V10271U [PANASONIC]

ZNR Transient/Surge Absorbers (Type D);
V10271U
型号: V10271U
厂家: PANASONIC    PANASONIC
描述:

ZNR Transient/Surge Absorbers (Type D)

文件: 总20页 (文件大小:404K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
“ZNR” Transient/Surge Absorbers (Type D)  
ZNRTransient/Surge Absorbers  
Type:  
D
V
Series:  
Features  
Recommended Applications  
Transistor, diode, IC, thyristor or triac semiconductor  
Large withstanding surge current capability in compact  
sizes  
protection  
Large Energy Handling Capability absorbing transient  
overvoltages in compact sizes  
Surge protection in consumer electronic equipment  
Surge protection in communication, measuring or  
controller electronics  
Surge protection in electronic home appliances, gas or  
petroleum appliances  
Wide range of varistor voltages  
RoHS compliant  
Applicable Standards  
Handling Precautions and Minimum Quantity /  
Packing Unit  
UL1449 (VZCA2/UL, VZCA8/C-UL)  
VDE IEC61051-1, -2, -2-2, IEC60950-1 Annex.Q  
CSA C22.2 No.1  
Please see Related Information  
CQC(GB/T10193, GB/T10194, GB4943.1, GB8898)  
Refer to page 5 to 8, and 27, for the details  
Explanation of Part Numbers (Bulk)  
1
2
3
4
5
6
7
8
9
10  
11  
12  
&
3
;
7
%
Product Code  
Series  
Design No.  
Element Size  
Lead Configuration  
Norminal Varistor Voltage  
f
f
f
f
f
05  
07  
09  
5 mm  
7 mm  
10  
14  
20  
10 mm  
14 mm  
20 mm  
D
V
Straight Lead  
Crimped Lead  
The first two digits are significant  
figures and the third one denotes  
the number of zeros following.  
=
= Excluding f20.  
f
10 mm  
= Only the lead cut  
Explanation of Part Numbers (Taping)  
1
2
3
4
5
6
7
8
9
10  
11  
12  
&
3
;
7
%
Product Code  
Series  
Design No.  
Taping / Packaging  
Element Size  
Lead Configuration  
Nominal Varistor Voltage  
f
f
A to D Radial Taping (P0=12.7 mm)  
E to H Radial Taping (P0=15.0 mm)  
5
7
9
A
E
5 mm  
7 mm  
D
V
Straight Lead  
Crimped Lead  
The first two digits are significant  
figures and the third one denotes  
the number of zeros following.  
f
f
f
10 mm  
10 mm  
14 mm  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
02 Aug. 2013  
– 4 –  
“ZNR” Transient/Surge Absorbers (Type D)  
Reference Guide to Standard Products  
Maximum  
Allowable  
Voltage  
Clamping  
Voltage  
at 8/20μs  
Maximum  
Peak Current  
at 8/20μs(A)  
Applicable  
Standards  
Varistor  
Voltage  
Part No.  
Recommended Applications  
Type Name Approvals  
(V)  
ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times  
ERZV05D180  
ERZV07D180  
ERZV09D180  
ERZV10D180  
ERZV14D180  
ERZV20D180  
ERZV05D220  
ERZV07D220  
ERZV09D220  
ERZV10D220  
ERZV14D220  
ERZV20D220  
ERZV05D270  
ERZV07D270  
ERZV09D270  
ERZV10D270  
ERZV14D270  
ERZV20D270  
ERZV05D330  
ERZV07D330  
ERZV09D330  
ERZV10D330  
ERZV14D330  
ERZV20D330  
ERZV05D390  
ERZV07D390  
ERZV09D390  
ERZV10D390  
ERZV14D390  
ERZV20D390  
ERZV05D470  
ERZV07D470  
ERZV09D470  
ERZV10D470  
ERZV14D470  
ERZV20D470  
ERZV05D560  
ERZV07D560  
ERZV09D560  
ERZV10D560  
ERZV14D560  
ERZV20D560  
ERZV05D680  
ERZV07D680  
ERZV09D680  
ERZV10D680  
ERZV14D680  
ERZV20D680  
V180  
V7180  
V9180  
V10180  
V14180  
V20180  
V220  
40  
36  
1
250  
500  
125  
250  
2.5  
5
36  
1000  
1000  
2000  
3000  
250  
500  
18  
11  
14  
17  
20  
25  
30  
35  
40  
14  
18  
22  
26  
31  
38  
45  
56  
(16 to 20)  
36  
5
500  
36  
10  
1000  
2000  
125  
36  
20  
1
48  
V7220  
V9220  
V10220  
V14220  
V20220  
V270  
43  
2.5  
500  
250  
43  
5
5
1000  
1000  
2000  
3000  
250  
500  
22  
(20 to 24)  
43  
500  
43  
10  
20  
1
1000  
2000  
125  
43  
60  
V7270  
V9270  
V10270  
V14270  
V20270  
V330  
53  
2.5  
500  
250  
53  
5
5
1000  
1000  
2000  
3000  
250  
500  
27  
(24 to 30)  
53  
500  
53  
10  
20  
1
1000  
2000  
125  
53  
73  
V7330  
V9330  
V10330  
V14330  
V20330  
V390  
65  
2.5  
500  
250  
65  
5
5
1000  
1000  
2000  
3000  
250  
500  
33  
(30 to 36)  
65  
500  
65  
10  
20  
1
1000  
2000  
125  
65  
For the low voltage circuit  
86  
V7390  
V9390  
V10390  
V14390  
V20390  
V470  
77  
2.5  
500  
250  
77  
5
5
1000  
1000  
2000  
3000  
250  
500  
39  
(35 to 43)  
77  
500  
77  
10  
20  
1
1000  
2000  
125  
77  
104  
93  
V7470  
V9470  
V10470  
V14470  
V20470  
V560  
2.5  
500  
250  
93  
5
5
1000  
1000  
2000  
3000  
250  
500  
47  
(42 to 52)  
93  
500  
93  
10  
20  
1
1000  
2000  
125  
93  
123  
110  
110  
110  
110  
110  
150  
135  
135  
135  
135  
135  
V7560  
V9560  
V10560  
V14560  
V20560  
V680  
2.5  
500  
250  
5
5
1000  
1000  
2000  
3000  
250  
500  
56  
(50 to 62)  
500  
10  
20  
1
1000  
2000  
125  
V7680  
V9680  
V10680  
V14680  
V20680  
2.5  
500  
250  
5
5
1000  
1000  
2000  
3000  
500  
68  
(61 to 75)  
500  
10  
20  
1000  
2000  
Measuring Current of Varistor Voltage 5 Series : 0.1 mA, Others: 1 mA  
: UL1449 (VZCA2/UL, VZCA8/C-UL),  
: UL1449 Type3 (or Code-Connected and Direct plug-in),  
: UL1449 Type2 (or Permanently Connected),  
: VDE (IEC61051-1, -2, -2-2),  
: VDE (IEC60950-1 Annex.Q), : CSA C22.2 No.1  
: CQC (GB/T10193, GB/T10194),  
: CQC (GB4943.1, GB8898)  
Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
02 Aug. 2013  
– 5 –  
“ZNR” Transient/Surge Absorbers (Type D)  
Reference Guide to Standard Products  
Maximum  
Allowable  
Voltage  
Clamping  
Voltage  
at 8/20μs  
Maximum  
Peak Current  
at 8/20μs(A)  
Applicable  
Standards  
Varistor  
Voltage  
Part No.  
Recommended Applications  
Type Name Approvals  
(V)  
ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times  
ERZV05D820  
V820U  
○☆◇  
○☆◇  
145  
135  
135  
135  
135  
135  
175  
165  
165  
165  
165  
165  
210  
200  
200  
200  
200  
200  
260  
250  
250  
250  
250  
250  
355  
340  
340  
340  
340  
340  
380  
360  
360  
360  
360  
360  
415  
395  
395  
395  
395  
395  
475  
455  
455  
455  
455  
455  
5
10  
25  
25  
50  
800  
600  
ERZV07D820 V7820U  
ERZV09D820 V9820U  
ERZV10D820 V10820U  
ERZV14D820 V14820U  
ERZV20D820 V20820U  
1750 1250  
3500 2500  
3500 2500  
6000 5000  
○☆◇  
82  
50  
60  
65  
(74 to 90)  
○☆◇  
○◎☆◇  
○◎☆◇  
○☆◇  
100 10000 7000  
ERZV05D101  
V101U  
5
10  
25  
25  
50  
800  
600  
ERZV07D101 V7101U  
ERZV09D101 V9101U  
ERZV10D101 V10101U  
ERZV14D101 V14101U  
ERZV20D101 V20101U  
○☆◇  
1750 1250  
3500 2500  
3500 2500  
6000 5000  
○☆◇  
100  
(90 to 110)  
85  
○☆◇  
○◎☆◇  
○◎☆◇  
○☆◇  
100 10000 7000  
Telephone, Communication Line  
(DC 48 V)  
600  
ERZV05D121  
V121U  
5
10  
25  
25  
50  
800  
ERZV07D121 V7121U  
ERZV09D121 V9121U  
ERZV10D121 V10121U  
ERZV14D121 V14121U  
ERZV20D121 V20121U  
○☆◇  
1750 1250  
3500 2500  
3500 2500  
6000 5000  
○☆◇  
120  
(108 to 132)  
75  
100  
125  
170  
180  
200  
225  
○☆◇  
○◎☆◇  
○◎☆◇  
○☆◇  
100 10000 7000  
ERZV05D151  
V151U  
5
10  
25  
25  
50  
800  
600  
ERZV07D151 V7151U  
ERZV09D151 V9151U  
ERZV10D151 V10151U  
ERZV14D151 V14151U  
ERZV20D151 V20151U  
○☆◇  
1750 1250  
3500 2500  
3500 2500  
6000 5000  
○☆◇  
150  
(135 to 165)  
95  
○☆◇  
○◎☆◇  
○◎☆◇  
100 10000 7000  
ERZV05D201  
V201U  
○☆  
○☆  
○☆  
○☆  
5
10  
25  
25  
50  
800  
600  
ERZV07D201 V7201U  
ERZV09D201 V9201U  
ERZV10D201 V10201U  
1750 1250  
3500 2500  
3500 2500  
6000 5000  
200  
(185 to 225)  
130  
140  
150  
175  
□◇◆  
□◇◆  
ERZV14D201 V14201U ○◎☆★  
ERZV20D201 V20201U ○◎☆★  
100 10000 7000  
AC 100 V Line–Line  
Applications  
600  
ERZV05D221  
V221U  
○☆  
○☆  
○☆  
○☆  
5
10  
25  
25  
50  
800  
ERZV07D221 V7221U  
ERZV09D221 V9221U  
ERZV10D221 V10221U  
1750 1250  
3500 2500  
3500 2500  
6000 5000  
220  
(198 to 242)  
□◇◆  
□◇◆  
ERZV14D221 V14221U ○◎☆★  
ERZV20D221 V20221U ○◎☆★  
100 10000 7000  
ERZV05D241  
V241U  
○☆  
○☆  
○☆  
○☆  
5
10  
25  
25  
50  
800  
600  
ERZV07D241 V7241U  
ERZV09D241 V9241U  
ERZV10D241 V10241U  
1750 1250  
3500 2500  
3500 2500  
6000 5000  
240  
(216 to 264)  
□◇◆  
□◇◆  
ERZV14D241 V14241U ○◎☆★  
ERZV20D241 V20241U ○◎☆★  
100 10000 7000  
AC 100 V to 120 V, Line–Line  
Applications  
600  
ERZV05D271  
V271U  
○☆  
○☆  
○☆  
○☆  
5
10  
25  
25  
50  
800  
ERZV07D271 V7271U  
ERZV09D271 V9271U  
ERZV10D271 V10271U  
1750 1250  
3500 2500  
3500 2500  
6000 5000  
270  
(247 to 303)  
□◇◆  
□◇◆  
ERZV14D271 V14271U ○◎☆★  
ERZV20D271 V20271U ○◎☆★  
100 10000 7000  
Measuring Current of Varistor Voltage 5 Series : 0.1 mA, Others: 1 mA  
: UL1449 (VZCA2/UL, VZCA8/C-UL),  
: UL1449 Type3 (or Code-Connected and Direct plug-in),  
: UL1449 Type2 (or Permanently Connected),  
: VDE (IEC61051-1, -2, -2-2),  
: VDE (IEC60950-1 Annex.Q), : CSA C22.2 No.1  
: CQC (GB/T10193, GB/T10194),  
: CQC (GB4943.1, GB8898)  
Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
02 Aug. 2013  
– 6 –  
“ZNR” Transient/Surge Absorbers (Type D)  
Reference Guide to Standard Products  
Maximum  
Allowable  
Voltage  
Clamping  
Voltage  
at 8/20μs  
Maximum  
Peak Current  
at 8/20μs(A)  
Applicable  
Standards  
Varistor  
Voltage  
Part No.  
Recommended Applications  
Type Name Approvals  
(V)  
ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times  
□◇  
□◇  
□◇  
□◇  
ERZV05D331  
V331U  
○☆  
○☆  
○☆  
○☆  
570  
545  
545  
545  
545  
545  
620  
595  
595  
595  
595  
5
10  
25  
25  
50  
800  
600  
ERZV07D331 V7331U  
ERZV09D331 V9331U  
ERZV10D331 V10331U  
1750 1250  
3500 2500  
3500 2500  
6000 4500  
330  
(297 to 363)  
210  
230  
250  
275  
270  
300  
320  
350  
□◇◆  
□◇◆  
ERZV14D331 V14331U ○◎☆★  
ERZV20D331 V20331U ○◎☆★  
100 10000 6500  
□◇  
ERZV05D361  
V361U  
○☆  
○☆  
○☆  
○☆  
5
10  
25  
25  
50  
800  
600  
AC 100 V to 120 V, Line–Line  
Applications  
□◇  
□◇  
□◇  
ERZV07D361 V7361U  
ERZV09D361 V9361U  
ERZV10D361 V10361U  
1750 1250  
3500 2500  
3500 2500  
6000 4500  
360  
(324 to 396)  
Telephone Line Applications,  
(For DC 250 V Insulation  
Resistance Test)  
□◇◆  
□◇◆  
ERZV14D361 V14361U ○◎☆★  
ERZV20D361 V20361U ○◎☆★  
595 100 10000 6500  
□◇  
ERZV05D391  
V391U  
○☆  
○☆  
○☆  
○☆  
675  
650  
650  
650  
650  
5
10  
25  
25  
50  
800  
600  
□◇  
□◇  
□◇  
ERZV07D391 V7391U  
ERZV09D391 V9391U  
ERZV10D391 V10391U  
1750 1250  
3500 2500  
3500 2500  
6000 4500  
390  
(351 to 429)  
□◇◆  
□◇◆  
ERZV14D391 V14391U ○◎☆★  
ERZV20D391 V20391U ○◎☆★  
650 100 10000 6500  
□◇  
ERZV05D431  
V431U  
○☆  
○☆  
○☆  
○☆  
745  
710  
710  
710  
710  
5
10  
25  
25  
50  
800  
600  
□◇  
□◇  
□◇  
ERZV07D431 V7431U  
ERZV09D431 V9431U  
ERZV10D431 V10431U  
1750 1250  
3500 2500  
3500 2500  
6000 4500  
430  
(387 to 473)  
□◇◆  
□◇◆  
ERZV14D431 V14431U ○◎☆★  
ERZV20D431 V20431U ○◎☆★  
AC 100 V to 220 V, Line–Line  
and  
Line–Ground Applications  
710 100 10000 6500  
□◇  
ERZV05D471  
V471U  
○☆  
○☆  
○☆  
810  
775  
775  
775  
775  
5
10  
25  
25  
50  
800  
600  
□◇  
□◇  
ERZV07D471 V7471U  
ERZV09D471 V9471U  
1750 1250  
3500 2500  
3500 2500  
6000 4500  
470  
(423 to 517)  
300  
320  
385  
410  
□◇◆  
□◇◆  
□◇◆  
ERZV10D471 V10471U ○●☆★  
ERZV14D471 V14471U ○◎☆★  
ERZV20D471 V20471U ○◎☆★  
775 100 10000 6500  
□◇  
ERZV07D511 V7511U  
ERZV09D511 V9511U  
○☆  
○☆  
845  
845  
845  
845  
10  
25  
25  
50  
1750 1250  
3500 2500  
3500 2500  
6000 4500  
□◇  
510  
(459 to 561)  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
ERZV10D511 V10511U ○●☆★  
ERZV14D511 V14511U ○◎☆★  
ERZV20D511 V20511U ○◎☆★  
ERZV10D561 V10561U ○●☆★  
ERZV14D561 V14561U ○◎☆★  
ERZV20D561 V20561U ○◎☆★  
ERZV10D621 V10621U ○●☆★  
ERZV14D621 V14621U ○◎☆★  
ERZV20D621 V20621U ○◎☆★  
ERZV10D681 V10681U ○●☆★  
ERZV14D681 V14681U ○◎☆★  
ERZV20D681 V20681U ○◎☆★  
845 100 10000 6500  
930  
930  
25  
50  
3500 2500  
5000 4500  
7500 6500  
3500 2500  
5000 4500  
7500 6500  
3500 2500  
5000 4500  
7500 6500  
560  
(504 to 616)  
AC 100 to 240 V, Line–Line  
and  
Line–Ground Applications  
350  
385  
420  
450  
505  
560  
930 100  
1025  
1025  
25  
50  
620  
(558 to 682)  
1025 100  
1120  
1120  
25  
50  
680  
(612 to 748)  
1120 100  
Measuring Current of Varistor Voltage 5 Series : 0.1 mA, Others: 1 mA  
: UL1449 (VZCA2/UL, VZCA8/C-UL),  
: UL1449 Type3 (or Code-Connected and Direct plug-in),  
: UL1449 Type2 (or Permanently Connected),  
: VDE (IEC61051-1, -2, -2-2),  
: VDE (IEC60950-1 Annex.Q), : CSA C22.2 No.1  
: CQC (GB/T10193, GB/T10194),  
: CQC (GB4943.1, GB8898)  
Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
02 Aug. 2013  
– 7 –  
“ZNR” Transient/Surge Absorbers (Type D)  
Reference Guide to Standard Products  
Maximum  
Allowable  
Voltage  
Clamping  
Voltage  
at 8/20μs  
Maximum  
Peak Current  
at 8/20μs(A)  
Applicable  
Standards  
Varistor  
Voltage  
Part No.  
Recommended Applications  
Type Name Approvals  
(V)  
ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times  
□◇◆  
ERZV10D751 V10751U ○●☆★  
ERZV14D751 V14751U ○◎☆★  
ERZV20D751 V20751U ○◎☆★  
ERZV10D821 V10821U ○●☆★  
ERZV14D821 V14821U ○◎☆★  
ERZV20D821 V20821U ○◎☆★  
ERZV10D911 V10911U ○●☆★  
ERZV14D911 V14911U ○◎☆★  
ERZV20D911 V20911U ○◎☆★  
ERZV10D102 V10102U ○●☆★  
ERZV14D102 V14102U ○◎☆★  
ERZV20D102 V20102U ○◎☆★  
ERZV10D112 V10112U ○●☆★  
ERZV14D112 V14112U ○◎☆★  
ERZV20D112 V20112U ○◎☆★  
ERZV10D182CS V10182U ○●☆★  
ERZV14D182CS V14182U ○◎☆★  
ERZV20D182 V20182U ○◎☆★  
1240  
1240  
1240  
1355  
1355  
1355  
1500  
1500  
1500  
1650  
1650  
1650  
1815  
1815  
1815  
2970  
2970  
2970  
25  
50  
3500 2500  
5000 4500  
7500 6500  
3500 2500  
5000 4500  
7500 6500  
3500 2500  
750  
(675 to 825)  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
□◇◆  
460  
510  
615  
670  
AC 380 V, Line–Line and  
Line–Ground Applications  
(For DC 500 V Insulating Test)  
100  
25  
820  
(738 to 902)  
50  
100  
25  
AC 415 V, Line–Line and  
910  
(819 to 1001)  
550  
745  
50  
5000 4500 Line–Ground Applications  
(For DC 500 V Insulating Test)  
100  
25  
7500 6500  
3500 2500  
5000 4500  
1000  
(900 to 1100)  
625  
825  
50  
AC 480 V, Line–Line and  
Line–Ground Applications  
(For DC 500 V Insulating Test)  
100  
25  
7500 6500  
3500 2500  
1100  
(990 to 1210)  
680  
895  
50  
5000 4500  
7500 6500  
100  
25  
3500 2500  
Line–Ground Applications  
1800  
(1700 to 1980)  
1000  
1465  
50  
5000 4500 (For AC 1200 V Withstanding  
Test)  
100  
7500 6500  
Measuring Current of Varistor Voltage 5 Series : 0.1 mA, Others: 1 mA  
: UL1449 (VZCA2/UL, VZCA8/C-UL),  
: UL1449 Type3 (or Code-Connected and Direct plug-in),  
: UL1449 Type2 (or Permanently Connected),  
: VDE (IEC61051-1, -2, -2-2),  
: VDE (IEC60950-1 Annex.Q), : CSA C22.2 No.1  
: CQC (GB/T10193, GB/T10194),  
: CQC (GB4943.1, GB8898)  
Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
02 Aug. 2013  
– 8 –  
“ZNR” Transient/Surge Absorbers (Type D)  
5 Series  
Ratings and Characteristics  
Operating Temperature Range : 40 to 85  
°C  
°C  
Storage Temperature Range : 40 to 125  
Maximum  
Peak Current  
(8/20 μs)  
Clamping  
Voltage  
(max.)  
Maximum  
Energy  
Maximum  
Allowable  
Voltage  
Varistor  
Voltage  
Rated  
Power  
Capacitance  
(max.)  
Part No.  
✽✽  
Ip  
(10/1000 μs) (2 ms) 1 time 2 times  
0.1 mA  
V
(V)  
ACrms (V) DC (V)  
(V)  
(W)  
(J)  
(J)  
(A)  
(A) at 1 kHz (pF)  
ERZV05D180  
ERZV05D220  
ERZV05D270  
18(16 to 20)  
22(20 to 24)  
27(24 to 30)  
11  
14  
17  
20  
25  
30  
35  
40  
50  
14  
18  
22  
26  
31  
38  
45  
56  
65  
40  
48  
60  
73  
86  
0.01  
0.01  
0.01  
0.01  
0.01  
0.01  
0.01  
0.01  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.6  
0.7  
0.9  
1.1  
1.2  
1.5  
1.8  
2.2  
3.5  
4.0  
5.0  
6.5  
8.5  
0.4  
0.5  
0.7  
0.8  
0.9  
1.1  
250 125  
250 125  
250 125  
250 125  
250 125  
250 125  
250 125  
250 125  
800 600  
800 600  
800 600  
800 600  
800 600  
800 600  
800 600  
800 600  
800 600  
800 600  
800 600  
800 600  
800 600  
1600  
1500  
1450  
1400  
700  
650  
600  
580  
460  
400  
350  
300  
120  
110  
100  
90  
ERZV05D330 33(30 to 36)  
ERZV05D390 39(35 to 43)  
ERZV05D470  
47(42 to 52)  
104  
123  
150  
145  
175  
210  
260  
355  
380  
415  
475  
570  
620  
675  
745  
810  
ERZV05D560 56(50 to 62)  
ERZV05D680 68(61 to 75)  
ERZV05D820  
1.3  
1.6  
82(74 to 90)  
2.5  
3.0  
3.5  
4.5  
6.0  
6.5  
7.5  
8.0  
9.5  
11.0  
12.0  
13.5  
15.0  
ERZV05D101 100(90 to 110)  
ERZV05D121 120(108 to 132)  
ERZV05D151 150(135 to 165)  
ERZV05D201 200(185 to 225)  
ERZV05D221 220(198 to 242)  
ERZV05D241 240(216 to 264)  
ERZV05D271 270(247 to 303)  
ERZV05D331 330(297 to 363)  
ERZV05D361 360(324 to 396)  
ERZV05D391 390(351 to 429)  
ERZV05D431 430(387 to 473)  
ERZV05D471 470(423 to 517)  
60  
75  
95  
85  
100  
125  
170  
180  
200  
225  
270  
300  
320  
350  
385  
130  
140  
150  
175  
210  
230  
250  
275  
300  
9.0  
10.5  
11.0  
13.0  
16.0  
17.0  
20.0  
21.0  
80  
80  
80  
70  
60  
Measured at 1 MHz  
Ip Measuring current of clamping voltage 180 to 680 : 1 A, 820 to 471 : 5 A  
✽✽  
Refer to page 24 to 26 about leads cut type and taping.  
Dimensions in mm (not to scale)  
Part No.  
D max.  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
7.0  
T max.  
4.5  
4.5  
4.5  
4.5  
4.5  
4.5  
4.5  
4.5  
4.1  
4.3  
4.5  
4.8  
4.4  
4.5  
4.6  
4.8  
5.1  
5.3  
5.4  
5.6  
5.8  
W
H max.  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
L
1.0  
1.0  
1.5  
ERZV05D180  
ERZV05D220  
ERZV05D270  
ERZV05D330  
ERZV05D390  
ERZV05D470  
ERZV05D560  
ERZV05D680  
ERZV05D820  
ERZV05D101  
ERZV05D121  
ERZV05D151  
ERZV05D201  
ERZV05D221  
ERZV05D241  
ERZV05D271  
ERZV05D331  
ERZV05D361  
ERZV05D391  
ERZV05D431  
ERZV05D471  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.5  
1.4  
1.6  
1.8  
2.1  
1.7  
1.8  
1.9  
2.1  
2.4  
2.5  
2.7  
2.9  
3.1  
D
T
L
W
f
0.6  
W
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 9 –  
“ZNR” Transient/Surge Absorbers (Type D)  
(Relation between impulse  
width and impulse current multiple)  
Impulse Derating  
Typical Characteristics  
Voltage vs. Current  
ERZV05D180 to ERZV05D680  
ERZV05D180 to ERZV05D680  
1000  
Max. Clamping Voltage  
Max.  
2 times : 5 min. interval  
400 Leakage Current  
680  
560  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
300  
470  
390  
330  
200  
270  
220  
180  
100  
10  
1
390  
100  
90  
80  
70  
60  
680  
50  
560  
470  
40  
30  
330  
270  
220  
20  
180  
10  
9
Test current waveform  
10–6 to 10–4 A: Direct current  
10–1 to 103 A: 8/20 μs  
8
7
6
5
4
3
0.1  
2  
10–6 10–5  
10–4  
10–3  
10  
10–1 100  
Current (A)  
101  
102  
103  
104  
105  
20  
100  
1000  
10000  
Impulse Width (μs)  
ERZV05D820 to ERZV05D471  
ERZV05D820 to ERZV05D471  
1000  
.BYꢅꢆ$MBNQJOHꢆ7PMUBHF  
.BYꢅ  
-FBLBHFꢆ$VSSFOU  
2 times : 5 min. interval  
2000  
up to 10 times : 2 min. interval  
up to 106 times : 10 sec. interval  
471  
431  
391  
361  
331  
271  
241  
221  
201  
ꢀꢁꢂ  
ꢁꢃꢂ  
ꢁꢄꢂ  
1000  
900  
800  
700  
100  
1 Time  
2 Times  
10  
600  
3Times  
500  
151  
400  
300  
471  
121  
101  
820  
10  
271  
241  
200  
10  
6Times  
201  
151  
100  
90  
80  
70  
60  
121  
1
101  
820  
Test Current Waveform  
50  
10-6 to 10-4 A: Direct Current  
10-1 to 103 A: 8/20 μs  
331  
221  
40  
30  
10-6  
0.1  
20  
10-5  
10-4  
10-3  
10-2  
10-1  
100  
101  
102  
103  
104  
105  
100  
1000  
10000  
Current (A)  
Impulse Width (μs)  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 10 –  
“ZNR” Transient/Surge Absorbers (Type D)  
7 Series  
Ratings and Characteristics  
Operating Temperature Range: 40 to 85  
°C  
°C  
Storage Temperature Range: 40 to 125  
Maximum  
Peak Current  
(8/20 μs)  
Clamping  
Voltage  
(max.)  
Maximum  
Energy  
Maximum  
Allowable  
Voltage  
Varistor  
Voltage  
Rated  
Power  
Capacitance  
(max.)  
Part No.  
✽✽  
Ip  
(10/1000 μs) (2 ms) 1 time 2 times  
1 mA  
V
(V)  
ACrms (V) DC (V)  
(V)  
(W)  
(J)  
(J)  
(A)  
(A) at 1 kHz (pF)  
ERZV07D180  
ERZV07D220  
ERZV07D270  
ERZV07D330 33(30 to 36)  
ERZV07D390 39(35 to 43)  
ERZV07D470  
ERZV07D560 56(50 to 62)  
ERZV07D680 68(61 to 75)  
18(16 to 20)  
22(20 to 24)  
27(24 to 30)  
11  
14  
17  
20  
25  
30  
35  
40  
50  
14  
18  
22  
26  
31  
38  
45  
56  
65  
36  
43  
53  
65  
77  
0.02  
0.02  
0.02  
0.02  
0.02  
0.02  
0.02  
0.02  
0.25  
0.25  
0.25  
0.25  
0.25  
0.25  
0.25  
0.25  
0.25  
0.25  
0.25  
0.25  
0.25  
0.25  
1.1  
1.3  
1.6  
2.0  
2.4  
2.8  
3.4  
4.1  
7
0.9  
1.1  
1.3  
1.6  
1.9  
2.3  
2.7  
3.3  
5
500 250  
500 250  
500 250  
500 250  
500 250  
500 250  
500 250  
500 250  
1750 1250  
1750 1250  
1750 1250  
1750 1250  
3800  
3600  
3400  
2900  
1600  
1550  
1500  
1200  
810  
47(42 to 52)  
93  
110  
135  
135  
165  
200  
250  
340  
360  
395  
455  
545  
595  
650  
710  
775  
845  
ERZV07D820  
82(74 to 90)  
ERZV07D101 100(90 to 110)  
ERZV07D121 120(108 to 132)  
ERZV07D151 150(135 to 165)  
ERZV07D201 200(185 to 225)  
ERZV07D221 220(198 to 242)  
ERZV07D241 240(216 to 264)  
ERZV07D271 270(247 to 303)  
ERZV07D331 330(297 to 363)  
ERZV07D361 360(324 to 396)  
ERZV07D391 390(351 to 429)  
ERZV07D431 430(387 to 473)  
ERZV07D471 470(423 to 517)  
ERZV07D511 510(459 to 561)  
60  
75  
95  
85  
8.5  
10  
6
7
9
700  
100  
125  
170  
180  
200  
225  
270  
300  
320  
350  
385  
410  
590  
500  
200  
190  
170  
150  
130  
130  
130  
120  
13  
17.5  
19  
21  
24  
28  
32  
35  
40  
42  
45  
130  
140  
150  
175  
210  
230  
250  
275  
300  
320  
12.5 1750 1250  
13.5 1750 1250  
15  
17  
20  
23  
25  
1750 1250  
1750 1250  
1750 1250  
1750 1250  
1750 1250  
27.5 1750 1250  
30  
32  
1750 1250  
1750 1250  
100  
90  
Measured at 1 MHz  
Ip Measuring current of clamping voltage 180 to 680 : 25 A, 820 tp 511 : 10 A  
✽✽  
Refer to page 24 to 26 about leads cut type and taping.  
Dimensions in mm (not to scale)  
Part No.  
D max.  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
8.5  
T max.  
4.5  
4.6  
4.7  
4.9  
4.8  
4.9  
5.0  
5.2  
4.1  
4.3  
4.5  
4.8  
4.4  
4.5  
4.6  
4.8  
5.1  
5.3  
5.4  
5.6  
5.8  
6.0  
W
H max.  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
L
1.0  
1.0  
1.3  
ERZV07D180  
ERZV07D220  
ERZV07D270  
ERZV07D330  
ERZV07D390  
ERZV07D470  
ERZV07D560  
ERZV07D680  
ERZV07D820  
ERZV07D101  
ERZV07D121  
ERZV07D151  
ERZV07D201  
ERZV07D221  
ERZV07D241  
ERZV07D271  
ERZV07D331  
ERZV07D361  
ERZV07D391  
ERZV07D431  
ERZV07D471  
ERZV07D511  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
1.4  
1.5  
1.7  
1.6  
1.7  
1.8  
2.0  
1.4  
1.6  
1.8  
2.1  
1.7  
1.8  
1.9  
2.1  
2.4  
2.5  
2.7  
2.9  
3.1  
3.3  
D
T
L
W
f
0.6  
W
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
11 –  
“ZNR” Transient/Surge Absorbers (Type D)  
(Relation between impulse  
width and impulse current multiple)  
Impulse Derating  
Typical Characteristics  
Voltage vs. Current  
ERZV07D180 to ERZV07D680  
ERZV07D180 to ERZV07D680  
1000  
Max. Clamping Voltage  
Max.  
400  
2 times : 5 min. interval  
Leakage Current  
680  
560  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
300  
470  
390  
330  
270  
220  
180  
200  
100  
10  
1
100  
90  
80  
70  
60  
50  
680  
40  
560  
470  
30  
390  
330  
20  
270  
220  
180  
10  
9
Test current waveform  
10–6 to 10–3 A: Direct current  
10–1 to 103 A: 8/20 μs  
8
7
6
5
4
3
0.1  
20  
10–6 10–5  
10–4  
10–3  
10–2  
10–1  
100  
101  
102  
103  
104  
105  
100  
1000  
10000  
Current (A)  
Impulse Width (μs)  
ERZV07D820 to ERZV07D511  
ERZV07D820 to ERZV07D511  
10000  
.BYꢀꢁ$MBNQJOHꢁ7PMUBHF  
.BYꢀ  
-FBLBHFꢁ$VSSFOU  
2 times : 5 min. interval  
2000  
511  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
471  
431  
391  
361  
331  
271  
241  
221  
201  
471  
431  
391  
361  
1000  
900  
800  
700  
1000  
2 Times  
600  
10  
500  
2Times  
151  
121  
10  
10  
400  
300  
511  
1 Time  
3Times  
4Times  
5Times  
101  
820  
10 Times  
100  
10  
271  
241  
200  
201  
151  
10  
100  
90  
80  
70  
60  
6Times  
121  
10  
101  
820  
Test Current Waveform  
10-6 to 10-3 A: Direct Current  
10-1 to 104 A: 8/20 μs  
50  
331  
221  
40  
30  
10-6  
1
20  
10-5  
10-4  
10-3  
10-2  
10-1  
100  
101  
102  
103  
104  
105  
100  
1000  
10000  
Impulse Width (μs)  
Current (A)  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 12 –  
“ZNR” Transient/Surge Absorbers (Type D)  
9 Series  
Ratings and Characteristics  
Operating Temperature Range : 40 to 85  
°C  
°C  
Storage Temperature Range : 40 to 125  
Maximum  
Peak Current  
(8/20 μs)  
Clamping  
Voltage  
(max.)  
Maximum  
Energy  
Maximum  
Allowable  
Voltage  
Varistor  
Voltage  
Rated  
Power  
Capacitance  
(max.)  
Part No.  
Ip  
(10/1000 μs) (2 ms) 1 time 2 times  
1 mA  
V
(V)  
ACrms (V) DC (V)  
(V)  
(W)  
(J)  
(J)  
(A)  
(A) at 1 kHz (pF)  
ERZV09D180  
ERZV09D220 22(20 to 24)  
ERZV09D270 27(24 to 30)  
ERZV09D330 33(30 to 36)  
ERZV09D390 39(35 to 43)  
ERZV09D470  
18(16 to 20)  
11  
14  
17  
20  
25  
30  
35  
40  
50  
14  
18  
22  
26  
31  
38  
45  
56  
65  
36  
43  
53  
65  
77  
0.05  
0.05  
0.05  
0.05  
0.05  
0.05  
0.05  
0.05  
0.4  
0.4  
0.4  
0.4  
0.4  
0.4  
0.4  
0.4  
0.4  
0.4  
0.4  
0.4  
0.4  
2.6  
3.2  
3.9  
4.8  
5.6  
6.8  
8.1  
9.8  
2.2 1000 500  
2.6 1000 500  
3.2 1000 500  
4.0 1000 500  
4.7 1000 500  
5.6 1000 500  
6.7 1000 500  
8.2 1000 500  
16000  
11000  
8000  
6300  
5200  
4600  
3750  
2800  
2000  
1700  
1400  
1100  
430  
47(42 to 52)  
93  
ERZV09D560 56(50 to 62)  
ERZV09D680 68(61 to 75)  
ERZV09D820 82(74 to 90)  
ERZV09D101 100(90 to 110)  
ERZV09D121 120(108 to 132)  
ERZV09D151 150(135 to 165)  
ERZV09D201 200(185 to 225)  
ERZV09D221 220(198 to 242)  
ERZV09D241 240(216 to 264)  
ERZV09D271 270(247 to 303)  
ERZV09D331 330(297 to 363)  
ERZV09D361 360(324 to 396)  
ERZV09D391 390(351 to 429)  
ERZV09D431 430(387 to 473)  
ERZV09D471 470(423 to 517)  
ERZV09D511 510(459 to 561)  
110  
135  
135  
165  
200  
250  
340  
360  
395  
455  
545  
595  
650  
710  
775  
845  
14  
10  
12  
3500 2500  
3500 2500  
60  
75  
95  
85  
17  
20  
25  
35  
39  
42  
49  
58  
65  
70  
80  
85  
92  
100  
125  
170  
180  
200  
225  
270  
300  
320  
350  
385  
410  
14.5 3500 2500  
18  
25  
3500 2500  
3500 2500  
130  
140  
150  
175  
210  
230  
250  
275  
300  
320  
27.5 3500 2500  
410  
380  
350  
300  
300  
300  
270  
230  
30  
35  
42  
45  
50  
55  
60  
67  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
0.4  
210  
Ip Measuring current of clamping voltage 180 to 680 : 5 A, 820 to 511 : 25 A  
Refer to page 24 to 26 about leads cut type and taping.  
Dimensions in mm (not to scale)  
Part No.  
D max.  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
T max.  
3.8  
4.0  
4.2  
4.5  
4.0  
4.2  
4.4  
4.5  
3.8  
3.9  
4.1  
4.4  
4.1  
4.2  
4.3  
4.5  
4.8  
5.0  
5.1  
5.3  
5.6  
5.8  
W
H max.  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
14.0  
L
1.0  
1.0  
1.3  
ERZV09D180  
ERZV09D220  
ERZV09D270  
ERZV09D330  
ERZV09D390  
ERZV09D470  
ERZV09D560  
ERZV09D680  
ERZV09D820  
ERZV09D101  
ERZV09D121  
ERZV09D151  
ERZV09D201  
ERZV09D221  
ERZV09D241  
ERZV09D271  
ERZV09D331  
ERZV09D361  
ERZV09D391  
ERZV09D431  
ERZV09D471  
ERZV09D511  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
1.4  
1.5  
1.7  
1.7  
1.8  
1.9  
2.2  
1.6  
1.8  
2.0  
2.2  
1.7  
1.8  
1.9  
2.0  
2.3  
2.5  
2.6  
2.8  
3.1  
3.2  
D
T
L
W
f
0.6  
W
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 13 –  
“ZNR” Transient/Surge Absorbers (Type D)  
(Relation between impulse  
width and impulse current multiple)  
Impulse Derating  
Typical Characteristics  
Voltage vs. Current  
ERZV09D180 to ERZV09D680  
ERZV09D180 to ERZV09D680  
1000  
Max. Clamping Voltage  
Max.  
680  
560  
470  
Leakage Current  
400  
2 times : 5 min. interval  
up to 10 times : 2 min. interval  
up to 106 times : 10 sec. interval  
300  
390  
330  
270  
200  
220  
180  
100  
10  
1
100  
90  
80  
70  
60  
50  
680  
40  
560  
470  
30  
390  
20  
330  
270  
220  
10  
180  
9
8
7
Test current waveform  
10–6 to 10–3 A: Direct current  
10–1 to 103 A: 8/20 μs  
6
5
4
3
0.1  
20  
10–6 10–5  
10–4  
10–3  
10–2  
10–1  
100  
101  
102  
103  
104  
105  
100  
1000  
10000  
Impulse Width (μs)  
Current (A)  
ERZV09D820 to ERZV09D511  
ERZV09D820 to ERZV09D511  
10000  
2 times : 5 min. interval  
.BYꢀꢁ$MBNQJOHꢁ7PMUBHF  
.BYꢀ  
-FBLBHFꢁ$VSSFOU  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
2000  
511  
471  
431  
391  
361  
331  
271  
241  
221  
201  
471  
431  
391  
361  
1000  
900  
800  
700  
1000  
600  
151  
500  
511  
271  
121  
101  
400  
300  
100  
820  
200  
241  
201  
151  
100  
90  
80  
70  
60  
121  
10  
101  
820  
Test Current Waveform  
10-6 to 10-3 A: Direct Current  
10-1 to 104 A: 8/20 μs  
50  
331  
221  
40  
30  
1
20  
10-6  
10-5  
10-4  
10-3  
10-2  
10-1  
100  
101  
102  
103  
104  
105  
100  
1000  
10000  
Impulse Width (μs)  
Current (A)  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 14 –  
“ZNR” Transient/Surge Absorbers (Type D)  
10 Series  
Ratings and Characteristics  
Operating Temperature Range : 40 to 85  
°C  
°C  
Storage Temperature Range : 40 to 125  
Maximum  
Peak Current  
(8/20 µs)  
Clamping  
Voltage  
(max.)  
Maximum  
Energy  
Maximum  
Allowable  
Voltage  
Varistor  
Voltage  
Rated  
Power  
Capacitance  
(max.)  
Part No.  
✽✽  
Ip  
(10/1000 µs) (2 ms) 1 time 2 times  
(A) at 1 kHz (pF)  
1 mA  
V
(V)  
ACrms (V) DC (V)  
(V)  
(W)  
(J)  
2.6  
(J)  
(A)  
ERZV10D180  
ERZV10D220  
ERZV10D270  
ERZV10D330  
ERZV10D390  
ERZV10D470  
ERZV10D560  
ERZV10D680  
ERZV10D820  
ERZV10D101  
ERZV10D121  
ERZV10D151  
18(16 to 20)  
22(20 to 24)  
27(24 to 30)  
33(30 to 36)  
39(35 to 43)  
47(42 to 52)  
56(50 to 62)  
68(61 to 75)  
82(74 to 90)  
100(90 to 110)  
120(108 to 132)  
150(135 to 165)  
11  
14  
14  
18  
36  
43  
0.05  
0.05  
0.05  
0.05  
0.05  
0.05  
0.05  
0.05  
0.4  
2.2 1000 500  
2.6 1000 500  
3.2 1000 500  
4.0 1000 500  
4.7 1000 500  
5.6 1000 500  
6.7 1000 500  
8.2 1000 500  
16000  
11000  
8000  
6300  
5200  
4600  
3750  
2800  
2000  
1700  
1400  
1100  
430  
3.2  
3.9  
4.8  
5.6  
6.8  
8.1  
9.8  
17  
22  
53  
20  
26  
65  
25  
31  
77  
30  
38  
93  
35  
45  
110  
40  
56  
135  
135  
165  
200  
250  
340  
360  
395  
455  
545  
595  
650  
710  
775  
845  
930  
1025  
1120  
1240  
1355  
1500  
1650  
1815  
2970  
50  
65  
14  
10  
12  
3500 2500  
3500 2500  
60  
85  
0.4  
17  
20  
75  
100  
125  
170  
180  
200  
225  
270  
300  
320  
350  
385  
410  
450  
505  
560  
615  
670  
745  
825  
895  
1465  
0.4  
14.5 3500 2500  
95  
0.4  
25  
18  
25  
3500 2500  
3500 2500  
ERZV10D201 200(185 to 225)  
ERZV10D221 220(198 to 242)  
130  
140  
150  
175  
210  
230  
250  
275  
300  
320  
350  
385  
420  
460  
510  
550  
625  
680  
1000  
0.4  
35  
0.4  
39  
27.5 3500 2500  
410  
ERZV10D241  
240(216 to 264)  
0.4  
42  
30  
35  
42  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
3500 2500  
380  
ERZV10D271 270(247 to 303)  
ERZV10D331 330(297 to 363)  
ERZV10D361 360(324 to 396)  
ERZV10D391 390(351 to 429)  
ERZV10D431 430(387 to 473)  
0.4  
49  
350  
0.4  
58  
300  
0.4  
65  
45  
50  
300  
0.4  
70  
300  
0.4  
80  
55  
270  
ERZV10D471  
ERZV10D511  
470(423 to 517)  
510(459 to 561)  
0.4  
85  
60  
67  
230  
0.4  
92  
210  
ERZV10D561 560(504 to 616)  
ERZV10D621 620(558 to 682)  
ERZV10D681 680(612 to 748)  
0.4  
92  
67  
200  
0.4  
92  
67  
190  
0.4  
92  
67  
170  
ERZV10D751  
750(675 to 825)  
0.4  
100  
110  
130  
140  
155  
247  
70  
160  
ERZV10D821 820(738 to 902)  
ERZV10D911 910(819 to 1001)  
ERZV10D102 1000(900 to 1100)  
ERZV10D112 1100(990 to 1210)  
ERZV10D182CS 1800(1700 to 1980)  
0.4  
80  
90  
100  
110  
183  
140  
0.4  
120  
0.4  
110  
0.4  
110  
0.4  
70  
Measured at 1 MHz  
Ip Measuring current of clamping voltage 180 to 680 : 5 A, 820 to 182 : 25 A  
✽✽  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 15 –  
“ZNR” Transient/Surge Absorbers (Type D)  
Refer to page 24 to 26 about leads cut type and taping.  
Dimensions in mm (not to scale)  
D
Part No.  
D max.  
T max.  
W
1.0  
7.5  
H max.  
L
1.0  
1.3  
T
ERZV10D180  
ERZV10D220  
ERZV10D270  
ERZV10D330  
ERZV10D390  
ERZV10D470  
ERZV10D560  
ERZV10D680  
ERZV10D820  
ERZV10D101  
ERZV10D121  
ERZV10D151  
ERZV10D201  
ERZV10D221  
ERZV10D241  
ERZV10D271  
ERZV10D331  
ERZV10D361  
ERZV10D391  
ERZV10D431  
ERZV10D471  
ERZV10D511  
ERZV10D561  
ERZV10D621  
ERZV10D681  
ERZV10D751  
ERZV10D821  
ERZV10D911  
ERZV10D102  
ERZV10D112  
ERZV10D182CS  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
11.5  
12.5  
12.5  
12.5  
12.5  
12.5  
12.5  
12.5  
12.5  
13.5  
4.6  
4.7  
4.8  
5.0  
4.9  
5.0  
5.1  
5.3  
4.5  
4.7  
4.9  
5.2  
4.8  
4.9  
5.0  
5.2  
5.5  
5.7  
5.8  
6.0  
6.2  
6.4  
6.7  
7.1  
7.4  
7.8  
8.1  
8.6  
9.1  
9.7  
14.4  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
14.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
16.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
1.4  
1.5  
1.7  
1.6  
1.7  
1.8  
2.0  
1.6  
1.8  
2.0  
2.3  
1.9  
2.0  
2.1  
2.3  
2.6  
2.8  
2.9  
3.1  
3.3  
3.5  
3.8  
4.2  
4.5  
4.9  
5.2  
5.7  
6.2  
6.8  
L
W
f
0.8  
W
(ERZV10D182CS)  
D
T
f
L
0.8  
11.0  
10.0( 1.5)  
2
: W  
Typical Characteristics  
Voltage vs. Current  
(Relation between impulse  
width and impulse current multiple)  
Impulse Derating  
ERZV10D180 to ERZV10D680  
ERZV10D180 to ERZV10D680  
1000  
Max. Clamping Voltage  
Max.  
2 times : 5 min. interval  
680  
560  
470  
Leakage Current  
400  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
300  
390  
330  
270  
100  
10  
1
200  
220  
180  
100  
90  
80  
70  
60  
50  
680  
40  
30  
560  
470  
390  
330  
270  
220  
180  
20  
0.1  
20  
100  
1000  
10000  
Impulse Width (µs)  
10  
9
8
7
6
Test current waveform  
10–6 to 10–3 A: Direct current  
10–1 to 103 A: 8/20 µs  
5
4
3
10–6  
10–5  
10–4  
10–3  
10–2  
10–1  
100  
101  
102  
103  
104  
105  
Current (A)  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 16 –  
“ZNR” Transient/Surge Absorbers (Type D)  
(Relation between impulse  
width and impulse current multiple)  
Impulse Derating  
Typical Characteristics  
Voltage vs. Current  
ERZV10D820 to ERZV10D511  
ERZV10D820 to ERZV10D511  
10000  
1000  
100  
2 times : 5 min. interval  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
.BYꢀꢁ$MBNQJOHꢁ7PMUBHF  
.BYꢀ  
-FBLBHFꢁ$VSSFOU  
2000  
511  
471  
431  
391  
361  
331  
271  
241  
221  
201  
471  
431  
391  
361  
1000  
900  
800  
700  
600  
151  
500  
121  
101  
400  
300  
511  
10  
1
820  
271  
241  
200  
100  
1000  
10000  
20  
Impulse Width (µs)  
201  
151  
100  
90  
80  
70  
60  
121  
101  
820  
ERZV10D561 to ERZV10D112  
10000  
2 times : 5 min. interval  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
50  
Test Current Waveform  
10-6 to 10-3 A: Direct Current  
10-1 to 104 A: 8/20 µs  
331  
221  
40  
30  
1000  
100  
10-6  
10-5  
10-4  
10-3  
10-2  
10-1  
Current (A)  
100  
101  
102  
103  
104  
105  
ERZV10D561 to ERZV10D182CS  
5000  
10  
1
.BYꢀꢁ$MBNQJOHꢁ7PMUBHF  
.BYꢀ  
-FBLBHFꢁ$VSSFOU  
182CS  
4000  
3000  
102  
911  
821  
112  
102  
911  
821  
20  
100  
1000  
10000  
Impulse Width (µs)  
2000  
751  
681  
621  
561  
ERZV10D182CS  
182CS  
112  
10000  
1000  
100  
2 times : 5 min. interval  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
1000  
900  
800  
700  
600  
500  
400  
300  
561  
10  
1
751  
681  
621  
Test Current Waveform  
10-6 to 10-3 A: Direct Current  
10-1 to 104 A: 8/20 µs  
200  
10-6  
10-5  
10-4  
10-3  
10-2  
10-1 100  
Current (A)  
101  
102  
103  
104  
105  
20  
100  
1000  
10000  
Impulse Width (µs)  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 17 –  
“ZNR” Transient/Surge Absorbers (Type D)  
14 Series  
Ratings and Characteristics  
Operating Temperature Range : 40 to 85  
°C  
°C  
Storage Temperature Range : 40 to 125  
Maximum  
Peak Current  
(8/20 µs)  
Clamping  
Voltage  
(max.)  
Maximum  
Energy  
Maximum  
Allowable  
Voltage  
Varistor  
Voltage  
Rated  
Power  
Capacitance  
(max.)  
Part No.  
Ip  
(10/1000 µs) (2 ms) 1 time 2 times  
(A) at 1 kHz (pF)  
1 mA  
V
(V)  
ACrms (V) DC (V)  
(V)  
(W)  
(J)  
5.2  
(J)  
(A)  
ERZV14D180  
ERZV14D220  
ERZV14D270  
ERZV14D330  
ERZV14D390  
ERZV14D470  
ERZV14D560  
ERZV14D680  
ERZV14D820  
ERZV14D101  
ERZV14D121  
ERZV14D151  
18(16 to 20)  
22(20 to 24)  
27(24 to 30)  
33(30 to 36)  
39(35 to 43)  
47(42 to 52)  
56(50 to 62)  
68(61 to 75)  
82(74 to 90)  
100(90 to 110)  
120(108 to 132)  
150(135 to 165)  
11  
14  
14  
18  
36  
43  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
4.3 2000 1000  
5.3 2000 1000  
6.5 2000 1000  
7.9 2000 1000  
9.4 2000 1000  
25000  
20000  
16000  
12200  
7000  
6750  
6500  
5500  
3700  
3200  
2700  
2200  
770  
6.3  
7.8  
9.5  
17  
22  
53  
20  
26  
65  
25  
31  
77  
11  
30  
38  
93  
14  
16  
11  
2000 1000  
2000 1000  
2000 1000  
6000 5000  
6000 5000  
6000 5000  
35  
45  
110  
13  
16  
20  
25  
30  
40  
56  
135  
135  
165  
200  
250  
340  
360  
395  
455  
545  
595  
650  
710  
775  
845  
930  
1025  
1120  
1240  
1355  
1500  
1650  
1815  
2970  
20  
50  
65  
28  
60  
85  
35  
75  
100  
125  
170  
180  
200  
225  
270  
300  
320  
350  
385  
410  
450  
505  
560  
615  
670  
745  
825  
895  
1465  
42  
95  
53  
37.5 6000 5000  
ERZV14D201 200(185 to 225)  
ERZV14D221 220(198 to 242)  
130  
140  
150  
175  
210  
230  
250  
275  
300  
320  
350  
385  
420  
460  
510  
550  
625  
680  
1000  
70  
50  
55  
6000 5000  
6000 5000  
6000 5000  
6000 5000  
6000 4500  
6000 4500  
6000 4500  
6000 4500  
6000 4500  
6000 4500  
5000 4500  
5000 4500  
5000 4500  
5000 4500  
5000 4500  
5000 4500  
5000 4500  
5000 4500  
5000 4500  
78  
740  
ERZV14D241  
240(216 to 264)  
84  
60  
700  
ERZV14D271 270(247 to 303)  
ERZV14D331 330(297 to 363)  
ERZV14D361 360(324 to 396)  
ERZV14D391 390(351 to 429)  
ERZV14D431 430(387 to 473)  
99  
70  
640  
115  
130  
140  
155  
175  
190  
190  
190  
190  
210  
235  
255  
280  
310  
510  
80  
580  
90  
540  
100  
110  
125  
136  
136  
136  
136  
150  
165  
180  
200  
220  
360  
500  
450  
ERZV14D471  
ERZV14D511  
470(423 to 517)  
510(459 to 561)  
400  
350  
ERZV14D561 560(504 to 616)  
ERZV14D621 620(558 to 682)  
ERZV14D681 680(612 to 748)  
340  
330  
320  
ERZV14D751  
750(675 to 825)  
310  
ERZV14D821 820(738 to 902)  
ERZV14D911 910(819 to 1001)  
ERZV14D102 1000(900 to 1100)  
ERZV14D112 1100(990 to 1210)  
ERZV14D182CS 1800(1700 to 1980)  
280  
250  
230  
210  
120  
Ip Measuring current of clamping voltage 180 to 680 : 10 A, 820 to 182 : 50 A  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 18 –  
“ZNR” Transient/Surge Absorbers (Type D)  
Refer to page 24 to 26 about leads cut type and taping.  
Dimensions in mm (not to scale)  
Part No.  
D max.  
T max.  
W
1.0  
7.5  
H max.  
L
1.0  
1.3  
D
T
ERZV14D180  
ERZV14D220  
ERZV14D270  
ERZV14D330  
ERZV14D390  
ERZV14D470  
ERZV14D560  
ERZV14D680  
ERZV14D820  
ERZV14D101  
ERZV14D121  
ERZV14D151  
ERZV14D201  
ERZV14D221  
ERZV14D241  
ERZV14D271  
ERZV14D331  
ERZV14D361  
ERZV14D391  
ERZV14D431  
ERZV14D471  
ERZV14D511  
ERZV14D561  
ERZV14D621  
ERZV14D681  
ERZV14D751  
ERZV14D821  
ERZV14D911  
ERZV14D102  
ERZV14D112  
ERZV14D182CS  
2
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
15.5  
16.0  
16.0  
16.0  
16.0  
16.0  
16.0  
16.0  
16.0  
17.0  
4.6  
4.7  
4.8  
5.0  
4.9  
5.0  
5.1  
5.3  
4.5  
4.7  
4.9  
5.2  
4.8  
4.9  
5.0  
5.2  
5.5  
5.7  
5.8  
6.0  
6.2  
6.4  
6.7  
7.1  
7.4  
7.8  
8.1  
8.6  
9.1  
9.7  
14.4  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
18.5  
19.0  
19.0  
19.0  
19.0  
19.0  
19.0  
19.0  
19.0  
20.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
1.4  
1.5  
1.7  
1.6  
1.7  
1.8  
2.0  
1.6  
1.8  
2.0  
2.3  
1.9  
2.0  
2.1  
2.3  
2.6  
2.8  
2.9  
3.1  
3.3  
3.5  
3.8  
4.2  
4.5  
4.9  
5.2  
5.7  
6.2  
6.8  
L
W
f
0.8  
W
(ERZV14D182CS)  
D
T
W2  
L
f
0.8  
15.0  
10.5( 2.0)  
: W  
Typical Characteristics  
Voltage vs. Current  
(Relation between impulse  
width and impulse current multiple)  
Impulse Derating  
ERZV14D180 to ERZV14D680  
ERZV14D180 to ERZV14D680  
10000  
.BYꢀꢁ$MBNQJOHꢁ7PMUBHF  
.BYꢀ  
-FBLBHFꢁ$VSSFOU  
2 times : 5 min. interval  
680  
400  
300  
up to 10 times : 2 min. interval  
560  
470  
up to 106 times :10 sec. interval  
390  
330  
200  
1000  
100  
10  
270  
220  
470  
10  
10  
2Times  
3Times  
100  
90  
80  
70  
60  
50  
180  
2 Times  
10 Ti
10  
5 Times  
680  
560  
40  
30  
390  
330  
270  
20  
220  
180  
1
20  
100  
1000  
10000  
10  
9
Impulse Width (µs)  
8
7
6
5
Test current waveform  
10–6 to 10–3 A: Direct current  
10–1 to 104 A: 8/20 µs  
4
3
10–6 10–5  
10–4  
10–3  
10–2  
10–1  
100  
101  
102  
103  
104  
105  
Current (A)  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 19 –  
“ZNR” Transient/Surge Absorbers (Type D)  
(Relation between impulse  
width and impulse current multiple)  
Impulse Derating  
Typical Characteristics  
Voltage vs. Current  
ERZV14D820 to ERZV14D511  
ERZV14D820 to ERZV14D511  
10000  
2 times : 5 min. interval  
.BYꢀꢁ$MBNQJOHꢁ7PMUBHF  
.BYꢀ  
-FBLBHFꢁ$VSSFOU  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
511  
471  
431  
391  
361  
331  
271  
241  
221  
201  
2000  
1000  
100  
471  
431  
391  
361  
1000  
900  
800  
700  
600  
151  
121  
500  
101  
820  
400  
300  
511  
10  
1
271  
241  
200  
20  
100  
1000  
10000  
Impulse Width (µs)  
201  
151  
100  
90  
80  
70  
60  
121  
ERZV14D561 to ERZV14D112  
101  
820  
10000  
2 times : 5 min. interval  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
Test Current Waveform  
50  
10-6 to 10-3 A: Direct Current  
10-1 to 104 A: 8/20 µs  
331  
221  
40  
30  
1000  
100  
10-6  
10-5  
10-4  
10-3  
10-2  
10-1  
Current (A)  
100  
101  
102  
103  
104  
105  
ERZV14D561 to ERZV14D182CS  
5000  
10  
1
.BYꢀꢁ$MBNQJOHꢁ7PMUBHF  
.BYꢀ  
-FBLBHFꢁ$VSSFOU  
182CS  
112  
4000  
102  
911  
821  
3000  
2000  
20  
100  
1000  
10000  
102  
911  
821  
751  
681  
621  
561  
Impulse Width (µs)  
ERZV14D182CS  
182CS  
112  
10000  
2 times : 5 min. interval  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
1000  
900  
800  
1000  
100  
700  
600  
500  
400  
300  
561  
10  
1
Test Current Waveform  
10-6 to 10-3 A: Direct Current  
10-1 to 104 A: 8/20 µs  
751  
681  
621  
200  
10-6  
10-5  
10-4  
10-3  
10-2  
10-1 100  
Current (A)  
101  
102  
103  
104  
105  
20  
100  
1000  
10000  
Impulse Width (µs)  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 20 –  
“ZNR” Transient/Surge Absorbers (Type D)  
20 Series  
Ratings and Characteristics  
Operating Temperature Range : 40 to 85  
°C  
°C  
Storage Temperature Range : 40 to 125  
Maximum  
Peak Current  
(8/20 µs)  
Clamping  
Voltage  
(max.)  
Maximum  
Energy  
Maximum  
Allowable  
Voltage  
Varistor  
Voltage  
Rated  
Power  
Capacitance  
(max.)  
Part No.  
Ip  
(10/1000 µs) (2 ms) 1 time 2 times  
(A) at 1 kHz (pF)  
1 mA  
V
(V)  
ACrms (V) DC (V)  
(V)  
(W)  
(J)  
13  
(J)  
12  
(A)  
ERZV20D180  
ERZV20D220  
ERZV20D270  
ERZV20D330  
ERZV20D390  
ERZV20D470  
ERZV20D560  
ERZV20D680  
ERZV20D820  
ERZV20D101  
18(16 to 20)  
22(20 to 24)  
27(24 to 30)  
33(30 to 36)  
39(35 to 43)  
47(42 to 52)  
56(50 to 62)  
68(61 to 75)  
82(74 to 90)  
100(90 to 110)  
11  
14  
14  
18  
36  
43  
0.2  
0.2  
0.2  
0.2  
0.2  
0.2  
0.2  
0.2  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
3000 2000  
3000 2000  
3000 2000  
3000 2000  
3000 2000  
3000 2000  
3000 2000  
3000 2000  
40000  
30000  
24500  
20000  
13800  
13500  
12200  
11500  
7500  
6500  
5500  
4500  
1700  
1600  
1500  
1300  
1100  
1100  
1100  
1000  
900  
16  
19  
14  
17  
21  
25  
30  
36  
44  
17  
22  
53  
20  
26  
65  
24  
25  
31  
77  
28  
30  
38  
93  
34  
35  
45  
110  
41  
40  
56  
135  
135  
165  
200  
250  
340  
360  
395  
455  
545  
595  
650  
710  
775  
845  
930  
1025  
1120  
1240  
1355  
1500  
1650  
1815  
2970  
49  
50  
65  
56  
40 10000 7000  
50 10000 7000  
60 10000 7000  
75 10000 7000  
100 10000 7000  
110 10000 7000  
120 10000 7000  
135 10000 7000  
160 10000 6500  
180 10000 6500  
195 10000 6500  
215 10000 6500  
250 10000 6500  
273 10000 6500  
60  
85  
70  
ERZV20D121 120(108 to 132)  
75  
100  
125  
170  
180  
200  
225  
270  
300  
320  
350  
385  
410  
450  
505  
560  
615  
670  
745  
825  
895  
1465  
85  
ERZV20D151  
150(135 to 165)  
95  
106  
140  
155  
168  
190  
228  
255  
275  
303  
350  
382  
382  
382  
382  
420  
460  
510  
565  
620  
1020  
ERZV20D201 200(185 to 225)  
ERZV20D221 220(198 to 242)  
ERZV20D241 240(216 to 264)  
ERZV20D271 270(247 to 303)  
ERZV20D331 330(297 to 363)  
ERZV20D361 360(324 to 396)  
ERZV20D391 390(351 to 429)  
ERZV20D431 430(387 to 473)  
ERZV20D471 470(423 to 517)  
130  
140  
150  
175  
210  
230  
250  
275  
300  
320  
350  
385  
420  
460  
510  
550  
625  
680  
1000  
ERZV20D511  
510(459 to 561)  
800  
ERZV20D561 560(504 to 616)  
ERZV20D621 620(558 to 682)  
ERZV20D681 680(612 to 748)  
ERZV20D751 750(675 to 825)  
ERZV20D821 820(738 to 902)  
ERZV20D911 910(819 to 1001)  
ERZV20D102 1000(900 to 1100)  
ERZV20D112 1100(990 to 1210)  
ERZV20D182 1800(1700 to 1980)  
273  
273  
273  
300  
325  
360  
400  
440  
720  
7500 6500  
7500 6500  
7500 6500  
7500 6500  
7500 6500  
7500 6500  
7500 6500  
7500 6500  
7500 6500  
750  
700  
650  
600  
530  
500  
450  
400  
250  
Ip Measuring current of clamping voltage 180 to 680 : 20 A, 820 to 182 : 100 A  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 21 –  
“ZNR” Transient/Surge Absorbers (Type D)  
Refer to page 24 to 26A about leads cut type and taping.  
Dimensions in mm (not to scale)  
D
Part No.  
D max.  
T max.  
W
1.0  
10.0  
H max.  
L
1.0  
1.5  
T
ERZV20D180  
ERZV20D220  
ERZV20D270  
ERZV20D330  
ERZV20D390  
ERZV20D470  
ERZV20D560  
ERZV20D680  
ERZV20D820  
ERZV20D101  
ERZV20D121  
ERZV20D151  
ERZV20D201  
ERZV20D221  
ERZV20D241  
ERZV20D271  
ERZV20D331  
ERZV20D361  
ERZV20D391  
ERZV20D431  
ERZV20D471  
ERZV20D511  
ERZV20D561  
ERZV20D621  
ERZV20D681  
ERZV20D751  
ERZV20D821  
ERZV20D911  
ERZV20D102  
ERZV20D112  
ERZV20D182  
2
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
21.5  
22.5  
22.5  
22.5  
22.5  
22.5  
22.5  
22.5  
22.5  
23.5  
5.1  
5.2  
5.3  
5.5  
5.5  
5.6  
5.7  
5.8  
4.9  
5.1  
5.3  
5.6  
5.2  
5.3  
5.4  
5.6  
5.9  
6.1  
6.2  
6.4  
6.6  
6.8  
7.1  
7.5  
7.8  
8.2  
8.5  
9.0  
9.5  
10.1  
14.8  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
24.5  
25.5  
25.5  
25.5  
25.5  
25.5  
25.5  
25.5  
25.5  
28.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
1.6  
1.7  
1.9  
1.9  
2.0  
2.1  
2.2  
1.8  
2.0  
2.2  
2.5  
2.1  
2.2  
2.3  
2.5  
2.8  
3.0  
3.1  
3.3  
3.5  
3.7  
4.2  
4.4  
4.7  
5.1  
5.4  
5.9  
6.4  
7.0  
L
W
f
1.0  
W
(ERZV20D182)  
D
T
L
f
1.0  
15.0  
10.7( 2.0)  
: W  
Typical Characteristics  
Voltage vs. Current  
(Relation between impulse  
Impulse Derating  
width and impulse current multiple)  
ERZV20D180 to ERZV20D680  
10000  
ERZV20D180 to ERZV20D680  
.BYꢀꢁ$MBNQJOHꢁ7PMUBHF  
.BYꢀ  
-FBLBHFꢁ$VSSFOU  
2 times : 5 min. interval  
400  
680  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
560  
470  
300  
390  
330  
200  
1000  
100  
10  
270  
220  
180  
100  
90  
80  
70  
60  
50  
680  
40  
560  
470  
30  
390  
330  
270  
20  
220  
180  
1
20  
100  
1000  
10000  
10  
9
Impulse Width (µs)  
Test current waveform  
8
10–6 to 10–3 A: Direct current  
10–1 to 104 A: 8/20 µs  
7
6
5
4
3
10–6 10–5  
10–4  
10–3  
10–2  
10–1  
100  
101  
102  
103  
104  
105  
Current (A)  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 22 –  
“ZNR” Transient/Surge Absorbers (Type D)  
(Relation between impulse  
width and impulse current multiple)  
Impulse Derating  
Typical Characteristics  
Voltage vs. Current  
ERZV20D820 to ERZV20D511  
ERZV20D820 to ERZV20D511  
10000  
2 times : 5 min. interval  
.BYꢀꢁ$MBNQJOHꢁ7PMUBHF  
.BYꢀ  
-FBLBHFꢁ$VSSFOU  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
2000  
511  
471  
431  
391  
361  
331  
471  
431  
391  
1000  
100  
361  
1000  
271  
241  
221  
201  
900  
800  
700  
600  
151  
121  
500  
400  
511  
10  
1
101  
820  
300  
271  
200  
20  
100  
1000  
10000  
Impulse Width (µs)  
201  
151  
100  
90  
80  
70  
60  
121  
101  
820  
ERZV20D561 to ERZV20D112  
10000  
2 times : 5 min. interval  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
50  
Test Current Waveform  
241  
331  
221  
10-6 to 10-3 A: Direct Current  
10-1 to 104 A: 8/20 µs  
40  
30  
1000  
100  
10-6  
10-5  
10-4  
10-3  
10-2  
10-1  
100  
101  
102  
103  
104  
105  
Current (A)  
ERZV20D561 to ERZV20D182  
10  
1
5000  
.BYꢀꢁ$MBNQJOHꢁ7PMUBHF  
.BYꢀ  
-FBLBHFꢁ$VSSFOU  
182  
4000  
112  
102  
911  
821  
751  
681  
621  
561  
3000  
2000  
102  
911  
821  
20  
100  
1000  
10000  
Impulse Width (µs)  
ERZV20D182  
10000  
182  
112  
2 times : 5 min. interval  
up to 10 times : 2 min. interval  
up to 106 times :10 sec. interval  
1000  
900  
800  
1000  
100  
700  
600  
500  
400  
300  
561  
10  
1
Test Current Waveform  
751  
681  
621  
10-6 to 10-3 A: Direct Current  
10-1 to 104 A: 8/20 µs  
200  
10-6  
10-5  
10-4  
10-3  
10-2  
10-1 100  
Current (A)  
101  
102  
103  
104  
105  
20  
100  
1000  
10000  
Impulse Width (µs)  
Design and specications are each subject to change without notice. Ask factory for the current technical specications before purchase and/or use.  
Should a safety concern arise regarding this product, please be sure to contact us immediately.  
01 Aug. 2012  
– 23 –  

相关型号:

V103

TRIPLE 10-BIT LVDS TRANSMITTER FOR VIDEO
ICSI

V103A

TRIPLE 10-BIT LVDS TRANSMITTER FOR VIDEO
ICSI

V103AYLF

TRIPLE 10-BIT LVDS TRANSMITTER FOR VIDEO
ICSI

V103AYLFT

TRIPLE 10-BIT LVDS TRANSMITTER FOR VIDEO
ICSI

V103YLF

TRIPLE 10-BIT LVDS TRANSMITTER FOR VIDEO
ICSI

V103YLFT

TRIPLE 10-BIT LVDS TRANSMITTER FOR VIDEO
ICSI

V104

10 BIT LVDS RECEIVER FOR VIDEO
ICSI

V104AJ236S10

x36 Fast Page Mode DRAM Module
ETC

V104AJ236S10L

x36 Fast Page Mode DRAM Module
ETC

V104AJ236S70

x36 Fast Page Mode DRAM Module
ETC

V104AJ236S70L

x36 Fast Page Mode DRAM Module
ETC

V104AJ236S80

x36 Fast Page Mode DRAM Module
ETC