NPS-C7W [PANASONIC]
ON/OFF Input Sensor Controller;型号: | NPS-C7W |
厂家: | PANASONIC |
描述: | ON/OFF Input Sensor Controller |
文件: | 总6页 (文件大小:362K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ON/OFF Input Sensor Controller
961
NPS SERIES
FIBER
SENSORS
Related Information ■General terms and conditions............. F-3
■General precautions ..................... P.1595
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
panasonic.net/id/pidsx/global
STATIC
CONTROL
DEVICES
LASER
MARKERS
Multi-functional DIN rail mounting slim sensor controller
PLC
HUMAN MACHINE
INTERFACES
NPS-CT7
DIN rail mounting
Edge trigger
ENERGY
MANAGEMENT
SOLUTIONS
Mountable on 35 mm 1.378 in DIN rail by one-push.
It reduces mounting space and mounting operations.
Synchronized input is possible at either the rising or
the falling edge of the external synchronization signal.
With this, now only one controller suffices where earlier
two were required in applications, such as, detecting
presence of bottle caps.
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Example: Detecting presence of cap on bottle
35 mm 1.378 in
width DIN rail
• Conventional method
• Using NPS-CT7
Sensor for sensing
Sensor signal input
Sensor Mounting
Stand
NPS-C7, NPS-CT7
Two outputs: contact and non-contact
Output
Sensor
Checker
Controller
External
synchronization
input
Output
NPS-CT7
Sensor
Useful for various applications because the controller
has two outputs, relay contact and NPN open-collector
transistor output.
Controller
Controller
with timer
External
Other Products
synchronization
input
Synchronizing
sensor
NPS
NPS-C7W
No cap Cap present
Connects two sensors
Sensor signal
input
Effective (condition for making output ON)
Ineffective
Two sensors can be connected, and two independent
outputs are generated.
Effective
External
synchronization
input
Ineffective (condition for disabling output)
5 μs approx.
ON
Output
OFF
ON/OFF Input Sensor Controller NPS SERIES
962
ORDER GUIDE
FIBER
SENSORS
LASER
SENSORS
Supply
voltage
Power supply
for sensor
External synchronization
function
Type
Appearance
Model No.
Output
Timer function
PHOTO-
ELECTRIC
SENSORS
MICRO
12 V DC±10 %
150 mA max.
PHOTO-
ELECTRIC
SENSORS
Gate trigger
NPS-C7
• Relay contact 1c
• NPN open-collector
transistor
AREA
SENSORS
12 V DC±10 %
130 mA max.
Gate trigger and edge
trigger
Three function
selectable timer
100-240 V AC
±10 %
NPS-CT7
NPS-C7W
SAFETY LIGHT
CURTAINS
SAFETY
/
COMPONENTS
PRESSURE /
FLOW
12 V DC±10 %
120 mA max.
Relay contact
1c ×2
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Accessory
PARTICULAR
USE
SENSORS
・ NPS-CV (Protection cover)
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
SPECIFICATIONS
MEASURE-
MENT
SENSORS
DIN rail mounting
High-performance
NPS-CT7
STATIC
Type
CONTROL
DEVICES
General use
NPS-C7
Two sensor connection
NPS-C7W
Item
Model No.
LASER
MARKERS
Applicable sensors
Supply voltage
Power consumption
Photoelectric sensor, inductive proximity sensor, etc., with NPN transistor output or relay output
100
-240 V AC ±10 %
PLC
6 VA or less
HUMAN
MACHINE
INTERFACES
Voltage
Current
12 V DC ±10 % (incorporated with short-circuit protection)
130 mA max.
Power supply
for sensor
150 mA max.
Relay contact 1c
• Switching capacity:
250 V 3 A AC (resistive load) • Applied voltage: 30 V DC or less
120 mA max.
Relay contact 1c ×2
• Maximum sink current: 100 mA or less • Switching capacity:
250 V 3 A AC (resistive load)
• Electrical life:
ENERGY
MANAGEMENT
SOLUTIONS
NPN open-collector transistor
FA
COMPONENTS
• Electrical life:
(between output and 0 V)
• Residual voltage:
Output
100,000 switching operations or more
(rated load)(at 1,800 operations/hour)
• Mechanical life:
100,000 switching operations or more
(rated load)(at 1,800 operations/hour)
• Mechanical life:
MACHINE
VISION
1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
SYSTEMS
UV
10 million switching operations or more
(at 36,000 operations/hour)
10 million switching operations or more
(at 36,000 operations/hour)
CURING
SYSTEMS
Output operation
Response time
Switchable normal operation or inverse operation
Relay contact: 10 ms approx., NPN open-collector transistor: 5 µs or less
Red LED (lights up when the power is ON)
10 ms approx.
Power
Output (Note 2)
Red LED (lights up when the output is ON)
Sensor
Mounting
Stand
Red LED
lights up when the sensor signal
input is effective
Sensor
Checker
Sensor signal input
Sensor
Controller
Other
Products
Red LED
External
synchronization input
lights up when the external
synchronization input is effective
NPS
External synchronization function
Timer function
Gate trigger
Gate trigger and edge trigger
Three function selectable timer
Timer period: switchable either
40 ms to 1 sec. or 0.4 sec. to 10 sec.
Ambient temperature
Ambient humidity
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Material
-10 to +50 °C +14 to +122 °F (No dew condensation or icing allowed), Storage:-30 to +70 °C -22 to +158 °F
35 to 85 % RH, Storage: 35 to 85 % RH
1,500 V AC for one min. between the power and the output terminals
10 MΩ, or more, with 500 V DC megger between the power and the output terminals
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions two times each
Enclosure: ABS, Terminal block: PBT (Glass fiber reinforced)
Connecting method
Weight
Terminal block
Net weight: 160 g approx.
Accessories
Short bar: 1 pc., NPS-CV (Protection cover): 1 pc., Short-circuit protection plate: 1 pc., Adjusting screwdriver: 1 pc. (NPS-CT7 only)
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) In NPS-C7W, two output indicators, Sensor 1 output indicator and Sensor 2 output indicator, have been incorporated.
ON/OFF Input Sensor Controller NPS SERIES
963
FIBER
I/O CIRCUIT AND WIRING DIAGRAMS
SENSORS
LASER
SENSORS
NPS-C7 NPS-CT7
I/O circuit diagram
PHOTO-
ELECTRIC
SENSORS
Terminal arrangement diagram
13
14
15
IN
11
16
MICRO
PHOTO-
Terminal No.
OC
OUT
ELECTRIC
SENSORS
0
+12
①
⑤
Power
supply
circuit
AREA
100-240 V AC
±10 %
9
10
12
~
SENSORS
0
+12 ES
SAFETY LIGHT
CURTAINS
/
SAFETY
COMPONENTS
*1
NPS-
②
③
COM.
NO
PRESSURE /
FLOW
Non-voltage contact or
NPN transistor output
Relay contact 1c
Not connected
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
④ NC
AC
+12 V
5
6
7
8
⑥
⑦
⑧
PARTICULAR
USE
AC COM. NO NC
SENSORS
or
1
2
3
4
SENSOR
OPTIONS
High: 4 to 12 V, or open
Low: 0 to 1.5 V
0 V
Relay contact output
⑨
~
SIMPLE
WIRE-SAVING
UNITS
100-240 V AC
±10 %
12 V
⑩
*1
5.1 kΩ
ES
WIRE-SAVING
SYSTEMS
⑪
Note: Response time of the NPN open-collector transistor output of NPS-C7
and NPS-CT7 is 5 μs. If a relay or a micro-switch (mechanical contact)
is connected, its bounce may result in output chattering. Take care of
this aspect, especially when the timer function is used.
100 Ω
⑫ Not connected
MEASURE-
MENT
12 V
⑭
SENSORS
*1
5.1 kΩ
100 Ω
IN
STATIC
CONTROL
DEVICES
⑮
⑯
⑬
OC (open-collector) output
0 V
LASER
MARKERS
PLC
Internal circuit
Users’ circuit
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
NPS-C7W
I/O circuit diagram
Terminal arrangement diagram
FA
COMPONENTS
13
14
+12 IN 1
10 11
15
16
12
Terminal No.
MACHINE
VISION
0
①
⑤
Power
supply
circuit
SYSTEMS
100-240 V AC
±10 %
~
9
UV
CURING
SYSTEMS
0
+12 IN 2
②
③
COM. 1
NPS-C7W
Relay contact 1c
NO 1
④ NC 1
Sensor
Mounting
Stand
AC COM. 2 NO 2 NC 2
Sensor
Checker
5
6
7
8
⑥
COM. 2
Sensor
⑦ NO 2
Relay contact 1c
AC COM. 1 NO 1 NC 1
Controller
NC 2
⑧
Other
Products
1
2
3
4
*1
0 V
⑨
Relay contact output
~
Non-voltage contact or
NPN transistor output
100-240 V AC
±10 %
NPS
12 V
IN 2
⑩
*1
5.1 kΩ
+12 V
⑪
100 Ω
⑫ Not connected
0 V
⑬
or
12 V
⑭
*1
5.1 kΩ
100 Ω
IN 1
High: 4 to 12 V, or open
Low: 0 to 1.5 V
⑮
⑯ Not connected
Internal circuit
Users’ circuit
ON/OFF Input Sensor Controller NPS SERIES
964
PRECAUTIONS FOR PROPER USE
FIBER
Refer to p.1595 for general precautions.
SENSORS
LASER
SENSORS
• Never use this product in a device for personnel protection.
• In case of using devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC
etc., for personnel protection applicable in each region or country.
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
Functional description
⑮
⑮
⑮
AREA
NPS-C7
NPS-CT7
NPS-C7W
SENSORS
SAFETY LIGHT
CURTAINS
SAFETY
/
③
⑥ ⑦
⑤
COMPONENTS
⑧ ②
⑤ ⑩ ⑪
⑭ ⑬ ⑫
PRESSURE /
FLOW
②
①
SENSORS
④
①
⑨
①
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
⑮
⑮
⑮
SIMPLE
WIRE-SAVING
UNITS
Description
Function
Description
Function
Power indicator
(Red LED)
Output indicator
(Red LED)
Sensor 1 output
indicator (Red LED)
Sensor 2 output
indicator (Red LED)
WIRE-SAVING
SYSTEMS
Selects the operation of external synchronization.
①
②
③
④
Lights up when the power is ON.
INV.
NORM.
External
MEASURE-
MENT
synchronization
operation mode
switch
INV.: The output is neglected when the external
synchronization input is High.
NORM.: The output is neglected when the external
synchronization input is Low.
⑩
⑪
SENSORS
Lights up when the output is ON.
Selects the output operation.
STATIC
CONTROL
DEVICES
Selects Gate trigger or Edge trigger.
LASER
Gate/Edge
trigger operation
mode switch
MARKERS
Sensor signal
input selection
switch
: Effective at the instant the external
synchronization input is applied.
: Effective over the period for which the external
synchronization input is applied.
INV.
NORM.
⑤
INV.: The output is ON when the sensor signal input is High.
NORM.: The output is ON when the sensor signal input is Low.
PLC
HUMAN
Sensor 1 output
operation mode switch
Selects the output operation.
Selects the timer period.
MACHINE
INTERFACES
⑥
⑦
INV.
NORM.
1sec.
10sec.
Timer period
selection switch
⑫
⑬
ENERGY
Sensor 2 output
operation mode switch
INV.: The output is ON when the sensor signal input is High.
NORM.: The output is ON when the sensor signal input is Low.
1 sec.: Variable from 40 ms approx. to 1 sec. approx.
10 sec.: Variable from 0.4 sec. approx. to 10 sec. approx.
Selects the timer operation.
MANAGEMENT
SOLUTIONS
Indicates the state of the sensor signal input. The
operation differs according to the mode set with ⑤
Sensor signal input selection switch.
INV.: Lights up when the sensor signal input is High.
NORM.: Lights up when the sensor signal input is Low.
FA
A
B
C
D
OFF-delay ONE SHOT
Ineffective
ON-delay
COMPONENTS
Sensor signal input
indicator (Red LED)
Timer operation
mode switch
⑧
⑨
MACHINE
VISION
SYSTEMS
UV
External
Indicates the state of the external synchronization
CURING
SYSTEMS
⑭
⑮
Timer adjuster Set the timer period.
Terminal block
synchronization input input. Lights up when the external synchronization
input does not disable the output.
indicator (Red LED)
Block diagrams (The diagrams below explain NPS’s operation in a simple manner. The actual circuits may differ slightly.)
NPS-C7
NPS-C7W
Sensor
Mounting
Stand
Sensor 1 output operation mode switch
12 V
Sensor signal input selection switch
INV.
12 V
Sensor
Checker
Sensor
Relay
IN
Controller
IN 1
INV.
output 1
Other
Products
Relay output
Sensor 1
output indicator
INV.
AND
INV.
12 V
Open-collector
output
Sensor 2 output operation mode switch
12 V
NPS
ES
Relay
output 2
IN 2
INV.
Output indicator
Sensor 2
output indicator
INV.
NPS-CT7
Delay time selection switch
Timer adjuster
Sensor signal input selection switch
12 V
IN
INV.
Relay output
OND
OFD
Sensor signal
input indicator
INV.
Gate/Edge trigger
operation mode switch
AND
OSD
External synchronization operation mode switch
12 V
Without timer
Open-collector
output
ES
INV.
Edge
Output indicator
External synchronization
input indicator
Timer operation mode switch
ON/OFF Input Sensor Controller NPS SERIES
965
FIBER
PRECAUTIONS FOR PROPER USE
Refer to p.1595 for general precautions.
SENSORS
LASER
SENSORS
Timer functions (NPS-CT7 only)
PHOTO-
ELECTRIC
SENSORS
• NPS-CT7 has three types of
convenient built-in timer functions.
Selection switch and timer operation
MICRO
PHOTO-
Sensor signal
input
Switch setting
ELECTRIC
SENSORS
High
• ON-delay (OND)
Output
operation
Sensor signal
input selection
Timer operation
selection
AREA
SENSORS
Low
ON
<Function>:
Neglects short output signals.
<Application>:
As only long signals are extracted,
this function is useful for detecting if
a line is choked or for sensing only
objects taking a long time to travel.
SAFETY LIGHT
Input not
inverted normal
operation
OND
N
O
N
O
S
D
CURTAINS
/
SAFETY
COMPONENTS
OFD
OFF
ON
PRESSURE /
FLOW
Input not
inverted
ON-delay
OND
OFD
N
O
N
O
S
D
SENSORS
T
INDUCTIVE
PROXIMITY
SENSORS
OFF
ON
INV.
NORM
.
Input not
inverted
OFF-delay
OND
OFD
N
O
N
O
S
D
T
T
T
T
PARTICULAR
USE
• OFF-delay (OFD)
OFF
ON
SENSORS
<Function>:
Extends the output signal for a fixed
period of time.
Input not
inverted
ONE SHOT
OND
OFD
N
O
N
O
S
D
SENSOR
OPTIONS
T
T
OFF
ON
SIMPLE
WIRE-SAVING
UNITS
<Application>:
Input inverted
normal
operation
OND
OFD
N
O
N
O
S
D
This function is useful if the output
signal is so short that the connected
device cannot respond.
OFF
ON
WIRE-SAVING
SYSTEMS
OND
OFD
N
O
N
O
S
D
Input inverted
ON-delay
T
T
T
MEASURE-
MENT
• ONE SHOT (OSD)
OFF
ON
SENSORS
INV.
NORM
.
<Function>:
Outputs a fixed width signal upon sensing.
<Application>:
This function is useful when the input
specifications of the connected device
require a signal of fixed width. Of course,
it is also useful for extending a short width
signal to a desired width.
STATIC
CONTROL
DEVICES
OND
OFD
N
O
N
O
S
D
Input inverted
OFF-delay
T
OFF
ON
LASER
MARKERS
OND
OFD
N
O
N
O
S
D
Input inverted
ONE SHOT
T
T
T
OFF
PLC
Timer period: T=Switchable, either 40 ms approx. to 1 sec. approx., or 0.4 sec. approx. to 10 sec. approx.
HUMAN
MACHINE
INTERFACES
Various other applications are possible.
ENERGY
MANAGEMENT
SOLUTIONS
External synchronization function (NPS-C7, NPS-CT7 only)
• Gate trigger
FA
COMPONENTS
• Edge trigger (NPS-CT7 only)
MACHINE
VISION
The output is disabled when the external synchronization
input is Low [mode selection switch on NORM. (Note)] or
is High [mode selection switch on INV. (Note)].
The sensor signal is judged at the instant the external
synchronization input rises up or falls down.
This sensor is ideal for cap presence detection that
would have required two controllers in the past.
SYSTEMS
UV
CURING
SYSTEMS
Effective
condition for
making output ON
Sensor signal
input
(
)
Example: Detecting presence of cap on bottle
Ineffective
Conventional
NPS-CT7
Sensor
Mounting
Stand
Sensor for sensing
Sensor signal input
Effective
Sensor signal input
External
synchronization
input
Sensor
Checker
Ineffective
condition for
disabling output
Sensor
Controller
Output
(
)
Controller
External
Output
NPS-CT7
Other
Products
synchronization
ON
input
External
Controller
with timer
synchronization
input
Output
OFF
NPS
Synchronizing
sensor
Note: Since NPS-C7 is not incorporated with the selection switch, the output
is disabled only when the external synchronization input is Low.
Effective
condition for
No cap
Cap present
(
(
)
making output ON
Sensor signal
input
Ineffective
Effective
Ineffective
External
synchronization
input
condition for
disabling output
)
t: 5 μs approx.
ON
Output
OFF
Note: As the output time ‘t’ is only 5 μs approx., extend it by using the OFF-
delay timer or the ONE SHOT timer.
Mounting
• To mount NPS with screws, use M4 screws.
The tightening torque should be 0.78 N•m or less.
ON/OFF Input Sensor Controller NPS SERIES
966
PRECAUTIONS FOR PROPER USE
FIBER
Refer to p.1595 for general precautions.
SENSORS
LASER
SENSORS
Wiring
PHOTO-
• Make sure that the power supply is off while wiring.
• Verify that the supply voltage variation is within the rating.
• Dimensions of suitable crimp terminals
ELECTRIC
SENSORS
(Unit: mm in)
MICRO
Y-shaped type
Round type
PHOTO-
ELECTRIC
SENSORS
Ø3.2 Ø0.126
or more
3.2 0.126
or more
10 0.394
or less
• Short-circuit protection plate
10 0.394
or less
AREA
SENSORS
6 0.236
or less
6 0.236
or less
The short-circuit protection plate
is attached to terminal No. 1 to
prevent AC short-circuit. Flip
6 0.236
or less
6 0.236
or less
SAFETY LIGHT
Short-circuit
protection plate
CURTAINS
SAFETY
/
19 0.748
or less
19 0.748
or less
COMPONENTS
the plate up, connect the wire
to terminal No. 1, and then flip
it down.
PRESSURE /
FLOW
(When crimped)
(When crimped)
SENSORS
Note: Use crimp terminals having insulation sleeves.
Recommended crimp terminal: Nominal size 1.25-3.0
INDUCTIVE
PROXIMITY
SENSORS
The short-circuit protection plate is attached
at the time of shipment from our factory.
PARTICULAR
USE
• NPS-C7 and NPS-CT7 do not incorporate a short-circuit
protection at the NPN open-collector transistor output.
Do not connect them directly to a power supply or a
capacitive load.
• The response time of the NPN open-collector transistor
output of NPS-C7 or NPS-CT7 is 5 μs. If a relay or a
micro-switch (mechanical contact) is connected, take
care since its bounce may result in output chattering.
SENSORS
• Short bar
SENSOR
OPTIONS
The short bar saves wiring when a common power supply
is used for the AC supply terminal and the load supply of
the relay contact output.
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
The short bar is attached between the terminal Nos. 1 and 2 at the time of shipment from
our factory. To use a separate power supply for the output relay, make sure to remove it.
MEASURE-
MENT
• Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway. This can
cause malfunction due to induction.
SENSORS
Typical wiring diagram
STATIC
CONTROL
DEVICES
Terminal No.
LASER
Power
supply
circuit
⑤
MARKERS
Others
Power supply
①
②
③
④
• Do not use during the initial transient time (0.5 sec.) after
the power supply is switched on.
• Avoid dust, dirt, and steam.
• Take care that the controller does not come in direct
contact with water, oil, grease, or organic solvents, such
as, thinner, etc.
PLC
Load
Short-circuited
with the short
bar
1
HUMAN
MACHINE
INTERFACES
ENERGY
Short bar
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from our website.
MACHINE
VISION
SYSTEMS
NPS-□
UV
CURING
SYSTEMS
External synchronization
Sensor signal
Assembly dimensions with attached protection cover
input indicator (Red)
Power
input indicator (Red)
Output indicator (Red)
Short-circuit
protection plate
indicator (Red)
Sensor
Mounting
Stand
Short bar
Sensor
Checker
Mode selection switches
Timer adjuster
Sensor
32
1.260
80
3.150
Controller
80
3.150
32
1.260
Other
Products
NPS
(83.5)
(3.287)
80 3.150
7.5
0.295
Suitable for 35 mm 1.378 in width DIN rail
2-4.5 × 5.5 0.177 × 0.217 oblong holes
22 0.866
70
2.756
Notes: 1) The above drawing illustrates the dimensions of NPS-CT7.
The dimensions of NPS-C7 and NPS-C7W are identical to those
given above.
2) The front panel of each model is different.
Refer to p.964 for more details of the front panels.
相关型号: