PE3C0230-100CM [PASTERNACK]

SMA Male to SMA Male Low Loss Cable 100 cm Length Using PE-P142LL Coax with HeatShrink;
PE3C0230-100CM
型号: PE3C0230-100CM
厂家: Pasternack Enterprises, Inc.    Pasternack Enterprises, Inc.
描述:

SMA Male to SMA Male Low Loss Cable 100 cm Length Using PE-P142LL Coax with HeatShrink

文件: 总4页 (文件大小:414K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
N Male to N Male Low Loss Cable 50 cm Length  
Using PE-P142LL Coax with HeatShrink  
RF Cable Assemblies Technical Data Sheet  
PE3C0231-50CM  
Configuration  
• Connector 1: N Male  
• Connector 2: N Male  
• Cable Type: PE-P142LL  
Features  
• Passivated Stainless Steel Flexible Armoring  
• Type N Male to N Male and SMA Male to SMA Male Con-  
figurations Available  
0.195 (FEP)  
Robust Connector/Armor Interface  
0.320 (Stainless Steel)  
• Triple Shielded Low Loss PE-P142LL Coax with Expand-  
ed PTFE Tape Dielectric  
• Standard inch lengths: 24”, 36”, 48”, 60”, 72”, 120”  
• Standard metric lengths: 50cm, 100cm, 150cm, 200cm  
• SMA rated to 20 GHz with a 1.35:1 VSWR  
• N type rated to 18 GHz with a 1.35:1 VSWR  
Custom lengths available, call for pricing and lead time  
Applications  
General Purpose  
• Laboratory Use  
.
Description  
Pasternack’s new SMA and type N armored test cables utilize a flexible passivated stainless steel armoring that is designed  
to handle harsh industrial environments, common in production test systems. Its rugged armoring is very flexible and ensures  
RF signal integrity during test, even when exposed to a high traffic production environment. These armored RF test cables are  
equipped with passivated stainless steel connectors, with the SMA designed to operate to 20 GHz and the type N to 18 GHz.  
A robust mechanical connector/armoring interface increases the durability of the test cables, and its strain relief boot increases  
the life of the test cable. Pasternack’s armored test cables are built using PE-P142LL coaxial cable that is triple shielded with  
an expanded PTFE dielectric, guaranteeing low loss performance.  
Electrical Specifications  
Description  
Minimum  
Typical  
Maximum  
Units  
Frequency Range  
DC  
18  
GHz  
VSWR  
1.25:1  
1.35:1  
Velocity of Propagation  
80  
%
.
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,  
inventory and certifications: N Male to N Male Low Loss Cable 50 cm Length Using PE-P142LL Coax with HeatShrink  
PE3C0231-50CM  
PE3C0231-50CM REV 1.3  
1
N Male to N Male Low Loss Cable 50 cm Length  
Using PE-P142LL Coax with HeatShrink  
RF Cable Assemblies Technical Data Sheet  
PE3C0231-50CM  
Specifications by Frequency  
Description  
F1  
F2  
F3  
F4  
F5  
Units  
Frequency  
1
3
5
10  
18  
GHz  
Insertion Loss (Typ.)  
0.132  
0.23  
0.296  
0.411  
220  
0.591  
dB  
Power Handling (Max.)  
Watts  
.
Electrical Specification Notes:  
Insertion loss does not include the loss of the connectors.  
Insertion loss is estimated as 0.05 x sqrt(fGHz) dB per connector.  
Mechanical Specifications  
Cable Assembly  
Length*  
19.685 in [500 mm]  
0.19 lbs [86.18 g]  
.
Weight  
Cable  
Cable Type  
Impedance  
Inner Conductor Type  
Inner Conductor Material and Plating  
Dielectric Type  
PE-P142LL  
50 Ohms  
Solid  
Copper, Silver  
PTFE  
Number of Shields  
Shield Layer 1  
Shield Layer 2  
3
Silver Plated Copper Braid  
Aluminum Polyester  
Shield Layer 3  
Silver Plated Copper Braid  
Passivated Stainless Steel  
0.32 in [8.13 mm]  
Jacket Material  
Jacket Diameter  
.
Repeated Minimum Bend Radius  
1 in [25.4 mm]  
Connectors  
Description  
Connector 1  
Connector 2  
Type  
N Male  
50 Ohms  
N Male  
50 Ohms  
Impedance  
Contact Material and Plating  
Body Material and Plating  
Coupling Nut Material and Plating  
.
Brass, Gold  
Brass, Gold  
Passivated Stainless Steel  
Passivated Stainless Steel  
Passivated Stainless Steel  
Passivated Stainless Steel  
Mechanical Specification Notes:  
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,  
inventory and certifications: N Male to N Male Low Loss Cable 50 cm Length Using PE-P142LL Coax with HeatShrink  
PE3C0231-50CM  
PE3C0231-50CM REV 1.3  
2
N Male to N Male Low Loss Cable 50 cm Length  
Using PE-P142LL Coax with HeatShrink  
RF Cable Assemblies Technical Data Sheet  
PE3C0231-50CM  
*All cable assemblies have a length tolerance of 1.5% or ± 3/8”, whichever is greater.  
Environmental Specifications  
Temperature  
Operating Range  
-55 to +200 deg C  
Compliance Certifications (see product page for current document)  
Plotted and Other Data  
Notes:  
Values at 25°C, sea level.  
How to Order  
Part Number Configuration:  
PE3C0231  
-
xx  
uu  
|
|
|
Unit of Measure:  
cm = Centimeters  
<blank> = Inches  
Length  
|
|
|
|
|
|
Base Number  
Example:  
PE3C0231-12 = 12 inches long cable  
PE3C0231-100cm = 100 cm long cable  
N Male to N Male Low Loss Cable 50 cm Length Using PE-P142LL Coax with HeatShrink from Pasternack Enterprises has  
same day shipment for domestic and International orders. Our RF, microwave and millimeter wave products maintain a 99%  
availability and are part of the broadest selection in the industry.  
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,  
inventory and certifications: N Male to N Male Low Loss Cable 50 cm Length Using PE-P142LL Coax with HeatShrink  
PE3C0231-50CM  
URL: https://www.pasternack.com/n-male-n-male-pe-p142ll-cable-assembly-pe3c0231-50cm-p.aspx  
PE3C0231-50CM REV 1.3  
3
PE3C0231-50CM CAD Drawing  
N Male to N Male Low Loss Cable 50 cm Length Using PE-P142LL Coax with HeatShrink  
PE3C0231-50CM REV 1.3  
4

相关型号:

PE3C0230-12

SMA Male to SMA Male Low Loss Cable 12 Inch Length Using PE-P142LL Coax with HeatShrink
PASTERNACK

PE3C0230-120

SMA Male to SMA Male Low Loss Cable 120 Inch Length Using PE-P142LL Coax with HeatShrink
PASTERNACK

PE3C0230-200CM

SMA Male to SMA Male Low Loss Cable 200 cm Length Using PE-P142LL Coax with HeatShrink
PASTERNACK

PE3C0230-72

SMA Male to SMA Male Low Loss Armored Test
PASTERNACK

PE3C0231

N Male to N Male Low Loss Armored Test Cable Using PE-P142LL Coax
PASTERNACK

PE3C0231-100CM

N Male to N Male Low Loss Cable 100 cm Length Using PE-P142LL Coax with HeatShrink
PASTERNACK

PE3C0231-120

N Male to N Male Low Loss Cable 120 Inch Length Using PE-P142LL Coax with HeatShrink
PASTERNACK

PE3C0231-150CM

N Male to N Male Low Loss Cable 150 cm Length Using PE-P142LL Coax with HeatShrink
PASTERNACK

PE3C0231-200CM

N Male to N Male Low Loss Cable 200 cm Length Using PE-P142LL Coax with HeatShrink
PASTERNACK

PE3C0231-36

N Male to N Male Low Loss Cable 36 Inch Length Using PE-P142LL Coax with HeatShrink
PASTERNACK

PE3C0231-50CM

N Male to N Male Low Loss Cable 50 cm Length Using PE-P142LL Coax with HeatShrink
PASTERNACK

PE3C0231-60

N Male to N Male Low Loss Cable 60 Inch Length Using PE-P142LL Coax with HeatShrink
PASTERNACK