Mini-Com® TX6™ PLUS UTP Jack Modules
S P E C I F I C A T I O N S H E E T
s p e c i f i c a t i o n s
TX6™ PLUS UTP Copper
Category 6/Class E, 8-position, UTP jack module shall terminate 4-pair, 22 – 26 AWG,
100 ohm unshielded twisted pair cable and shall not require use of a punchdown tool.
UTP jack modules shall use a forward motion termination method to optimize
performance by maintaining cable pair geometry while eliminating conductor untwist.
The termination cap shall be color-coded white to designate Category 6 performance
and shall include a universal label coded for T568A and T568B wiring schemes.
Cabling Systems
Mini-Com® TX6™ PLUS
UTP Jack Modules
Jack module:
Shuttered jack
module:
CJ688TG*
CJH688TG*
CJUD688TG*
CJLR688TG*
Up/Down 45° angle
jack module:
t e c h n i c a l i n f o r m a t i o n
Category 6/Class
E channel and
component
Exceeds channel requirements of ANSI/TIA-568.2-D Category 6 and ISO 11801
Class E standards at swept frequencies 1 to 250 MHz
Exceeds component requirements of ANSI/TIA-568.2-D Category 6 and ISO
11801 Class E standards at swept frequencies 1 to 250 MHz
Left/Right 45° angle
jack module:
Tools and Accessories
Jack module
performance:
termination tool:
Wire snipping tool:
Wire stripping tool:
Clear dust cap:
Block out device:
Phone icons:
EGJT-1 or TGJT
CWST
FCC and
Meets ANSI/TIA-1096-A contacts plated with 50 microinches of gold for
superior performance
ANSI compliance:
CJAST
IEC compliance:
Meets IEC 60603-7 and IEC 60512-99-001
Compliant
MDC-C
PSL-DCJB-^^^
CIPIW-C+
CIDIW-C+
RoHS compliance:
Data icons:
PoE & PoH
compliance:
Rated for 2500 cycles with IEEE 802.3af / 802.3at and 802.3bt type 3
and type 4. Supports Power over HDBaseT up to 100 watts
*To designate color, add suffix: IW (Off White), replace
IW suffix with WH (White), EI (Electric Ivory), WH (White),
IG (International Gray), AW (Arctic White), BL (Black),
BU (Blue), RD (Red), YL (Yellow), GR (Green),
OR (Orange), VL (Violet), BR (Brown), GD (Gold), LB
(Light Blue), or PK (Pink).
UL rated:
UL 1863 (Use as communications circuit accessory)
UL 2043 (Suitable for use in air-handling spaces)
Operating
Temperature:
-10°C to 65°C (14°F to 149°F)
^^^To designate color other than Red, add suffix
Black (BL), Blue (BU), Yellow (YL), Green (GR),
Orange (OR), Off White (IW) or International Gray (IG)
at the end of the part number. 10/package.
Conductor
termination range:
Wire cap compatible with 22 – 26 AWG solid or stranded cable with conductor
insulation diameters of 0.060 in. max. and overall cable O.D. 0.200 in. to 0.330 in.
+To designate color other than IW (Off White),
replace IW with EI (Electric Ivory), IG (International Gray),
BL (Black), BU (Blue), RD (Red), YL (Yellow),
GR (Green), OR (Orange), or VL (Violet) in the part
number. 100/package.
k e y f e a t u r e s a n d b e n e f i t s
100% performance tested
Confidence that each jack module will deliver the critical electrical
Contact customer service for bulk packaged and/
or keyed jack modules and patch cords.
performance requirements
Utilizes enhanced
Optimizes performance by eliminating conductor untwist and reduces
installation time and expense
Giga-TX™ Technology
UTP jack modules snap in and out of all Mini-Com® Faceplates, Modular
Patch Panels and Surface Mount Boxes for easy moves, adds,
and changes
Modular
Individually serialized
RJ45 interface
Marked with quality control number for future traceability
Industry standard interface provides a quick and easy plug and play
connection to RJ45 patch cords; backwards compatible
Identification
Can be clearly identified with optional labels and icons for port identification
Angle termination
version available
Side opening allows cable to be terminated to the right or left side of the
jack module; ideal for installations that have minimal depth that may not
allow standard bend radius practices to be accommodated
Termination tools
(optional)
EGJT-1 termination tool ensures conductors are fully terminated by utilizing
a smooth forward motion without impact on critical internal components
for maximum reliability; TGJT termination tool ideal for high
volume installations
Block out device (optional)
Provides a simple and secure method to control access to data ports while
not in use
Shuttered version
(optional)
Integrated spring shuttered door keeps out dust and debris of unmated
RJ45 jack modules automatically
a p p l i c a t i o n s
Mini-Com® TX6™ PLUS UTP Jack Modules are a component of the TX6™ PLUS UTP Copper Cabling
System. This end-to-end system is interoperable and backwards compatible, providing design flexibility
to protect network investments well into the future. With certified performance to the ANSI/TIA-568.2-D
Category 6 and ISO 11801 Class E standards, this system is ideal for today's high performance workstation
applications. With certified performance to the ANSI/TIA-568.2-D Category 6 and ISO 11801 Class E
standards, these systems will support the following applications:
• Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ethernet)
• 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM
• Token Ring 4/16
• Digital video and broadband/baseband analog video
• Voice over Internet Protocol (VoIP)
www.panduit.com
Mini-Com® TX6™ PLUS UTP Jack Modules
t e s t r e s u l t s
Mechanical Test
Test Method
—
Measurement
Load (grams)
Typical Test Results
Normal Force
> 100
< 40
< 5
Vibration
IEC 512-6d
IEC 512-6c
IEC 512-9a
Circuit Resistance (mOhms)
Contact Disturbance (microseconds)
Circuit Resistance (mOhms)
Mating Force (N)
Shock
Durability
< 40
< 20
< 20
>20
Mating/Un-mating
IEC 512-13b
Un-mating Force (N)
IEC 352
Termination Cycles
Mating Cylces
Number of Cycles
IEC 60603-7
Number of plug insertions
> 2500
Electrical Test
Test Method
IEC 512-2a
IEC 512-4a
IEC 512-3a
Measurement
Resistance (mOhms)
1000 V, 1 minute
Typical Test Results
Low Level Circuit Resistance
Dielectric Withstand Voltage
Insulation Resistance
< 20
Passed
> 500
Resistance (MOhms)
Environmental Test
Temperature Life
Test Method
IEC 512-9b
IEC 512-11c
IEC 512-11d
IEC 512-11a
IEC 512-11g
Measurement
Typical Test Results
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
< 40
< 40
< 40
< 40
< 40
Humidity
Thermal Shock
Climatic Sequence
Flowing Mixed Gas Corrosion
0.71
(18.06)
0.62
(15.87)
Jack Module and
Standard Wire Cap
1.50
(38.15)
Jack Module
Shuttered Jack Module
Dimensions are in inches (Dimensions in parenthesis are metric)
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT US/CANADA
Phone: 800.777.3300
PANDUIT EUROPE LTD.
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
cs-ap@panduit.com
PANDUIT JAPAN
PANDUIT LATIN AMERICA
Guadalajara, Mexico
cs-la@panduit.com
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
cs-aus@panduit.com
Phone: 61.3.9794.9020
London, UK
Tokyo, Japan
cs-emea@panduit.com
Phone: 44.20.8601.7200
cs-japan@panduit.com
Phone: 81.3.6863.6000
Phone: 65.6305.7575
Phone: 52.33.3777.6000
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
For more information
©2019 Panduit Corp.
ALL RIGHTS RESERVED.
COSP317--WW-ENG
Replaces WW-COSP48
4/2019
Visit us at www.panduit.com
Contact Customer Service by email: cs@panduit.com
or by phone: 800.777.3300
相关型号:
©2020 ICPDF网 联系我们和版权申明