LKS1AF-6V [PANASONIC]
Power/Signal Relay, SPST, Momentary, 0.042A (Coil), 6VDC (Coil), 250mW (Coil), DC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT;型号: | LKS1AF-6V |
厂家: | PANASONIC |
描述: | Power/Signal Relay, SPST, Momentary, 0.042A (Coil), 6VDC (Coil), 250mW (Coil), DC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT 继电器 |
文件: | 总3页 (文件大小:74K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
VDE
250 mW
SLIM POWER RELAY
LK-S RELAYS
FEATURES
11.0
.433
24.0
.945
1. High sensitivity: 250mW
The power-saving relay is highly sensitive
at the nominal operating power of 250
mW (530 mW power consumption on LK
relays).
3. High noise immunity realized by the
card separation structure between
contact and coil
25.0
.984
4. Popular terminal pitch in AV
equipment field
2. High insulation resistance between
contact and coil
5. Space-saving slim type
Base area: Width 11 × Length 24 mm
mm inch
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
2) Surge withstand voltage between
contact and coil: 10,000 V or more
Width .433 × Length .945 inch
6. Conforms to the various safety
standards
UL/CSA, VDE, TÜV and SEMKO SEV
Compliance with RoHS Directive
approved
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form A
Max. operating speed
20 cpm (at rated load)
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Initial insulation resistance*1
Min. 1,000 MΩ (at 500 V DC)
Max. 100 mΩ
Between open
contacts
Initial *2
breakdown
voltage
1,000 Vrms for 1 min.
Contact material
AgSnO2 type
5 A 277 V AC
1,385 V A
277 V AC
Nominal switching capacity
Max. switching power
Between contact and
coil
4,000 Vrms for 1 min.
Rating
(resistive load)
Initial surge voltage between contact
and coil*3
Operate time*4 (at nominal voltage)
Release time (without diode)*4
(at nominal voltage)
Max. switching voltage
Min. 10,000 V
Max. switching current
Min. switching capacity#1
5 A (AC)
Max. 15 ms (at 20°C 68°F)
Max. 5 ms (at 20°C 68°F)
100 mA, 5 V DC
106
Mechanical (at 180 cpm)
Expected life
Electrical (at 20 cpm)
(min. operations)
105
Max. 35°C with nominal coil
voltage and at 5 A contact
carrying current
(resistance method)
Min. 200 m/s2{approx. 20 G}
(at rated load)
Temperature rise (at 70°C)
Coil
Nominal operating power
250 mW
Functional*5
Destructive*6 Min. 1,000 m/s2{approx. 100 G}
Shock resistance
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
10 to 55Hz
Functional*7
at double amplitude of 1.5mm
Remarks
Vibration resistance
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as “Initial breakdown voltage” section.
*2 Detection current: 10mA
10 to 55Hz
Destructive
at double amplitude of 1.5mm
*3 Wave is standard shock voltage of 1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time.
Ambient
temp.
–40°C to +70°C
–40°F to +158°F
5 to 85% R.H.
Conditions for operation,
transport and storage*8
(Not freezing and
*5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
*6 Half-wave pulse of sine wave: 6 ms
Humidity
condensing at low
temperature)
*7 Detection time: 10 µs
Air
pressure
86 to 106 kPa
*8 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
Unit weight
Approx. 12 g .42 oz
TYPICAL APPLICATIONS ORDERING INFORMATION
• Audio visual equipment
• Office equipment
• Home appliances
Ex. LKS 1a
F
–
12V
Contact arrangement
1a: 1 Form A
Protective construction
F: Flux-resistant type
Coil voltage(DC)
5, 6, 9, 12, 18, 24V
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard.
Notes 1. Standard packing Carton: 100 pcs. Case: 500 pcs.
2. 6 V, 18 V DC types are also available. Please consult us for details.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
LK-S
TYPES AND COIL DATA (at 20°C 68°F)
Pick-up
voltage,
Drop-out
voltage,
Nominal
operating
current,
Maximum
allowable
voltage,
Nominal
voltage,
V DC
Nominal
operatingpower,
mW
Coil resistance,
Part No.
V DC (max.)
(Initial)
V DC (min.)
(Initial)
Ω ( 10%)
mA ( 10%)
V DC (at 20°C 68°F)
LKS1aF-5V
LKS1aF-6V
LKS1aF-9V
LKS1aF-12V
LKS1aF-18V
LKS1aF-24V
5
6
3.5
4.2
0.5
0.6
0.9
1.2
1.8
2.4
100
144
50
250
250
250
250
250
250
6.5
7.8
41.7
27.8
20.8
13.9
10.4
9
6.3
324
11.7
15.6
23.4
31.2
12
18
24
8.4
576
12.6
16.8
1,296
2,304
mm inch
DIMENSIONS
PC board pattern (Bottom view)
2-0.9 dia
2-.035 dia
2-1.3 dia
2-.051 dia
16.5
.650
Max. 25.0
.984
7.5
.295
0.5
.020
20.0
.787
4
.157
Tolerance: 0.1 .004
Schematic (Bottom view)
0.5 dia.
.020 dia.
0.3
.012
0.4
.016
1.65
.065
Max. 24.0
.945
Max. 11.0
.433
16.5
.650
1.0
.039
Dimension:
Max. 1mm .039 inch:
General tolerance
0.1 .004
7.5
.295
1 to 3mm .039 to .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
20.0
.787
REFERENCE DATA
1. Max. switching power (AC resistive load)
2. Coil temperature rise
3.Ambient temperature characteristics and coil
applied voltage
Contact current: 5 A
Sample: LKS1aF-12V, 6 pcs.
Point measured: coil inside
Contact current: 0 A, 5A
30
25
20
15
10
5
100
500
20°C 5A
20°C 0A
400
70°C 5A
70°C 0A
Allowable ambient temperatures
against % coil voltages
(max. inside the coil tem-
10
5
300
perature set as
115°C 239°F)
200
1
Cold start
100
Pick-up voltage
0
0
0
80
100
120
0
10
100
0
10 20 30 40 50 60 70 80
Contact voltage, V
Coil applied voltage, %V
Ambient temperature, °C
4. Life curve
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: Room temperature
100
250V AC resistive load
10
1
0
1
2
3
4
5
Contact current, A
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
LK-S
5-(1). Electrical life test
Change of pick-up and drop-out voltage
Change of contact resistance
(5 A 277 V AC, resistive load)
12
50
45
40
35
30
25
20
15
10
5
Sample: LKS1aF-12V, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
10
Pick-up voltage
Ambient temperature: 20°C 68°F
Max.
8
6
x
Circuit:
Min.
Max.
x
Contact
welding
detection
and Mis-
contacting
detection
circuit
Min.
4
Drop-out voltage
277V AC
12V DC
Max.
x
Min.
2
0
0
0
5
10
0
5
10
No. of operations, ×104
No. of operations, ×104
5-(2). Electrical life test
(UL lamp load test TV-5)
Tested sample: LKS1aF-12V, 6 pcs.
• Overload test
Load: 7.5 A 120 V AC (60 Hz),
Inrush: 111 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 50 ope.
• Endurance test
Load: 5A 120 V AC (60 Hz),
Inrush: 78 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 25,000 ope.
Change of pick-up and drop-out voltage
Change of contact resistance
12
50
45
40
35
30
25
20
15
10
5
10
Pick-up voltage
8
Max.
x
Min.
6
4
Max.
x
Drop-out voltage
Max.
x
2
0
Min.
Min.
2.5
0
0
0
2.5
No. of operations, ×104
No. of operations, ×104
For Cautions for Use, see Relay Technical Information .
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
相关型号:
©2020 ICPDF网 联系我们和版权申明