VC20-4A-AC240V-N [PANASONIC]

Power/Signal Relay, 4PST, Momentary, 9200mW (Coil), AC Input, AC Output, Panel Mount;
VC20-4A-AC240V-N
型号: VC20-4A-AC240V-N
厂家: PANASONIC    PANASONIC
描述:

Power/Signal Relay, 4PST, Momentary, 9200mW (Coil), AC Input, AC Output, Panel Mount

继电器
文件: 总6页 (文件大小:897K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VDE  
HEAVY DUTY POWER  
RELAYS  
VC RELAYS  
• Using the VC mounting bracket  
saves even more time on  
installation and maintenance  
• Min. 250,000 faultless  
operations  
• UL recognized  
(File No. E112482: all models)  
cUL certified  
(File No. E112482: all models)  
TÜV certified  
(R9551921: all VC15 types)  
(R9551922: all VC20 types)  
FEATURES  
40  
VC power relays are designed  
52  
for controlling heavy duty  
loads safely:  
30  
34  
• Contact gap of 3 mm or more  
• 2-point contacts for circuits with  
high inrush current  
• Large insulation distance  
• Materials used in the terminal  
and the contact blocks are  
flame-retardant  
59  
56  
Faston terminal  
Reliable compact build:  
• Solenoid contact relays (AC  
type)  
• The lever mechanism and  
efficient electromagnet  
configuration allow for a  
substantially more compact  
size  
52  
34  
TYPICAL  
APPLICATIONS  
• Air-conditioner  
• Refrigerator  
• Freezer  
• Freeze dryer  
• Photocopier  
• Numeric control machine  
Textile machine  
• Elevator  
56  
• Quiet operation  
• Flexible mounting orientation  
(AC type) 80% of the rated  
voltage is guaranteed  
mm  
• Power tool  
Screw terminal  
SPECIFICATIONS  
Coil input (AC)  
Types  
VC15  
VC15S  
VC20  
VC20S  
4a, 3a1b,  
2a2b  
3a, 2a1b,  
4a, 3a1b  
2a,1a1b,1a  
Contact arrangement  
3a, 2a1b  
4a, 3a1b  
4a, 3a1b  
Maximum contact  
current  
"a” contact (p.f.=1)  
"b” contact (p.f.=1)  
15A  
3A  
#250 quick connector  
20A  
3A  
Terminals  
3.5 mm dia. screw  
#250 quick connector  
2.0 mm (AWG12)  
3.5 mm² (AWG12)  
4 mm dia. screw  
Single wire  
1.6 mm (AWG14)  
2.0 mm² (AWG14)  
Acceptable wire size  
Stranded wire  
1 phase, 120 V  
1 phase, 240 V  
3 phase, 240 V  
3 phase, 380 V  
1 phase, 120 V  
1 phase, 240 V  
3 phase, 240 V  
1 phase, 240 V  
0.4 kW (8A)  
UL, cUL 1/3HP  
UL, cUL 1HP  
UL, cUL 2HP  
0.75 kW (16A)  
UL, cUL 1HP  
UL, cUL 2HP  
UL, cUL 5HP  
Motor loads  
0.75 kW (8A)  
1.5 kW (8A)  
1.5 kW (4A)  
15A  
1.5 kW (16A)  
3.7 kW (16A)  
3.7 kW (8A)  
20A  
UL, cUL 15A  
UL, cUL 15A  
UL, cUL 15A  
UL, cUL 6A  
UL, cUL 20A  
UL, cUL 20A  
UL, cUL 20A  
UL, cUL 12A  
Resistive loads  
15A  
20A  
15A  
20A  
Tungsten, lamp loads  
Max. operating voltage  
Breaking capacity  
("a” contact)  
6A  
12A  
IEC 380V AC UL, cUL 300V AC  
3 phase, 240 V (p.f.=0.4)  
3 phase, 380 V (p.f.=0.4)  
3 phase, 240 V (p.f.=0.4)  
3 phase, 380 V (p.f.=0.4)  
80A  
40A  
80A  
40A  
160A  
80A  
Making capacity  
("a” contact)  
160A  
80A  
Electrical (max. rated current)  
Mechanical  
300,000 operations*  
1,000,000 operations  
Expected life  
Unit weight (with bracket)  
160g  
200g  
260g  
160g  
300g  
Applicable mounting bracket catalogue No.  
BW91543  
BW91543  
BW92043 BW91543  
BW92043  
ds_24401_0018_en_vc: 110607D  
1
VC  
Coil input (DC)  
Types  
VC15  
4a, 3a1b  
15A  
VC20  
2a, 1a1b  
20A  
Remarks  
Contact arrangement  
Maximum contact  
current  
"a” contact (p.f.=1)  
"b” contact (p.f.=1)  
3A  
3A  
Terminals  
#250 quick connector  
Single wire  
1.6 mm (AWG14)  
2.0 mm² (AWG14)  
2.0 mm (AWG12)  
3.5 mm² (AWG12)  
Acceptable wire size  
Stranded wire  
1 phase, 120 V  
1 phase, 240 V  
3 phase, 240 V  
3 phase, 380 V  
1 phase, 120 V  
1 phase, 240 V  
3 phase, 240 V  
1 phase, 240 V  
0.4 kW (8A)  
UL, cUL 1/3HP  
0.75 kW (16A)  
UL, cUL 1HP  
UL, cUL 2HP  
Motor loads  
0.75 kW (8A)  
1.5 kW (8A)  
1.5 kW (4A)  
15A  
UL, cUL 1HP  
UL, cUL 2HP  
1.5 kW (16A)  
UL, cUL 15A  
UL, cUL 15A  
UL, cUL 15A  
UL, cUL 6A  
20A  
20A  
UL, cUL 20A  
UL, cUL 20A  
Resistive loads  
15A  
15A  
Tungsten, lamp loads  
Max. operating voltage  
Breaking capacity  
("a” contact)  
6A  
12A  
UL, cUL 12A  
IEC 380V AC UL, cUL 300V AC  
3 phase, 240 V (p.f.=0.4)  
3 phase, 380 V (p.f.=0.4)  
3 phase, 240 V (p.f.=0.4)  
3 phase, 380 V (p.f.=0.4)  
80A  
40A  
80A  
40A  
IEC AC3  
IEC AC3  
Making capacity  
("a” contact)  
Electrical (max. rated current)  
Mechanical  
300,000 operations*  
1,000,000 operations  
Expected life  
Unit weight (with bracket)  
170g  
130g  
Applicable mounting bracket catalogue No.  
BW91543  
BW91543  
Note: *Except for 12 A of lamp loads. In this case the expected life is 100,000 operations.  
CONTACT ARRANGEMENTS  
No.of  
poles  
No.of  
poles  
No.of  
Type  
Contacts  
Contact Arrangements  
Type  
Contacts  
Contact Arrangements  
Type  
Contacts  
Contact Arrangements  
poles  
A1  
A2  
A1  
A2  
A1  
A2  
A1  
A2  
A1  
A2  
13  
23  
33  
43  
13  
23  
33  
43  
13  
14  
13  
23  
24  
23  
33  
34  
33  
34  
43  
44  
41  
42  
4a  
4a  
4a  
14  
13  
24  
23  
34  
33  
44  
41  
14  
13  
24  
23  
34  
33  
44  
41  
VC20  
VC20S  
4P  
3P  
VC15-DC  
4P  
A1  
A2  
A1  
A2  
3a1b  
3a  
3a1b  
2a2b  
3a  
3a1b  
2a  
4P  
14  
13  
14  
13  
14  
13  
24  
23  
24  
23  
24  
23  
24  
34  
33  
34  
31  
32  
42  
14  
13  
14  
13  
24  
23  
24  
23  
34  
42  
14  
13  
24  
23  
A1  
A2  
A1  
A2  
31  
32  
33  
41  
42  
VC15  
14  
13  
24  
21  
22  
2P  
VC20-DC  
A1  
A2  
A1  
A2  
A1  
A2  
A1  
A2  
2a1b  
2a  
1a1b  
14  
14  
13  
24  
23  
34  
31  
3P  
4P  
A1  
A2  
VC20  
2a1b  
4a  
14  
13  
14  
13  
24  
23  
32  
33  
2P  
1P  
A1  
A2  
A1  
A2  
A1  
A2  
A1  
A2  
31  
32  
43  
1a1b  
1a  
14  
13  
14  
13  
24  
23  
34  
33  
44  
41  
VC15S  
3a1b  
14  
14  
24  
34  
42  
Note: Inquire separately regarding TÜV certified models.  
2
ds_24401_0018_en_vc: 110607D  
VC  
COIL DATA (at 20°C)  
AC coils (EX. 240V AC)  
VC20  
(2a, 1a1b, 1a)  
VC15, VC15S,  
VC20 (3a, 2a1b)  
VC20 (4a, 3a1b),  
VC20S  
Types  
Nominal coil voltage  
Frequency, Hz  
240V AC  
240V AC  
240V AC  
60  
50  
80.8  
19.4  
26.7  
6.4  
60  
50  
104  
25  
60  
50  
146  
35  
mA  
VA  
mA  
VA  
67.5  
16.2  
22.5  
5.4  
87.5  
21  
133  
32  
Inrush  
Coil input  
(max.)  
25  
30  
32.5  
7.8  
192  
48  
38.3  
9.2  
192  
48  
Sealed  
6
7.2  
192  
48  
Pick-up voltage, V AC (max.) Cold  
Drop-out voltage, V AC (min.)  
192  
48  
192  
48  
192  
48  
DC coils (24V DC)  
Types  
VC15 (4a, 3a1b)  
24V DC  
3.3W  
VC20 (2a, 1a1b)  
24V DC  
3.3W  
Nominal coil voltage  
Coil capacity (±10%)  
Pick-up voltage, V DC (max.) Cold  
Drop-out voltage, V DC (min.)  
19.2  
19.2  
2.4  
2.4  
CHARACTERISTICS (AC, DC common)  
25ms*  
25ms  
Average 5 ms or less  
Max. operate time  
Max. release time  
Contact bounce time  
Switching speed  
Electrical  
1,200 times/hour  
14,400 times/hour  
Mechanical  
Dielectric strength  
-10 C to +40 C (max. 85% R.H.)  
Ambient temp. (max. humidity)  
2,500 Vrms (Initial)  
2,500 Vrms (Initial)  
Between open contacts  
(inc. coil terminal)  
+40 C to +55 C (max. 75% R.H.)  
Between load & source  
with open contacts  
Insulation resistance  
Between open contacts  
(inc. coil terminal)  
Between load & source  
with open contacts  
Over 100 MΩ (initial) at 500 V DC  
Over 100 MΩ (initial) at 500 V DC  
Remark: *VC15 DC type: 30 ms.  
ORDERING INFORMATION  
Ex. VC15  
S
4a  
AC240V  
N
Terminal type  
Contact arrangements*  
Coil voltage  
Nil: Faston terminal  
(Quick connection)  
S: Screw terminal  
(only for 4a or 3a1b  
of AC coil types)  
4a,3a1b,2a2b,  
3a,2a1b,  
2a,1a1b,  
1a  
AC 24V  
AC 48V  
DC 12V  
DC 24V  
AC 110V DC 48V  
AC 120V DC 100V  
AC 220V  
Note:  
*As to combination availability  
of contact arrangements, refer to  
contact arrangements in the  
specifications table.  
AC 240V  
etc.  
TYPES  
AC coils (EX. 240V AC)  
Types  
VC15  
Contact  
VC15S  
VC20  
VC20-4a-AC240V-N  
VC20S  
arrangements  
4a  
3a1b  
2a2b  
3a  
VC15-4a-AC240V-N  
VC15S-4a-AC240V-N  
VC20S-4a-AC240V-N  
VC15-3a1b-AC240V-N VC15S-3a1b-AC240V-N VC20-3a1b-AC240V-N VC20S-3a1b-AC240V-N  
4P  
3P  
̆
̆
̆
̆
̆
̆
̆
̆
̆
̆
̆
̆
̆
VC15-2a2b-AC240V-N  
VC15-3a-AC240V-N  
VC20-3a-AC240V-K-N  
VC20-2a1b-AC240V-N  
VC20-2a-AC240V-N  
VC20-1a1b-AC240V-N  
VC20-1a-AC240V-N  
2a1b  
2a  
VC15-2a1b-AC240V-N  
̆
̆
̆
2P  
1P  
1a1b  
1a  
ds_24401_0018_en_vc: 110607D  
3
VC  
DC coils (EX. 24V DC)  
Types  
Contact  
VC15  
VC20  
arrangements  
VC15-4a-DC24V-N  
4a  
3a1b  
2a  
̆
4P  
2P  
VC15-3a1b-DC24V-N  
̆
̆
VC20-2a-DC24V-N  
VC20-1a1b-DC24V-N  
̆
1a1b  
DIMENSIONS  
AC type  
mm  
VC15 / VC20  
VC154P㧕  
VC15S4P㧕  
52  
2.5  
52  
2.5  
52  
2.5  
9.9  
33  
31  
33  
31  
43  
41  
A1  
A2  
13  
14  
23  
24  
A
1
13  
14  
23  
24  
13  
14  
23  
24  
33  
34  
43/41  
44/42  
A1  
A2  
34  
32  
34  
32  
44  
42  
A2  
Terminal screw M3.5  
6.8 9.5 9.5 9.5 11.5  
7.3 12.5 12.5 14.5  
6.35  
AMP 250 series tab  
6.35  
AMP 250 series tab  
VC204P㧕  
VC20S4P㧕  
60  
2
2
60  
13  
14  
23  
24  
33 43/41 A1  
34 44/42 A2  
13  
14  
23  
24  
33  
34  
43/41 A1  
44/42 A2  
Terminal screw M3.5  
11.3  
7
11.5 11.5 11.5 13.5  
6.35  
AMP 250 series tab  
50㧕  
Mounting brackets  
BW91543 (BW92043)  
(included in delivered set)  
45  
2-  
φ5 mm dia.  
(mounting holes)  
35  
(Midway between  
mounting holes)  
Mounting bracket  
BW91543  
Suitable VC relay  
12  
VC15(3P)  
VC15S(4P)  
VC20(4P)  
VC15(4P)  
VC20(3P)  
VC20(2P)  
BW92043  
VC20(4P)  
VC20S(4P)  
Dimensions for the BW9204  
are given in parentheses ( ).  
φ3.5 mm dia. hole  
mm  
DC type  
VC20  
52  
9.5 9.5 9.5  
2.7  
VC15  
5
11.5  
40  
43  
41  
13  
23  
24  
33  
A  
23  
21  
A  
A㧞  
13  
14  
44  
42  
14  
34  
A2  
24  
22  
2.5  
16.5  
6.5  
12.5  
14  
0.8  
AMP 250 series tab  
6.35  
0.8  
AMP 250 series tab  
6.35  
Nameplate mounting position  
Nameplate mounting position  
35  
4
ds_24401_0018_en_vc: 110607D  
VC  
CAUTIONS FOR USE  
General Usage Conditions  
• Avoid using relays in extreme  
VC15(4P) should not be used with a  
• Ambient temperature (relative  
humidity):  
–10C°–40C° (45%–85% RH)  
40C°–55C° (45%–75% RH)  
(No condensation or freezing)  
• Elevation: 2,000 m or less  
• Operating circuit voltage fluctuation  
range:  
environments, such as locations subject  
to excessive heat, humidity, dust,  
corrosive gases, vibrations, mechanical  
shocks, or direct sunlight.  
• Avoid using relays in locations where  
they could be exposed to rain or water  
spray. (Such conditions could cause  
malfunctions.)  
• As shown in Figure 1, secure the ends  
of the mounting plate to the mounting  
bracket using 4 mm screws, then snap  
the relay into place. To remove the  
relay, carefully pry loose the hook of the  
mounting bracket with the tip of a  
screwdriver, as shown in Figure 2, and  
then pull the relay out. (Do not to apply  
too much force with the screwdriver to  
receptacle tab because the insulation  
distance cannot be guaranteed.  
3) Insert the receptacle firmly to prevent it  
from loosening. Removal requires a  
pulling force of 2 to 4 kg, so avoid trying  
to remove two at the same time. Make  
sure to remove only one at a time.  
4) Avoid applying solder to terminals.  
Figure 5  
80%–110% of rated voltage (cold state)  
• Rated frequency: 50/60 Hz  
Notes on relay selection  
• Select a relay such that the load  
capacity is within the rating of the  
solenoid switch.  
• At the maximum rated motor capacity,  
the product has an electrical switching  
durability (service life) of 250,000  
operations or more. This is suitable for  
consumer and light industrial  
Straight type  
Flag type Receptacle tab  
combined type  
Model  
VC15  
AMP 250 series receptacle  
Straight type, flag type,  
receptacle tab combined type  
Straight type, flag type,  
VC20  
receptacle tab combined type  
Straight type, flag type  
VC154Pꢁ  
VC204P  
avoid bending the mounting bracket.)  
Figure 1 Mounting bracket  
Straight type, flag type,  
receptacle tab combined type  
Figure 6  
6.35  
applications.  
0.8  
• In certain usage environments  
(temperature, humidity, oil mist, etc.),  
the service life of the contacts may be  
shortened. For applications such as  
industrial machinery where the usage  
environment is poor, select a model that  
provides some performance margin.  
Contact your National dealer for  
assistance when making a selection.  
• These relays are not suitable for  
applications such as inching or  
plugging.  
• Using the wrong coil voltage can cause  
the coil to burn out. Particular care  
should be taken when selecting the coil  
voltage in cases where the main circuit  
and operating circuit have different  
voltages.  
• When choosing a thermal relay, make  
sure the current adjustment range is  
appropriate for the full load current of  
the motor, regardless of the voltage of  
the main circuit. Operation cannot be  
guaranteed if the motor is outside the  
current adjustment range.  
• The relays are sealed type units and are  
adjusted at the factory. They are not  
intended to be disassembled by the  
user. It is not possible to replace  
individual contacts or coils.  
• The minimum usable current is the  
approximate lower limit value at which  
switching operation is possible at very  
small load levels. The actual minimum  
usable current may differ depending on  
factors such as the usage environment.  
Relays should therefore be tested at the  
actual load level before use.  
Installation notes  
Mounting  
• Mechanical shocks from being dropped,  
etc., can cause malfunctions. Handle  
relays with care.  
Mounting holes  
Figure 2  
• When relays are mounted side-by-side  
horizontally, the operation indicators are  
located on the side. Therefore, they  
should be positioned at least 5 mm  
apart, as shown in Figure 3. In addition,  
when they are mounted side-by-side  
vertically, as shown in Figure 4, make  
sure to leave sufficient space in  
between them to allow insertion of a  
screwdriver to remove the mounting  
brackets.  
Usage precautions  
• If there is concern that contact problems  
(fusing, open-phase, etc.) or the auto-  
reset operation of thermal relays could  
cause secondary damage, appropriate  
safeguards should be built into the  
system.  
• Make sure not to confuse the terminal  
positions when using relays. The  
terminals are marked on the nameplate.  
Be particularly careful regarding the  
positions of terminal b and the coil  
terminal.  
• Circuits through which current is flowing  
continuously for long periods due to the  
operation of the relay, etc., should be  
designed so that they are in a non-  
excited state when left idle. (Examples  
include circuits for emergency lamps,  
warning devices, and fault detectors  
that reset only in case of emergency  
and use terminal b to issue warnings.)  
Maintenance and inspection  
• Due to the danger of electric shock,  
always shut off power when performing  
maintenance or inspections.  
• Periodically retighten terminal screws to  
prevent the possibility of overheating or  
fire due to loosening.  
• If there is concern that contact problems  
(fusing, open-phase, etc.) could cause  
secondary damage, perform checks  
regularly and replace relays as soon as  
any problems are discovered.  
• If a thermal relay is tripped, correct the  
problem and then lightly press the reset  
button to restart operation.  
Figure 3  
7.5  
5
10  
Figure 4  
Wiring connections  
• Connections to screw terminals  
Terminal  
dimensions  
Terminal Max. conne- Suitable crimp- Standard tighten-  
screw  
ction wire  
type terminal  
ing torque  
Up terminal  
φ 1.6  
2-3.5  
2Y-3.5  
0.8-1.2N • m  
8.2-12.2kgf cmꢁ  
2
2 mm  
7.4  
M3.5  
Full-up terminal  
φ 2  
1.2-1.8N • m  
12.2-18.3kgf • cm㧕  
3.5-4  
2
3.5mm  
8.6  
M4  
• Plug-in terminal connections  
1) When removing a VC relay from the  
socket, pull it straight out. Pulling the  
relay out at an angle could bend the  
plug-in terminals.  
2) The receptacles listed in the table  
below may be used with relays having  
plug-in terminals. However, the  
ds_24401_0018_en_vc: 110607D  
5
VC  
APPLICATION NOTES  
Wiring  
:VC relay  
1. Air-conditioner  
Outdoor control unit  
Inverter unit  
Indoor control unit  
Power relay  
Power switch  
Short-circuit relay  
Compressor  
AC 200V  
Terminal  
block  
Compact power relay  
for internal frequency  
switching (JY)1-3 pcs. used  
Heater relay  
Solenoid valve  
selector switch  
Power relay  
Indoor fan  
switching relay  
Ry  
Relay Relay  
2
Heater  
(3-4 pcs.)  
F
Outdoor fan  
■ Features  
Outdoor fan switching  
relays (2 pcs.)  
Ry  
3
VC relays were developed for  
Ry 4-1  
Indoor unit (1)  
Ry 4-2  
Liquid side  
Relay  
Relay  
SVL  
use in air-conditioners.  
Terminal block  
solenoid valve  
Fan  
Ry  
1
SVG  
SVL  
SVO  
Gas side  
solenoid valve  
output  
Used for switching the  
terminal  
Indoor unit (2)  
Terminal block  
Indoor fan  
compressor and fan ON and OFF.  
Relay  
Relay  
Also used in commercial  
RV  
Four-way valve  
Release  
solenoid valve  
air-conditioners having separate  
indoor and outdoor units.  
SVR  
VC20-AC type is recommended.  
2. Freezer/Refrigerator  
Wiring  
:VC relay  
Earth leakage  
breaker  
MCB  
Thermistor  
Fluorescent  
lamp  
Power  
switch  
T
Defrost  
Fluorescent  
lamp  
Ry1  
Reset switch  
Ry2  
timer  
T
Timer  
Solenoid  
valve  
switch  
Ry1  
Ry2  
Thermal  
switch  
Defrost  
■ Features  
heater relay  
C
Used as relays for compressor  
Defrost heater  
Compressor  
starting.  
VC20-AC type is recommended.  
Wiring  
:VC relay  
3. Photo copy machine  
EX.)VC15-4a-DC type used  
a1  
a2  
10-15A (Lamp load)  
2A (Motor load)  
a3  
M
L
10㧑  
■ Features  
15㧑  
Main interlocking SW  
IEC standards emphasize safety  
and may require a contact gap  
of at least 4 mm.  
a4  
Note: Inquire separately when a contact gap  
of 4 mm or larger is required.  
Used as power relays of the  
main circuit.  
VC15-DC type is recommended.  
6
ds_24401_0018_en_vc: 110607D  

相关型号:

VC20-SERIES

Peripheral IC
ETC

VC2010

Controller Miscellaneous - Datasheet Reference
ETC

VC2010R0050BB

Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY

VC2010R0050DB

Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY

VC2010R0050FB

Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY

VC2010R0050GB

Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY

VC2010R0050JB

Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY

VC201T0R0050BB

Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY

VC201T0R0050DB

Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY

VC201T0R0050FB

Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY

VC201T0R0050GB

Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY

VC201T0R0050JB

Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY