EP501BL004W [PARALIGHT]

Long operating life.;
EP501BL004W
型号: EP501BL004W
厂家: PARA LIGHT ELECTRONICS CO., LTD.    PARA LIGHT ELECTRONICS CO., LTD.
描述:

Long operating life.

文件: 总12页 (文件大小:186K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Release by  
PARALIGHT DCC  
PARA LIGHT ELECTRONICS CO., LTD.  
4F, No.1, Lane 93, Chien Yi Road, Chung Ho City, Taipei, Taiwan  
Tel: 886-2-2225-3733  
E-mail: para@para.com.tw  
Fax: 886-2-2225-4800  
http://www.para.com.tw  
DATA SHEET  
PART NO. : EP501BL004W  
REV : A/3  
CUSTOMERS APPROVAL : _______________  
DCC : ____________  
Page : 1  
DRAWING NO. : DS-50-10-XXX DATE : 2012-7-3  
Release by  
PARALIGHT DCC  
Enhance Power LED  
EP501BL004W  
REV:A/3  
Package Dimension  
°
Note:  
1. All dimensions are in millimeters.  
2. Tolerance is ± 0.25mm (.010") unless otherwise noted.  
Features  
1. Long operating life.  
2. Low voltage DC operated.  
3. Instant light (Less than 100NS).  
4. RoHS Compliant.  
5. Compatible to assemble, lead free reflow soldering process.  
6. The led can withstand the max static level when assembling or operationHBM.  
DRAWING NO. : DS-50-10-XXX  
DATE : 2012-7-3  
Page : 2  
Release by  
PARALIGHT DCC  
Enhance Power LED  
EP501BL004W  
REV:A/3  
Chip Material  
1. Dice Material : InGaN  
2. Light Color : Blue  
3. Lens Color : Water Clear  
Absolute Maximum Rating(Ta=25)  
Symbol  
IF  
Parameter  
DC Forward Current  
Rating  
350  
Unit  
mA  
Peak Pulse Current  
Ipulse  
500  
mA  
(tp100us, duty cycle=0.25)  
Reverse Voltage  
VR  
IR  
5
50  
V
uA  
Reverse Current(VR=5V)  
LED Junction Temperature(at IF=350mA)  
Operating Temperature  
Tj  
115  
*Topr  
*Tstg  
Tsol  
ESD  
-30 ~ +100  
-40 ~ +100  
5
Storage Temperature  
Manual Soldering Time at 260(Max.)  
ESD SensitivityHuman Body Model)  
seconds  
V
2000  
Note :  
* : Temperature for using with aluminum board.  
Electro-Optical Characteristic(Ta=25, Topr=100ms)  
Parameter  
Luminous Flux  
Viewing Angle  
Dominant  
Symbol Min.  
ΦV  
Typ.  
15  
Max.  
Unit  
lm  
Test Condition  
IF=350mA  
2θ1/2  
130  
deg  
λd  
455  
470  
nm  
nm  
IF=350mA  
Wavelength  
Spectral Line  
Half-Width  
Δλ  
25  
Forward Voltage  
Reverse Current  
VF  
IR  
3.3  
3.6  
50  
V
IF =350mA  
VR = 5V  
μA  
DRAWING NO. : DS-50-10-XXX  
DATE : 2012-7-3  
Page : 3  
Release by  
PARALIGHT DCC  
Enhance Power LED  
EP501BL004W  
REV:A/3  
Typical Optical and Electrical  
1 0 0  
8 0  
6 0  
4 0  
2 0  
0
7 0 0  
8 0 0  
6 0 0  
1 0 0 0  
5 0 0  
4 0 0  
9 0 0  
Wavelength (nm)  
Relative Intensity VS Wavelength  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
150  
200  
250  
300  
350  
400  
100  
IF (mA)  
Forward Current VS Forward Voltage  
DRAWING NO. : DS-50-10-XXX  
DATE : 2012-7-3  
Page : 4  
Release by  
PARALIGHT DCC  
Enhance Power LED  
EP501BL004W  
REV:A/3  
Typical Optical and Electrical  
480  
475  
470  
465  
460  
455  
450  
350  
400  
300  
100  
150  
200  
250  
IF (mA)  
Forward Current VS Wavelength  
60  
50  
40  
30  
20  
10  
0
350  
400  
300  
100  
150  
200  
250  
IF (mA)  
Forward Current VS Luminous Flux  
DRAWING NO. : DS-50-10-XXX  
DATE : 2012-7-3  
Page : 5  
Release by  
PARALIGHT DCC  
Enhance Power LED  
EP501BL004W  
REV:A/3  
Typical Optical and Electrical  
typical polar radiation pattern for lambertian  
Bin Code List  
Luminous Flux (IV),(Unit: lm ,IF=350mA)  
Bin Code  
Min  
13  
17  
20  
23  
27  
33  
Max  
17  
20  
23  
27  
33  
39  
C
D
E
F
G
H
I
39  
45  
Including test tolerance ± 10%  
Forward Voltage(VF),(Unit: V, IF=350mA)  
Bin Code  
V8  
Min  
Max  
3.00  
3.20  
3.40  
3.60  
V9  
3.20  
V10  
3.40  
Including test tolerance±0.1V  
DRAWING NO. : DS-50-10-XXX  
DATE : 2012-7-3  
Page : 6  
Release by  
PARALIGHT DCC  
Enhance Power LED  
EP501BL004W  
REV:A/3  
Dominant Wavelength (Hue),(Unit: nm, IF=350mA)  
Bin Code  
B1  
Min  
455  
460  
465  
Max  
460  
465  
470  
B2  
B3  
Including±2nm test tolerance  
Label Explanation  
PART NO: EP501BL004W  
LOT NO:  
L E M 10 1 001  
A
B
C
D
E
F
A---L: Local  
F: Foreign  
B---E: E-power  
C---M: For series number  
D---Year  
E---Month  
F---Spec.  
BIN NO: Bin Code  
Caution  
(1).Handling note: Do not touch LEDs lens.  
DRAWING NO. : DS-50-10-XXX  
DATE : 2012-7-3  
Page : 7  
Release by  
PARALIGHT DCC  
Enhance Power LED  
EP501BL004W  
REV:A/3  
(2)Please wear anti-static wrist strap and gloves to prevent ESD damage when handling.  
Packing Specification  
-
+
15.50±0.20  
Cardboard A  
(50pcs*60tube=3000pcs)  
105  
105  
Cardboard B  
(3000pcs*6carton=18000pcs)  
490  
330  
250  
Note:  
1. All dimensions are in millimeters.  
2. Normal packing Quantity:3000pcs.  
3. The carton B contains 6 cartons A at maximum.  
DRAWING NO. : DS-50-10-XXX DATE : 2012-7-3  
Page : 8  
b
y
PD
Release by  
PARALIGHT DCC  
Enhance Power LED  
EP501BL004W  
REV: A/3  
Suggest Soldering Pad Dimension  
2 *1.50  
Solder Mask  
Solder Pad  
Heat slug indepedent to electrical contact.  
Apply heat-dissipating paste here  
2 *1.15  
Note:  
1. All dimensions are in millimeters.  
2. The drawings are not to scale.  
3. Solder pad can't be connected to slug.  
IR Reflow soldering profile for lead free soldering(J-STD-020C)  
s
t
DRAWING NO. : DS-50-10-XXX  
DATE : 2012-7-3  
Page : 9  
Release by  
PARALIGHT DCC  
Enhance Power LED  
EP501BL004W  
REV:A/3  
Storage  
1. Do not open the moisture proof bag before the devices are ready to use.  
2. Before the package is opened, LED should be stored at temperatures less than 30and  
humidity less than 50%.  
3. LED may be stored for 6 months. When the storage time has reached more than 6 months,  
LED should be stored in a sealed container filled with Nitrogen gas.  
4. After the package is opened, LED should be stored at temperatures less than 30and  
humidity less than 30%.  
5. LED should be used within 168 hours (7 days) after the package is opened.  
6. Before using LED, baking treatment should be implemented based on the following condition:  
pre-curing at 60±5for 24 hours.  
E-Power Operating Procedure  
1. E-power 350 series products should be operated at 350 mA for ideal performance, but not  
more than 350mA.  
2. E-power 350 series products must be used in conjunction with heat-sinking devices.  
Soldering on Al PCB with mid-connection point while keeping the layout  
pattern (19.9mm, thickness2.5mm) is another way to help heat dissipation. Thermal  
Resistance for aluminum board must be less than 0.65 /W.  
3. E-power 350 series products are sensitive to static. Operators must wear static wristband  
(wireless static wristband is prohibited) and be well grounded while working in the  
environment with an ionizing air blower. Anti-static requirement should be under ESD  
2000V.  
4. A non-conductive heat-dissipating paste should be applied between E-power and heat-sinking  
device.  
5. Sufficient thermal management must be applied.Large LED forward current will cause high  
junction temperature and reduce LED life.  
DRAWING NO. : DS-50-10-XXX  
DATE : 2012-7-3  
Page : 10  
Release by  
PARALIGHT DCC  
Enhance Power LED  
EP501BL004W  
REV:A/3  
Reliability Test  
Test Item  
Stress duration  
result  
number  
100pcs  
Test Condition  
No Failure  
3 times  
Reflow  
Tsol=260,10sec  
H:+100±5  
15mins  
L-40±5℃  
Temperature  
Cycle  
20pcs  
300 Cycles  
No Failure  
High  
Ta=85±5℃  
RH= 9095%  
IF=350mA  
Temperature  
High Humidity  
Operation  
20pcs  
500 hours  
1000hours  
No Failure  
High  
Temperature  
High Humidity  
Storage  
Ta:65±5℃  
RH:9095%RH  
20pcs  
No Failure  
Room  
Temperature  
Operation  
Ta= 25±5℃  
IF =350mA  
20pcs  
20pcs  
1000hours  
1000hours  
No Failure  
No Failure  
Low  
Temperature  
Operation  
Ta= -40±5℃  
IF=350mA  
High  
Temperature  
Operation  
Ta= 110±5℃  
IF=350mA  
20pcs  
20pcs  
1000hours  
48 hours  
No Failure  
No Failure  
Salt Spray  
Ta=35℃  
Temperature for using with aluminum board, in a good thermal-exchange surrounding.  
Failure Criteria:  
1. LED are open or shorted,  
2. Luminous flux attenuate difference(1000hours)30%,  
3. Forward voltage difference(1000hours) 20%.  
DRAWING NO. : DS-50-10-XXX  
DATE : 2012-7-3  
Page : 11  
Release by  
PARALIGHT DCC  
Enhance Power LED  
EP501BL004W  
REV:A/3  
Part NO. System of E-Power LED  
EP 5 01 B L 004 W  
Special markW:white, B:black  
Series Number  
View Angle:  
2: 2*5=10°  
3: 3*5=15°  
6 : 6*5=30°  
C: C*5=60°  
L: L*5=130°  
M: M*5=160°  
R:λd =625nm  
G:λd =525nm  
IR:λP =850nm  
W1: White  
Y:λd=590nm  
B:λd = 460nm  
A:λd =615nm  
WY: Warm white  
Power:  
011W033W055W,......  
0A-100W  
Slug material:  
1Al,2silicon,3Fe,4ceramic,  
5Cu  
EPEnhance Power  
DRAWING NO. : DS-50-10-XXX  
DATE : 2012-7-3  
Page : 12  

相关型号:

EP501GL007W

Long operating life.
PARALIGHT

EP501IR1L015W

Long operating life.
PARALIGHT

EP501RL003W

Long operating life.
PARALIGHT

EP501W1BW071W

Long operating life.
PARALIGHT

EP501W1C001WH

Long operating life.
PARALIGHT

EP501W1L001WS

Long operating life.
PARALIGHT

EP501W1L053WS

Long operating life.
PARALIGHT

EP501W1L056WHR2

Long operating life.
PARALIGHT

EP501W1L059WHR

Long operating life.
PARALIGHT

EP501W2L001W

Visible LED
PARALIGHT

EP501W2L001WL

Enhance Power LED
PARALIGHT

EP501W4L040WHR

Visible LED
PARALIGHT