HY1-12 [PANASONIC]
Electromechanical Relay, SPDT, Latched, 16.8VDC (Coil), 1A (Contact), 60VDC (Contact), Random, DC Output;型号: | HY1-12 |
厂家: | PANASONIC |
描述: | Electromechanical Relay, SPDT, Latched, 16.8VDC (Coil), 1A (Contact), 60VDC (Contact), Random, DC Output 光电二极管 |
文件: | 总4页 (文件大小:1456K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Non-polarized 1 Form C
relay that realizes nominal
operating power of 150 mW
HY RELAYS
FEATURES
TYPICAL APPLICATIONS
1. Nominal operating power:
High sensitivity of 150mW (Single
side stable type)
1. Automotive equipment
Automirrow controller
A nominal operating power of 150 mW
(minimum operating power of 84 mW)
has been achieved.
2. The use of gold-clad twin contacts
ensures high contact reliability.
3. Sealed construction
Retractable head light controller
2. Push button device: Dial pulsing
3. Portable video tape recorders and
audio devices
4. Computer peripherals
4. Sealed according to RTIII (IP67)
ORDERING INFORMATION
HY
1
Contact arrangement
1: 1 Form C
Sensitivity
Nil: High sensitivity 150 mW
Z: Standard 200 mW
Nominal coil voltage (DC)
1.5, 3, 4.5, 5, 6, 9, 12, 24 V
Note: In case of 5 V drive circuit, it is recommended to use 4.5 V type relay.
TYPES
150mW type
Part No.
HY1-1.5V
HY1-3V
200mW type
Part No.
Contact
Nominal coil
voltage
arrangement
1.5V DC
3V DC
HY1Z-1.5V
HY1Z-3V
HY1Z-4.5V
HY1Z-5V
HY1Z-6V
HY1Z-9V
HY1Z-12V
HY1Z-24V
4.5V DC
5V DC
HY1-4.5V
HY1-5V
1 Form C
6V DC
HY1-6V
9V DC
HY1-9V
12V DC
24V DC
HY1-12V
HY1-24V
Standard packing: Tube: 50 pcs.; Case: 2,000 pcs.
ds_61012_en_hy: 280114D
1
HY
RATING
1. Coil data
Nominal operating
current
[10%] (at 20C 68F)
Max. applied
voltage
(at 70C 158F)
Contact
arrangement
Nominal coil
voltage
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
1.5V DC
3V DC
100mA
50mA
15
60
4.5V DC
5V DC
33.3mA
30mA
135
166
240
540
960
3,840
11.25
45
75%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
140%V of
nominal voltage
150mW
6V DC
25mA
9V DC
16.7mA
12.5mA
6.25mA
133.3mA
66.7mA
44.5mA
40mA
12V DC
24V DC
1.5V DC
3V DC
1 Form C
4.5V DC
5V DC
101.2
125
180
405
720
2,880
75%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
120%V of
nominal voltage
200mW
6V DC
33.3mA
22.2mA
16.7mA
8.3mA
9V DC
12V DC
24V DC
2. Specifications
Characteristics
Item
Specifications
Arrangement
1 Form C
Contact
Initial contact resistance, max.
Contact material
Max. 100 m (By voltage drop 6 V DC 1A)
Ag+Au clad
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. carrying current
Max. switching current
1 A 30 V DC (resistive load)
30 W (DC) (resistive load)
60 V DC
Rating
2 A
1 A (30 V DC)
Min. switching capacity (Reference value)*1
1mA 1 V DC
Nominal operating power
150/200mW
Min. 100M (at 500V DC)
Insulation resistance (Initial)
Measurement at same location as “Initial breakdown voltage” section.
500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
Max. 50C
Between open contacts
Between contact and coil
Breakdown voltage
(Initial)
Electrical
characteristics
Temperature rise (at 20C 68F)
(By resistive method, nominal coil voltage applied to the coil, nominal switching capacity.)
Operate time [Set time] (at 20C 68F)
Release time [Reset time] (at 20C 68F)
Max. 5 ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 4 ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Functional
Shock resistance
Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10s.)
10 to 55 Hz at double amplitude of 2 mm
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Mechanical
Electrical
Min. 107 (at 180 times/min.)
Min. 105 (1 A 30 V DC resistive) (at 20 times/min.)
Expected life
Ambient temperature: –40C to +70C –40F to +158F
Conditions for operation, transport and storage*2
Max. operating speed (at rated load)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Unit weight
20 times/min.
Approx. 1.8 g .063 oz
*1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
ds_61012_en_hy: 280114D
2
HY
REFERENCE DATA
1. Maximum switching power
2. Life curve
3. Mechanical life
Tested sample: HY1Z-12V, 10 pcs.
Ambient temperature: 20C to 25C 68F to 77F
100
90
5.0
300
200
30 V DC
DC resistive
AC resistive
resistive load
80
100
2.0
1.0
70
50
Pick-up voltage
60
30
20
Max.
50
40
30
20
10
0
Min.
10
0.5
0.2
Drop-out voltage
100 V AC
resistive load
Max.
Min.
0.1
0.2 0.4 0.6 0.8 1.0 1.2 1.4
Switching current, A
10
30
60 100
300
10
100
1,000 2,000
Contact voltage, V
No. of operations, ×104
4. Electrical life
Change of pick-up and drop-out voltage
Change of contact resistance
Tested sample: HY1-12V, 6 pcs.
Condition: 1 A 30 V DC resistive load, 30 times/min.
100
90
80
60
40
20
Pick-up voltage
Drop-out voltage
80
70
60
50
40
30
20
10
0
Max.
Min.
Max.
Min.
Max.
Min.
0
10
20
No. of operations, × 104
10
20
No. of operations, ×104
5-(1). Coil temperature rise
(150 mW high sensitivity type)
Tested sample: HY1-9V, 5 pcs.
5-(2). Coil temperature rise
(200 mW Standard type)
Tested sample: HY1Z-12V, 5 pcs.
6. Operate/release time characteristics
Tested sample: HY1Z-12V, 5 pcs.
Ambient temperature: 25C 77F
Ambient temperature:24C 75F
Ambient temperature: 23C 74F
3
100
90
100
90
80
80
1A
Operate time
2
70
60
50
40
30
20
10
0
70
1A
60
0A
50
40
30
20
10
0
0A
Max.
x
Min.
1
0
Release time
Max.
x
Min.
80
100
120
80
100 120
140
160
180
80
100 120
140
160
180
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
7. Distribution of pick-up and drop-out voltages
8. Distribution of contact resistance
9. Malfunction shock
Tested sample: HY1-12V, 50 pcs.
Ambient temperature: 23C 74F
Tested sample: HY1-12V, 50 pcs.
N.C. side N.O. side
Tested sample: HY1Z-12V, 6 pcs.
30
30
N.C. side
N.O. side
Deenergized condition
Energized condition
XX’
Z
Y
980m/s2
Z’
Drop-out voltage
25
25
20
15
10
5
Y
Y’
980m/s2
X
20
Z
980m/s2
Pick-up voltage
15
10
5
980m/s2
Z’
980m/s2
X’
980m/s2
Y’
0
0
30
40
Contact resistance mΩ
10 20 30 40 50 60 70 80 90 100
Pick-up/drop-out voltage, V
ds_61012_en_hy: 280114D
3
HY
DIMENSIONS (mm inch)
Download CADData from our Web site.
External dimensions
PC board pattern (Bottom view)
CAD Data
7.4
12
6-1 dia.
2.54
.100
7.62
.300
.291
.462
6-.039 dia.
10.1
.398
5.08
.200
2.54
.100
3.5
0.5
.138
0.5
.020
(0.82)
(.032)
0.4 dia.
.020
.016 dia.
5.08
.200
0.25
.010
2.54
.100
0.25
Tolerance: 0.1 .004
.010
7.62
.300
(0.82)
(.032)
Schematic (Bottom view)
1
2
5
General tolerance: 0.3 .012
NC
NO
COM
10
9
6
NOTE
1. Packing style
2. Automatic insertion
1) As shown in the diagram below, the
relays are presented in tube packages
with pins 1 and 10 on the left. Be sure to
maintain relays in the correct orientation
when mounting on PC boards.
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
4.9 N {500gf} or less
Side with pins 1 and 10.
Chucking pressure in the direction C:
4.9 N {500gf} or less
C
A
B
Stopper
(gray)
Stopper
(green)
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
For Cautions for Use, see Relay Technical Information.
ds_61012_en_hy: 280114D
4
相关型号:
HY1-24
Electromechanical Relay, SPDT, Latched, 33.6VDC (Coil), 1A (Contact), 60VDC (Contact), Random, DC Output
PANASONIC
HY1-4.5
Electromechanical Relay, SPDT, Latched, 6.3VDC (Coil), 1A (Contact), 60VDC (Contact), Random, DC Output
PANASONIC
HY1-5
Electromechanical Relay, SPDT, Latched, 7VDC (Coil), 1A (Contact), 60VDC (Contact), Random, DC Output
PANASONIC
©2020 ICPDF网 联系我们和版权申明