T45BIW10-A [PANDUIT]
Pan-Way® T-45 Surface Raceway System;型号: | T45BIW10-A |
厂家: | PANDUIT CORP. |
描述: | Pan-Way® T-45 Surface Raceway System |
文件: | 总3页 (文件大小:261K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
®
Pan-Way T-45 Surface Raceway System
S P E C I F I C A T I O N S H E E T
s p e c i f i c a t i o n s
Pan-Way ® T-45 Raceway
T-45 non-metallic multi-channel, two-piece, hinged cover design
surface raceway shall be used to route, protect, and conceal
data, voice, video, fiber optic and power cabling. The raceway
shall be listed as suitable for use in applications up to 600 volts
between conductors by Underwriters Laboratories, Inc. per
standard 5A, and by Canadian Standards Association, Inc.
per 22.2 no. 62.1-03, when screw secured and installed per
instructions. A full complement of fittings with a 1" minimum
bend radius compliant with TIA/EIA-568-B, must be available
as well as device brackets and junction boxes to install a variety
of communication and electrical devices. Divider walls must be
available to form separate channels in the multi-channel
raceway. An offset box shall be available, with versions for
“snap-on” as well as “screw mount” faceplates, for mounting the
power receptacle or the data receptacles outside of the raceway
channel. T-45 raceway will be manufactured from impact
resistant material with flammability rating of V-0. T-45 raceway
must be tamper resistant yet also allow access for moves, adds
and changes. T-45 raceway finish shall be pure color and will
resist scratches and dents and will not peel or corrode.
Raceway Base with adhesive
8 feet:
T45BIW8-A
10 feet:
T45BIW10-A
Raceway Base without adhesive
8 feet:
10 feet:
T45BIW8
T45BIW10
Raceway Cover
8 feet:
10 feet:
T45CIW8
T45CIW10
Divider walls
8 feet:
10 feet:
T45DW8
T45DW10
T-45 Raceway Fittings
Cover coupler
fitting:
T45CCIW-X
Outside corner
fitting:
T45OCIW
T45ICIW
t e c h n i c a l i n f o r m a t i o n
Inside corner
fitting:
Material:
Rigid PVC
Right angle
fitting:
Flammability:
Voltage rating:
Approvals:
NEC:
UL94V-0; FT4
T45RAIW
T45ECIW
UL-5A 600VAC; CSA C22.2 No. 62.1-03 600V
UL Listed 95425 (raceway); UL Listed E116129 (fittings)
Article 388
End cap fitting:
Entrance end
fitting:
T45EEIW
Bend radius
control fitting:
Color:
IW (Off White), EI (Electrical Ivory), WH (White) available in 8 foot
lengths only without adhesive
T45TRI
Reducer fitting:
Tee fitting:
T45RLDIW
T45TIW
CSI spec form:
LP-CSISPEC-T45-1
k e y f e a t u r e s a n d b e n e f i t s
Insert for tee
fitting:
T45TD
Unique size
Provides greater capacity in a smaller footprint allowing greater
flexibility to match the raceway to the application.
T-45 Raceway Accessories
Hinged data
bracket:
1"bend radius
control fittings
Meets TIA/EIA standard and many warranty requirements
T45HDBIW
Wire retainer:
T45WR-X
T45WCIW
T45WC2IW
T45HEBIW
Designer profile
Maintains the same aesthetically pleasing profile of Panduit® T-70,
Twin-70 and TG-70 Raceway which allows all four systems to work
together or independently
Workstation
Outlet Center™
Offset box:
Multi-directional hinge
Easy access from either side of the raceway provides more
convenience for moves, adds and changes; latch is tamper
resistant which provides maximum security for communication
cabling and maximum safety for power cabling
Workstation
Outlet Center™
Offset box:
Electrical bracket
and box for
duplex outlets:
Multi-channel capable
Capable of routing both power and communication cabling in a
single raceway
Multi-termination
options
Ability to create many different configurations using in-line termi-
nation features, offset boxes or certain Pan-Way surface mount
boxes.
Electrical bracket
and box for
rectangular
outlets:
T45HEGBIW
All parts listed in Off White (IW) color. To order
other colors substitute Electrical Ivory (EI) or
White (WH).
a p p l i c a t i o n s
Pan-Way® T-45 Non-Metallic Surface Raceway and Power Brackets, T-45 Offset Box and
is a multi-channel channel raceway which
provides solutions for routing low voltage,
fiber optic and/or power cabling along
perimeter walls. T-45 Surface Raceway
terminates using the T-45 Hinged Data
Pan-Way® Surface Mount Outlet Boxes and
superior Pan-Way® Snap-On Faceplates.
Fittings for T-45 are available to transition
to Pan-Way® LD Series Raceways.
www.panduit.com
®
Pan-Way T-45 Surface Raceway System
W i r e F i l l
T-45
Internal Area = 2.12 Sq. In.
Fiber Optic
Cable
Electrical Cables
14 12 10
Data Grade Cables
24 AWG
Coax Cables
AWG AWG AWG
24 AWG
24 AWG
24 AWG
Cat. 6
24 AWG
Cat. 6A
24 AWG
Cat. 6A
24 AWG
Cat. 5e -
Plenum
Cat. 5e -
Riser
THHN/THWN/T90
Cat. 6A
Cat. 6A (SD)
RG6
RG59/u
2 Strand
0.111 0.130 0.164 DIA = 0.193 DIA = 0.225 DIA = 0.240 DIA = 0.289 DIA = 0.300 DIA = 0.330 DIA = 0.240 DIA = 0.275 DIA = 0.242 DIA = 0.175
FILL FILL FILL FILL FILL FILL FILL FILL FILL FILL FILL
MAX MAX MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX
Raceway
Type and
Fill
Area
Configuration (in²) (UL Temp Rise Test) (40%) (60%) (40%) (60%) (40%) (60%) (40%) (60%) (40%) (60%) (40%) (60%) (40%) (60%) (40%) (60%) (40%) (60%) (40%) (60%)
T-45: No
2.13 36
27
27
25
25
29
23
43
35
21
17
32
25
18
15
28
22
12
10
19
15
12
9
18
14
9
8
14
12
18
15
28
22
14
11
21
17
18
14
27
22
35
28
53
42
Devices
T-45: No
Devices with 1.72 36
wire retainer
T-45: Power
0.44 12
11
–
8
–
–
–
–
–
–
–
–
7
–
–
6
–
–
5
–
8
–
–
–
8
–
–
–
–
–
& data with
wire retainer &
divider wall (2
1.20
–
16
24
12
18
10
15
10
10
10
15
12
10
15
19
29
channels)
T-45: Power & 0.44 12
11
–
8
–
6
9
9
4
6
6
3
6
5
9
2
4
4
6
2
3
3
5
2
3
3
4
3
6
5
9
2
4
4
6
3
5
5
8
7
10
16
data with wire
0.68
0.44
–
–
13
10
11
retainer & two
divider walls
(3 channels)
–
–
8
6
–
9
–
4
–
6
–
3
–
5
–
2
–
4
–
2
–
3
–
2
–
3
–
3
–
5
–
2
–
4
–
3
–
5
–
7
–
10
–
T-45: Power
and data
0.41 12
11
using the
Workstation
Outlet Center™
Offset Box
1.06
2.00
–
–
–
–
14
21
10
15
9
14
6
9
5
8
4
7
9
14
7
10
9
13
17
26
T-45: Data only
using data
bracket
–
–
8
27
–
41
–
20
–
30
–
17
–
26
–
12
–
18
–
11
–
16
–
9
–
14
–
17
–
26
–
13
–
20
–
17
–
26
–
33
–
49
–
T-45 Power
and Data
0.52 12
11
using Hinged
Data Bracket
with Divider
Insert
1.20
–
–
–
16
24
12
18
10
15
7
10
6
10
5
8
10
15
8
12
10
15
19
29
T-45: Power
and Data
Using
Electrical
Bracket and
Box
0.22
0.50
9
–
7
–
4
–
–
6
–
–
5
–
7
–
4
–
6
–
3
–
4
–
2
–
4
–
2
–
3
–
4
–
6
–
3
–
5
–
4
–
6
–
8
–
10
12
®
Pan-Way T-45 Surface Raceway System
T- 4 5 R a c e w a y
T45B
T45C
F i t t i n g s a n d A c c e s s o r i e s
T45CC**-X
T45OC
T45IC
T45RA
T45EC
T45EE
T45TRI
T45RLD
T45WC
T45TD
T45T
T45HDB
T45DW
T45WR-X
T45WC2
T45HEB
T45HEGB
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT CANADA
Markham, Ontario
cs-cdn@panduit.com
PANDUIT EUROPE LTD.
London, UK
PANDUIT SINGAPORE PTE. LTD.
PANDUIT JAPAN
Tokyo, Japan
PANDUIT LATIN AMERICA
Guadalajara, Mexico
cs-la@panduit.com
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
Republic of Singapore
cs-ap@panduit.com
Phone: 65.6305.7575
cs-emea@panduit.com
cs-japan@panduit.com
cs-aus@panduit.com
Phone: 800.777.3300 Phone: 44.20.8601.7200
Phone: 81.3.6863.6000 Phone: 52.33.3777.6000
Phone: 61.3.9794.9020
For a copy of Panduit product warranties, log on to www.panduit.com/warranty