HL1-H-AC12V-F [PANASONIC]
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Panel Mount, ROHS COMPLIANT;型号: | HL1-H-AC12V-F |
厂家: | PANASONIC |
描述: | Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Panel Mount, ROHS COMPLIANT 光电二极管 继电器 |
文件: | 总8页 (文件大小:424K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
To Be Discontinued
Last time buy: September 30, 2018
Relay for control panel of
1c 15A, and 2c 10A
HL RELAYS
FEATURES
TYPICAL APPLICATIONS
1. Compact high-capacity control relay
In the same external dimensions as an
HC relay, this compact power relay
enables high-capacity control:
15 A for 1 Form C, 10 A for 2 Form C.
2. Designed for high reliability
High operational reliability is achieved by
solder-less construction, in which all
connections between lead wires and the
contact springs and terminal plate are
welded.
1. Factory automation equipment and
automotive devices
2. Control panels, power supply
equipment, molding equipment,
machine tools, welding equipment,
agricultural equipment, etc.
3. Office equipment, automatic
vending machines,
telecommunications equipment,
disaster prevention equipment,
copiers, measuring devices, medical
equipment, amusement devices, etc.
4. All types of household appliance
3. Various types provided in rich
lineup. LED indicator and diode type
is also available.
4.The terminals are compatible with
#187 series tab terminals.
5. Sockets and terminal sockets are
available.
RoHS compliant
ORDERING INFORMATION
HL
F
Contact arrangement
1: 1 Form C
2: 2 Form C
Terminal arrangement
H:
L:
Plug-in type
Plug-in type with LED indication
HP: PC board type
PL: PC board type with LED indication
HTM: TM type
Nominal coil voltage
AC 6, 12, 24, 48, 100 (100/110), 120 (110/120),
200 (200/220), 240 (220/240) V
DC 6, 12, 24, 48, 100 (100/110) V
Surge absorber
*D: with diode
Contact material
F: AgSnO2 type
Notes: 1. Certified by C-UL, CSA and TÜV
Please inquire about TV approved products.
2. *Diode type is available. (DC coil Plug-in type with LED indication only)
3. The LED indication color is green for the DC coil and red for the AC coil.
ASCTB114E 201709-T
–1–
To Be Discontinued
Last time buy: September 30, 2018
HL
TYPES
1. Plug-in type
2. Plug-in type (with LED indication)
1 Form C
2 Form C
1 Form C
2 Form C
Nominal coil
voltage
Nominal coil
voltage
Part No.
Part No.
Part No.
Part No.
6V AC
12V AC
HL1-H-AC6V-F
HL1-H-AC12V-F
HL1-H-AC24V-F
HL1-H-AC48V-F
HL1-H-AC100V-F
HL1-H-AC120V-F
HL1-H-AC200V-F
HL1-H-AC240V-F
HL1-H-DC6V-F
HL1-H-DC12V-F
HL1-H-DC24V-F
HL1-H-DC48V-F
HL1-H-DC100V-F
HL2-H-AC6V-F
HL2-H-AC12V-F
HL2-H-AC24V-F
HL2-H-AC48V-F
HL2-H-AC100V-F
HL2-H-AC120V-F
HL2-H-AC200V-F
HL2-H-AC240V-F
HL2-H-DC6V-F
HL2-H-DC12V-F
HL2-H-DC24V-F
HL2-H-DC48V-F
HL2-H-DC100V-F
6V AC
12V AC
HL1-L-AC6V-F
HL1-L-AC12V-F
HL1-L-AC24V-F
HL1-L-AC48V-F
HL1-L-AC100V-F
HL1-L-AC120V-F
HL1-L-AC200V-F
HL1-L-AC240V-F
HL1-L-DC6V-F
HL1-L-DC12V-F
HL1-L-DC24V-F
HL1-L-DC48V-F
HL1-L-DC100V-F
HL2-L-AC6V-F
HL2-L-AC12V-F
HL2-L-AC24V-F
HL2-L-AC48V-F
HL2-L-AC100V-F
HL2-L-AC120V-F
HL2-L-AC200V-F
HL2-L-AC240V-F
HL2-L-DC6V-F
HL2-L-DC12V-F
HL2-L-DC24V-F
HL2-L-DC48V-F
HL2-L-DC100V-F
24V AC
24V AC
48V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
12V DC
24V DC
24V DC
48V DC
48V DC
100/110V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
3. Plug-in type (with LED indication and diode)
4. PC board type
1 Form C
2 Form C
1 Form C
2 Form C
Nominal coil
voltage
Nominal coil
voltage
Part No.
Part No.
Part No.
Part No.
6V DC
12V DC
HL1-L-DC6V-D-F
HL1-L-DC12V-D-F
HL1-L-DC24V-D-F
HL1-L-DC48V-D-F
HL1-L-DC100V-D-F
HL2-L-DC6V-D-F
HL2-L-DC12V-D-F
HL2-L-DC24V-D-F
HL2-L-DC48V-D-F
HL2-L-DC100V-D-F
6V AC
12V AC
HL1-HP-AC6V-F
HL1-HP-AC12V-F
HL1-HP-AC24V-F
HL1-HP-AC48V-F
HL1-HP-AC100V-F
HL1-HP-AC120V-F
HL1-HP-AC200V-F
HL1-HP-AC240V-F
HL1-HP-DC6V-F
HL1-HP-DC12V-F
HL1-HP-DC24V-F
HL1-HP-DC48V-F
HL1-HP-DC100V-F
HL2-HP-AC6V-F
HL2-HP-AC12V-F
HL2-HP-AC24V-F
HL2-HP-AC48V-F
HL2-HP-AC100V-F
HL2-HP-AC120V-F
HL2-HP-AC200V-F
HL2-HP-AC240V-F
HL2-HP-DC6V-F
HL2-HP-DC12V-F
HL2-HP-DC24V-F
HL2-HP-DC48V-F
HL2-HP-DC100V-F
24V DC
24V AC
48V DC
48V AC
100/110V DC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
12V DC
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
5. PC board type (with LED indication)
6.TM type
1 Form C
2 Form C
1 Form C
2 Form C
Nominal coil
voltage
Nominal coil
voltage
Part No.
Part No.
Part No.
Part No.
6V AC
12V AC
HL1-PL-AC6V-F
HL1-PL-AC12V-F
HL1-PL-AC24V-F
HL1-PL-AC48V-F
HL1-PL-AC100V-F
HL1-PL-AC120V-F
HL1-PL-AC200V-F
HL1-PL-AC240V-F
HL1-PL-DC6V-F
HL1-PL-DC12V-F
HL1-PL-DC24V-F
HL1-PL-DC48V-F
HL1-PL-DC100V-F
HL2-PL-AC6V-F
HL2-PL-AC12V-F
HL2-PL-AC24V-F
HL2-PL-AC48V-F
HL2-PL-AC100V-F
HL2-PL-AC120V-F
HL2-PL-AC200V-F
HL2-PL-AC240V-F
HL2-PL-DC6V-F
HL2-PL-DC12V-F
HL2-PL-DC24V-F
HL2-PL-DC48V-F
HL2-PL-DC100V-F
6V AC
12V AC
HL1-HTM-AC6V-F
HL1-HTM-AC12V-F
HL1-HTM-AC24V-F
HL1-HTM-AC48V-F
HL1-HTM-AC100V-F
HL1-HTM-AC120V-F
HL1-HTM-AC200V-F
HL1-HTM-AC240V-F
HL1-HTM-DC6V-F
HL1-HTM-DC12V-F
HL1-HTM-DC24V-F
HL1-HTM-DC48V-F
HL1-HTM-DC100V-F
HL2-HTM-AC6V-F
HL2-HTM-AC12V-F
HL2-HTM-AC24V-F
HL2-HTM-AC48V-F
HL2-HTM-AC100V-F
HL2-HTM-AC120V-F
HL2-HTM-AC200V-F
HL2-HTM-AC240V-F
HL2-HTM-DC6V-F
HL2-HTM-DC12V-F
HL2-HTM-DC24V-F
HL2-HTM-DC48V-F
HL2-HTM-DC100V-F
24V AC
24V AC
48V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
12V DC
24V DC
24V DC
48V DC
48V DC
100/110V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
ASCTB114E 201709-T
–2–
To Be Discontinued
Last time buy: September 30, 2018
HL
RATING
1. Coil data
1) AC coils
Nominal coil current
(mA)
Nominal operating power
(VA)
Max. applied
voltage
(at 70°C 158°F)
Inductance (H)
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
50Hz
224
60Hz
200
50Hz
60Hz
When drop-out When operating
6V AC
12V AC
0.078
0.312
1.243
4.974
23.75
27.19
85.98
0.074
0.295
1.181
4.145
20.63
25.57
81.76
111
100
24V AC
56
50
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
48V AC
28
25
1.3
1.2
100/110V AC
110/120V AC
200/220V AC
13.4/14.7
12.2/13.5
6.7/7.4
12/13.2
10.9/11.9
6/6.6
Notes: 1. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
In particular, for AC operation, if the applied voltage drops to 80% V or more below the nominal voltage, humming will occur and a large current will flow leading
possibly to coil burnout.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2) DC coils (at 20°C 68°F)
Nominal coil
Nominal coil current
Nominal operating
power (W)
Coil resistance
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. applied voltage
(at 70°C 158°F)
voltage
(mA)
(Ω)
6V DC
12V DC
150
75
40
160
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
0.9
110%V of
nominal voltage
24V DC
37
650
48V DC
18.5
10
2,600
10,000
100/110V DC
1.0
Notes: 1. The nominal operating current is 10% (20°C 68°F).
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate 0.4% for every 1°C change in temperature.
3. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
nominal voltage.
4. For use with 200 V DC, connect a 10 KΩ (5W) resistor, in series, to the 100 V DC relay.
5. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2. Specifications
Characteristics
Item
Contact resistance (Initial)
Contact material
Specifications
Max. 50 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
Contact
1 Form C: 15A 125V AC, 10A 250V AC (resistive load)
2 Form C: 10A 250V AC (resistive load)
Nominal switching capacity*4
Rating
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
100mA 5V DC
Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
2,000 Vrms for 1min. (Detection current: 10mA)
Max. 80°C 176°F (By resistive method, nominal voltage)
Between open contacts
Breakdown voltage
Between contact sets
(Initial)
Between contact and coil
Temperature rise (coil)
Electrical
characteristics
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Operate time (at 20°C 68°F)*2
Release time (at 20°C 68°F)*2
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Functional
Shock resistance
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 2 mm
Mechanical
AC type: 5×107 (at 180 times/min.), DC type: 108 (at 180 times/min.)
1 Form C: 15A 125V AC, 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
AC load
Electrical
Expected life
2 Form C: 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 3×105
1 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
2 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
DC load
Ambient temperature: –50°C to +70°C –58°F to +158°F (Without LED indication);
Conditions for operation, transport and storage*3 –50°C to +60°C –58°F to +140°F (With LED indication)
Conditions
Unit weight
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at max. rating)
Approx. 35g 1.23 oz
Max. Operating speed
Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature
between –50°C to +40°C –58°F to +104°F (AC type).
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using the socket, be sure to verify the max. continuous current.
ASCTB114E 201709-T
–3–
To Be Discontinued
Last time buy: September 30, 2018
HL
REFERENCE DATA
Switching capacity range (1 Form C)
Switching capacity range (2 Form C)
AC resistive load
AC resistive load
15
10
10
AC inductive
load (cosϕ=0.4)
AC inductive
load (cosϕ=0.4)
DC resistive
load
DC resistive
load
DC inductive
load (L/R=7ms)
DC inductive
load (L/R=7ms)
1
1
0.1
0.1
10
100
500 1,000
10
100
500 1,000
Contact voltage, V
Contact voltage, V
With diode type (For DC)
1. DC coil surge voltage waveform
(without diode)
2. DC coil surge voltage waveform
(with diode)
Diode characteristics;
Reverse breakdown voltage: 1,000V,
Forward current: 1A
ON
OFF
ON
OFF
260V
+
To digital
memory
12V DC
+
–
To digital
memory
12V DC
–
Reverse breakdown voltage: 1,000 V
Forward current: 1 A
(
(
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
DIMENSIONS (mm inch)
1. Plug-in type
1 Form C
External dimensions
Schematic (Bottom view)
Standard type
With diode type
20.8
27.2
1.071
CAD Data
.819
2
2
3
3
6
6
(−)
(+)
7
8
35.4
7
8
1.394
1.2
.047
6.35
.250
LED AC type
LED DC type
0.5
.020
2
6
2
6
Compatible with tab terminal
#187 series receptacle.
3
3
10
.394
7
∼
7
3.75
8
∼
8
(+)
2
6
(
)
(−)
.148
4.6
(
)
3
.181
6
.236
7.15
.281
7
8
14.2
.559
General tolerance: 0.3 .012
ASCTB114E 201709-T
–4–
To Be Discontinued
Last time buy: September 30, 2018
HL
2 Form C
External dimensions
Schematic (Bottom view)
Standard type
With diode type
20.8
.819
27.2
1.071
CAD Data
1
3
5
2
4
6
1
3
2
4
5
6
7
8
(−)
(+)
35.4
7
8
1.394
1.2
.047
6.35
.250
LED AC type
LED DC type
0.5
.020
1
3
5
2
4
6
1
3
5
2
4
6
Compatible with tab terminal
#187 series receptacle.
10
.394
7
∼
7
3.7
.146
8
∼
8
(+)
(
)
(−)
1
3
2
(
)
4.7
4
.185
6
6
5
.236
7.3
.287
7
8
14.2
.559
General tolerance: 0.3 .012
2. PC board type
1 Form C
External dimensions
Schematic (Bottom view)
Standard type
20.8
.819
27.2
1.071
CAD Data
2
3
6
7
8
35.4
1.394
LED AC type
LED DC type
2
6
2
6
1.2
.047
3
3
5
.197
3.5
.138
1.5
0.5
.059
.020
7
∼
7
8
∼
8
(+)
(
)
(−)
(
)
10
.394
3.75
.148
4.6
2
6
3
.181
6
PC board pattern (Bottom view)
.236
5-2 dia. hole
7.15
10
5-.079 dia.
.281
R3
7
8
.394
R.118
4.6
.181
17.75
.699
14.2
.559
6
R2
General tolerance: 0.3 .012
.236
8.5
R.079
.335
4
.157
7.15
.281
14.2
.559
Tolerance: 0.1 .004
ASCTB114E 201709-T
–5–
To Be Discontinued
Last time buy: September 30, 2018
HL
2 Form C
External dimensions
Schematic (Bottom view)
Standard type
20.8
.819
CAD Data
27.2
1.071
1
3
5
2
4
6
7
8
35.4
1.394
LED AC type
LED DC type
1
3
5
2
4
6
1
3
5
2
4
6
1.2
.047
5
.197
3.5
.138
0.5
1.5
7
∼
7
.020
.059
8
∼
8
(+)
(
)
(−)
(
)
10
.394
3.7
.146
4.7
.185
6
1
3
2
4
PC board pattern (Bottom view)
6
5
8-2 dia. hole
.236
8-.079 dia.
10
7.3
.394
.287
7
8
1.25
.049
1.25
.049
2
18
.709
13.3
.524
R2
.079
R.079
1.25
14.2
.559
2
.049
General tolerance: 0.3 .012
.079
4.157
4
4
R2
R.079
7.3
.287
14.2
.559
Tolerance: 0.1 .004
3.TM type
1 Form C
External dimensions
Schematic (Bottom view)
Standard type
43
1.693
CAD Data
20.6
.811
2
2
3
.079
6
7
8
34.4
1.354
Chassis (Panel) cutout
in tandem mounting
Chassis (Panel) cutout
1.2
.047
6.35
23
.250
.906
2-3.2 to 3.5 dia. hole
2-.126 to .138 dia.
0.5
.020
Compatible with tab terminal
#187 series receptacle.
37.6
1.470
37.6
3.6
1.470
.142
21
21
.827
.827
2
Tolerance: 0.1 .004
.079
3.75
.148
4.6
2
3
.181
6
Notes: 1. If connecting to #187 series tab terminals, use AMP Faston
#187 series or #187 tab terminals conforming to UL or CSA
inch-standard dimensions.
6
37.6
.236
1.480
7.15
.281
7
8
2. In mounting, use M3 screws and M3 washers.
3. When mountingTM types, use washers to prevent damage
or distortion to the polycarbonate cover.
4. When tightening fixing screws, the optimum torque range
should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm).Moreover, use
washers to prevent loosening.
General tolerance: 0.3 .012
ASCTB114E 201709-T
–6–
To Be Discontinued
Last time buy: September 30, 2018
HL
2 Form C
CAD Data
External dimensions
Schematic (Bottom view)
Standard type
43
1.693
20.6
.811
1
3
5
2
4
6
2
.079
7
8
34.4
1.354
Chassis (Panel) cutout
in tandem mounting
Chassis (Panel) cutout
1.2
.047
6.35
23
.250
.906
2-3.2 to 3.5 dia. hole
2-.126 to .138 dia.
0.5
.020
37.6
Compatible with tab terminal
#187 series receptacle.
1.470
3.6
37.6
.142
1.470
21
21
.827
.827
2
Tolerance: 0.1 .004
.079
3.7
.146
4.7
.185
6
1
3
2
4
6
Notes: 1. If connecting to #187 series tab terminals, use AMP Faston
#187 series or #187 tab terminals conforming to UL or CSA
inch-standard dimensions.
37.6
5
.236
1.480
7.3
.287
7
8
2. In mounting, use M3 screws and M3 washers.
3. When mountingTM types, use washers to prevent damage
or distortion to the polycarbonate cover.
4. When tightening fixing screws, the optimum torque range
should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm).Moreover, use
washers to prevent loosening.
General tolerance: 0.3 .012
SAFETY STANDARDS
1. Standard type (Plug-in type except with diode, PC board type,TM type)
UL/C-UL (Recognized)
CSA (Certified)
TV rating (UL/CSA)
File No. Rating
UL: E43149 NO➝TV-5
CSA: LR26550 NC➝TV-2
etc.
TÜV rating
Rating
Contact
arrangement
File No. Contact rating
File No.
—
Contact rating
File No.
B1305
13461 341
E43028*1
E43028*1
15A 250V AC
CSA standard
certified by C-UL
15A 125V AC (cosφ=1.0)
10A 250V AC (cosφ=1.0)
10A 30V DC (L/R=0ms)
1 Form C
2 Form C
1/3HP 125, 250V AC
10A 30V DC
10A 250V AC
CSA standard
certified by C-UL
UL: E43149
NO➝TV-4
B1305
13461 341
10A 250V AC (cosφ=1.0)
10A 30V DC (L/R=0ms)
1/3HP 125, 250V AC
10A 30V DC
—
CSA: LR26550 NC➝TV-2
etc.
2. Plug-in type (with diode)*2
UL/C-UL (Recognized)
CSA (Certified)
Contact rating
TV rating (UL/CSA)
TÜV rating
Rating
Contact
arrangement
File No.
Contact rating
File No.
—
File No.
Rating
File No.
E43028*1
15A 250V AC
CSA standard
certified by C-UL
B1305
13461 341
15A 125V AC (cosφ=1.0)
10A 250V AC (cosφ=1.0)
10A 30V DC (L/R=0ms)
1 Form C
2 Form C
1/3HP 125, 250V AC
—
—
10A 30V DC
E43028*1
10A 250V AC
CSA standard
certified by C-UL
B1305
13461 341
10A 250V AC (cosφ=1.0)
10A 30V DC (L/R=0ms)
1/3HP 125, 250V AC
10A 30V DC
—
—
—
Note: “*1” indicates the UL/C-UL recognition file number.
“*2” DC coil Plug-in type with LED indication only.
NOTES
1. For cautions for use, please read
“General Application Guidelines”.
ASCTB114E 201709-T
–7–
相关型号:
HL1-H-AC200V-F
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Panel Mount, ROHS COMPLIANT
PANASONIC
HL1-H-AC240V
Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount
PANASONIC
HL1-H-AC24V
Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount,
PANASONIC
HL1-H-AC24V-F
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Panel Mount, ROHS COMPLIANT
PANASONIC
HL1-H-AC48V
Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount,
PANASONIC
HL1-H-AC48V-F
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Panel Mount, ROHS COMPLIANT
PANASONIC
HL1-H-AC6V
Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount
PANASONIC
HL1-H-AC6V-F
POWER/SIGNAL RELAY, SPDT, MOMENTARY, 1300mW (COIL), 15A (CONTACT), 30VDC (CONTACT), PANEL MOUNT, ROHS COMPLIANT
PANASONIC
©2020 ICPDF网 联系我们和版权申明