominal operating power
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. applied voltage
(at 70°C 158°F)
50Hz
60Hz
50Hz
60Hz
12V AC
24V AC
102.9mA
54.5mA
30.7mA
85.4mA
45.6mA
25.9mA
48V AC
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
Approx. 1.2 to
1.5 V A
Approx. 1.0 to
1.3 V A
110%V of
nominal voltage
100/110V AC
110/120V AC
200/220V AC
220/240V AC
11.8mA/13.9mA 10.0mA/11.6mA
10.9mA/12.5mA
6.8mA/8.1mA
6.8mA/7.8mA
9.1mA/10.3mA
5.7mA/6.7mA
5.6mA/6.4mA
2) DC coils
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Coil resistance
(at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 70°C 158°F)
Nominal coil current
12V DC
24V DC
75mA [ 10%]
37mA [ 10%]
160Ω
650Ω
2,600Ω
11,000Ω
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
0.9W
1.1W
110%V of
nominal voltage
48V DC
18mA [ 15%]
100/110V DC
9.1mA/10mA [ 15%]
ASCTB6E 201709-T
–3–
To Be Discontinued
Last time buy: September 30, 2018
HJ
2. Specifications
Characteristics
Item
Specifications
4 Form C
Arrangement
2 Form C
Max. 50 mΩ (By voltage drop 6 V DC 1A)
Au plating type: Au plating Ag Without Au plating type: Ag
Contact
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
7 A 250V AC, 7 A 30V DC
1,750 VA
5 A 250V AC, 5 A 30V DC
1,250 VA
5 A
250V AC, 125V DC
7 A
Rating
Max. switching current*4
Nominal operating power
0.9W 1.2 VA
1mA 1V DC
Au plating type
Min. switching capacity
(Reference value)*1
Without Au plating type
1mA 5V DC
Insulation resistance (Initial)
Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
Between open contacts
Breakdown voltage
(Initial)
Between contact sets
2,000 Vrms for 1min. (Detection current: 10mA.)
Electrical
Between contact and coil
2,000 Vrms for 1min. (Detection current: 10mA.)
characteristics
Temperature rise (coil) (at 70°C 158°F)
Operate time*2
Max. 60°C 140°F (By resistive method, nominal coil voltage)
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Release time*2
Functional
Shock resistance
Min. 100 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 1.0 mm
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Mechanical
Min. 2×107 (at 180 times/min.)
Min. 105 (7A 250V AC)
Min. 5×105 (5A 250V AC)
Min. 105 (7A 30V DC)
Min. 105 (5A 250V AC)
Min. 2×105 (3A 250V AC)
Min. 105 (5A 30V DC)
Expected life
Electrical (resistive load) (at 20 times/min.)
Conditions for operation, transport and storage*3
(Not freezing and condensing at low temperature)
Ambient temperature: –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Unit weight
Max. Operating speed
20 times/min. (at nominal switching capacity)
Approx. 34g 1.20 oz
Notes: In accordance with the Electrical Appliance and Material Safety Law, you cannot exceed a voltage of 150V AC when using the 4 Form C type.
For more information, please inquire.
When using low level loads, contact instability may result depending on conditions of use (switching frequency and ambient conditions, etc.); therefore, please use
the Au plating type.
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using the socket and terminal socket, be sure to verify the max. continuous current.
REFERENCE DATA
1-(1). Max. switching capacity (2 Form C type)
1-(2). Max. switching capacity (4 Form C type)
2-(1). Life curve (2 Form C)
AC resistive load
With test button type only
5
3
10
7
5
500
AC resistive
AC 250V (cosφ =1)
AC resistive
load
load
1
100
50
1
DC resistive load
DC inductive load
0.5
0.1
DC inductive load
L/R=7ms
0.5
AC 250V (cosφ =0.4)
DC resistive load
L/R=7ms
AC inductive load
cos =0.4
AC inductive load
cos =0.4
10
φ
φ
0.1
10
50
100 125 250
10
50
100 125 250
0
1
2
3
4
5
6
7
Contact voltage, V
Contact voltage, V
Load current, A
ASCTB6E 201709-T
–4–
To Be Discontinued
Last time buy: September 30, 2018
HJ
2-(2). Life curve (4 Form C)
3-(1). Coil temperature rise (2 Form C/AC type)
3-(2). Coil temperature rise (2 Form C/DC type)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
70
60
70
500
60
5A
7A
50
40
50
AC 250V (cosφ =1)
100
50
0A
40
0A
30
20
10
0
30
20
10
0
AC 250V (cos
φ
=0.4)
2
10
80
90
100
110
120
80
90
100
110
120
0
1
3
Load current, A
Coil applied voltage, %V
Coil applied voltage, %V
3-(3). Coil temperature rise (4 Form C/AC type)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
3-(4). Coil temperature rise (4 Form C/DC type)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
4-(1). AC coil surge voltage waveform
(With CR circuit)
Tested sample: HJ4-AC200V-R
70
60
70
60
282V
80V
50
50
40
30
20
10
0
5A
0A
7A
40
0A
30
20
10
0
To digital
memory
200V AC
80
90
100
110
120
80
90
100
110
120
Coil applied voltage, %V
Coil applied voltage, %V
4-(2). AC coil surge voltage waveform
(Without CR circuit)
5-(1). DC coil surge voltage waveform
(Without diode)
5-(2). DC coil surge voltage waveform
(With diode)
Tested sample: HJ4-AC200V
Diode characteristics:
Reverse breakdown voltage: 1,000 V
Forward current: 1 A
ON
OFF
ON
OFF
282V
Approx.
260V
Approx.
630V
To digital
memory
12V DC
To digital
memory
To digital
memory
200V AC
12V DC
Reverse breakdown voltage: 1,000 V
Forward current: 1 A
ASCTB6E 201709-T
–5–
To Be Discontinued
Last time buy: September 30, 2018
HJ
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
DIMENSIONS (mm inch)
1. Plug-in type (2 Form C)
(including diode/CR)
External dimensions
Schematic (Bottom view)
CAD Data
Standard type LED AC type LED DC type
Max. 28
1.102
Max. 21.5
.846
1
5
4
8
1
5
4
8
1
5
4
8
9
12
14
9
12
14
9
12
13
13
(–)13
14(+)
Max. 35
1.378
0.5
.020
Diode DC type
CR AC type
1
4
1
4
8
5
9
8
5
9
0.5
.020 5.8
.228
2.5
.098
+0.4
−0.2
12
16.8
.661
12.7
.500
6.4
12
14
+.016
−.008
13
(–)
14
(+)
13
6.8
.268
.252
Diode/LED DC type
CR/LED AC type
1
4
1
4
13.2
.520
5
9
8
5
9
8
12
12
13
(–)
14
(+)
13
14
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
Tolerance
0.1 .004
2. Plug-in type (4 Form C)
(including diode/CR)
External dimensions
Schematic (Bottom view)
CAD Data
Standard type LED AC type LED DC type
Max. 28
1.102
Max. 21.5
.846
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
9
10 11 12
14
9
10 11 12
14
9
10 11 12
13
13
(–)13
14(+)
Max. 35
1.378
0.5
.020
Diode DC type
CR AC type
1
2
3
4
1
2
3
4
5
9
6
7
8
5
9
6
7
8
0.5
2.5
.098
+0.4
.020 5.8
.228
−0.2
10
11
12
16.8
.661
12.7
.500
6.4
10
11
12
14
+.016
−.008
13
(–)
14
(+)
13
6.8
.268
.252
Diode/LED DC type
CR/LED AC type
1
2
3
4
1
2
3
4
4.4 13.2
.173 .520
5
9
6
7
8
5
9
6
7
8
10
11
12
10
11
12
13
(–)
14
(+)
13
14
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
Tolerance
0.1 .004
ASCTB6E 201709-T
–6–
To Be Discontinued
Last time buy: September 30, 2018
HJ
3. Plug-in type with a test button (2 Form C)
CAD Data
External dimensions
Schematic (Bottom view)
Standard type
Max. 28
1.102
Max. 21.5
.846
1
5
4
8
9
12
14
Max. 38
1.496
13
Max. 36
1.417
LED AC type
LED DC type
0.5
.020
1
5
4
8
1
5
4
8
9
12
14
9
12
2.5
.098
0.5
.020
+0.4
5.8
−0.2
13
(–)13
14(+)
16.8
.661
12.7
.500
6.4
+.016
−.008
.228
6.8
.268
.252
Dimension:
Less than 1mm .039inch:
Tolerance
0.1 .004
13.2
.520
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
4. Plug-in type with a test button (4 Form C)
CAD Data
External dimensions
Schematic (Bottom view)
Standard type
Max. 28
1.102
Max. 21.5
.846
1
5
2
6
3
7
4
8
9
10 11 12
14
Max. 38
1.496
13
Max. 36
1.417
LED AC type
LED DC type
0.5
.020
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
9
10 11 12
14
9
10 11 12
14(+)
2.5
.098
0.5
.020
+0.4
13
(–)13
5.8
.228
−0.2
16.8
.661
12.7
.500
6.4
+.016
−.008
6.8
.268
.252
Dimension:
Less than 1mm .039inch:
Tolerance
0.1 .004
4.4 13.2
.173 .520
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
SAFETY STANDARDS
File No.
E43149*
E43149*
Certification authority: UL/C-UL
File No.
Certification authority: TÜV
7A 250V AC (cosφ=1.0), 7A 30V DC (0ms)
Test button type:
10A 250V AC (cosφ=1.0), 10A 30V DC (0ms)
2 Form C
7A 250V AC, 7A 30V DC
R50049126
R50049126
4 Form C
5A 250V AC, 5A 30V DC
5A 250V AC (cosφ=1.0), 5A 30V DC (0ms)
* CSA standard: Certified by C-UL
ASCTB6E 201709-T
–7–
To Be Discontinued
Last time buy: September 30, 2018
HJ
NOTES
1. For cautions for use, please read
“General Application Guidelines”.
2. Coil applied voltage
5. Usage, transport and storage
conditions
1) Temperature, humidity and pressure
during usage, storage and transport
(1) Temperature:
6. Operation method for test button
1) Push and release 1 gently to confirm
relay switching.
1
Please refer to “RATING” about coil input
power supply.
Release
3. LED display
–40 to +70°C –40 to +158°F
(2) Humidity: 5 to 85% RH
Operation is displayed by the light
emitted from the LED. The LED may
remain briefly lit if voltage remains after
the relay opens.
Push
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
Temperature and humidity range for
usage, transport, and storage
4. Switching lifetime
The switching lifetime is defined under
the standard test condition specified in
the JIS* C 5442 standard (temperature
15 to 35°C 59 to 95°F, humidity 25 to
75%). Check this with the real device as it
is affected by coil driving circuit, load
type, activation frequency, activation
phase,ambient conditions and other
factors.
Also, be especially careful of loads such
as those listed below.
1) When used for AC load-operating and
the operating phase is synchronous.
Rocking and fusing can easily occur due
to contact shifting.
2) High-frequency load-operating
When high-frequency opening and
closing of the relay is performed with a
load that causes arcs at the contacts,
nitrogen and oxygen in the air is fused by
the arc energy and HNO3 is formed. This
can corrode metal materials.
Humidity, %R.H.
2) To lock to one side turn 90° counter-
clockwise while pushing lock and turn 90°
clockwise to release.
85
Tolerance range
(Avoid freezing (Avoid
For Lock
For Release
when used at
temperatures
lower than
0°C 32°F)
condensation
when used at
temperatures
higher than
0°C 32°F)
5
–40
–40
0
70
+158
+32
Temperature, °C °F
(3) Atmospheric pressure: 86 to 106 kPa
2) Condensation
3) Do not use the test button for anything
other than testing, such as when
checking the circuit.
7. Diode characteristics
1) Reverse breakdown voltage: 1,000 V
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
3) Freezing
2) Forward current:
1 A
8. Diode and CR built-in type
Three countermeasures for these are
listed here.
(1) Incorporate an arc-extinguishing
circuit.
(2) Lower the operating frequency
(3) Lower the ambient humidity
Condensation or other moisture may
freeze on the relay when the
Since the diode and CR inside the relay
coil are designed to absorb the counter
emf, the element may be damaged if a
large surge, etc., is applied to the diode
and CR. If there is the possibility of a
large surge voltage from the outside,
please implement measures to absorb it.
9. Please connect DC coil types with
LED and built-in diode correctly by
verifying the coil polarity (“+” and “–
”). Connecting with reverse polarity
will cause the LED not to light and
damage the built-in diode due to its
specification.
temperatures is lower than 0°C 32°F.This
causes problems such as sticking of
movable parts or operational time lags.
4) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
ASCTB6E 201709-T
–8–
相关型号:
HJ4-AC100V-R
Power/Signal Relay, 4PDT, Momentary, 1500mW (Coil), 5A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
HJ4-AC200V-R-6
Power/Signal Relay, 4PDT, Momentary, 1500mW (Coil), 5A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
HJ4-AC220/240V
Power/Signal Relay, 4PDT, Momentary, 1500mW (Coil), 5A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
HJ4-AC48V
Power/Signal Relay, 4PDT, Momentary, 1500mW (Coil), 5A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
HJ4-DC110V
Power/Signal Relay, 4PDT, Momentary, 0.01A (Coil), 110VDC (Coil), 1100mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
HJ4-DC12V
Power/Signal Relay, 4PDT, Momentary, 0.075A (Coil), 12VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
HJ4-DC12V-D
Power/Signal Relay, 4PDT, Momentary, 0.075A (Coil), 12VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
HJ4-DC24V
Power/Signal Relay, 4PDT, Momentary, 0.037A (Coil), 24VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
HJ4-DC24V-D
Power/Signal Relay, 4PDT, Momentary, 0.037A (Coil), 24VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
HJ4-DC48V
Power/Signal Relay, 4PDT, Momentary, 0.018A (Coil), 48VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
HJ4-DC48V-D-6
Power/Signal Relay, 4PDT, Momentary, 0.018A (Coil), 48VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
©2020 ICPDF网 联系我们和版权申明