VC20-4A-AC240V-N [PANASONIC]
Power/Signal Relay, 4PST, Momentary, 9200mW (Coil), AC Input, AC Output, Panel Mount;型号: | VC20-4A-AC240V-N |
厂家: | PANASONIC |
描述: | Power/Signal Relay, 4PST, Momentary, 9200mW (Coil), AC Input, AC Output, Panel Mount 继电器 |
文件: | 总6页 (文件大小:897K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
VDE
HEAVY DUTY POWER
RELAYS
VC RELAYS
• Using the VC mounting bracket
saves even more time on
installation and maintenance
• Min. 250,000 faultless
operations
• UL recognized
(File No. E112482: all models)
cUL certified
(File No. E112482: all models)
TÜV certified
(R9551921: all VC15 types)
(R9551922: all VC20 types)
FEATURES
40
VC power relays are designed
52
for controlling heavy duty
loads safely:
30
34
• Contact gap of 3 mm or more
• 2-point contacts for circuits with
high inrush current
• Large insulation distance
• Materials used in the terminal
and the contact blocks are
flame-retardant
59
56
Faston terminal
Reliable compact build:
• Solenoid contact relays (AC
type)
• The lever mechanism and
efficient electromagnet
configuration allow for a
substantially more compact
size
52
34
TYPICAL
APPLICATIONS
• Air-conditioner
• Refrigerator
• Freezer
• Freeze dryer
• Photocopier
• Numeric control machine
• Textile machine
• Elevator
56
• Quiet operation
• Flexible mounting orientation
(AC type) → 80% of the rated
voltage is guaranteed
mm
• Power tool
Screw terminal
SPECIFICATIONS
Coil input (AC)
Types
VC15
VC15S
VC20
VC20S
4a, 3a1b,
2a2b
3a, 2a1b,
4a, 3a1b
2a,1a1b,1a
Contact arrangement
3a, 2a1b
4a, 3a1b
4a, 3a1b
Maximum contact
current
"a” contact (p.f.=1)
"b” contact (p.f.=1)
15A
3A
#250 quick connector
20A
3A
Terminals
3.5 mm dia. screw
#250 quick connector
2.0 mm (AWG12)
3.5 mm² (AWG12)
4 mm dia. screw
Single wire
1.6 mm (AWG14)
2.0 mm² (AWG14)
Acceptable wire size
Stranded wire
1 phase, 120 V
1 phase, 240 V
3 phase, 240 V
3 phase, 380 V
1 phase, 120 V
1 phase, 240 V
3 phase, 240 V
1 phase, 240 V
0.4 kW (8A)
UL, cUL 1/3HP
UL, cUL 1HP
UL, cUL 2HP
0.75 kW (16A)
UL, cUL 1HP
UL, cUL 2HP
UL, cUL 5HP
Motor loads
0.75 kW (8A)
1.5 kW (8A)
1.5 kW (4A)
15A
1.5 kW (16A)
3.7 kW (16A)
3.7 kW (8A)
20A
UL, cUL 15A
UL, cUL 15A
UL, cUL 15A
UL, cUL 6A
UL, cUL 20A
UL, cUL 20A
UL, cUL 20A
UL, cUL 12A
Resistive loads
15A
20A
15A
20A
Tungsten, lamp loads
Max. operating voltage
Breaking capacity
("a” contact)
6A
12A
IEC 380V AC UL, cUL 300V AC
3 phase, 240 V (p.f.=0.4)
3 phase, 380 V (p.f.=0.4)
3 phase, 240 V (p.f.=0.4)
3 phase, 380 V (p.f.=0.4)
80A
40A
80A
40A
160A
80A
Making capacity
("a” contact)
160A
80A
Electrical (max. rated current)
Mechanical
300,000 operations*
1,000,000 operations
Expected life
Unit weight (with bracket)
160g
200g
260g
160g
300g
Applicable mounting bracket catalogue No.
BW91543
BW91543
BW92043 BW91543
BW92043
ds_24401_0018_en_vc: 110607D
1
VC
Coil input (DC)
Types
VC15
4a, 3a1b
15A
VC20
2a, 1a1b
20A
Remarks
Contact arrangement
Maximum contact
current
"a” contact (p.f.=1)
"b” contact (p.f.=1)
3A
3A
Terminals
#250 quick connector
Single wire
1.6 mm (AWG14)
2.0 mm² (AWG14)
2.0 mm (AWG12)
3.5 mm² (AWG12)
Acceptable wire size
Stranded wire
1 phase, 120 V
1 phase, 240 V
3 phase, 240 V
3 phase, 380 V
1 phase, 120 V
1 phase, 240 V
3 phase, 240 V
1 phase, 240 V
0.4 kW (8A)
UL, cUL 1/3HP
0.75 kW (16A)
UL, cUL 1HP
UL, cUL 2HP
⎯
Motor loads
0.75 kW (8A)
1.5 kW (8A)
1.5 kW (4A)
15A
UL, cUL 1HP
UL, cUL 2HP
1.5 kW (16A)
⎯
⎯
⎯
UL, cUL 15A
UL, cUL 15A
UL, cUL 15A
UL, cUL 6A
20A
20A
⎯
UL, cUL 20A
UL, cUL 20A
⎯
Resistive loads
15A
15A
Tungsten, lamp loads
Max. operating voltage
Breaking capacity
("a” contact)
6A
12A
UL, cUL 12A
IEC 380V AC UL, cUL 300V AC
3 phase, 240 V (p.f.=0.4)
3 phase, 380 V (p.f.=0.4)
3 phase, 240 V (p.f.=0.4)
3 phase, 380 V (p.f.=0.4)
80A
40A
80A
40A
⎯
⎯
⎯
⎯
IEC AC3
IEC AC3
Making capacity
("a” contact)
Electrical (max. rated current)
Mechanical
300,000 operations*
1,000,000 operations
Expected life
Unit weight (with bracket)
170g
130g
Applicable mounting bracket catalogue No.
BW91543
BW91543
Note: *Except for 12 A of lamp loads. In this case the expected life is 100,000 operations.
CONTACT ARRANGEMENTS
No.of
poles
No.of
poles
No.of
Type
Contacts
Contact Arrangements
Type
Contacts
Contact Arrangements
Type
Contacts
Contact Arrangements
poles
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
13
23
33
43
13
23
33
43
13
14
13
23
24
23
33
34
33
34
43
44
41
42
4a
4a
4a
14
13
24
23
34
33
44
41
14
13
24
23
34
33
44
41
VC20
VC20S
4P
3P
VC15-DC
4P
A1
A2
A1
A2
3a1b
3a
3a1b
2a2b
3a
3a1b
2a
4P
14
13
14
13
14
13
24
23
24
23
24
23
24
34
33
34
31
32
42
14
13
14
13
24
23
24
23
34
42
14
13
24
23
A1
A2
A1
A2
31
32
33
41
42
VC15
14
13
24
21
22
2P
VC20-DC
A1
A2
A1
A2
A1
A2
A1
A2
2a1b
2a
1a1b
14
14
13
24
23
34
31
3P
4P
A1
A2
VC20
2a1b
4a
14
13
14
13
24
23
32
33
2P
1P
A1
A2
A1
A2
A1
A2
A1
A2
31
32
43
1a1b
1a
14
13
14
13
24
23
34
33
44
41
VC15S
3a1b
14
14
24
34
42
Note: Inquire separately regarding TÜV certified models.
2
ds_24401_0018_en_vc: 110607D
VC
COIL DATA (at 20°C)
AC coils (EX. 240V AC)
VC20
(2a, 1a1b, 1a)
VC15, VC15S,
VC20 (3a, 2a1b)
VC20 (4a, 3a1b),
VC20S
Types
Nominal coil voltage
Frequency, Hz
240V AC
240V AC
240V AC
60
50
80.8
19.4
26.7
6.4
60
50
104
25
60
50
146
35
mA
VA
mA
VA
67.5
16.2
22.5
5.4
87.5
21
133
32
Inrush
Coil input
(max.)
25
30
32.5
7.8
192
48
38.3
9.2
192
48
Sealed
6
7.2
192
48
Pick-up voltage, V AC (max.) Cold
Drop-out voltage, V AC (min.)
192
48
192
48
192
48
DC coils (24V DC)
Types
VC15 (4a, 3a1b)
24V DC
3.3W
VC20 (2a, 1a1b)
24V DC
3.3W
Nominal coil voltage
Coil capacity (±10%)
Pick-up voltage, V DC (max.) Cold
Drop-out voltage, V DC (min.)
19.2
19.2
2.4
2.4
CHARACTERISTICS (AC, DC common)
25ms*
25ms
Average 5 ms or less
Max. operate time
Max. release time
Contact bounce time
Switching speed
Electrical
1,200 times/hour
14,400 times/hour
Mechanical
㨫
㨫
㨫
㨫
Dielectric strength
-10 C to +40 C (max. 85% R.H.)
Ambient temp. (max. humidity)
2,500 Vrms (Initial)
2,500 Vrms (Initial)
Between open contacts
(inc. coil terminal)
+40 C to +55 C (max. 75% R.H.)
Between load & source
with open contacts
Insulation resistance
Between open contacts
(inc. coil terminal)
Between load & source
with open contacts
Over 100 MΩ (initial) at 500 V DC
Over 100 MΩ (initial) at 500 V DC
Remark: *VC15 DC type: 30 ms.
ORDERING INFORMATION
Ex. VC15
S
4a
AC240V
N
Terminal type
Contact arrangements*
Coil voltage
Nil: Faston terminal
(Quick connection)
S: Screw terminal
(only for 4a or 3a1b
of AC coil types)
4a,3a1b,2a2b,
3a,2a1b,
2a,1a1b,
1a
AC 24V
AC 48V
DC 12V
DC 24V
AC 110V DC 48V
AC 120V DC 100V
AC 220V
Note:
*As to combination availability
of contact arrangements, refer to
contact arrangements in the
specifications table.
AC 240V
etc.
TYPES
AC coils (EX. 240V AC)
Types
VC15
Contact
VC15S
VC20
VC20-4a-AC240V-N
VC20S
arrangements
4a
3a1b
2a2b
3a
VC15-4a-AC240V-N
VC15S-4a-AC240V-N
VC20S-4a-AC240V-N
VC15-3a1b-AC240V-N VC15S-3a1b-AC240V-N VC20-3a1b-AC240V-N VC20S-3a1b-AC240V-N
4P
3P
̆
̆
̆
̆
̆
̆
̆
̆
̆
̆
̆
̆
̆
VC15-2a2b-AC240V-N
VC15-3a-AC240V-N
VC20-3a-AC240V-K-N
VC20-2a1b-AC240V-N
VC20-2a-AC240V-N
VC20-1a1b-AC240V-N
VC20-1a-AC240V-N
2a1b
2a
VC15-2a1b-AC240V-N
̆
̆
̆
2P
1P
1a1b
1a
ds_24401_0018_en_vc: 110607D
3
VC
DC coils (EX. 24V DC)
Types
Contact
VC15
VC20
arrangements
VC15-4a-DC24V-N
4a
3a1b
2a
̆
4P
2P
VC15-3a1b-DC24V-N
̆
̆
VC20-2a-DC24V-N
VC20-1a1b-DC24V-N
̆
1a1b
DIMENSIONS
AC type
mm
VC15 / VC20
VC15㧔4P㧕
VC15S㧔4P㧕
52
2.5
52
2.5
52
2.5
9.9
33
31
33
31
43
41
A1
A2
13
14
23
24
A
1
13
14
23
24
13
14
23
24
33
34
43/41
44/42
A1
A2
34
32
34
32
44
42
A2
Terminal screw M3.5
6.8 9.5 9.5 9.5 11.5
7.3 12.5 12.5 14.5
6.35
AMP 250 series tab
6.35
AMP 250 series tab
VC20㧔4P㧕
VC20S㧔4P㧕
60
2
2
60
13
14
23
24
33 43/41 A1
34 44/42 A2
13
14
23
24
33
34
43/41 A1
44/42 A2
Terminal screw M3.5
11.3
7
11.5 11.5 11.5 13.5
6.35
AMP 250 series tab
ꢀ50㧕
Mounting brackets
BW91543 (BW92043)
(included in delivered set)
45
2-
φ5 mm dia.
(mounting holes)
35
(Midway between
mounting holes)
Mounting bracket
BW91543
Suitable VC relay
12
VC15(3P)
VC15S(4P)
VC20(4P)
VC15(4P)
VC20(3P)
VC20(2P)
BW92043
VC20(4P)
VC20S(4P)
Dimensions for the BW9204
are given in parentheses ( ).
φ3.5 mm dia. hole
mm
DC type
VC20
52
9.5 9.5 9.5
2.7
VC15
5
11.5
40
43
41
13
23
24
33
A㧝
23
21
A㧝
A㧞
13
14
44
42
14
34
A2
24
22
2.5
16.5
6.5
12.5
14
0.8
AMP 250 series tab
6.35
0.8
AMP 250 series tab
6.35
Nameplate mounting position
Nameplate mounting position
35
4
ds_24401_0018_en_vc: 110607D
VC
CAUTIONS FOR USE
General Usage Conditions
• Avoid using relays in extreme
VC15(4P) should not be used with a
• Ambient temperature (relative
humidity):
–10C°–40C° (45%–85% RH)
40C°–55C° (45%–75% RH)
(No condensation or freezing)
• Elevation: 2,000 m or less
• Operating circuit voltage fluctuation
range:
environments, such as locations subject
to excessive heat, humidity, dust,
corrosive gases, vibrations, mechanical
shocks, or direct sunlight.
• Avoid using relays in locations where
they could be exposed to rain or water
spray. (Such conditions could cause
malfunctions.)
• As shown in Figure 1, secure the ends
of the mounting plate to the mounting
bracket using 4 mm screws, then snap
the relay into place. To remove the
relay, carefully pry loose the hook of the
mounting bracket with the tip of a
screwdriver, as shown in Figure 2, and
then pull the relay out. (Do not to apply
too much force with the screwdriver to
receptacle tab because the insulation
distance cannot be guaranteed.
3) Insert the receptacle firmly to prevent it
from loosening. Removal requires a
pulling force of 2 to 4 kg, so avoid trying
to remove two at the same time. Make
sure to remove only one at a time.
4) Avoid applying solder to terminals.
Figure 5
80%–110% of rated voltage (cold state)
• Rated frequency: 50/60 Hz
Notes on relay selection
• Select a relay such that the load
capacity is within the rating of the
solenoid switch.
• At the maximum rated motor capacity,
the product has an electrical switching
durability (service life) of 250,000
operations or more. This is suitable for
consumer and light industrial
Straight type
Flag type Receptacle tab
combined type
Model
VC15
AMP 250 series receptacle
Straight type, flag type,
receptacle tab combined type
Straight type, flag type,
VC20
receptacle tab combined type
Straight type, flag type
VC15ꢀ4Pꢁ
VC20ꢀ4P
avoid bending the mounting bracket.)
Figure 1 Mounting bracket
Straight type, flag type,
receptacle tab combined type
Figure 6
6.35
applications.
0.8
• In certain usage environments
(temperature, humidity, oil mist, etc.),
the service life of the contacts may be
shortened. For applications such as
industrial machinery where the usage
environment is poor, select a model that
provides some performance margin.
Contact your National dealer for
assistance when making a selection.
• These relays are not suitable for
applications such as inching or
plugging.
• Using the wrong coil voltage can cause
the coil to burn out. Particular care
should be taken when selecting the coil
voltage in cases where the main circuit
and operating circuit have different
voltages.
• When choosing a thermal relay, make
sure the current adjustment range is
appropriate for the full load current of
the motor, regardless of the voltage of
the main circuit. Operation cannot be
guaranteed if the motor is outside the
current adjustment range.
• The relays are sealed type units and are
adjusted at the factory. They are not
intended to be disassembled by the
user. It is not possible to replace
individual contacts or coils.
• The minimum usable current is the
approximate lower limit value at which
switching operation is possible at very
small load levels. The actual minimum
usable current may differ depending on
factors such as the usage environment.
Relays should therefore be tested at the
actual load level before use.
Installation notes
Mounting
• Mechanical shocks from being dropped,
etc., can cause malfunctions. Handle
relays with care.
Mounting holes
Figure 2
• When relays are mounted side-by-side
horizontally, the operation indicators are
located on the side. Therefore, they
should be positioned at least 5 mm
apart, as shown in Figure 3. In addition,
when they are mounted side-by-side
vertically, as shown in Figure 4, make
sure to leave sufficient space in
between them to allow insertion of a
screwdriver to remove the mounting
brackets.
Usage precautions
• If there is concern that contact problems
(fusing, open-phase, etc.) or the auto-
reset operation of thermal relays could
cause secondary damage, appropriate
safeguards should be built into the
system.
• Make sure not to confuse the terminal
positions when using relays. The
terminals are marked on the nameplate.
Be particularly careful regarding the
positions of terminal b and the coil
terminal.
• Circuits through which current is flowing
continuously for long periods due to the
operation of the relay, etc., should be
designed so that they are in a non-
excited state when left idle. (Examples
include circuits for emergency lamps,
warning devices, and fault detectors
that reset only in case of emergency
and use terminal b to issue warnings.)
Maintenance and inspection
• Due to the danger of electric shock,
always shut off power when performing
maintenance or inspections.
• Periodically retighten terminal screws to
prevent the possibility of overheating or
fire due to loosening.
• If there is concern that contact problems
(fusing, open-phase, etc.) could cause
secondary damage, perform checks
regularly and replace relays as soon as
any problems are discovered.
• If a thermal relay is tripped, correct the
problem and then lightly press the reset
button to restart operation.
Figure 3
7.5
5
10
Figure 4
Wiring connections
• Connections to screw terminals
Terminal
dimensions
Terminal Max. conne- Suitable crimp- Standard tighten-
screw
ction wire
type terminal
ing torque
Up terminal
φ 1.6
2-3.5
2Y-3.5
0.8-1.2N • m
㧔8.2-12.2kgf •cmꢁ
2
2 mm
7.4
M3.5
Full-up terminal
φ 2
1.2-1.8N • m
㧔12.2-18.3kgf • cm㧕
3.5-4
2
3.5mm
8.6
M4
• Plug-in terminal connections
1) When removing a VC relay from the
socket, pull it straight out. Pulling the
relay out at an angle could bend the
plug-in terminals.
2) The receptacles listed in the table
below may be used with relays having
plug-in terminals. However, the
ds_24401_0018_en_vc: 110607D
5
VC
APPLICATION NOTES
●
Wiring
:VC relay
1. Air-conditioner
Outdoor control unit
Inverter unit
Indoor control unit
Power relay
Power switch
Short-circuit relay
Compressor
AC 200V
Terminal
block
Compact power relay
for internal frequency
switching (JY)1-3 pcs. used
Heater relay
Solenoid valve
selector switch
Power relay
Indoor fan
switching relay
Ry
Relay Relay
2
Heater
(3-4 pcs.)
F
Outdoor fan
■ Features
Outdoor fan switching
relays (2 pcs.)
Ry
3
●
VC relays were developed for
Ry 4-1
Indoor unit (1)
Ry 4-2
Liquid side
Relay
Relay
SVL
use in air-conditioners.
Terminal block
solenoid valve
Fan
Ry
1
SVG
SVL
SVO
Gas side
solenoid valve
output
●
Used for switching the
terminal
Indoor unit (2)
Terminal block
Indoor fan
compressor and fan ON and OFF.
Relay
Relay
●
Also used in commercial
RV
Four-way valve
Release
solenoid valve
air-conditioners having separate
indoor and outdoor units.
SVR
●
VC20-AC type is recommended.
●
2. Freezer/Refrigerator
Wiring
:VC relay
Earth leakage
breaker
MCB
Thermistor
Fluorescent
lamp
Power
switch
T
Defrost
Fluorescent
lamp
Ry1
Reset switch
Ry2
timer
T
Timer
Solenoid
valve
switch
Ry1
Ry2
Thermal
switch
Defrost
■ Features
heater relay
●
C
Used as relays for compressor
Defrost heater
Compressor
starting.
●
VC20-AC type is recommended.
●
Wiring
:VC relay
3. Photo copy machine
EX.)VC15-4a-DC type used
a1
a2
10-15A (Lamp load)
2A (Motor load)
a3
M
L
㧗10㧑
䵊
■ Features
㧙15㧑
Main interlocking SW
●
IEC standards emphasize safety
and may require a contact gap
of at least 4 mm.
a4
Note: Inquire separately when a contact gap
of 4 mm or larger is required.
●
Used as power relays of the
main circuit.
●
VC15-DC type is recommended.
6
ds_24401_0018_en_vc: 110607D
相关型号:
VC2010R0050BB
Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY
VC2010R0050DB
Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY
VC2010R0050FB
Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY
VC2010R0050GB
Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY
VC2010R0050JB
Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY
VC201T0R0050BB
Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY
VC201T0R0050DB
Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY
VC201T0R0050FB
Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY
VC201T0R0050GB
Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY
VC201T0R0050JB
Bulk Metal® Foil Technology Conformally Coated Precision Current Sensing Resistors with TCR of 5 ppm/°C and values down to 5 mΩ
VISHAY
©2020 ICPDF网 联系我们和版权申明