PT8A261 [PERICOM]

PIR Sensor Light Switch Controller; PIR感应灯开关控制器
PT8A261
型号: PT8A261
厂家: PERICOM SEMICONDUCTOR CORPORATION    PERICOM SEMICONDUCTOR CORPORATION
描述:

PIR Sensor Light Switch Controller
PIR感应灯开关控制器

开关 控制器
文件: 总13页 (文件大小:106K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Pad Location  
Pad Location of PT8A261DE  
1470um  
Die No.  
OSCD  
TRIAC  
GND  
CDS  
ZC OSCS  
MODE  
VCC  
OP2O  
VCC  
NC  
OP2N  
OP2P  
VEE  
RST  
OPIP OPIN OPIO  
Pad Coordinate  
Pad Name  
X Coordinate  
Y Coordinate  
Pad Name  
X Coordinate  
Y Coordinate  
GND  
TRIAC  
OSCD  
OSCS  
ZC  
570  
570  
65.4  
NC  
VEE  
570  
-570  
303.9  
-44.8  
-211.8  
-570  
-570  
-570  
-570  
-268.6  
232.4  
-687.2  
689.2  
689.2  
-435.6  
-268.6  
-101.6  
65.4  
-101.6  
399.4  
232.4  
689.2  
-687.2  
-435.6  
-687.2  
-687.2  
570  
570  
RST  
OP1P  
OP1N  
OP1O  
OP2P  
OP2N  
OP2O  
-378.8  
-30.1  
570  
-197.1  
136.9  
CDS  
MODE  
VCC  
VCC  
Note: Substrate is connected to GND  
PT0075(04/03)  
Ver:5  
2
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Pad Location of PT8A262DE  
1470um  
Die No.  
OSCD  
RELAY  
GND  
CDS  
ZC OSCS  
MODE  
VCC  
OP2O  
VCC  
NC  
OP2N  
OP2P  
VEE  
RST  
OPIP OPIN OPIO  
Pad Coordinate  
Pad Name  
X Coordinate  
Y Coordinate  
Pad Name  
X Coordinate  
Y Coordinate  
GND  
RELAY  
OSCD  
OSCS  
ZC  
CDS  
MODE  
VCC  
570  
570  
570  
65.4  
NC  
570  
-570  
303.9  
-44.8  
-211.8  
-570  
-570  
-570  
-570  
-268.6  
232.4  
-687.2  
689.2  
689.2  
-435.6  
-268.6  
-101.6  
65.4  
-101.6  
399.4  
232.4  
689.2  
-687.2  
-435.6  
-687.2  
-687.2  
VEE  
RST  
570  
OP1P  
OP1N  
OP1O  
OP2P  
OP2N  
OP2O  
-378.8  
-30.1  
570  
-197.1  
136.9  
VCC  
Note: Substrate is connected to GND  
PT0075(04/03)  
Ver:5  
3
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Pin Assignment  
Figure 2  
PT8A261P/PT8A261W  
PT8A262P/PT8A262W  
GND  
TRIAC  
OSCD  
OSCS  
ZC  
1
2
3
4
5
6
7
8
16  
15  
14  
13  
12  
11  
10  
9
OP2O  
OP2N  
OP2P  
OP1O  
OP1N  
OP1P  
RST  
GND  
RELAY  
OSCD  
OSCS  
ZC  
1
2
3
4
5
6
7
8
16  
15  
14  
13  
12  
11  
10  
9
OP2O  
OP2N  
OP2P  
OP1O  
OP1N  
OP1P  
RST  
CDS  
CDS  
MODE  
VCC  
MODE  
VCC  
VEE  
VEE  
Top view  
Top view  
Pin Description  
Table 1  
Pin/Pad  
261 262  
Name  
Type  
Ground Ground  
Description  
1
1
2
GND  
RELAY  
TRIAC  
OSCD  
O
O
RELAY drive output through an external NPN transistor, active high  
TRIAC drive two-pulse output, active negative pulse.  
2
3
3
4
5
6
I/O  
Output timing oscillator I/O, connected to an external RC to adjust output duration.  
System oscillator I/O, connected to an external RC to set the system frequency. The system  
frequency = 16kHz for normal application.  
4
5
6
OSCS  
ZC  
I/O  
I
I
Schmitt input for AC zero crossing detection.  
Connected to a CDS voltage divider for daytime/night auto-detection. Low input to this pin  
can disable PIR input. CDS is a schmitt trigger input with 5-second input debounce time.  
CDS  
Mode select, connecting to VCC- output always on, connection GND - output always off,  
open - auto detection  
7
8
9
7
8
9
MODE  
VCC  
I
Power Power supply  
Internal voltage regulator output, 3.6V with respect to ground. Connected to the drain of  
PIR sensor  
VEE  
O
10  
11  
12  
13  
14  
15  
16  
10  
11  
12  
13  
14  
15  
16  
RST  
I
I
Chip reset input, active low, kept floating or connected an RC network  
Non-inverted input of first operational amplifier, connected directly to source of PIR sensor  
Inverted input of first operational amplifier  
OP1P  
OP1N  
OP1O  
OP2P  
OP2N  
OP2O  
I
O
I
Output of first operational amplifier  
Non-inverted input of second operational amplifier.  
Inverted input of second operational amplifier  
Output of second operational amplifier  
I
O
PT0075(04/03)  
Ver:5  
4
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
OSCS and OSCD Pins  
Functional Descriptions  
OSCS is a system oscillator I/O pin connected to an external  
RC to generate system frequency of 16kHz.  
The PT8A261 and PT8A262 are CMOS LSI chips designed for  
automatic PIR lamp control. They can operate in 2-wire con-  
figuration for triac applications or in 3-wire configuration for  
relay applications.  
OSCD is an output timing oscillator I/O pin. It’s connected to  
an external RC to obtain the desired turn-on duration by se-  
lecting various values of RC or using a variable resistor.FOSCD  
is the frequency of OSCD pin, output timing can be caculated  
as the formula: TD = 21504/FOSCD  
The device consists of operational amplifiers, a comparator,  
timer, a zero crossing detector, control circuit, a voltage regu-  
lator, a system oscillator, and an output timing oscillator.  
CDS Input Circuit  
The PIR sensor detects infrared power variations caused by  
motion of a human body and transfer to a voltage variation. If  
the PIR output voltage variation conforms to criteria, the lamp CDS is a CMOS schmitt trigger input pin. It is used to distin-  
is turned on for an adjustable duration. The PT8A261 (or 262) guish between day time and night time. When the input volt-  
offers three operating modes (ON, AUTO, OFF) which can be age of CDS is high the PIR input is enabled, when CDS low the  
set through a MODE pin. When the device is working in AUTO PIR input disabled. The input disable-to-enable debounce  
mode, the user can override the mode to switch it to TEST time is 5 seconds. Connect this pin to VCC when not using it.  
mode or manual ON mode, or return to the AUTO mode by The CDS input is ignored when the TRIAC or RELAY output  
switching power switch.  
is active.  
Figure 3. System Oscillator  
Figure 4. Output Timing Oscillator  
TD = 21504/FOSCD  
RD  
RS  
560K  
OSCS  
OSCD  
PT8A261/  
262  
PT8A261/  
262  
CD  
C
S
200P  
Figure 5. CDS Input Circuit  
Table 2. CDS Pin Function  
VCC  
CDS  
LOW  
HIGH  
Status  
Day Time  
PIR  
Schmitt  
Driver  
Rp  
Disabled  
Enabled  
CDS  
CDS  
Control  
CDS Circuit  
Night  
PT8A261/262  
Figure 6. CDS Enable Debounce  
CDS  
< 5s  
> 5s  
PIR Enable  
Disable  
Enable  
PT0075(04/03)  
Ver:5  
5
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
vice can be toggled from ON to AUTO by switching the power  
switch twice within 3 seconds again (override operation).  
MODE  
MODE is a tri-state input pin for operation mode selection.  
See the following table 3.  
If the chip is overridden to ON and there is no further override  
operation, it will return to AUTO automatically after an inter-  
nal preset ON time duration (8 hours).  
Override Control: The term “override” refers to the change of  
operating mode by switching the power switch twice within 3  
seconds. When the chip is working in the AUTO mode (MODE  
pin openned), the output is activated by a valid PIR trigger  
signal and the output active duration is controlled by the OSCD  
oscillation period. The lamp can be switched to ON from the  
AUTO mode by either switching the MODE pin to VCC or  
switching the power switch twice within 3 seconds. The de-  
The override operation will cause the lamp flash (for TRIAC  
version only). It will flash 3 times at 1Hz rate when changing  
AUTO mode to other mode, and flash 3 times at 2Hz rate when  
returning to AUTO mode. But no flash if mode is changed by  
switching the MODE switch. See Figure 7 for override timing.  
Table 3. Operation Modes by MODE Pin  
MODE  
Status  
Operation  
Mode  
Description  
Output is always ON: RELAY pin sends high level for relay driving; TRIAC pulse train output is  
synchronized by ZC for triac driving.  
VCC  
ON  
OFF  
Output is always OFF: RELAY pin sends low level for relay driving; TRIAC pin sends high level  
for triac driving.  
GND  
Open  
Outputs remain in the OFF state until activated by a valid PIR trigger input signal. When working  
in the AUTO mode, the device allows override control by switching the ZC signal.  
AUTO  
Figure 7. Override Timing  
flash  
ON  
flash  
flash  
flash  
Operating Mode  
AUTO  
AUTO  
ON  
8 hours  
AUTO  
ZC  
Flash is only for TRIAC version  
Figure 8. RST Application Example  
RST Pin  
RST is used to reset the device. It is internal pull-high and  
active low. The use of CRST can extend the power-on initial  
time. If the RST pin is openned (without CRST), the initial  
time is 40 seconds. See Figure 8.  
VCC  
REST  
RST  
CRST  
GND  
PT0075(04/03)  
Ver:5  
6
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
In case that the ZC signal disappears more than 3 seconds, the  
chip will restart the initialization operation. However, the re-  
start initial time is always 40 seconds and cannot be extended  
by adding CRST to the RST pin as shown in Figure 6.  
Power On Initial  
The PIR signal amplifier requires a warm up period after power-  
on. The input should be disabled during this period.  
Trigger  
In the AUTO mode within the first 10 seconds of the initial  
time the chip allows override control to enter the quickly in-  
stall mode.After 40s of the initial time the chip allows over-  
ride control between ON and AUTO. It will remain in the warm  
up period if the total initial time has not elapsed after return-  
ing to AUTO.  
The trigger timing is shown in Figure 9.  
Retrigger -- If another signal is attained in trigger hold time,  
the circuit will be retriggered, and the trigger hold time will be  
restarted from this time.  
Figure 9. Trigger Timing  
RST  
CDS  
5s  
Output  
Enable  
+trigger level  
-trigger level  
Comparator  
Input  
>24ms  
Comparator  
Output  
<24ms  
(Note1)  
Detect  
Enable  
power on delay time  
40s  
10s test  
enable  
Test  
Enable  
RELAY  
ON  
ON  
TRIAC  
pulse out  
(Note2)  
Notes: 1. The output is activated if the trigger signal conforms to the following criteria:  
- More than 3 triggers within 2 seconds,  
- A trigger signal sustain duration > 0.34 seconds, and  
- 2 triggers within 2 seconds with pulse duration of one > 0.16 seconds.  
- The effective comparator output width is 24ms.(Fosc=16KHz)  
2. The output duration is set by an external RC connected to the OSCD pin.  
PT0075(04/03)  
Ver:5  
7
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Maximum Ratings  
(Above which the useful life may be impaired. For user guidelines, not tested)  
Note:  
Stresses greater than those listed under MAXIMUM  
Storage Temperature ............................................................-40oC to +125oC  
RATINGS may cause permanent damage to the  
Supply Voltage to Ground Potential (Inputs & VCC Only) .... -0.3 to +6.0V  
device. This is a stress rating only and functional  
Supply Voltage to Ground Potential (Outputs & D/O Only) -0.3 to +6.0V  
operation of the device at these or any other condi-  
DC Input Voltage ....................................................................... -0.3 to +6.0V  
tions above those indicated in the operational sec-  
DC Output Current .................................................................................20mA  
tions of this specification is not implied. Exposure  
Power Dissipation .............................................................................. 500mW  
to absolute maximum rating conditions for ex-  
tended periods may affect reliability.  
Recommended Operation Conditions  
Sym  
VCC  
VIH  
Description  
Min  
4.75  
0.8VCC  
-
Typ  
5.0  
-
Max  
6.0  
Units  
V
Supply Voltage  
Input HIGH Voltage (MODE,RST)  
Input LOW Voltage (MODE,RST)  
System Oscillator Frequency  
Delay Oscillator Frequency  
Operation Temperature  
-
V
VIL  
-
0.2VCC  
19.2  
19.2  
70  
V
fSYS  
fDOSC  
TA  
12.8  
12.8  
-25  
16  
16  
25  
kHz  
kHz  
OC  
DC Electrical Characteristics  
Sym  
Description  
Test Conditions  
VIH = 4.5V  
Min  
Typ  
Max  
0.1  
Units  
IIH  
Input high level leakage current(ZC,CDS)  
Input low level leakage current(ZC,CDS)  
-0.1  
-0.1  
-
-
mA  
IIL  
VIL = 0.5V  
0.1  
mA  
mA  
mA  
V
IOH  
Output Source Current (RELAY, TRIAC)  
Output Sink Current (RELAY, TRIAC)  
CDS Transfer High Voltage  
CDS Transfer Low Voltage  
VOH = 4.5V  
VOL = 0.5V  
-6  
-
-
IOL  
15  
-
-
VTH1  
VTL1  
VTH2  
VTL2  
VTH3  
VTL3  
VTH4  
VTL4  
3.0  
1.5  
2.6  
1.0  
2.2  
1.0  
2.2  
0.4  
3.2  
1.7  
2.9  
1.4  
2.4  
1.4  
2.4  
0.6  
3.6  
2.1  
3.2  
1.6  
2.8  
1.6  
2.8  
0.8  
V
ZC Transfer High Voltage  
V
ZC Transfer Low Voltage  
V
OSCS Transfer High Voltage  
OSCS Transfer Low Voltage  
OSCD Transfer High Voltage  
OSCD Transfer Low Voltage  
V
V
V
V
Note: These specifications apply for VCC = 5.0V and -25OC £ TA £ 70OC, unless otherwise specified.  
PT0075(04/03)  
Ver:5  
8
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
AC Electrical Characteristics  
Voltage Regulator  
Sym  
Description  
Test Conditions  
Min  
Typ  
Max  
Units  
V
VEE  
Output Voltage  
No load  
3.2  
3.6  
4.0  
V
VOP2P  
Noninverting input of OP2  
No load  
1.6  
1.8  
2.0  
DVO  
DVLDR  
IL  
Line Regulation  
Load Regulation  
4.5V £ VCC £ 5.5V, IL = 1mA  
VCC = 5V, 0.5mA £ IL£ 2mA  
VCC = 5V  
-
-
30  
60  
-
50  
100  
-
mV  
mV  
mA  
Regulator Output Current  
4
Operational Amplifier and Window Comparator  
Sym  
BW  
VTH  
VTL  
Description  
Test Conditions  
Min  
10  
Typ  
-
Max  
-
Units  
kHz  
V
3dB Bandwidth  
-
VCC = 5V  
1.9  
1.4  
2.05  
1.55  
2.2  
1.7  
Windows Comparator Threshold  
VCC = 5V  
V
PT0075(04/03)  
Ver:5  
9
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Oscillator and ZC Input Pulse and Trigger Output Pulse  
Sym  
Description  
Test Conditions  
Min  
Typ  
Max  
Units  
fOSC  
tZR  
Oscillator Frequency  
ZC Pulse Rise Time  
ZC Pulse Fall Time  
ZC Pulse Period  
12.8  
-
16  
30  
30  
20  
1
19.2  
100  
100  
22.2  
-
kHz  
ns  
tZF  
-
ns  
tZP  
15.1  
0.8  
ms  
ms  
VCC= 5V, RS = 560W,  
CS = 200pF, see above fig 3  
tZW  
ZC Pulse Width  
tOR  
tOF  
tOP  
tOW  
TRIAC Pulse Rise Time  
TRIAC Pulse Fall Time  
TRIAC Pulse Period  
TRIAC Pulse Width  
-
-
30  
30  
100  
100  
11  
ns  
ns  
6.6  
52  
10  
ms  
ms  
62.5  
76  
Figure 10. Timing Diagram  
tZR  
tZF  
ZC  
tZW  
tZP  
tOF  
tOR  
TRIAC  
tOW  
tOP  
Power Dissipation  
Sym  
Description  
Test Conditions  
Min  
Typ  
80  
Max  
100  
80  
Units  
mA  
VCC = 5V, RS = 560kW ,CS=200P,  
RD = 560kW , CD = 200P,  
other input pins = GND, all  
outputs float. see fig 3,4  
ICC  
Power Supply Current  
-
-
VCC = 5V, All Input Pins = GND,  
all outputs float.  
ICCQ  
Quiescent Power Supply Current  
60  
mA  
PT0075(04/03)  
Ver:5  
10  
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Typical Application Circuits  
Figure 11. Two-Wire Application Circuit of PT8A261  
PT0075(04/03)  
Ver:5  
11  
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Figure 12. Three-Wire Application Circuit of PT8A262  
ON  
AUTO  
OFF  
PT0075(04/03)  
Ver:5  
12  
Data Sheet  
PT8A261/262  
PIR Sensor Light Switch Controller  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Notes  
Pericom Technology Inc.  
Email: support@pti.com.cn  
Web Site: www.pti.com.cn, www.pti-ic.com  
China:  
No. 20 Building, 3/F, 481 Guiping Road, Shanghai, 200233, China  
Tel: (86)-21-6485 0576 Fax: (86)-21-6485 2181  
Asia Pacific: Unit 1517, 15/F, Chevalier Commercial Centre, 8 Wang Hoi Rd, Kowloon Bay, Hongkong  
Tel: (852)-2243 3660 Fax: (852)- 2243 3667  
U.S.A.:  
2380 Bering Drive, San Jose, California 95131, USA  
Tel: (1)-408-435 0800 Fax: (1)-408-435 1100  
Pericom Technology Incorporation reserves the right to make changes to its products or specifications at any time, without notice, in order to  
improve design or performance and to supply the best possible product. Pericom Technology does not assume any responsibility for use of any  
circuitry described other than the circuitry embodied in Pericom Technology product. The company makes no representations that circuitry  
described herein is free from patent infringement or other rights, of Pericom Technology Incorporation.  
PT0075(04/03)  
Ver:5  
13  

相关型号:

PT8A2611

PIR Sensor Light Switch Controller
PERICOM

PT8A2611D

PIR Sensor Light Switch Controller
ETC

PT8A2611DE

PIR Sensor Light Switch Controller
PERICOM

PT8A2611P

PIR Sensor Light Switch Controller
PERICOM

PT8A2611W

PIR Sensor Light Switch Controller
PERICOM

PT8A2611W

Analog Circuit, 1 Func, CMOS, PDSO16, SOP-16
DIODES

PT8A2611WEX

Analog Circuit, CMOS, PDSO16,
DIODES

PT8A2612

PIR Sensor Light Switch Controller
PERICOM

PT8A2612DE

PIR Sensor Light Switch Controller
PERICOM

PT8A2612P

PIR Sensor Light Switch Controller
PERICOM

PT8A2612W

PIR Sensor Light Switch Controller
PERICOM

PT8A261DE

PIR Sensor Light Switch Controller
PERICOM