1a/1c 5A/10A small power
relays
JQ RELAYS
FEATURES
TYPICAL APPLICATIONS
• High electrical noise immunity
• High switching capacity in a compact
package
• Air conditioners
• Refrigerators
• Microwave ovens
• Heaters
• High sensitivity: 200 mW (1a),
400 mW (1c)
• High surge voltage: 8,000 V between
contacts and coil
• UL, CSA, VDE, SEMKO approved and
TÜV available
• Class B coil insulation type also
available.
RoHS compliant
ORDERING INFORMATION
JQ
F
Contact arrangement
1a: 1 Form A
1 : 1 Form C
Contact capacity
Nil: Standard (5A)
P: High capacity (10A)
Coil insulation class
Nil: Class E coil insulation
B: Class B coil insulation (UL)
Nominal coil voltage (DC)
5V, 6V, 9V, 12V, 18V, 24V, 48V*
Contact material
F: AgSnO2 type
Certified by UL, CSA, VDE and SEMKO
Note: *Available only for 1 Form C type
TYPES
1) Standard type
Standard type
1 Form C
High capacity type
Nominal coil voltage
1 Form A
Part No.
1 Form A
Part No.
1 Form C
Part No.
Part No.
JQ1-5V-F
JQ1-6V-F
JQ1-9V-F
JQ1-12V-F
JQ1-18V-F
JQ1-24V-F
JQ1-48V-F
5V DC
6V DC
JQ1a-5V-F
JQ1a-6V-F
JQ1a-9V-F
JQ1a-12V-F
JQ1a-18V-F
JQ1a-24V-F
–
JQ1aP-5V-F
JQ1aP-6V-F
JQ1aP-9V-F
JQ1aP-12V-F
JQ1aP-18V-F
JQ1aP-24V-F
–
JQ1P-5V-F
JQ1P-6V-F
JQ1P-9V-F
JQ1P-12V-F
JQ1P-18V-F
JQ1P-24V-F
JQ1P-48V-F
9V DC
12V DC
18V DC
24V DC
48V DC
Standard packing: Carton 100 pcs., Case 500 pcs.
ASCTB185E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
JQ
RATING
1. Coil data
Drop-out
voltage
Nominal operating
current
Nominaloperating
power
(at 20°C 68°F)
Contact
arrangement
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Coil resistance
[ 10%] (at 20°C 68°F)
Max. applied voltage
(at 20°C 68°F) [ 10%] (at 20°C 68°F)
5V DC
6V DC
40.0mA
33.3mA
125
180
Ω
Ω
Ω
Ω
Ω
Ω
Standard type:
75%V or less of
nominal voltage (Initial) 5%V or more of
nominal voltage
High capacity type:
80%V or less of
nominal voltage (Initial)
180% of nominal voltage
(at 20°C 68°F)
9V DC
22.2mA
16.7mA
11.1mA
8.3mA
405
1 Form A
200mW
400mW
130% of nominal voltage
(at 70°C 158°F)
[When using relays at
85°C 185°F, see Notes*4]
12V DC
18V DC
24V DC
5V DC
720
(Initial)
1,620
2,880
80 mA
66.7mA
44.4mA
33.3mA
22.2mA
16.7mA
8.3mA
62.5Ω
90
202.5Ω
360
810
Standard type:
75%V or less of
nominal voltage (Initial) 5%V or more of
nominal voltage
High capacity type:
80%V or less of
nominal voltage (Initial)
150% of nominal voltage
6V DC
Ω
(at 20°C 68°F)
9V DC
1 Form C
12V DC
18V DC
24V DC
48V DC
Ω
Ω
Ω
Ω
110% of nominal voltage
(at 70°C 158°F)
[When using relays at
85°C 185°F, see Notes*4]
(Initial)
1,440
5,760
2. Specifications
Specifications
Characteristics
Item
Standard type
High capacity type
Arrangement
Contact resistance (Initial)
Contact material
1 Form A
1 Form C
1 Form A
1 Form C
Contact
Max. 100mΩ (By voltage drop 6 V DC 1 A)
AgSnO2 type
N.O. side:
5 A 125 V AC,
2 A 250 V AC,
10 A 125 V AC,
3 A 30 V AC
5 A 250 V AC,
N.C. side:
2 A 125 V AC,
1 A 250 V AC,
1 A 30 V DC
N.O. side:
10 A 125 V AC,
5 A 250 V AC,
5 A 30 V AC
N.C. side:
3 A 125 V AC,
2 A 250 V AC,
1 A 30 V DC
5 A 125 V AC,
2 A 250 V AC,
5 A 30 V DC
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
5 A 30 V DC
Rating
N.O. side:
N.O. side:
1,250 VA, 150 W
N.C. side:
625 VA, 90 W
1,250 V AC, 150 W
N.C. side:
625 VA, 150 W
250 VA, 30 W
500 V AC, 30 W
Max. switching voltage
250 V AC, 110 V DC (0.3A)
Max. switching current
N.O.: 5 A, N.C.: 2 A
200 mW 400 mW
N.O.: 10 A, N.C.: 3 A
200 mW 400 mW
Nominal operating power
Min. switching capacity (reference value)*1
100 mA, 5 V DC
Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1 min. 750 Vrms for 1 min. 1,000 Vrms for 1 min. 750 Vrms for 1 min.
4,000 Vrms for 1 min. (Detection current: 10 mA)
Max. 45°C 113°F Max. 45°C 113°F
Insulation resistance (Initial)
Between open contacts
Between contact and coil
Breakdown voltage
(Initial)
(By resistive method, nominal coil voltage
applied to the coil; contact carrying current:
5A, at 70°C 158°F)
(By resistive method, nominal coil voltage
applied to the coil; contact carrying current:
10A, at 70°C 158°F)
Temperature rise (coil)
Electrical
characteristics
Surge breakdown voltage*2
(Between contact and coil) (Initial)
8,000 V
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 20 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 10 ms (excluding contact bounce time) (Without diode)
Functional
Shock resistance
294 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 107
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Expected life
Conditions
Unit weight
Mechanical (at 180 times/min.)
Conditions for operation, transport and storage*3
Max. operating speed
Ambient temperature: –40°C to +70°C –40°F to +158°F (class E insulation),
–40°C to +85°C –40°F to +185°F*4 (class B insulation)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)
Approx. 7 g .25 oz
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with
20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
ASCTB185E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
JQ
3. Expected electrical life
Type
Switching capacity
No. of operations
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
5 A 30 V DC
5×104
2×105
2×105
105
5×104
2×105
2×105
105
1 Form A
1 Form C
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
3 A 30 V DC
Standard type
N.O.
N.C.
2 A 125 V AC
1 A 250 V AC
1 A 30 V DC
2×105
2×105
105
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5×104
5×104
105
5×104
5×104
105
2×105
2×105
105
1 Form A
1 Form C
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
High capacity type
N.O.
N.C.
3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
REFERENCE DATA
1.-(1) Max. switching capacity (1 Form A type)
1.-(2) Max. switching capacity (1 Form C type)
100
100
AC resistive load
(High capacity type) N.O. side
AC resistive load
(Standard type) N.O. side
AC resistive load (High capacity type)
10
5
10
5
3
2
AC resistive load
AC resistive load (Standard type)
1
1
(High capacity type)
N.C. side
AC resistive load
(Standard type)
N.C. side
10
100 250
1,000
10
100 250
1,000
Contact voltage, V
Contact voltage, V
Standard type
2. Life curve
Ambient temperature: room temperature
3.-(1) Operate & release time (1 Form A type)
Tested sample: JQ1a-12V-F, 25 pcs.
3.-(2) Operate & release time (1 Form C type)
Tested sample: JQ1-24V-F, 25 pcs.
100
8
8
125V AC
resistive load
6
6
Operate time
Operate time
10
4
4
250V AC
resistive load
Max.
Max.
Max.
Max.
Min.
Min.
Min.
2
2
Min.
Release time
Release time
1
0
0
0
1
2
3
4
5
80
100
120
150
80
100
120
150
Contact current, A
Coil applied voltage, %V
Coil applied voltage, %V
ASCTB185E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
JQ
4.-(1) Coil temperature rise (1 Form A type)
4.-(2) Coil temperature rise (1 Form C type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
50
70
60
40
5 A at 70°C
5 A at 70°C
50
3 A at 70°C
5 A at 85°C
30
40
5 A at 85°C
30
20
3 A at 70°C
3 A at 85°C
20
3 A at 85°C
10
10
0
0
100 110 120 130 140 150 160 170 180 190
100 110 120 130 140 150 160
Coil applied voltage, %V
Coil applied voltage, %V
5.-(1) Ambient temperature characteristics
(1 Form A type)
5.-(2) Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1a-24V-F
Tested sample: JQ1-24V-F
Contact carrying current: 3 A, 5 A
Contact carrying current: 3 A, 5 A
1 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 3 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
400
400
300
300
1
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 3 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
1
2
2
200
200
3
3
4
5
5
6
4
100
100
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
6
7
7
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 3 A)
0
0
20 30 40 50 60 70 80 90
20 30 40 50 60 70 80 90
7 Pick-up voltage
Ambient temperature, °C
Ambient temperature, °C
High capacity type
1. Life curve
Ambient temperature: room temperature
2.-(1) Operate & release time (1 Form A type)
Tested sample: JQ1aP-12V-F, 25 pcs.
2.-(2) Operate & release time (1 Form C type)
Tested sample: JQ1P-12V-F, 25 pcs.
100
8
6
8
6
4
2
0
Operate time
125V AC resistive load
10
Operate time
4
Max.
Min.
Max.
Min.
Max.
Max.
250V AC resistive load
Min.
Min.
2
0
Release time
120
Release time
120
1
80
100
150
0
2
4
6
8
10
80
100
150
Contact current, A
Coil applied voltage, %V
Coil applied voltage, %V
3.-(1) Coil temperature rise (1 Form A type)
3.-(2) Coil temperature rise (1 Form C type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
70
70
10 A at 85°C
60
60
10 A at 85°C
10 A at 70°C
50
50
10 A at 70°C
5 A at 70°C
40
40
5 A at 85°C
30
20
10
0
5 A at 70°C
30
5 A at 85°C
20
10
0
100
120
140
160
180
100 110 120 130 140 150 160
Coil applied voltage, %V
Coil applied voltage, %V
ASCTB185E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
JQ
4.-(1) Ambient temperature characteristics
4.-(2) Ambient temperature characteristics
(1 Form C type)
(1 Form A type)
Tested sample: JQ1aP-24V-F
Tested sample: JQ1P-24V-F
Contact carrying current: 5 A, 10 A
Contact carrying current: 5 A, 10 A
1 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 10 A)
400
400
300
1
2
300
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 10 A)
1
2
200
200
100
3
3
4
5
4
5
100
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 10 A)
6
7
6
7
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
0
20 30 40 50 60 70 80 90
0
20 30 40 50 60 70 80 90
7 Pick-up voltage
Ambient temperature, °C
Ambient temperature, °C
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
DIMENSIONS (mm inch)
External dimensions
Schematic (Bottom view)
1 Form C
CAD Data
1 Form A
1 Form A
10
20
COM N.O.
COM N.O.
.394
.787
Coil
Coil
15.6
.614
N.C.
0.4
.016
4.2
.165
7.62
.300
10.16
.400
0.3
7.62
.300
7.62
.300
0.8
0.5 dia.
0.3
.020 dia.
.012
.012
.031
PC board pattern (Bottom view)
1FormC
1 Form C
1 Form A
10
20
.787
4-1.3 dia.
5-1.3 dia.
.394
4-.051 dia.
5-.051 dia.
10.16
.400
7.62
.300
10.16
.400
7.62
.300
15.6
.614
7.62
.300
7.62
.300
0.4
.016
2.54
.100
4.2
5.08
.200
2.54
.100
7.62
.300
10.16
7.62
.300
.165
.400
0.3
Tolerance: 0.1 .004
0.5 dia.
0.3
0.8
.031
.020 dia.
.012
.012
0.3
.012
Dimension:
Less than 1mm .039inch:
General tolerance
0.2 .008
Min. 1mm .039inch less than 5mm .197 inch: 0.3 .012
Min. 5mm .197 inch: 0.4 .016
ASCTB185E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
JQ
SAFETY STANDARDS
UL/C-UL (Recognized)
Item
CSA (Certified)
File No. Contact rating
VDE (Certified)
Contact rating
TÜV (Certified)
Rating
5A 250V AC (cosφ=0.4)
13461 296 5A 30V DC (0ms)
SEMKO (Certified)
File No. Contact rating
File No.
Contact rating
File No.
File No.
B 11 04
Standard type
(5A) 1 Form A
E43028
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC
LR26550
LR26550
LR26550
LR26550
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC
40011435 5A 250V AC (cosφ=0.4)
817138
3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
Standard type
(5A) 1 Form C
E43028
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC
40011435 5A 250V AC (cosφ=0.4)
(N.O.)
B 11 04 5A 250V AC (cosφ=0.4)
13461 296 5A 30V DC (0ms)
817138
3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
3A 250V AC (cosφ=0.4)
(N.C.)
High capacity type E43028
(10A) 1 Form A
10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
40011435 10A 250V AC (cosφ=0.4) B 11 04
10A 250V AC (cosφ=0.4) 817138
13461 296 5A 30V DC (0ms)
5(3)A 250V AC
5A 30V DC
High capacity type E43028
(10A) 1 Form C
10A 125V AC
8A 277V AC
5A 30V DC
10A 125V AC
8A 277V AC
5A 30V DC
40011435 (N.O.)
B 11 04
10A 250V AC (cosφ=0.4) 817138
5(3)A 250V AC
5A 30V DC
10A 250V AC (cosφ=0.4) 13461 296 5A 30V DC (0ms)
(N.C.)
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
3A 250V AC (cosφ=0.4)
NOTES
Note about relay installation orientation
When installing with the relay terminals parallel to the ground, the contact terminals at
the bottom and the coil terminals at the top, component friction will occur after
numerous switching actions or due to vibration in the non-excitation state.
Since this may cause the relay to stop functioning when the pick-up voltage increases
even if the nominal voltage is applied, please do not install using this orientation.
Top
Bottom
For Cautions for Use.
ASCTB185E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panasonic:
JQ1-12V JQ1P-24V JQ1AP-B-12V JQ1P-B-24V-F JQ1P-48V-F JQ1AP-B-24V-F JQ1-B-12V-F JQ1APE-24V-H12
JQ1-5V JQ1A-5V JQ1A-12V JQ1-24V JQ1A-24V JQ1P-5V JQ1AP-12V JQ1P-12V JQ1AP-24V JQ1A-5V-F
JQ1AP-12V-F JQ1AP-24V-F JQ1AP-5V-F JQ1-5V-F JQ1A-12V-F JQ1P-5V-F JQ1-24V-F JQ1-12V-F JQ1P-12V-F
JQ1P-24V-F JQ1A-24V-F JQ1AP-5V JQ1-18V JQ1-18V-F JQ1-3V JQ1-48V JQ1-48V-F JQ1-6V JQ1-6V-F
JQ1-9V JQ1-9V-F JQ1A-18V JQ1A-18V-F JQ1A-3V JQ1A-6V JQ1A-6V-F JQ1A-9V JQ1A-9V-F JQ1A-B-12V
JQ1A-B-12V-F JQ1A-B-18V JQ1A-B-18V-F JQ1A-B-24V JQ1A-B-24V-F JQ1A-B-5V JQ1A-B-5V-F JQ1A-B-6V
JQ1A-B-6V-F JQ1A-B-9V JQ1A-B-9V-F JQ1A-F-24V JQ1AP-18V JQ1AP-18V-F JQ1AP-3V JQ1AP-6V JQ1AP-6V-
F JQ1AP-9V JQ1AP-9V-F JQ1AP-B-12V-F JQ1AP-B-12V-Y3 JQ1AP-B-18V JQ1AP-B-18V-F JQ1AP-B-24V
JQ1AP-B-24V-Y3 JQ1AP-B-5V JQ1AP-B-5V-F JQ1AP-B-6V JQ1AP-B-6V-F JQ1AP-B-9V JQ1AP-B-9V-F JQ1AP-
B-9V-Y3 JQ1AP-F-12V JQ1AP-F-12V-F JQ1APF-18V JQ1AP-F-24V-F JQ1APF-B-12V-F JQ1APF-F-12V JQ1APF-
F-12V-F JQ1APF-F-24V-F JQ1APF-F-5V-F JQ1APF-F-9V-F JQ1-B-12V JQ1-B-18V JQ1-B-18V-F JQ1-B-24V
JQ1-B-24V-F JQ1-B-48V JQ1-B-48V-F JQ1-B-5V JQ1-B-5V-F JQ1-B-6V JQ1-B-6V-F
相关型号:
JQ1P-24V
Power/Signal Relay, 1 Form C, SPDT, Momentary, 0.017A (Coil), 24VDC (Coil), 400mW (Coil), 3A (Contact), 110VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount,
PANASONIC
©2020 ICPDF网 联系我们和版权申明