JQ1A-P-48V-F [PANASONIC]

Electromechanical Relay, SPST, Latched, 86.4VDC (Coil), 10A (Contact), 110VDC (Contact), Random, AC/DC Output;
JQ1A-P-48V-F
型号: JQ1A-P-48V-F
厂家: PANASONIC    PANASONIC
描述:

Electromechanical Relay, SPST, Latched, 86.4VDC (Coil), 10A (Contact), 110VDC (Contact), Random, AC/DC Output

PC 继电器
文件: 总6页 (文件大小:1768K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VDE  
1a/1c 5A/10A small power  
relays  
JQ RELAYS  
FEATURES  
TYPICAL APPLICATIONS  
• High electrical noise immunity  
• High switching capacity in a compact  
package  
• Air conditioners  
• Refrigerators  
• Microwave ovens  
• Heaters  
• High sensitivity: 200 mW (1a),  
400 mW (1c)  
• High surge voltage: 8,000 V between  
contacts and coil  
• UL, CSA, VDE, SEMKO approved and  
TÜV available  
• Class B coil insulation type also  
available.  
• High insulation resistance:  
Creepage distance and clearance  
between contact and coil:  
Min. 4 mm .157 inch  
ORDERING INFORMATION  
JQ  
F
Contact arrangement  
1a: 1 Form A  
1 : 1 Form C  
Contact capacity  
Nil: Standard (5A)  
P: High capacity (10A)  
Coil insulation class  
Nil: Class E coil insulation  
B: Class B coil insulation (UL)  
Nominal coil voltage (DC)  
5V, 6V, 9V, 12V, 18V, 24V, 48V*  
Contact material  
F: AgSnO2 type  
Certified by UL, CSA, VDE and SEMKO  
Note: *Available only for 1 Form C type  
TYPES  
1) Standard type  
Standard type  
High capacity type  
1 Form C  
Nominal coil voltage  
1 Form A  
Part No.  
1 Form C  
Part No.  
1 Form A  
Part No.  
Part No.  
5V DC  
6V DC  
JQ1a-5V-F  
JQ1a-6V-F  
JQ1a-9V-F  
JQ1a-12V-F  
JQ1a-18V-F  
JQ1a-24V-F  
JQ1-5V-F  
JQ1-6V-F  
JQ1-9V-F  
JQ1-12V-F  
JQ1-18V-F  
JQ1-24V-F  
JQ1-48V-F  
JQ1aP-5V-F  
JQ1aP-6V-F  
JQ1aP-9V-F  
JQ1aP-12V-F  
JQ1aP-18V-F  
JQ1aP-24V-F  
JQ1P-5V-F  
JQ1P-6V-F  
JQ1P-9V-F  
JQ1P-12V-F  
JQ1P-18V-F  
JQ1P-24V-F  
JQ1P-48V-F  
9V DC  
12V DC  
18V DC  
24V DC  
48V DC  
Standard packing: Carton 100 pcs., Case 500 pcs.  
ds_61B03_en_jq: 201112D  
1
JQ  
RATING  
1. Coil data  
Drop-out  
voltage  
Nominal operating  
current  
Nominaloperating  
power  
(at 20C 68F)  
Contact  
arrangement  
Nominal coil  
voltage  
Pick-up voltage  
(at 20C 68F)  
Coil resistance  
[10%] (at 20C 68F)  
Max. applied voltage  
(at 20C 68F) [10%] (at 20C 68F)  
5V DC  
6V DC  
40.0mA  
33.3mA  
125  
180  
Standard type:  
75%V or less of  
nominal voltage (Initial) 5%V or more of  
nominal voltage  
High capacity type:  
80%V or less of  
nominal voltage (Initial)  
180% of nominal voltage  
(at 20C 68F)  
9V DC  
22.2mA  
16.7mA  
11.1mA  
8.3mA  
405  
1 Form A  
200mW  
130% of nominal voltage  
(at 70C 158F)  
[When using relays at  
85C 185F, see Notes*4]  
12V DC  
18V DC  
24V DC  
5V DC  
720  
(Initial)  
1,620  
2,880  
80 mA  
66.7mA  
44.4mA  
33.3mA  
22.2mA  
16.7mA  
8.3mA  
62.5  
90  
202.5  
Standard type:  
75%V or less of  
nominal voltage (Initial) 5%V or more of  
nominal voltage  
High capacity type:  
80%V or less of  
nominal voltage (Initial)  
150% of nominal voltage  
6V DC  
(at 20C 68F)  
9V DC  
1 Form C  
12V DC  
18V DC  
24V DC  
48V DC  
360  
810  
400mW  
110% of nominal voltage  
(at 70C 158F)  
[When using relays at  
85C 185F, see Notes*4]  
(Initial)  
1,440  
5,760  
2. Specifications  
Specifications  
Characteristics  
Item  
Standard type  
High capacity type  
Arrangement  
Contact resistance (Initial)  
Contact material  
1 Form A  
1 Form C  
1 Form A  
1 Form C  
Contact  
Max. 100m(By voltage drop 6 V DC 1 A)  
AgSnO2 type  
N.O. side:  
5 A 125 V AC,  
2 A 250 V AC,  
10 A 125 V AC,  
3 A 30 V AC  
5 A 250 V AC,  
N.C. side:  
2 A 125 V AC,  
1 A 250 V AC,  
1 A 30 V DC  
N.O. side:  
10 A 125 V AC,  
5 A 250 V AC,  
5 A 30 V AC  
N.C. side:  
3 A 125 V AC,  
2 A 250 V AC,  
1 A 30 V DC  
5 A 125 V AC,  
2 A 250 V AC,  
5 A 30 V DC  
Nominal switching capacity (resistive load)  
Max. switching power (resistive load)  
5 A 30 V DC  
N.O. side:  
N.O. side:  
1,250 VA, 150 W  
N.C. side:  
Rating  
625 VA, 90 W  
1,250 V AC, 150 W  
N.C. side:  
625 VA, 150 W  
250 VA, 30 W  
500 V AC, 30 W  
Max. switching voltage  
250 V AC, 110 V DC (0.3A)  
Max. switching current  
N.O.: 5 A, N.C.: 2 A  
200 mW 400 mW  
100 mA, 5 V DC  
Min. 1,000 M(at 500 V DC) Measurement at same location as “Breakdown voltage” section.  
1,000 Vrms for 1 min. 750 Vrms for 1 min. 1,000 Vrms for 1 min. 750 Vrms for 1 min.  
4,000 Vrms for 1 min. (Detection current: 10 mA)  
Max. 45C 113F Max. 45C 113F  
N.O.: 10 A, N.C.: 3 A  
Nominal operating power  
Min. switching capacity (reference value)*1  
200 mW 400 mW  
Insulation resistance (Initial)  
Between open contacts  
Between contact and coil  
Breakdown voltage  
(Initial)  
(By resistive method, nominal coil voltage  
applied to the coil; contact carrying current:  
5A, at 70C 158F)  
(By resistive method, nominal coil voltage  
applied to the coil; contact carrying current:  
10A, at 70C 158F)  
Temperature rise (coil)  
Electrical  
characteristics  
Surge breakdown voltage*2  
(Between contact and coil) (Initial)  
8,000 V  
Operate time (at nominal voltage) (at 20C 68F)  
(Initial)  
Max. 20 ms (excluding contact bounce time.)  
Release time (at nominal voltage) (at 20C 68F)  
(Initial)  
Max. 10 ms (excluding contact bounce time) (Without diode)  
Functional  
Shock resistance  
294 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)  
980 m/s2 (Half-wave pulse of sine wave: 6 ms.)  
10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10s.)  
10 to 55 Hz at double amplitude of 2.0 mm  
Min. 107  
Destructive  
Mechanical  
characteristics  
Functional  
Vibration resistance  
Destructive  
Expected life  
Conditions  
Unit weight  
Mechanical (at 180 times/min.)  
Conditions for operation, transport and storage*3  
Max. operating speed  
Ambient temperature: –40C to +70C –40F to +158F (class E insulation),  
–40C to +85C –40F to +185F*4 (class B insulation)  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
20 times/min. (at nominal switching capacity)  
Approx. 7 g .25 oz  
* Specifications will vary with foreign standards certification ratings.  
Notes:  
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.  
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981  
*3.The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport  
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.  
*4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with 20C  
68F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.  
ds_61B03_en_jq: 201112D  
2
JQ  
3. Expected electrical life  
Type  
Switching capacity  
No. of operations  
5 A 125 V AC  
3 A 125 V AC  
2 A 250 V AC  
5 A 30 V DC  
5104  
2105  
2105  
105  
5104  
2105  
2105  
105  
1 Form A  
1 Form C  
5 A 125 V AC  
3 A 125 V AC  
2 A 250 V AC  
3 A 30 V DC  
Standard type  
N.O.  
N.C.  
2 A 125 V AC  
1 A 250 V AC  
1 A 30 V DC  
2105  
2105  
105  
10 A 125 V AC  
5 A 250 V AC  
5 A 30 V DC  
5104  
5104  
105  
5104  
5104  
105  
2105  
2105  
105  
1 Form A  
1 Form C  
10 A 125 V AC  
5 A 250 V AC  
5 A 30 V DC  
High capacity type  
N.O.  
N.C.  
3 A 125 V AC  
2 A 250 V AC  
1 A 30 V DC  
REFERENCE DATA  
1.-(1) Max. switching capacity (1 Form A type)  
1.-(2) Max. switching capacity (1 Form C type)  
100  
100  
AC resistive load  
(High capacity type) N.O. side  
AC resistive load  
(Standard type) N.O. side  
AC resistive load (High capacity type)  
10  
5
10  
5
3
2
AC resistive load  
AC resistive load (Standard type)  
1
1
(High capacity type)  
N.C. side  
AC resistive load  
(Standard type)  
N.C. side  
10  
100 250  
1,000  
10  
100 250  
1,000  
Contact voltage, V  
Contact voltage, V  
Standard type  
2. Life curve  
Ambient temperature: room temperature  
3.-(1) Operate & release time (1 Form A type)  
Tested sample: JQ1a-12V-F, 25 pcs.  
3.-(2) Operate & release time (1 Form C type)  
Tested sample: JQ1-24V-F, 25 pcs.  
100  
8
8
125V AC  
resistive load  
6
6
Operate time  
Operate time  
10  
4
4
250V AC  
resistive load  
Max.  
Max.  
Max.  
Max.  
Min.  
Min.  
2
2
Min.  
Min.  
Release time  
Release time  
0
0
1
80  
100  
120  
150  
80  
100  
120  
150  
0
1
2
3
4
5
Coil applied voltage, %V  
Coil applied voltage, %V  
Contact current, A  
ds_61B03_en_jq: 201112D  
3
JQ  
4.-(1) Coil temperature rise (1 Form A type)  
4.-(2) Coil temperature rise (1 Form C type)  
Contact carrying current: 3 A, 5 A  
Measured portion: Inside the coil  
Contact carrying current: 3 A, 5 A  
Measured portion: Inside the coil  
50  
70  
60  
40  
5 A at 70°C  
5 A at 70°C  
50  
3 A at 70°C  
5 A at 85°C  
30  
40  
5 A at 85°C  
30  
20  
3 A at 70°C  
3 A at 85°C  
20  
3 A at 85°C  
10  
10  
0
0
100 110 120 130 140 150 160 170 180 190  
100 110 120 130 140 150 160  
Coil applied voltage, %V  
Coil applied voltage, %V  
5.-(1) Ambient temperature characteristics  
(1 Form A type)  
5.-(2) Ambient temperature characteristics  
(1 Form C type)  
Tested sample: JQ1a-24V-F  
Tested sample: JQ1-24V-F  
Contact carrying current: 3 A, 5 A  
Contact carrying current: 3 A, 5 A  
1 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 130C 266F) (Carrying current: 3 A)  
2 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 130C 266F) (Carrying current: 5 A)  
400  
400  
300  
300  
3 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 115C 239F) (Carrying current: 3 A)  
4 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 115C 239F) (Carrying current: 5 A)  
1
1
2
2
200  
200  
3
3
4
5
5
6
4
100  
100  
5 Pick-up voltage with a hot-start condition  
of 100%V on the coil (Carrying current: 5 A)  
6
7
7
6 Pick-up voltage with a hot-start condition  
of 100%V on the coil (Carrying current: 3 A)  
0
0
20 30 40 50 60 70 80 90  
20 30 40 50 60 70 80 90  
7 Pick-up voltage  
Ambient temperature, °C  
Ambient temperature, °C  
High capacity type  
1. Life curve  
Ambient temperature: room temperature  
2.-(1) Operate & release time (1 Form A type)  
Tested sample: JQ1aP-12V-F, 25 pcs.  
2.-(2) Operate & release time (1 Form C type)  
Tested sample: JQ1P-12V-F, 25 pcs.  
100  
8
6
8
6
4
2
0
Operate time  
125V AC resistive load  
Operate time  
10  
4
Max.  
Min.  
Max.  
Min.  
Max.  
Max.  
Min.  
Min.  
2
0
250V AC resistive load  
Release time  
120  
Release time  
120  
1
80  
100  
150  
80  
100  
150  
0
2
4
6
8
10  
Coil applied voltage, %V  
Coil applied voltage, %V  
Contact current, A  
3.-(1) Coil temperature rise (1 Form A type)  
3.-(2) Coil temperature rise (1 Form C type)  
Contact carrying current: 5 A, 10 A  
Measured portion: Inside the coil  
Contact carrying current: 5 A, 10 A  
Measured portion: Inside the coil  
70  
70  
10 A at 85°C  
60  
60  
10 A at 85°C  
10 A at 70°C  
50  
50  
10 A at 70°C  
5 A at 70°C  
40  
40  
5 A at 85°C  
30  
20  
10  
0
5 A at 70°C  
30  
5 A at 85°C  
20  
10  
0
100  
120  
140  
160  
180  
100 110 120 130 140 150 160  
Coil applied voltage, %V  
Coil applied voltage, %V  
ds_61B03_en_jq: 201112D  
4
JQ  
4.-(1) Ambient temperature characteristics  
(1 Form A type)  
4.-(2) Ambient temperature characteristics  
(1 Form C type)  
Tested sample: JQ1aP-24V-F  
Tested sample: JQ1P-24V-F  
Contact carrying current: 5 A, 10 A  
Contact carrying current: 5 A, 10 A  
1 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 130C 266F) (Carrying current: 5 A)  
2 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 130C 266F) (Carrying current: 10 A)  
400  
400  
300  
1
2
300  
1
2
3 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 115C 239F) (Carrying current: 5 A)  
4 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 115C 239F) (Carrying current: 10 A)  
200  
200  
100  
3
3
4
5
5
4
100  
5 Pick-up voltage with a hot-start condition  
of 100%V on the coil (Carrying current: 10 A)  
6
7
6
7
6 Pick-up voltage with a hot-start condition  
of 100%V on the coil (Carrying current: 5 A)  
0
0
20 30 40 50 60 70 80 90  
20 30 40 50 60 70 80 90  
7 Pick-up voltage  
Ambient temperature, °C  
Ambient temperature, °C  
DIMENSIONS (mm inch)  
Download CADData from our Web site.  
External dimensions  
Schematic (Bottom view)  
1 Form A  
1 Form A  
1 Form C  
CAD Data  
10  
20  
COM N.O.  
COM N.O.  
.394  
.787  
Coil  
Coil  
15.6  
.614  
N.C.  
0.4  
.016  
4.2  
.165  
7.62  
.300  
10.16  
.400  
0.3  
7.62  
.300  
7.62  
.300  
0.8  
0.5 dia.  
0.3  
.020 dia.  
.012  
.012  
.031  
PC board pattern (Bottom view)  
1FormC  
1 Form C  
1 Form A  
10  
20  
.787  
5-1.3 dia.  
4-1.3 dia.  
.394  
5-.051 dia.  
4-.051 dia.  
10.16  
.400  
7.62  
.300  
10.16  
.400  
7.62  
.300  
15.6  
.614  
7.62  
.300  
7.62  
.300  
0.4  
.016  
2.54  
.100  
4.2  
5.08  
.200  
2.54  
.100  
7.62  
.300  
10.16  
7.62  
.300  
.165  
.400  
0.3  
Tolerance: 0.1 .004  
0.5 dia.  
0.3  
0.8  
.020 dia.  
.012  
.012  
.031  
0.3  
.012  
Dimension:  
General tolerance  
Less than 1mm .039inch:  
0.2 .008  
Min. 1mm .039inch less than 5mm .197 inch: 0.3 .012  
Min. 5mm .197 inch: 0.4 .016  
ds_61B03_en_jq: 201112D  
5
JQ  
SAFETY STANDARDS  
UL/C-UL (Recognized)  
Item  
CSA (Certified)  
VDE (Certified)  
Contact rating  
TÜV (Certified)  
Rating  
SEMKO (Certified)  
File No. Contact rating File No. Contact rating File No.  
File No.  
File No. Contact rating  
5A 125V AC  
5A 277V AC  
5A 30V DC  
0.3A 110V DC  
1/10HP 125V  
AC  
5A 125V AC  
5A 277V AC  
5A 30V DC  
0.3A 110V DC  
1/10HP 125V  
AC  
5A 250V AC  
(cos=0.4)  
B 08 09 5A 250V AC  
Standard type  
(5A) 1 Form A  
E43028  
LR26550  
40011435  
817138  
817138  
817138  
817138  
3(2)A 125V AC  
2(1)A 250V AC  
5A 30V DC  
13461  
252  
(cos=0.4)  
5A 30V DC (0ms)  
1/6HP 277V AC  
1/6HP 277V AC  
5A 250V AC  
5A 125V AC  
5A 277V AC  
5A 30V DC  
0.3A 110V DC  
1/10HP 125V  
AC  
5A 125V AC  
5A 277V AC  
5A 30V DC  
0.3A 110V DC  
1/10HP 125V  
AC  
B 08 09 5A 250V AC  
Standard type  
(5A) 1 Form C  
E43028  
LR26550  
40011435 (cos=0.4)  
3(2)A 125V AC  
2(1)A 250V AC  
5A 30V DC  
13461  
252  
(cos=0.4)  
5A 30V DC (0ms)  
(N.O.)  
3A 250V AC  
(cos=0.4)  
(N.C.)  
1/6HP 277V AC  
1/6HP 277V AC  
High capacity  
type  
(10A) 1 Form A  
10A 250V AC  
(cos=0.4)  
B 08 09 10A 250V AC  
E43028 10A 125V AC LR26550 10A 125V AC 40011435  
5(3)A 250V AC  
5A 30V DC  
13461  
252  
(cos=0.4)  
5A 30V DC (0ms)  
8A 277V AC  
5A 30V DC  
0.3A 110V DC  
1/6HP 125V AC  
1/6HP 277V AC  
8A 277V AC  
5A 30V DC  
0.3A 110V DC  
1/6HP 125V AC  
1/6HP 277V AC  
(N.O.)  
High capacity  
type  
(10A) 1 Form C  
B 08 09 10A 250V AC  
E43028 10A 125V AC LR26550 10A 125V AC 40011435 10A 250V AC  
5(3)A 250V AC  
5A 30V DC  
13461  
252  
(cos=0.4)  
5A 30V DC (0ms)  
8A 277V AC  
5A 30V DC  
8A 277V AC  
5A 30V DC  
(cos=0.4)  
(N.C.)  
0.3A 110V DC  
1/6HP 125V AC  
1/6HP 277V AC  
0.3A 110V DC  
1/6HP 125V AC  
1/6HP 277V AC  
3A 250V AC  
(cos=0.4)  
NOTES  
Note about relay installation orientation  
When installing with the relay terminals parallel to the ground, the contact terminals at  
the bottom and the coil terminals at the top, component friction will occur after  
numerous switching actions or due to vibration in the non-excitation state.  
Since this may cause the relay to stop functioning when the pick-up voltage increases  
even if the nominal voltage is applied, please do not install using this orientation.  
Top  
Bottom  
For Cautions for Use, see Relay Technical Information.  
ds_61B03_en_jq: 201112D  
6

相关型号:

JQ1A-P-B-18V-F

Electromechanical Relay, SPST, Latched, 32.4VDC (Coil), 10A (Contact), 110VDC (Contact), Random, AC/DC Output
PANASONIC

JQ1A-P-B-6V-F

Electromechanical Relay, SPST, Latched, 10.8VDC (Coil), 10A (Contact), 110VDC (Contact), Random, AC/DC Output
PANASONIC

JQ1A-P-B-9V-F

Electromechanical Relay, SPST, Latched, 16.2VDC (Coil), 10A (Contact), 110VDC (Contact), Random, AC/DC Output
PANASONIC

JQ1A-XX

HIGH ELECTRICAL MECHANICAL NOISE IMMUNITY RELAY
NAIS

JQ1AAP-18V

HIGH ELECTRICAL MECHANICAL NOISE IMMUNITY RELAY
NAIS

JQ1AP-12V

HIGH ELECTRICAL MECHANICAL NOISE IMMUNITY RELAY
NAIS

JQ1AP-12V

Electromechanical Relay,
PANASONIC

JQ1AP-12V-F

1a/1c 5A/10A small power relays Class B coil insulation type also available.
PANASONIC

JQ1AP-18V

HIGH ELECTRICAL MECHANICAL NOISE IMMUNITY RELAY
NAIS

JQ1AP-18V

Electromechanical Relay,
PANASONIC

JQ1AP-18V-F

1a/1c 5A/10A small power relays Class B coil insulation type also available.
PANASONIC

JQ1AP-24V

HIGH ELECTRICAL MECHANICAL NOISE IMMUNITY RELAY
NAIS