T115A-AF [PANASONIC]

Snap Switches Capable of 15A Switching;
T115A-AF
型号: T115A-AF
厂家: PANASONIC    PANASONIC
描述:

Snap Switches Capable of 15A Switching

文件: 总21页 (文件大小:1105K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Automation Controls Catalog  
Snap Switches Capable of  
15A Switching  
T-15 Series  
Switches  
FEATURES  
12dia.  
Toggle  
Push-  
button  
• Series includes rocker and push-button switches.  
Sealed type available for use in different environments.  
• Rubber cap also available in silicon type for excellent  
weather resistance.  
Square  
hole  
Rocker  
These switches are only for Industrial use.  
Do not use any other applications. (ex. home use)  
ASSORTMENT  
Sealed type  
Number of pole  
Shape of terminal  
.250  
Standard  
Kind of actuator  
type  
Panel-  
sealed  
type  
Terminal-  
sealed  
type  
Wire leads  
type  
Solder  
terminal  
Screw  
Quick-  
connect  
terminal  
1P  
2P  
3P  
4P  
Wire lead  
terminal  
Toggle type  
Rocker type  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available Available*1 Available*1 Available  
Available Available*1 Available*2  
Available  
Available  
Available  
Available  
Available  
Available  
Available*2  
Push-button type Available  
Notes: *1: Only standard type  
*2: Only wire leads type  
TOGGLE TYPES  
■Standard type  
1) Solder terminal and .250 Quick-connect terminal  
Solder terminal  
Part No.  
T115A-F  
T115D-F  
T115E-F  
T115F-F  
T115G-F  
T115H-F  
T215K-F  
T215N-F  
T215P-F  
T215R-F  
T215S-F  
T215T-F  
T315K-F  
T315N-F  
T315P-F  
T415K-F  
T415N-F  
T415P-F  
.250 Quick-connect terminal  
Part No.  
Kind of operation  
Number of poles  
< >: Momentary position  
ON-OFF  
ON-ON  
T115A-AF  
T115D-AF  
T115E-AF  
T115F-AF  
ON-OFF-ON  
1-pole  
ON-<ON>  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
T115G-AF  
T115H-AF  
T215K-AF  
T215N-AF  
T215P-AF  
T215R-AF  
T215S-AF  
T215T-AF  
ON-ON  
ON-OFF-ON  
2-pole  
ON-<ON>  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
T315K-AF  
T315N-AF  
T315P-AF  
T415K-AF  
T415N-AF  
T415P-AF  
3-pole  
4-pole  
ON-ON  
ON-OFF-ON  
ON-OFF  
ON-ON  
ON-OFF-ON  
Note: Standard installation accessories are included with the product.  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
AECTB5E 201906  
2019.06  
ー 1 ー  
T-15 Series Switches  
2) Screw terminal  
Screw terminal  
Part No.  
Kind of operation  
< >: Momentary position  
Number of poles  
ON-OFF  
ON-ON  
T115A-SF  
T115D-SF  
T115E-SF  
T115F-SF  
T115G-SF  
T115H-SF  
T215K-SF  
T215N-SF  
T215P-SF  
T215R-SF  
T215S-SF  
T215T-SF  
T315K-SF  
T315N-SF  
T315P-SF  
T415K-SF  
T415N-SF  
T415P-SF  
ON-OFF-ON  
ON-<ON>  
1-pole  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
ON-ON  
ON-OFF-ON  
ON-<ON>  
2-pole  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
3-pole  
4-pole  
ON-ON  
ON-OFF-ON  
ON-OFF  
ON-ON  
ON-OFF-ON  
Note: Standard installation accessories are included with the product.  
■Panel-sealed type  
1) Solder terminal  
Solder terminal  
Part No.  
Kind of operation  
Number of poles  
< >: Momentary position  
ON-OFF  
ON-ON  
TP115A-F  
TP115D-F  
TP115E-F  
TP115F-F  
TP115G-F  
TP115H-F  
TP215K-F  
TP215N-F  
TP215P-F  
TP215R-F  
TP215S-F  
TP215T-F  
ON-OFF-ON  
1-pole  
ON-<ON>  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
ON-ON  
ON-OFF-ON  
2-pole  
ON-<ON>  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
Note: Of the standard installation accessories that come with the product, the front hex nut and lock washer are included.  
2) Screw terminal  
Screw terminal  
Kind of operation  
< >: Momentary position  
Number of poles  
Part No.  
ON-OFF  
ON-ON  
TP115A-SF  
TP115D-SF  
TP115E-SF  
TP115F-SF  
TP115G-SF  
TP115H-SF  
TP215K-SF  
TP215N-SF  
TP215P-SF  
TP215R-SF  
TP215S-SF  
TP215T-SF  
ON-OFF-ON  
ON-<ON>  
1-pole  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
ON-ON  
ON-OFF-ON  
ON-<ON>  
2-pole  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
Note: Of the standard installation accessories that come with the product, the front hex nut and lock washer are included.  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
AECTB5E 201906  
ー 2 ー  
T-15 Series Switches  
■Terminal-sealed type  
1) Solder terminal  
Solder terminal  
Part No.  
Kind of operation  
< >: Momentary position  
Number of poles  
ON-OFF  
ON-ON  
TD115A-F  
TD115D-F  
TD115E-F  
TD115F-F  
TD115G-F  
TD115H-F  
TD215K-F  
TD215N-F  
TD215P-F  
TD215R-F  
TD215S-F  
TD215T-F  
ON-OFF-ON  
ON-<ON>  
1-pole  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
ON-ON  
ON-OFF-ON  
ON-<ON>  
2-pole  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
Note: Of the standard installation accessories that come with the product, the front hex nut and lock washer are included.  
2) Screw terminal  
Screw terminal  
Kind of operation  
< >: Momentary position  
Number of poles  
Part No.  
ON-OFF  
ON-ON  
TD115A-SF  
TD115D-SF  
TD115E-SF  
TD115F-SF  
TD115G-SF  
TD115H-SF  
TD215K-SF  
TD215N-SF  
TD215P-SF  
TD215R-SF  
TD215S-SF  
TD215T-SF  
ON-OFF-ON  
ON-<ON>  
1-pole  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
ON-ON  
ON-OFF-ON  
ON-<ON>  
2-pole  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
Note: Of the standard installation accessories that come with the part, the front hex nut and lock washer are included.  
■Wire lead type  
Wire lead type  
Part No.  
Kind of operation  
< >: Momentary position  
Number of poles  
ON-OFF  
ON-ON  
TC115A-F  
TC115D-F  
TC115E-F  
TC115F-F  
TC115G-F  
TC115H-F  
TC215K-F  
TC215N-F  
TC215P-F  
TC215R-F  
TC215S-F  
TC215T-F  
ON-OFF-ON  
ON-<ON>  
1-pole  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
ON-ON  
ON-OFF-ON  
ON-<ON>  
2-pole  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
Note: 1. Of the standard installation accessories that come with the part, the front hex nut and lock washer are included.  
2. 300 V vinyl wire (VSF, thick: 2 mm2, length: 200 mm) is used. Please inquire about type and different length of lead wire.  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
AECTB5E 201906  
ー 3 ー  
T-15 Series Switches  
■Accessories  
1) Installation accessories (Repair parts)  
Optional installation  
accessories  
Standard installation accessories  
Product name  
Front hex nut  
Back hex nut  
(Uni-chrome plated)  
Front Knurl nut  
(Nickel plated)  
Keying washer  
Lock washer  
(Nickel plated)  
1
ꢈ1ꢆ ꢉ 1  
1ꢂꢁꢀ ꢃiꢄꢁ  
1ꢀꢁꢅ ꢃiꢄꢁ  
ꢅ1ꢃ ꢆ 1  
ꢈ1ꢆ ꢉ 1  
Dimensions  
(Unit: mm)  
ꢁ1ꢂꢃ1ꢄꢅ  
ꢁ1ꢂꢃ1ꢄꢅ  
ꢆꢀ5  
ꢇꢁꢈ  
1ꢄꢀꢅ ꢂiꢃꢀ  
ꢃꢂꢄ  
ꢆꢃꢇ  
1ꢀ  
1
ꢆꢃꢇ  
15ꢀꢁ ꢂiꢃꢀ  
ꢀꢁꢂ  
ꢀꢁꢆ  
1ꢀ  
15 ꢀiꢁꢂ  
Part No.  
AJ3081  
AJ3082  
AJ3083  
AJ3084  
AJ3080  
Note: A selling unit of each accessory is 10 pieces.  
Using the different rubber caps  
We recommend silicon rubber and EP rubber caps for the following applications.  
1) Silicon rubber type  
2) EP rubber type  
• When it is necessary to differentiate by color.  
• When using in applications that require resistance to heat and  
cold. Ambient temperature: –25°C to +85°C (EP rubber type is  
0°C to +40°C.)  
When cost is the primary consideration.  
• When compactness is required.  
2) Accessories (Option)  
Indication plate (aluminum) (Note 3)  
Product name  
Rubber cap (Note 1, 2, 4, 5)  
ON-OFF  
ON-ON  
EP rubber type  
Silicone rubber type  
1ꢀꢁꢂ ꢃiꢄꢁ  
1ꢀꢁꢂ ꢃiꢄꢁ  
ꢀ ꢁiꢂꢃ  
1ꢀ ꢁiꢂꢃ  
ꢄꢅꢃ5  
ꢄꢅꢃ5  
ꢀꢃꢇ  
1ꢁꢂ  
1ꢁꢂ  
Dimensions  
(Unit: mm)  
ꢂꢆ  
ꢂꢆ  
1ꢁ5  
1ꢁ5  
ꢆꢁꢇ  
ꢆꢁꢇ  
ꢆ1ꢄ  
ꢆ1ꢄ  
1ꢅ  
1ꢈ  
1ꢅ  
1ꢈ  
ꢄ1 ꢁiꢂꢃ  
1ꢀ ꢁiꢂꢃ  
ꢆꢁꢇ  
ꢆꢁꢇ  
Part No.  
WD1901  
WD1902  
WD1911  
WD1811  
*
Notes: 1. The asterisk “∗” in the part number WD1811∗ for the silicon rubber type rubber cap is where the letter representing the color should be inserted.  
(B: black; R: red; Z: grey; Y: yellow; G: green.)  
2. EP rubber cap is available in black only.  
3. Letters on the display panel are aluminum colored and the area surrounding the letters is black.  
4. Indication plate and rubber cap are compatible with the T-15 series switch, T-10 series switch, and T-03/T-06 series switches  
(when plate thickness is 2.7 mm or less).  
5. Applicable EP rubber type switches are only available in ON-OFF, ON-ON, ON <- ON>, and <ON>-OFF <- ON>. “< >”: Momentary position  
ROCKER TYPES  
■Standard type  
1) Solder terminal, without indication on actuator  
Solder terminal  
Part No.  
Kind of operation  
< >: Momentary position  
Number of poles  
ON-OFF  
ON-ON  
TR115A- F  
*
TR115D- F  
*
ON-OFF-ON  
ON-<ON>  
TR115E- F  
*
1-pole  
TR115F- F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
TR115G- F  
*
TR115H- F  
*
TR215K- F  
*
ON-ON  
TR215N- F  
*
ON-OFF-ON  
ON-<ON>  
TR215P- F  
*
2-pole  
TR215R- F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
TR215S- F  
*
TR215T- F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
AECTB5E 201906  
ー 4 ー  
T-15 Series Switches  
2) Screw terminal, without indication on actuator  
Screw terminal  
Part No.  
Kind of operation  
Number of poles  
< >: Momentary position  
ON-OFF  
ON-ON  
TR115A-S F  
*
TR115D-S F  
*
ON-OFF-ON  
TR115E-S F  
*
1-pole  
ON-<ON>  
TR115F-S F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
TR115G-S F  
*
TR115H-S F  
*
TR215K-S F  
*
ON-ON  
TR215N-S F  
*
ON-OFF-ON  
TR215P-S F  
*
2-pole  
ON-<ON>  
TR215R-S F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
TR215S-S F  
*
TR215T-S F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
3) Solder terminal, with ON-OFF indication on actuator  
Solder terminal  
Number of poles  
Kind of operation  
Part No.  
TR115A- F  
1-pole  
2-pole  
ON-OFF  
ON-OFF  
*
TR215K- F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
4) Screw terminal, with ON-OFF indication on actuator  
Screw terminal  
Number of poles  
Kind of operation  
Part No.  
TR115A-S F  
1-pole  
2-pole  
ON-OFF  
ON-OFF  
*
TR215K-S F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
■Panel-sealed type  
1) Solder terminal, without indication on actuator  
Solder terminal  
Part No.  
Kind of operation  
< >: Momentary position  
Number of poles  
ON-OFF  
ON-ON  
TRP115A- F  
*
TRP115D- F  
*
ON-OFF-ON  
ON-<ON>  
TRP115E- F  
*
1-pole  
TRP115F- F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
TRP115G- F  
*
TRP115H- F  
*
TRP215K- F  
*
ON-ON  
TRP215N- F  
*
ON-OFF-ON  
ON-<ON>  
TRP215P- F  
*
2-pole  
TRP215R- F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
TRP215S- F  
*
TRP215T- F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
2) Screw terminal, without indication on actuator  
Screw terminal  
Part No.  
Kind of operation  
< >: Momentary position  
Number of poles  
ON-OFF  
ON-ON  
TRP115A-S F  
*
TRP115D-S F  
*
ON-OFF-ON  
ON-<ON>  
TRP115E-S F  
*
1-pole  
TRP115F-S F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
TRP115G-S F  
*
TRP115H-S F  
*
TRP215K-S F  
*
ON-ON  
TRP215N-S F  
*
ON-OFF-ON  
ON-<ON>  
TRP215P-S F  
*
2-pole  
TRP215R-S F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
TRP215S-S F  
*
TRP215T-S F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
AECTB5E 201906  
ー 5 ー  
T-15 Series Switches  
3) Solder terminal, with ON-OFF indication on actuator  
Solder terminal  
Part No.  
Number of poles  
Kind of operation  
1-pole  
2-pole  
ON-OFF  
ON-OFF  
TRP115A- 1F  
*
TRP215K- 1F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
4) Screw terminal, with ON-OFF indication on actuator  
Screw terminal  
Number of poles  
Kind of operation  
Part No.  
TRP115A-S 1F  
1-pole  
2-pole  
ON-OFF  
ON-OFF  
*
TRP215K-S 1F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
■Terminal-sealed type  
1) Solder terminal, without indication on actuator  
Solder terminal  
Part No.  
Kind of operation  
< >: Momentary position  
Number of poles  
ON-OFF  
ON-ON  
TRD115A- F  
*
TRD115D- F  
*
ON-OFF-ON  
ON-<ON>  
TRD115E- F  
*
1-pole  
TRD115F- F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
TRD115G- F  
*
TRD115H- F  
*
TRD215K- F  
*
ON-ON  
TRD215N- F  
*
ON-OFF-ON  
ON-<ON>  
TRD215P- F  
*
2-pole  
TRD215R- F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
TRD215S- F  
*
TRD215T- F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
2) Screw terminal, without indication on actuator  
Screw terminal  
Part No.  
Kind of operation  
< >: Momentary position  
Number of poles  
ON-OFF  
ON-ON  
TRD115A-S F  
*
TRD115D-S F  
*
ON-OFF-ON  
ON-<ON>  
TRD115E-S F  
*
1-pole  
TRD115F-S F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
TRD115G-S F  
*
TRD115H-S F  
*
TRD215K-S F  
*
ON-ON  
TRD215N-S F  
*
ON-OFF-ON  
ON-<ON>  
TRD215P-S F  
*
2-pole  
TRD215R-S F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
TRD215S-S F  
*
TRD215T-S F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
3) Solder terminal, with ON-OFF indication on actuator  
Solder terminal  
Number of poles  
Kind of operation  
Part No.  
TRD115A- 1F  
1-pole  
2-pole  
ON-OFF  
ON-OFF  
*
TRD215K- 1F  
*
Note: Please specify the actuator color by replacing the asterisk “∗” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
4) Screw terminal, with ON-OFF indication on actuator  
Screw terminal  
Number of poles  
Kind of operation  
Part No.  
TRD115A-S 1F  
1-pole  
2-pole  
ON-OFF  
ON-OFF  
*
TRD215K-S 1F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
AECTB5E 201906  
ー 6 ー  
T-15 Series Switches  
■Wire lead sealed type  
1) Without indication on actuator  
Wire lead type  
Part No.  
Kind of operation  
< >: Momentary position  
Number of poles  
ON-OFF  
ON-ON  
TRC115A- F  
*
TRC115D- F  
*
ON-OFF-ON  
ON-<ON>  
TRC115E- F  
*
1-pole  
TRC115F- F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
ON-OFF  
TRC115G- F  
*
TRC115H- F  
*
TRC215K- F  
*
ON-ON  
TRC215N- F  
*
ON-OFF-ON  
ON-<ON>  
TRC215P- F  
*
2-pole  
TRC215R- F  
*
<ON>-OFF-<ON>  
ON-OFF-<ON>  
TRC215S- F  
*
TRC215T- F  
*
Note: Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
2) With ON-OFF indication on actuator  
Wire lead type  
Number of poles  
Kind of operation  
Part No.  
TRC115A- 1F  
1-pole  
2-pole  
ON-OFF  
ON-OFF  
*
TRC215K- 1F  
*
Notes: 1. Please specify the actuator color by replacing the asterisk “ ” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey)  
*
2. 300 V vinyl wire (VSF, thick: 2 mm2, length: 200 mm) is used. Please inquire about type and different length of lead wire.  
PUSH-BUTTON PRODUCT TYPES  
■Standard type  
1) Solder terminal  
Solder terminal  
Number of poles  
Kind of operation  
Part No.  
TB110F-F  
TB115D-F  
TB210R-F  
TB215N-F  
Momentary  
Alternate  
1-pole  
2-pole  
Momentary  
Alternate  
2) Screw terminal  
Screw terminal  
Part No.  
Number of poles  
Kind of operation  
Momentary  
Alternate  
TB110F-SF  
TB115D-SF  
TB210R-SF  
TB215N-SF  
1-pole  
2-pole  
Momentary  
Alternate  
Notes: 1. Please use switch body with a color cap (sold separately).  
2. Standard installation accessories are included with the product.  
ꢉꢁꢂꢁr cꢃꢄ  
ꢊsꢁꢂꢆ seꢄꢃrꢃteꢂꢈꢋ  
ꢀith cꢁꢂꢁr  
cꢃꢄ iꢅstꢃꢂꢂeꢆ  
Switch ꢇꢁꢆꢈ  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
AECTB5E 201906  
ー 7 ー  
T-15 Series Switches  
■Panel-sealed type  
1) Solder terminal  
Solder terminal  
Part No.  
Number of poles  
Kind of operation  
Momentary  
Alternate  
TBP110F-F  
TBP115D-F  
TBP210R-F  
TBP215N-F  
1-pole  
Momentary  
Alternate  
2-pole  
2) Screw terminal  
Screw terminal  
Part No.  
Number of poles  
Kind of operation  
Momentary  
Alternate  
TBP110F-SF  
TBP115D-SF  
TBP210R-SF  
TBP215N-SF  
1-pole  
2-pole  
Momentary  
Alternate  
Notes: 1. Please use switch body with a color cap (sold separately).  
2. Standard installation accessories are included with the product.  
ꢉꢁꢂꢁr cꢃꢄ  
ꢊsꢁꢂꢆ seꢄꢃrꢃteꢂꢈꢋ  
ꢀith cꢁꢂꢁr  
cꢃꢄ iꢅstꢃꢂꢂeꢆ  
Switch ꢇꢁꢆꢈ  
■Color cap for push-button (Option)  
Color cap  
Product name  
(sold separately)  
1ꢂꢀꢁ ꢃiꢄꢀ  
Dimensions  
(Unit: mm)  
11ꢀꢁ  
Note: Please specify the color cap color by replacing the asterisk “*” in the part number with appropriate letter  
Part No.  
WDB1821  
*
(B: black; W: white; R: red; Z: dark grey; H: light grey; Y: yellow; G: green; L: blue).  
Installation accessories (Repair parts)  
Optional installation  
Standard installation accessories  
accessories  
Product name  
Front hex nut  
Back hex nut  
Front Knurl nut  
(Nickel plated)  
Keying washer  
Lock washer  
(Nickel plated)  
(Uni-chrome plated)  
1
ꢈ1ꢆ ꢉ 1  
1ꢂꢁꢀ ꢃiꢄꢁ  
1ꢀꢁꢅ ꢃiꢄꢁ  
ꢅ1ꢃ ꢆ 1  
ꢈ1ꢆ ꢉ 1  
Dimensions  
(Unit: mm)  
ꢁ1ꢂꢃ1ꢄꢅ  
ꢁ1ꢂꢃ1ꢄꢅ  
ꢆꢀ5  
ꢇꢁꢈ  
1ꢄꢀꢅ ꢂiꢃꢀ  
ꢃꢂꢄ  
ꢆꢃꢇ  
1ꢀ  
1
ꢆꢃꢇ  
15ꢀꢁ ꢂiꢃꢀ  
ꢀꢁꢂ  
ꢀꢁꢆ  
1ꢀ  
15 ꢀiꢁꢂ  
Part No.  
AJ3081  
AJ3082  
AJ3083  
AJ3084  
AJ3080  
Note: A selling unit of each accessory is 10 pieces.  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
AECTB5E 201906  
ー 8 ー  
T-15 Series Switches  
SPECIFICATIONS  
■Contact rating  
1) Toggle type and Rocker type  
Kind of load  
AC rating  
15A 250V  
DC rating  
Resistive load  
0.5A 250V, 0.9A 125V, 15A 30V  
0.3A 250V (Time constant: 8 ms),  
0.5A 125V (Time constant: 8 ms)  
15A 30V (Time constant: 8 ms)  
Inductive load  
15A 250V (Power factor: 0.6)  
2) Push-button type (momentary)  
Kind of load  
AC rating  
10A 250V  
DC rating  
Resistive load  
0.4A 250V, 0.8A 125V, 8A 30V  
3) Push-button type (alternate)  
Kind of load  
AC rating  
15A 250V  
DC rating  
Resistive load  
0.5A 250V, 0.9A 125V, 15A 30V  
■Characteristics  
Item  
Specifications  
Shape of actuator  
Toggle type  
Rocker type  
Push-button type  
Min. 5×104 (20 cpm)  
ON-OFF, ON-ON,  
ON-OFF-ON,  
Mechanical expected life  
1-pole and 2-pole: Min. 105  
3-pole and 4-pole: Min. 8.5×104  
Min. 3×104 (20 cpm)  
Min. 3×104 (20 cpm)  
ON-(ON), (ON)-OFF-(ON),  
ON-OFF-(ON)  
Standard type: Min. 3×104  
Electrical expected life  
(10 cpm)  
Standard and panel-sealed types: Min. 3×104  
Terminal-sealed and wire leads types: Min. 1.5×104  
Panel-sealed, terminal-sealed  
Min. 104  
and wire leads types: Min. 104  
Dielectric strength  
1500 Vrms (at detection current: 10mA)  
Insulation resistance  
Min. 100 MΩ (at 500 V DC measured by insulation resistive meter)  
Initial, Max. 10 mΩ (By voltage drop at 1 A, 2 to 4 V DC)  
Wire leads type only: Initial, Max. 30 mΩ (By voltage drop at 1 A, 2 to 4 V DC)  
Contact resistance  
Actuator strength  
112.7N for 1 min. (For operating direction)  
Vibration resistance  
10 to 55 Hz at double amplitude of 1.5 mm (contact opening: Max. 10 ms)  
Terminal strength (static  
load)  
24.5N for 1 min.  
Ambient temperature  
Contact material  
–25°C to +70°C (Not freezing below 0°C)  
AgZnO alloy  
DATA (Electrical life, For toggle standard type)  
Tested condition: 250 V AC, Power factor: 0.6 and 10 cpm  
1ꢏ  
ꢍ-ꢇꢈꢉe ꢊꢂꢋ ꢎ-ꢇꢈꢉe tꢌꢇes  
ꢆ-ꢇꢈꢉe ꢊꢂꢋ 1ꢇꢈꢉe tꢌꢇes  
5
1
1ꢏ 1ꢍ 1ꢒ ꢆꢆ ꢆꢐ ꢎꢏ  
ꢀꢁrreꢂt ꢃꢄꢅ  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
AECTB5E 201906  
ー 9 ー  
T-15 Series Switches  
(Unit: mm) General tolerance: ±0.5  
TOGGLE TYPE DIMENSIONS  
The CAD data of the products with a CAD Data mark can be downloaded from https://industrial.panasonic.com/ac/e/  
■Standard type  
1) Solder terminal  
External dimensions  
ꢁ-ꢗꢋꢌe  
ꢃ-ꢗꢋꢌe  
CAD Data  
1-ꢙꢍꢎe  
ꢁ-ꢙꢍꢎe  
ꢖꢃꢕ  
ꢖꢃ  
ꢁꢇꢕ  
ꢁꢇꢕ  
ꢗꢃꢖ  
ꢗꢘꢖ  
ꢀꢕꢖ  
ꢀꢕꢖ  
ꢖꢇꢑꢃꢕ  
ꢖꢇꢑꢃꢕ  
1ꢄꢑ5ꢕ  
ꢗꢕꢄꢃꢖ  
ꢘeꢙwꢎꢙ  
ꢈ1ꢆꢉ1  
ꢘeꢙwꢎꢙ  
ꢈ1ꢆꢉ1  
ꢗꢕꢄꢃꢖ  
1ꢄꢑ5ꢕ  
1ꢅꢄ5ꢖ  
1ꢅꢄ5ꢖ  
ꢉeꢊwꢋꢊ  
ꢇ1ꢁꢈ1  
ꢉeꢊwꢋꢊ  
ꢇ1ꢁꢈ1  
ꢖꢇꢑꢃꢕ  
ꢖꢇꢑꢃꢕ  
ꢗꢕꢄꢃꢖ  
1ꢆꢕ  
ꢗꢕꢄꢃꢖ  
1ꢆꢕ  
1ꢁꢖ  
1ꢁꢖ  
ꢆꢄ  
ꢆꢄ  
ꢁꢀꢄꢅ  
ꢁꢅ  
ꢁꢆ  
ꢊꢋꢌe ꢍꢋr wire  
ꢌeꢎꢏsꢐ ꢆ ꢏiꢎꢑ  
ꢒeꢓꢔthꢐ ꢃ  
ꢊꢋꢌe ꢍꢋr wire  
ꢌeꢎꢏsꢐ ꢆ ꢏiꢎꢑ  
ꢒeꢓꢔthꢐ ꢃ  
ꢁꢁ  
ꢁꢁ  
ꢌꢍꢎe ꢏꢍr wire  
ꢎeꢋꢐsꢑ ꢁ ꢐiꢋꢄ  
ꢒeꢓꢔthꢑ ꢃ  
ꢌꢍꢎe ꢏꢍr wire  
ꢎeꢋꢐsꢑ ꢁ ꢐiꢋꢄ  
ꢒeꢓꢔthꢑ ꢃ  
ꢀꢀ  
ꢆꢅ  
ꢁꢂꢑ5  
1ꢆꢄ5  
15ꢄꢘ  
Note: ON-OFF type does not have terminal No. 2, 5, 8 and 11.  
2) Screw terminal (M3.5)  
External dimensions  
ꢄ-ꢍꢎꢏe  
ꢄꢅꢋ  
ꢈ-ꢍꢎꢏe  
ꢄꢅꢋ  
CAD Data  
1-ꢍꢎꢏe  
ꢅꢉꢊ  
ꢃ-ꢍꢎꢏe  
ꢅꢉꢊ  
ꢌꢈꢋ  
ꢌꢈꢋ  
ꢋꢌꢊ  
ꢋꢁ  
ꢌꢅꢃꢈꢋ  
ꢌꢅꢃꢈꢋ  
1ꢇꢃ5ꢋ  
1ꢇꢃ5ꢋ  
ꢋꢉꢀꢌꢊ  
ꢐeꢑwꢊꢑ  
ꢒ1ꢀꢓ1  
ꢐeꢑwꢊꢑ  
ꢒ1ꢀꢓ1  
ꢋꢉꢀꢌꢊ  
1ꢄꢀ5ꢊ  
1ꢄꢀ5ꢊ  
ꢐeꢑwꢈꢑ  
ꢒ1ꢃꢓ1  
ꢐeꢑwꢈꢑ  
ꢒ1ꢃꢓ1  
ꢌꢅꢃꢈꢋ  
ꢌꢅꢃꢈꢋ  
1ꢀꢋ  
1ꢀꢋ  
ꢋꢉꢀꢌꢊ  
ꢋꢉꢀꢌꢊ  
1ꢃꢊ  
1ꢃꢊ  
ꢄꢅꢃꢄ  
ꢄꢅꢃꢄ  
ꢃꢄ  
ꢅꢉꢀꢅ  
ꢂꢀꢅ  
ꢂꢃꢄ  
ꢂꢃꢄ  
ꢂꢀꢅ  
ꢄꢄꢅꢃꢈ  
ꢄꢄꢅꢃꢈ  
ꢃꢂ  
ꢅꢅꢉꢀꢌ  
ꢀꢁ  
ꢄꢆꢃ5  
1ꢂꢀ5  
15ꢀꢁ  
Note: ON-OFF type does not have terminal No. 2, 5, 8 and 11.  
3) .250 Quick-connect terminal  
External dimensions  
ꢂ-ꢔꢐꢓe  
ꢊ-ꢔꢐꢓe  
CAD Data  
1-ꢔꢐꢓe  
ꢄ-ꢔꢐꢓe  
ꢉꢌꢈ  
ꢉꢌꢈ  
ꢂꢃꢈ  
ꢂꢃꢈ  
ꢋꢌꢊ  
ꢋꢆꢊ  
ꢈꢉꢊ  
ꢈꢉꢊ  
ꢉꢃꢁꢊꢈ  
ꢉꢃꢁꢊꢈ  
1ꢇꢁ5ꢈ  
ꢋꢉꢁꢌꢊ  
ꢋꢉꢁꢌꢊ  
1ꢇꢁ5ꢊ  
1ꢇꢁ5ꢈ  
ꢕeꢖwꢆꢖ  
ꢗ1ꢋꢘ1  
ꢕeꢖwꢆꢖ  
ꢗ1ꢋꢘ1  
1ꢇꢁ5ꢊ  
ꢕeꢖwꢃꢖ  
ꢗ1ꢄꢘ1  
ꢕeꢖwꢃꢖ  
ꢗ1ꢄꢘ1  
ꢉꢃꢁꢊꢈ  
ꢉꢃꢁꢊꢈ  
1ꢋꢈ  
1ꢋꢈ  
ꢋꢉꢁꢌꢊ  
ꢋꢉꢁꢌꢊ  
1ꢄꢊ  
1ꢄꢊ  
ꢂꢃꢁꢂ  
ꢂꢃꢁꢂ  
ꢄꢇ  
ꢈꢉꢁꢈ  
ꢀꢁꢂ  
ꢀꢁꢂ  
ꢅꢁꢈ  
ꢅꢁꢈ  
ꢄꢅ  
ꢂꢂ  
ꢂꢂ  
ꢀ-ꢁꢋ5ꢃ ꢍꢎicꢏ-  
cꢐꢑꢑect terꢒiꢑꢆꢓ  
1ꢋ-ꢁꢋ5ꢃ ꢍꢎicꢏ-  
cꢐꢑꢑect terꢒiꢑꢆꢓ  
ꢈꢈ  
ꢈ-ꢁꢄ5ꢉ ꢍꢎicꢏ-  
cꢐꢑꢑect terꢒiꢑꢃꢓ  
ꢀ-ꢁꢄ5ꢉ ꢍꢎicꢏ-  
cꢐꢑꢑect terꢒiꢑꢃꢓ  
ꢂꢄꢁ5  
ꢋꢌ  
1ꢅꢁ5  
15ꢁꢆ  
Notes: 1. ON-OFF type does not have terminal No. 2, 5, 8 and 11.  
2. There is no through-hole on .250 Quick-connect terminals.  
Panasonic Corporation Electromechanical Control Business Division  
© Panasonic Corporation 2019  
AECTB5E 201906  
industrial.panasonic.com/ac/e/  
ー 10 ー  
T-15 Series Switches  
■Panel-sealed type  
External dimensions  
1) Solder terminal  
2) Screw terminal (M3.5)  
1-ꢑꢒꢓe  
ꢄꢅꢆ  
ꢊ-ꢑꢒꢓe  
CAD Data  
1-ꢑꢒꢓe  
ꢅꢆꢎ  
ꢄ-ꢑꢒꢓe  
ꢇꢃꢆ  
ꢇꢈꢆ  
ꢄꢅꢆ  
ꢏꢐꢎ  
ꢏꢃꢎ  
ꢅꢆꢎ  
1ꢀꢁ5  
1ꢍꢀ5  
1ꢅ  
1ꢍꢀ5  
1ꢅ  
1ꢀꢁ5  
ꢉ1ꢊꢋ1  
ꢉ1ꢊꢋ1  
ꢍꢀ5  
1ꢃ ꢁiꢂꢀ  
ꢎ cꢏt  
1ꢃ ꢁiꢂꢀ  
ꢎ cꢏt  
ꢊ1ꢄꢋ1  
ꢀꢁ5  
ꢊ1ꢄꢋ1  
ꢀꢁ5  
1ꢃ ꢈiꢉꢁ  
ꢌ cꢍt  
1ꢃ ꢈiꢉꢁ  
ꢌ cꢍt  
ꢍꢀ5  
1ꢆ  
1ꢆ  
ꢄꢅꢁꢀ  
ꢊꢍ  
ꢄꢂꢁꢇ  
ꢄꢅꢀꢊ  
ꢌꢀꢄ  
ꢌꢀꢄ  
1ꢌꢀ5  
15ꢀꢃ  
1ꢇꢁ5  
15ꢁꢃ  
ꢊꢌ  
ꢄꢇ  
ꢅꢅ  
ꢄꢄ  
Note: ON-OFF type does not have terminal No. 2 and 5.  
■Terminal-sealed type  
External dimensions  
1) Solder terminal  
2) Screw terminal (M3.5)  
1-ꢏꢐꢑe  
ꢃꢂꢋ  
ꢄ-ꢏꢐꢑe  
ꢃꢂꢋ  
CAD Data  
1-ꢑꢒꢓe  
ꢅꢄꢉ  
ꢀ-ꢑꢒꢓe  
ꢅꢄꢉ  
ꢌꢊꢋ  
ꢌꢒꢋ  
ꢊꢋꢉ  
ꢊꢎꢉ  
1ꢀꢁ5  
1ꢂꢁꢃ  
1ꢀꢁ5  
1ꢂꢁꢃ  
ꢈ1ꢄꢉ1  
ꢀꢁ5  
ꢈ1ꢄꢉ1  
ꢀꢁ5  
1ꢆꢂ5  
1ꢄꢂꢅ  
ꢀꢅꢂꢆ  
1ꢆꢂ5  
1ꢄꢂꢅ  
1ꢊ ꢆiꢇꢁ  
ꢍ cꢎt  
1ꢊ ꢆiꢇꢁ  
ꢍ cꢎt  
ꢌ1ꢀꢍ1  
ꢌ1ꢀꢍ1  
ꢆꢂ5  
1ꢎ ꢇiꢈꢂ  
ꢏ cꢐt  
1ꢎ ꢇiꢈꢂ  
ꢏ cꢐt  
ꢆꢂ5  
ꢀꢁꢂꢃ  
ꢄꢅ  
ꢃꢄꢁꢄ  
5
1ꢂꢁꢃ  
5
1ꢂꢁꢃ  
1ꢃꢂ5  
15ꢂꢎ  
1ꢅꢁ5  
15ꢁꢊ  
ꢀꢃ  
ꢅꢅ  
ꢄꢅ  
ꢃꢃ  
Note: ON-OFF type does not have terminal No. 2 and 5.  
■Wire leads type  
External dimensions  
CAD Data  
1-ꢎꢏꢐe  
ꢀꢁꢂ  
ꢊ-ꢎꢏꢐe  
ꢀꢁꢂ  
ꢃꢅꢂ  
ꢃꢄꢂ  
1ꢄ ꢇiꢈꢆ  
ꢛ1ꢊꢜ1  
1ꢄ ꢇiꢈꢆ  
1ꢍꢆ5  
1ꢍꢆ5  
ꢛ1ꢊꢜ1  
ꢋ cꢌt  
ꢋ cꢌt  
ꢍꢆ5  
ꢍꢆ5  
1ꢁꢆꢀ  
1ꢁꢆꢀ  
ꢀꢀꢆꢊ  
ꢀꢉꢆꢅ  
ꢑꢏꢐꢏr ꢏꢒ wire ꢐeꢈꢇs  
ꢃꢊꢁ  
ꢃꢊꢁ  
ꢊꢁꢁ  
ꢓꢏꢆ  
1
ꢑꢏꢐꢏr  
ꢊꢁꢁ  
ꢃꢅ  
1ꢁ  
ꢔrꢏwꢕ  
ꢖeꢇ  
ꢃꢅ  
1ꢁ  
ꢗrꢈꢕꢘe  
ꢙeꢐꢐꢏw  
ꢚreeꢕ  
ꢔꢐꢌe  
5
1
15ꢆꢄ  
1
Notes: 1. ON-OFF type does not have wire lead  
No. 2 and 5.  
ꢊ1ꢆ1  
5
2. 300 V vinyl wire (VSF, thick: 2 mm2,  
length: 200 mm) is used.  
ꢀꢁꢆꢉ  
ꢀꢀ  
Panasonic Corporation Electromechanical Control Business Division  
© Panasonic Corporation 2019  
AECTB5E 201906  
industrial.panasonic.com/ac/e/  
ー 11 ー  
T-15 Series Switches  
(Unit: mm) General tolerance: ±0.5  
ROCKER TYPE DIMENSIONS  
■Standard type  
External dimensions  
2) Screw terminal (M3.5)  
1) Solder terminal  
1-ꢊꢋꢌe  
ꢀ-ꢊꢋꢌe  
CAD Data  
1-ꢊꢋꢌe  
ꢀ-ꢊꢋꢌe  
ꢀ-ꢍꢁꢎꢇꢃ5  
ꢀ-ꢍꢁꢎꢇꢃ5  
ꢀ-ꢍꢁꢎꢉꢄ5  
ꢀ-ꢍꢁꢎꢉꢄ5  
ꢆ5  
ꢁꢄ  
ꢀꢈ  
ꢆ5  
ꢁꢄ  
ꢀꢈ  
ꢇ5  
ꢁꢅ  
ꢀꢈ  
ꢇ5  
ꢁꢅ  
ꢀꢈ  
1ꢇꢃꢀ  
5ꢃꢈ  
1ꢇꢃꢀ  
5ꢃꢈ  
1ꢉꢄꢀ  
5ꢄꢈ  
1ꢉꢄꢀ  
5ꢄꢈ  
ꢁꢁꢄꢅ  
ꢁꢈꢃ1  
ꢁꢈ  
ꢆꢇꢃꢁ  
ꢂꢃꢁ  
ꢂꢃꢁ  
15ꢃꢄ  
1ꢂꢃ5  
15ꢄꢅ  
1ꢂꢄ5  
ꢀꢂ  
ꢀꢂ  
ꢁꢁ  
ꢁꢁ  
Notes: 1. ON-OFF type does not have terminal No. 2 and 5.  
2. Dimensions of actuator: 13.4 × 27  
■Panel-sealed type  
External dimensions  
1) Solder terminal  
2) Screw terminal (M3.5)  
CAD Data  
1-ꢈꢉꢊe  
ꢂ1  
ꢁ-ꢈꢉꢊe  
ꢂ1  
1-ꢅꢆꢇe  
ꢂ1  
ꢃ-ꢅꢆꢇe  
ꢂ1  
ꢆꢄꢇ  
ꢆꢄꢇ  
ꢁꢄ5  
ꢈꢉꢊ  
ꢈꢉꢊ  
ꢁꢄ5  
ꢁꢆꢄꢆ  
ꢃꢉ5  
ꢃꢉ5  
ꢀꢃꢄꢋ  
ꢃꢈꢉꢈ  
ꢀꢋꢉꢌ  
1ꢃꢄꢀ  
5
5
1ꢃꢄꢀ  
ꢀꢂ  
ꢀꢂ  
ꢀꢂ  
ꢀꢂ  
1ꢆ ꢁꢂ  
ꢁꢁ ꢁꢋ  
1ꢈ ꢃꢂ  
ꢃꢃ ꢃꢌ  
Notes: 1. ON-OFF type does not have terminal No. 2 and 5.  
2. Dimensions of actuator: 1-pole: 12.6 × 29, 2-pole: 17.4 × 29  
■Terminal-sealed type  
External dimensions  
1) Solder terminal  
2) Screw terminal (M3.5)  
CAD Data  
1-ꢉꢊꢋe  
ꢁ-ꢉꢊꢋe  
1-ꢉꢊꢋe  
ꢀ-ꢉꢊꢋe  
ꢁ1  
ꢂ1  
ꢂ1  
ꢁ1  
ꢀꢄꢈ  
ꢀꢄꢈ  
ꢁꢄ5  
ꢂꢅꢆ  
ꢂꢅꢆ  
ꢁꢄ5  
ꢁꢀꢄꢀ  
ꢀꢅ5  
ꢀꢅ5  
ꢀꢂꢅꢂ  
ꢅꢃꢄꢆ  
ꢃꢌꢅꢇ  
5
5
1ꢃꢄꢅ  
1ꢃꢄꢅ  
ꢃꢁ  
ꢃꢁ  
ꢅꢂ  
ꢅꢂ  
ꢀꢁ  
ꢇ  
1ꢀ ꢁꢂ  
ꢁꢁ ꢁꢆ  
1ꢂ  
Notes: 1. ON-OFF type does not have terminal No. 2 and 5.  
2. Dimensions of actuator: 1-pole: 12.6 × 29, 2-pole: 17.4 × 29  
Panasonic Corporation Electromechanical Control Business Division  
© Panasonic Corporation 2019  
AECTB5E 201906  
industrial.panasonic.com/ac/e/  
ー 12 ー  
T-15 Series Switches  
■Wire leads type  
External dimensions  
CAD Data  
1-ꢋꢌꢍe  
ꢂ-ꢋꢌꢍe  
ꢅ1  
ꢅ1  
ꢆꢈꢉ  
ꢆꢈꢉ  
ꢂꢈ5  
ꢂꢈ5  
ꢅꢂꢈꢂ  
ꢅ5ꢈꢅ  
ꢎꢌꢍꢌr ꢌꢏ wire ꢍeꢐꢑs  
ꢄꢂꢃ  
ꢂꢃꢃ  
ꢄꢂꢃ  
ꢂꢃꢃ  
ꢄꢅ  
ꢒꢌꢈ  
1
ꢎꢌꢍꢌr  
ꢓrꢌwꢔ  
ꢕeꢑ  
1ꢃ  
ꢄꢅ  
1ꢃ  
ꢀꢅ  
ꢀꢅ  
Notes: 1. ON-OFF type does not have terminal  
No. 2 and 5.  
ꢖrꢐꢔꢗe  
ꢘeꢍꢍꢌw  
ꢙreeꢔ  
ꢓꢍꢚe  
2. Dimensions of actuator: 1-pole: 12.6 ×  
29, 2-pole: 17.4 × 29  
3. 300 V vinyl wire (VSF, thick: 2 mm2,  
length: 200 mm) is used.  
5
1
1
1ꢅ  
ꢂꢂ  
ꢂꢊ  
5
(Unit: mm) General tolerance: ±0.5  
PUSH-BUTTON TYPE DIMENSIONS  
■Standard type  
External dimensions  
• Solder terminal, Momentary  
• Solder terminal, Alternate  
• Screw terminal (M3.5)  
Dimensions other than listed below are  
same as those of solder terminal type.  
1-ꢎꢏꢐe  
1ꢀꢃꢁ ꢍiꢊꢃ  
ꢁ-ꢎꢏꢐe  
1-ꢎꢏꢐe  
1ꢄꢅꢁ ꢍiꢊꢅ  
ꢁ-ꢎꢏꢐe  
1ꢄꢅꢁ ꢍiꢊꢅ  
1ꢀꢃꢁ ꢍiꢊꢃ  
1-ꢇꢈꢉe  
ꢀ-ꢇꢈꢉe  
ꢋ1ꢁꢌ1  
ꢀ1ꢁꢂ1  
ꢀ1ꢁꢂ1  
ꢋ1ꢁꢌ1  
1ꢌꢅ1  
1ꢌꢅ1  
15ꢃꢂ  
1ꢆ  
5ꢅꢃ  
ꢆꢃꢇ  
ꢂꢃꢁ  
ꢂꢃꢁ  
ꢈeꢉwꢊꢉ  
ꢈeꢉwꢊꢉ  
ꢈeꢉwꢊꢉ  
ꢈeꢉwꢊꢉ  
1ꢇꢃꢀ  
ꢁꢀꢃꢇ  
ꢆꢃꢇ  
5ꢅꢃ  
1ꢋ  
1ꢋ  
ꢁꢅꢃꢂ  
ꢄꢁꢅꢄ  
ꢄꢁꢅꢋ  
15ꢃꢄ  
1ꢂꢃ5  
ꢀꢂ  
ꢁꢁ  
15ꢃꢄ  
1ꢂꢃ5  
15ꢅꢆ  
1ꢃꢅ5  
ꢁꢃ  
ꢁꢂ  
ꢀꢀ  
ꢄꢄ  
■Panel-sealed type  
External dimensions  
• Solder terminal, Alternate  
• Solder terminal, Momentary  
• Screw terminal (M3.5)  
Dimensions other than listed below are  
same as those of solder terminal type.  
1-ꢎꢏꢐe  
1ꢀꢃꢁ ꢊiꢋꢃ  
ꢁ-ꢎꢏꢐe  
1ꢀꢃꢁ ꢊiꢋꢃ  
1-ꢎꢏꢐe  
1ꢂꢃꢀ ꢊiꢋꢃ  
ꢀ-ꢎꢏꢐe  
1ꢂꢃꢀ ꢊiꢋꢃ  
1-ꢇꢈꢉe  
ꢀ-ꢇꢈꢉe  
ꢌ1ꢁꢍ1  
ꢌ1ꢁꢍ1  
15ꢃꢂ  
ꢌ1ꢀꢍ1  
ꢌ1ꢀꢍ1  
15ꢃꢁ  
15ꢃꢂ  
15ꢃꢁ  
ꢆꢃꢀ  
ꢇꢃ5  
ꢆꢃꢀ  
ꢇꢃ5  
ꢆꢃꢂ  
ꢉꢃ5  
ꢆꢃꢂ  
ꢉꢃ5  
ꢈ cꢉt  
ꢈ cꢉt  
ꢇ cꢈt  
ꢇ cꢈt  
ꢂꢃꢁ  
ꢂꢃꢁ  
1ꢆꢃꢆ  
ꢁꢅꢃꢂ  
1ꢆꢃꢆ  
1ꢆꢃꢆ  
ꢂꢀꢃꢆ  
1ꢇꢃꢇ  
ꢁꢀꢃꢇ  
ꢂꢀꢃꢂ  
15ꢃꢄ  
1ꢂꢃ5  
ꢀꢂ  
ꢁꢁ  
15ꢃꢄ  
1ꢂꢃ5  
15ꢃꢄ  
1ꢁꢃ5  
ꢀꢁ  
ꢁꢂ  
ꢀꢀ  
ꢂꢂ  
Panasonic Corporation Electromechanical Control Business Division  
© Panasonic Corporation 2019  
AECTB5E 201906  
industrial.panasonic.com/ac/e/  
ー 13 ー  
T-15 Series Switches  
MOUNTING DIMENSIONS  
■Toggle type  
Type  
Standard type  
ꢀrꢁꢂt heꢃ ꢂꢄt  
ꢅeꢆiꢂꢇ wꢈsher  
ꢉꢁcꢊ wꢈsher  
ꢋꢈcꢊ heꢃ ꢂꢄt  
1ꢀꢁꢂ ꢃiꢄꢁ  
1ꢀꢁ5 ꢂiꢃꢁ  
1ꢀꢁ5 ꢂiꢃꢁ  
Panel cutout  
(Unit: mm)  
11ꢁ5  
ꢅꢁꢀ±ꢆꢁ1  
1ꢁ5  
±ꢆꢁꢀꢂiꢃꢁ  
Max. 5.6 mm  
(without keying washer)  
Max. 5.6 mm  
(without keying washer)  
Panel thickness  
Type  
Max. 4.6 mm  
Panel-sealed, Terminal-sealed and Wire leads types  
1ꢀꢁ5 ꢂiꢃꢁ  
1ꢀꢁ5 ꢂiꢃꢁ  
Panel cutout  
(Unit: mm)  
11ꢁꢀ  
Max. 4 mm  
Max. 4 mm  
Panel thickness  
(without keying washer)  
Note: For panel installations of standard type, be use to use the back hex nut.  
■Rocker type  
Type  
Standard type  
Panel-sealed, Terminal-sealed and Wire leads types  
1ꢈꢂ5ꢇꢃꢂꢁ  
1 ꢀꢁꢂe  
ꢃ-ꢀꢁꢂe  
Panel cutout  
(Unit: mm)  
ꢁꢆ±ꢃꢂꢁ  
ꢀꢆꢇꢃꢂꢁ  
ꢄꢅꢆꢃ±ꢇꢆ1  
ꢄꢅꢆꢃ±ꢇꢆ1  
1ꢈꢆꢃ±ꢇꢆ1  
ꢃꢃꢆꢃ±ꢇꢆ1  
ꢀ-ꢁꢂ5±ꢃꢂ1ꢄiꢅꢂ  
Panel thickness  
Max. 4.5 mm  
Standard type  
1.2 to 3.2 mm  
■Push-button type  
Type  
Panel-sealed type  
1ꢀꢁ5 ꢂiꢃꢁ  
1ꢀꢁꢂ ꢃiꢄꢁ  
1ꢀꢁ5 ꢂiꢃꢁ  
1ꢀꢁ5 ꢂiꢃꢁ  
1ꢀꢁ5 ꢂiꢃꢁ  
Panel cutout  
(Unit: mm)  
11ꢁ5  
11ꢁꢀ  
ꢅꢁꢀ±ꢆꢁ1  
1ꢁ5  
ꢄ ꢂiꢃꢁ  
Momentary, 1-pole:  
Momentary, 1-pole:  
Max. 10 mm Momentary,  
2-pole: Max. 7.5 mm  
Alternate: Max. 7.5 mm  
(without keying washer)  
Momentary, 1-pole:  
Max. 11 mm Momentary,  
2-pole: Max. 7.5 mm  
Alternate: Max. 7.5 mm  
(without keying washer)  
Max. 10 mm  
Momentary, 2-pole:  
Max. 6.5 mm  
Max. 4 mm  
(without keying washer)  
Panel thickness  
Max. 4 mm  
Alternate: Max. 6.5 mm  
Note: For panel installations of standard type, be use to use the back hex nut.  
Panasonic Corporation Electromechanical Control Business Division  
© Panasonic Corporation 2019  
AECTB5E 201906  
industrial.panasonic.com/ac/e/  
ー 14 ー  
T-15 Series Switches  
TERMINAL CIRCUIT DIAGRAM  
■Toggle type and Rocker type  
Number of pole  
Toggle type  
1-pole  
2-pole  
3-pole  
Available *3  
4-pole  
Available *3  
Available  
Available  
Available  
Available  
Rocker type  
Terminal arrangement  
(As seen from terminal side)  
ꢀeꢁwꢂꢁ  
ꢀeꢁwꢂꢁ  
ꢀeꢁwꢂꢁ  
ꢀeꢁwꢂꢁ  
Actuator shape  
Toggle type  
Rocker type  
ꢀiꢁht  
ꢂꢃrt ꢄꢅꢆ  
1-3  
1-3, 4-6  
1-3, 4-6, 7-9  
1-3, 4-6, 7-9, 10-12  
ꢀeꢁwꢂꢁ  
ON-OFF  
Left  
ꢀeꢁwꢂꢁ  
ꢀiꢁht  
ꢂꢃrt ꢄꢅꢆ  
2-3  
2-3, 5-6  
2-3, 5-6, 8-9  
2-3, 5-6, 8-9, 11-12  
ꢀeꢁwꢂꢁ  
ON-ON  
ON-<ON>  
*1  
ꢀeꢁt  
ꢂꢃ  
1-2  
2-3  
1-2, 4-5  
2-3, 5-6  
1-2, 4-5, 7-8  
2-3, 5-6, 8-9  
1-2, 4-5, 7-8, 10-11  
2-3, 5-6, 8-9, 11-12  
ꢀeꢁwꢂꢁ  
ꢀiꢁht  
ꢂꢃrt ꢄꢅꢆ  
ꢀeꢁwꢂꢁ  
ON-OFF-ON  
<ON>-OFF-<ON>  
ON-OFF-<ON>  
*1  
ꢀeꢁter  
ꢀeꢁwꢂꢁ  
ꢀeꢁt  
ꢂꢃ  
1-2  
1-2, 4-5, 7-8  
1-2, 4-5, 7-8, 10-11  
ꢀeꢁwꢂꢁ  
1-2, 4-5  
ON-OFF type does  
not have a terminal  
No. 2.  
ON-OFF type does  
not have terminal  
No. 2 and 5.  
ON-OFF type does  
not have terminal  
No. 2, 5 and 8.  
ON-OFF type does  
not have terminal  
No. 2, 5, 8 and 11.  
Remarks  
Notes: *1. For ON-<ON>, ON-OFF-<ON> type of toggle, if the lever turns to the keyway side, it takes momentary position.  
*2. For the rocker type, if the actuator turns to the left side in view of the side where a part number is marked, it takes momentary position.  
*3. Only standard type  
■Push-button type  
1-pole  
2-pole  
Terminal arrangement  
(As seen from terminal side)  
ꢀeꢁwꢂꢁ  
ꢀeꢁwꢂꢁ  
2-3  
1-2  
2-3, 5-6  
1-2, 4-5  
Push-button position  
and contact terminal number  
ꢀꢁerꢂteꢃ  
Panasonic Corporation Electromechanical Control Business Division  
© Panasonic Corporation 2019  
AECTB5E 201906  
industrial.panasonic.com/ac/e/  
ー 15 ー  
T-15 Series Switches  
CAUTIONS FOR USE  
3) Rubber cap installation  
a. The washer should be used on the back side of the panel.  
■Dustproof, waterproof, anticorrosive gas, and oil-proof  
designs  
The panel-sealed type/terminal-sealed type/wire lead type  
switch has a protection level of IP67 or IP64 on the outer side of  
the mounting panel and a level of IP40, IP60, or IP67 on the  
inner side of the panel. For actual application, note the following  
points:  
1) Avoid immersion in water or oil during installation.  
2) Avoid immersion in water or oil during operation.  
3) Oils or gases impose varying degrees of impact on the  
switch’s sealing performance depending on type or quantity.  
4) While the switch has a immersion and dust-protected design,  
its sealing performance or operabillity may be adversely affected  
in an environment where in the switch's movable parts can be  
contaminated with dust, oil, or other foreign objects. For the  
toggle type, use of a rubber cap is recommended.  
5) The standard toggle switch, when used with a rubber cap,  
provides a protection level of IP54.  
ꢀꢁꢂ tꢃ ꢀꢁ5 ꢄꢄ  
ꢅꢆsher  
b. Enough screw pitch should be obtained being adjusted within  
3 to 3.5mm.  
c. After first installing the rubber cap, please tighten to 1.96 Nm  
or less with a hexagonal nut.  
d. The mounting hole in the panel should preferably be provided  
with an anti-rotation projection.  
It should be used in an environment where it will not be subject  
to frequent water splashes.  
6) As the sealing performance of the rocker type switch is  
affected by the panel processing accuracy or mounted panel  
thickness, check the switch under actual loading conditions.  
(While water or dust will not enter the switch’s internal structure,  
it may enter the panel.)  
ꢀꢁꢂꢃtiꢃꢄ hꢁꢅe  
e. If the rubber cap is installed over the hex nut, the waterproof  
performance will be impaired although the dustproof  
performance will not be affected.  
7) Do not operate the rocker type switch when water  
accumulates in the actuator.  
■Snap switch water resistance performance  
Panel front  
Panel interior  
Push-  
button  
type  
Push-  
button  
type  
Toggle Rocker  
Toggle Rocker  
type  
type  
type  
type  
ꢀeꢁꢂꢃꢄꢅꢂꢆ ꢅꢇt  
Standard type +  
Rubber cap  
IP54  
IP40  
Panel-sealed type  
Terminal-sealed type  
Wire leads type  
IP67  
IP67  
IP67  
IP64  
IP64  
IP64  
IP67  
IP40  
IP60  
IP67  
IP40  
IP60  
IP67  
IP40  
■Soldering  
Perform soldering in less than 3 seconds with maximum 350°C  
iron. Care should be taken not to apply force to the terminals  
during soldering. We recommend a soldering iron with  
temperature adjustment in order to prevent poor quality  
soldering.  
■Installation  
1) For the toggle and push-button type  
a. When installing the standard type switch, be sure to use a hex  
nut.  
Please consult us if you intend to use a soldering iron of 60 W or  
higher.  
b. For the panel-sealed, terminal-sealed and wire lead types,  
use a lock washer on the front side of the panel, and an O-ring  
on the back side of it.  
c. Do not install the switch by rotating it.  
2) For the rocker type  
a. In case the panel-sealed, terminal-sealed or wire leads types  
are used in the condition where the water splash on, please in  
the case of vertical installation, please install the switches tilt  
more than 25° or in the case of horizontal installation, please  
install the switches tilt more than 50°. (90° recommended)  
■Load type and ratings  
1) When the switch is loaded with a lamp, motor or capacitive  
load, a surge current higher than the stationary current passes  
through the switch contacts.  
Measure the surge with the actual load and, if needed, take  
necessory action so that the surge will not exceed the switch’s  
rated current.  
2) When the switch is loaded with an inductive load (relay,  
solenoid, buzzer, etc.), a contact failure may result from arc  
discharge caused by a counterelectromotive force. It is advisable  
that you use an adequate anti-spark circuit across the switch  
contacts.  
ꢉꢅꢎꢄtiꢄꢏ ꢐꢂꢄeꢃ  
ꢉiꢄꢊ ꢍ5ꢌ  
■Others  
1) Do not apply an excessive static load exceeding 112.7N  
perpendicular to the direction of operation.  
2) Operate the switch actuator by hand.  
3) Take care not to drop the product as it may impair  
performance.  
4) These switches are only for Industrial use.  
Do not use any other applications. (ex. home use)  
ꢀꢁerticꢂꢃ iꢄstꢂꢃꢃꢂtiꢅꢄꢆ  
ꢀꢇꢅriꢈꢅꢄtꢂꢃ iꢄstꢂꢃꢃꢂtiꢅꢄꢆ  
b. In case water inside the switch case may freeze, please install  
the switch vertically to avoid the water remain inside the switch.  
Panasonic Corporation Electromechanical Control Business Division  
© Panasonic Corporation 2019  
AECTB5E 201906  
industrial.panasonic.com/ac/e/  
ー 16 ー  
T-15 Series Switches  
REFERENCE  
■Dust-protected type  
• Level of protection indicated by the 1st Characteristics number  
This type of construction prevents dust that is large enough to  
have an effect on operation from getting inside the unit. This  
construction is stipulated by protective classes against solid  
matter in the IEC standards (IEC60529).  
The talcum powder used shall be able to pass through a  
squaremeshed sieve the nominal wire diameter of 75 μm. The  
amount of talcum powder to be used is 2 kg per cubic metre of  
the test chamber volume. The duration of the test is 8 hours.  
No damage observed after the test.  
1st Characteristics  
Protection level (IEC60529/Solid matter)  
number  
0
1
2
3
4
No protection  
Protected against solid matter larger than 50mm  
Protected against solid matter larger than 12mm  
Protected against solid matter larger than 2.5mm  
Protected against solid matter larger than 1.0mm  
Dust-protected type  
Prevents dust that is large enough to have an effect  
on operation from getting inside the unit  
5
6
Dust-resistant type  
Prevents dust from getting inside the unit  
■Immersion-protected type  
• Level of protection indicated by the 2nd Characteristics number  
This type of construction prevents any harmful effects even after  
the device is left underwater at a depth of 1 m for 30 minutes.  
This construction is stipulated by protective classes against  
water in the IEC standards (IEC60529).  
2nd  
JIS C0920  
Characteristics Protection level (IEC60529/Liquid matter)  
number  
0
No protection  
Droplet-protected  
type I  
Protected against water droplets that fall  
perpendicular to the unit  
1
■IEC’s IP Codes  
Droplet-protected  
type II  
Protected against water droplets that fall  
from within 15° of perpendicular to the unit  
2
3
4
5
6
The IEC (International Electrotechnical Commission) has  
defined the IP characteristic code that represents the levels of  
protection described in IEC standard (IEC60529).  
The two numbers that follow the IP code (the characteristics  
numbers) indicate the suitability of this protection for all  
environmental conditions.  
Rain-protected  
type  
Protected against water droplets that fall  
from within 60° of perpendicular to the unit  
Splash-protected  
type  
Protected against water that splashes on  
the unit from any direction  
Spray-protected  
type  
Free from adverse effects even if sprayed  
directly with water from any direction  
Water-resistant  
type  
Protected against water sprayed directly  
on the unit from any direction  
ꢇꢈ  
Water does not get inside of the unit when  
submerged in water according to the  
specified conditions  
Immersion-  
protected type  
7
1st chꢀrꢀcteristics ꢁꢂꢃꢄer  
ꢅꢁꢆ chꢀrꢀcteristics ꢁꢂꢃꢄer  
Underwater type  
8
Unit can be used underwater  
Note: Details of test conditions are the same as NECA C 0920. Please refer to them.  
Panasonic Corporation Electromechanical Control Business Division  
© Panasonic Corporation 2019  
AECTB5E 201906  
industrial.panasonic.com/ac/e/  
ー 17 ー  
TechnicalTerminology & Cautions for Use  
(Operation Switches)  
TECHNICAL TERMINOLOGY  
Rated values  
Shock resistance  
Values indicating the characteristics and performance guarantee  
standards of the switches. The rated current and rated voltage,  
for instance, assume specific conditions.  
Max. shock value where a closed contact does not open for  
longer than a specified time due to shocks during use of the  
switches.  
Electrical life  
Allowable switching frequency  
The service life when the rated load is connected to the contact  
This is the maximum switching frequency required to reach the  
and switching operations are performed.  
end of mechanical life (or electrical life).  
Mechanical life  
Temperature rise value  
The service life when operated at a preset operating frequency  
without passing electricity through the contacts.  
This is the maximum temperature rise value that heats the  
terminal portion when the rated current is flowing through the  
contacts.  
Dielectric strength  
Threshold limit value that a high voltage can be applied to a  
predetermined measuring location for one minute without  
causing damage to the insulation.  
Actuator strength  
When applying a static load for a certain period on the actuator  
in the operation direction, this is the maximum load it can  
withstand before the switch loses functionality.  
Insulation resistance  
This is the resistance value at the same place the dielectric  
Terminal strength  
strength is measured.  
When applying a static load for a certain period (in all directions  
if not stipulated) on a terminal, this is the maximum load it can  
withstand before the terminal loses functionality (except when  
the terminal is deformed).  
Contact resistance  
This indicates the electrical resistance at the contact part.  
Generally, this resistance includes the conductor resistance of  
the spring and terminal portions.  
Vibration resistance  
Vibration range where a closed contact does not open for longer  
than a specified time due to vibrations during use of the snap-  
action switches.  
AECTB38E 201811-T  
ー 18 ー  
Technical Terminology & Cautions for Use  
TYPES OF LOAD  
Resistance load  
Motor load  
Resistance load is a power factor of 1 (cosφ = 1) where the load  
is only for the resistance portion. The displayed switch rating  
indicates the current capacity when using AC current.  
Contacts may adhere due to the starting current at the start of  
motor operation which is three to eight times the steady-state  
current. Although it differs depending on the motor, since a  
current flows that is several times that of the nominal current,  
please select a switch taking into consideration the values in the  
table below. To make the motor rotate in reverse, use an ON-  
OFF-ON switch and take measures to prevent a multiplier  
current (starting current + reverse current) from flowing.  
DC load  
Differing from AC, since the direction of current is fixed for DC,  
the continuous arc time lengthens when the same voltage is  
applied.  
Motor type  
Type  
Starting current  
Incandescent lamp load  
Three-phase  
induction motor  
Approx. 5 to 8 times current listed on  
nameplate  
Squirrel-cage  
Since an inrush current of 10 to 15 times the rated current flows  
for an instant when the switch is turned on for the lamp,  
adhesion of the contacts may occur. Therefore, please take into  
consideration this transient current when selecting a switch.  
Approx. 6 times current listed on  
nameplate  
Split-phase-start  
Capacitor-start  
Repulsion-start  
Single-phase  
induction motor  
Approx. 4 to 5 times current listed on  
nameplate  
Approx. 3 times current listed on  
nameplate  
Induction load  
Since arc generation due to reverse voltage can cause contact  
failure to occur when there is an induction load (in relays,  
solenoids and buzzers, etc.), we recommend you insert a  
suitable spark quenching circuit (see figure below).  
A current that is approximately two times that of the starting  
current will flow when reverse rotation is caused during  
operation. Also, when using for a load that will cause transient  
phenomena such as when operating the motor in reverse  
rotation or switching the poles, an arc short (circuit short) may  
occur due to the time lag between poles when switching. Please  
be careful.  
Circuit example  
Notes  
Switch contact  
(1) r = more than 10 Ω  
(2) In an AC circuit,  
Example of 1-pole motor reverse rotation circuit  
r
c
R
R
R
impedance of R is to be slightly smaller  
than impedance of r and c.  
Power  
supply  
M
M
Switch contact  
Power  
supply  
Can be used for both AC and DC circuits.  
r = R  
C: 0.1 μF  
r
c
Good wiring  
Bad wiring  
Example of single-phase induction motor  
(capacitor) strong-weak switching circuit  
Switch contact  
diode  
Strong  
Strong  
Weak  
Strong  
M
For DC circuits only.  
Weak  
M
Weak  
Strong  
Power  
supply  
Switch contact  
Good wiring  
Bad wiring  
Example of three-phase motor  
ZNR  
Varistor  
Can be used for both AC and DC circuits.  
reverse rotation circuit  
Power  
supply  
M
Power  
supply  
M
Good wiring  
Bad wiring  
Capacitor load  
In the case of mercury lamps, florescent lamps and the  
capacitor loads of capacitor circuits, since an extremely large  
inrush current flows when the switch is turned on, please  
measure that transient value with the actual load and then either  
use the product keeping within the range of the rated current or  
after verifying the actual load.  
AECTB38E 201811-T  
ー 19 ー  
Technical Terminology & Cautions for Use  
CAUTIONS FOR USE  
Environment of use  
Wiring  
1) Please consult us when using under the following conditions:  
• Environments where hydrogen sulfide or other corrosive gases  
are present.  
1) When using a PC board terminal switch as soldering  
terminals, use thin lead wires and be sure to wind them on the  
terminals before soldering.  
• Environments where gasoline, thinner or other flammable,  
explosive gases are present.  
• Dusty environments (for non-seal type snap action switches).  
• Use in environments not in the prescribed temperature or  
humidity range.  
2) Cautions when soldering  
Perform soldering quickly in accordance with the specified  
conditions. Be careful not to let flux flow into the product. When  
no instruction is specified, use a soldering iron with a tip  
temperature of 350°C or lower and complete soldering within  
five seconds. Do not pull on the lead wires immediately after  
soldering. Wait some time before verifying.  
• Places with low air pressure.  
2) Unless specified the product will not be constructed to  
withstand water, oil or explosions. Please inquire if you intend to  
use the product in special applications.  
Others  
Usage, storage, and transport conditions  
1) During usage, storage, or transportation, avoid locations  
subject to direct sunlight and maintain normal temperature,  
humidity, and pressure conditions.  
2) The allowable specifications for environments suitable for  
usage, storage, and transportation are given below.  
(1) Temperature: The allowable temperature range differs for  
each switch, so refer to the switch’s individual specifications.  
(2) Humidity: 5 to 85% R.H.  
1) Failure modes of switches include short-circuiting, open-  
circuiting and temperature rises. If this switch is to be used in  
equipment where safety is a prime consideration, examine the  
possible effects of these failures on the equipment concerned,  
and ensure safety by providing protection circuits or protection  
devices. In terms of the systems involved, make provision for  
redundancy in the design and take steps to achieve safety  
design.  
2) The ambient operating temperature (and humidity) range  
quoted is the range in which the switch can be operated on a  
continuous basis: it does not mean that using the switch within  
the rating guarantees the durability performance and  
environment withstanding performance of the switch. For details  
on the performance guarantee, check the specifications of each  
product concerned.  
(3) Pressure: 86 to 106 kPa  
The humidity range varies with the temperature. Use within the  
range indicated in the graph below.  
(The allowable temperature depends on the switch.)  
Humidity, %R.H.  
3) Even if 2-pole, 3-pole or 4-pole switches are used as single-  
pole switches in order to increase contact reliability, please keep  
the maximum current no higher than the rated value.  
4) If there is the possibility of a short between poles, please use  
an in-phase circuit as shown below or provide a spare pole.  
85  
Tolerance range  
(Avoid freezing when  
used at temperatures  
lower than 0°C 32°F)  
(Avoid  
condensation when  
used at temperatures  
higher than 0°C 32°F)  
Bad example  
Load 1  
5
–40  
0
+85  
–40  
+32  
+185  
Load 2  
Temperature, °C °F  
Heteropolar circuit  
• Condensation will occur inside the switch if there is a sudden  
change in ambient temperature when used in an atmosphere of  
high temperature and high humidity. This is particularly likely to  
happen when being transported by ship, so please be careful of  
the atmosphere when shipping. Condensation is the  
phenomenon whereby steam condenses to cause water  
droplets that adhere to the switch when an atmosphere of high  
temperature and humidity rapidly changes from a high to low  
temperature or when the switch is quickly moved from a low  
humidity location to one of high temperature and humidity.  
Please be careful because condensation can cause adverse  
conditions such as deterioration of insulation, coil cutoff, and  
rust.  
Good example (1)  
Load 1  
Load 2  
In-phase circuit  
Good example (2)  
Load 1  
Spare pole  
Load 2  
• Condensation or other moisture may freeze on the switch when  
the temperatures is lower than 0°C 32°F. This causes problems  
such as sticking of movable parts or operational time lags.  
• The plastic becomes brittle if the switch is exposed to a low  
temperature, low humidity environment for long periods of time.  
• Storage for extended periods of time (including transportation  
periods) at high temperatures or high humidity levels or in  
atmospheres with organic gases or sulfide gases may cause a  
sulfide film or oxide film to form on the surfaces of the contacts  
and/or it may interfere with the functions. Check out the  
atmosphere in which the units are to be stored and transported.  
• In terms of the packing format used, make every effort to keep  
the effects of moisture, organic gases and sulfide gases to the  
absolute minimum.  
5) Be careful not to drop the product as this may cause loss of  
functionality.  
6) Do not apply an unreasonable vertical force against the  
direction of operation of the product.  
7) Use your hand to operate the actuator.  
(Operation using a tool such as a screwdriver or hammer can  
cause breakdown.)  
AECTB38E 201811-T  
ー 20 ー  
20  
9
1
AECTB5E 201906  

相关型号:

UL1042

UL1042 - Uk砤d zr體nowa縪nego mieszacza iloczynowego

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

ZXFV201

QUAD VIDEO AMPLIFIER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX

ZXFV201N14

IC-SM-VIDEO AMP

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX

ZXFV201N14TA

QUAD VIDEO AMPLIFIER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX

ZXFV201N14TC

QUAD VIDEO AMPLIFIER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

ZXFV302N16

IC-SM-4:1 MUX SWITCH

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

ZXFV4089

VIDEO AMPLIFIER WITH DC RESTORATION

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX