POE576U-4MP-N-R [PHIHONG]

Phihong Midspan POE with TCPIP (SNMPv2c); 飞宏中跨POE用TCPIP ( SNMP v2c版本)
POE576U-4MP-N-R
型号: POE576U-4MP-N-R
厂家: PHIHONG USA INC.    PHIHONG USA INC.
描述:

Phihong Midspan POE with TCPIP (SNMPv2c)
飞宏中跨POE用TCPIP ( SNMP v2c版本)

文件: 总45页 (文件大小:1911K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Phihong Midspan POE with TCPIP (SNMPv2c)  
User Manual  
TCPIP (SNMPv2c) Rev 1.6  
PES12779  
Compliant Models:  
POE75U-1UP-N-R  
POE240U-1MP-N-R  
POE240U-2MP-N-R  
POE125U-4AT-N-R  
POE240U-4UP-N-R  
POE576U-4MP-N-R  
POE576U-8UP-N-R  
POE806U-8MP-N-R  
Disclaimer  
Phihong accepts no accountability or liability arising from the use of the Midspans, as described in  
this document. The handling of equipment will be users’ responsibility. Applications described in this  
document are for descriptive purposes only. Phihong does not provide warranty on modified products.  
Notice  
This document contains informative information about the software and hardware used on the Mid-  
span. The information is held to be accurate and reliable from time of print. Please be advised that  
product development and revisions are still in course of action. Phihong cannot be held responsible for  
involuntary error, exclusions, inaccuracies, or following changes of printed material.  
Phihong reserves the right to make changes to products and to their specifications as described in this  
document, at any time, without prior notice. The contents of this document may not be photocopied  
or reproduced in any form without written permission of Phihong.  
NOTE: Midspans are for indoor use only!  
© August 2009 Phihong USA Corp.  
All Rights Reserved.  
This document is subject to change without notice.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-2-  
Contents  
Overview ............................................................................................................................................... 5  
1. Safety Procedures ............................................................................................................................ 6  
1.1. General Precautions ................................................................................................................. 6  
2. Midspan Hardware Setup ................................................................................................................. 8  
2.1. Physical Hardware Appearance ................................................................................................ 8  
2.2. Connecting Ethernet Cables ................................................................................................... 11  
2.3. Midspan Accessories .............................................................................................................. 14  
2.4. Powering Up Midspan ............................................................................................................ 15  
2.5. LED Indicators ........................................................................................................................ 16  
2.6. Technical Specifications ......................................................................................................... 17  
3. Midspan Monitoring and Control --- HTTP Protocol ...................................................................... 18  
3.1. Port Control Webpage ............................................................................................................ 18  
3.2. Administrative Management Webpage ................................................................................... 21  
3.3. Network Settings Webpage .................................................................................................... 21  
3.4. SNMP Community String Webpage ...................................................................................... 23  
3.5. System Tools Webpage .......................................................................................................... 24  
4. Midspan Monitoring and Control with MIB Browser --- SNMP Protocol ....................................... 26  
4.1. Structure of Management Information (SMI) of Phihong Midspan ......................................... 26  
4.2. Phihong Midspan MIB ............................................................................................................ 28  
4.3. Notes for Using Phihong Midspan MIB .................................................................................. 32  
4.4. Using MG-SOFT MIB Browser to run Phihong Midspan ........................................................ 33  
5. Field Firmware Updating ................................................................................................................ 39  
5.1. Updating Microprocessor Flash Contents with POEA-x.x.bin ................................................ 39  
5.2. Updating EEPROM Contents with POEB-x.x.bin ................................................................... 42  
6. Troubleshooting .............................................................................................................................. 44  
7. Frequently Asked Questions ......................................................................................................... 45  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-3-  
List of Figures  
Figure 1 – Single Port Midspan Ports ................................................................................................... 8  
Figure 2 – Single Port Midspan AC Input ............................................................................................. 8  
Figure 3 – Small Frame Multiport Midspan Ports ................................................................................ 9  
Figure 4 – Small Frame Multiport Midspan AC Input ........................................................................... 9  
Figure 5 – 1U Multiport Midspan Ports .............................................................................................. 10  
Figure 6 – 1U Multiport Midspan AC Input ......................................................................................... 10  
Figure 7 – Single Port Midspan SNMP Connection ........................................................................... 11  
Figure 8 – Single Port Midspan Data and PoE Connections .............................................................. 11  
Figure 9 – Small Frame Multiport Midspan SNMP Connection ......................................................... 12  
Figure 10 – Small Frame Multiport Midspan PoE Connections ......................................................... 12  
Figure 11 – 1U Multiport Midspan SNMP Connection ....................................................................... 13  
Figure 12 – 1U Multiport Midspan POE Connections ........................................................................ 13  
Figure 13 – Single Unit Rack Mount ................................................................................................... 14  
Figure 14 – Two Units in Side by Side Rack Mounting ...................................................................... 14  
Figure 15 – 19” Midspan Rack Mount ................................................................................................ 14  
Figure 16 – Rack Mounting Brackets and Screws ............................................................................ 14  
Figure 17 – AC Cord ........................................................................................................................... 14  
Figure 18 – Management Set-up Diagram ......................................................................................... 18  
Figure 19 – Port Control Webpage ..................................................................................................... 18  
Figure 20 – Administrative Management Webpage ............................................................................ 21  
Figure 21 – Network Settings Webpage ............................................................................................. 22  
Figure 22 – Reboot Webpage ............................................................................................................. 23  
Figure 23 – SNMP Community Strings Webpage .............................................................................. 23  
Figure 24 – System Tools Webpage ................................................................................................... 25  
Figure 25 – Phihong Midspan SMI ..................................................................................................... 26  
Figure 26 – Phihong Midspan SMI Continued ................................................................................... 27  
Figure 27 – Generate Phihong SNMPv2c MIB Module ...................................................................... 33  
Figure 28 – Set SNMP Protocol to contact remote SNMP Agent ...................................................... 35  
Figure 29 – Phihong Midspan MIB Tree ............................................................................................. 36  
Figure 30 – Set IP Address of Trap Receiver ...................................................................................... 37  
Figure 31 – Trap Ringer Console ........................................................................................................ 38  
Figure 32 – TFTP Uploading Using Application Entry Mode .............................................................. 40  
Figure 33 – Set Static IP in Internet Protocol (TCP/IP) Properties Window ....................................... 41  
Figure 34 – Upload in Internet Explorer .............................................................................................. 42  
Figure 35 – Software Update Successful Window ............................................................................. 42  
Figure 36 – Upload Using System Tools on Web Interface ................................................................ 43  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-4-  
Overview  
Phihong’s midspans are Power over Ethernet (PoE) injectors with output options ranging from  
15.4W to 95W per port. Available with 1, 2, 4, 8, 16 or 24 ports, Phihong’s midspans put out full  
power every port with no need to manage power across ports.  
By using the SNMPv2C (Simple Networking Management Protocol version 2C) protocol, users can  
monitor and control the port status over their internet browser. Linking an Ethernet cable between  
their midspan and management computer, locally or otherwise through a network switch, users  
may manage certain functions including remote reset of powered devices. Users may connect to  
their midspan using the DHCP client on the midspan which will create a dynamic hostname and IP  
address unique to the network. Otherwise a Static IP address may be created by the user.  
Internet browsers that users may choose from to access their Phihong midspans including:  
Internet Explorers 7 and 8 found on Windows XP, Windows Vista and Windows 7. Mozilla Firefox,  
Google Chrome, Opera and Safari may also be used. To update the firmware on your midspan,  
only Microsoft XP or Vista may be used at this time. Please check www.phihong.com or www.  
midspans.com for support updates or contact us at poe@phihongusa.com for additional questions  
regarding compatibility. For SNMO interface, users may refer to the SNMP console manual for PC  
requirements.  
A default username and password come preset on your Phihong midspan. Entering “admin” in  
both fields will allow users to gain access to customize their security settings. The default read-  
only community string is “Phihong_read_only” and users may enter “Phihong” for the read-write  
community field. Select tools that users may access through Phihong’s management interface is  
port control (i.e. turn on/off), change access strings (hostname, username, password etc.), and set  
IP Address to dynamic DHCP to allow it to be set automatically or Static as customized by the user.  
Additionally, users may configure and send SNMPv2C TRAPs which are triggered on changes to  
port status.  
Phihong may release new firmware and updates at any time, so it is advised to check our websites  
regularly for any updates that may affect your midspan. For the models listed on the cover page, two  
firmware files are used. The first is POEA-x.x.x.bin which is uploaded to an internal microprocessor  
under Windows TFTP command. The second is POEB-x.x.x.bin which is uploaded directly into an  
internal EEPROM by entering http://hostmane/upload into your internet browser or by using web  
<system tools>.  
More detailed instruction may be found in this manual.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-5-  
1.  
Safety Procedures  
1.1. General Precautions  
General – Please read the following precautions carefully before installing and connecting the system  
to a power source.  
Note – Only qualified and trained service personnel (in accordance with IEC 60950 and AS/NZS  
3260) should install, replace, or service the equipment. Install the system in accordance with Coun-  
try, National or to the U.S. National Electric Code if you are in the United States.  
Precautions:  
1. The building facilities in which the product will be used requires a fuse or circuit breaker no larger  
than 15A for 120Vac (U.S.A.) or 10A, 230Vac (international). The building facilities must protect the  
Midspan from over current and short-circuits.  
2. Before connecting the Midspan to a power source (including power cord requirements), read  
the Midspan Hardware Setup procedure in Section 2. This procedure as with all procedures and  
instructions can be found in the Midspan User Manual. To download a copy of the Manual, visit  
www.phihong.com or www.midspans.com.  
3. To prevent the Midspan from overheating, do not operate the product in an area that exceeds the  
maximum recommended ambient temperature of 40oC. Allow at least 3 to 4 inches of clearance  
around all ventilation openings.  
4. In order to support the midspan’s weight, do not stack the chassis on any other equipment. Shelf  
mounted equipment requires a stable and durable surface. When installed, do not push or pull on  
the Midspan when the equipment is installed.  
5. The Midspan consists of two rows of “Data” and “Data & Power” ports. The ports use RJ-45  
data sockets. Do not connect telephone cables into these ports. Only RJ-45 data cables may be  
connect to these sockets.  
6. Do not work on the Midspan system or connect or disconnect the cables, during periods of lightning  
activity.  
7. The AC plug/socket combination must be accessible at all times, as it serves as the main disconnect  
device to the product.  
8. Before servicing the product, always disconnect the products from its AC and DC source.  
9. Disposal of this product should abide by all appropriate National laws and regulations.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-6-  
1.1  
Sicherheitsmaßnahmen – Allgemeine Vorsichtsmaßnahmen  
Allgemein – Lesen Sie die folgenden Vorsichtsmaßnahmen sorgäfltig durch, bevor Sie das System  
installieren und an eine Energiequelle anschließen.  
Hinweis – Das Gerät derf nur durch qualifiziertes und geschultes tehisches Personal (gemäß IEC  
60950 [Vorschrift 60950 der Internationalen Elektrischen Kimmission] und AS/NZS 3260 [Vorschrift für  
Australien und Neuseeland]) installiert, ersetzt oder repariert werden. Installieren Sie das System auch  
in Übereinstimmung mit den geltenden nationalen oder europäischen Vorschriften bzw. Der NEC-  
Vorschrift, falls Sie sich in den Vereinigten Staaten befinden.  
Vorsichtsmaßnahmen:  
1. Die Gebäudeinstallationen, in denen das Produkt benutzt wird, müssen über eine Sicherung oder  
einen Schutzschalter mit maximal 15A für 120 Vac (USA) oder 10A für 230Vac (ineternational)  
verfügen. Dis Gebäudeinstallationen müssen das Midspan-Device vor zu starkem Strom oder  
Kurzchlüssen schützen.  
2. Lesen Sie vor dem Anschließen des Midspan-Device an eine Energiequelle (einschließlich der  
erforderlichen Anschlussleitungen) die Setup-Anleitung für Ihre Midspan-Hardware in Kapitel 2  
genau druch. Dieses Verfahren wird zusammen mit allen weiteren Vorgängen und Anwisungen  
im Benutzerhandbuch für das Midspan-Device beschrieben. Sie Können das Benutzerhandbuch  
unter www.midspans.com oder www.phihong.com herunterladen.  
3. Um das Midspan-Device vor Überhitzung zu schübenutzen Sie das Produkt nicht in Räumen, die  
die maximale empfohlene Umgebungstemperatur von 40oC überschreiten. Lassen Sie um alle  
Lüftungsöffnungen herum mindestens 7,5 bis 10 cm (3-4 inches) frei.  
4. Stützen Sie das Gewicht des PoE Midspan-Device nicht ab, indem Sie das Gehäuse auf ein  
anderes Gerät stellen. Falls Sie das Gerät auf ein Gestell montieren, muss dieses eine stabile und  
haltbare Oberfläche haben. Nach der Installation des Systems bewegen Sie das Midspan-Device  
nicht mehr.  
5. Ds Midspan-Device enthält zwei Reihen mit “Datenports” und “Daten-und-Stromports.” Die  
Ports verwenden RJ45-Datenanschlüsse. Schließen Sie keine Kabel an und trennen Sie keine  
Kabelverbindungen während Gewittern mit Blitzen.  
6. Führen Sie an dem Midspan-System keine Arbeiten durch schließen Sie keine Kabel an und trennen  
Sie keine Kabelverbindungen während Gewittern mit Blitzen.  
7. Der Steckanschluss Wechselstrom muss jederzeit zugänglich sein, da er als Haupttrenngerät für  
das Produkt dient.  
8. TrennenSiedasProduktimmererstvonderStromquelle,bevorSieWartungs-oderreparaturarbeiten  
daran durchführen.  
9. Entsorgen Sie dieses Produkt gemäß aller geltenden Gesetze und Vorschriften Ihres Landes und  
der EU (falls Sie sich in einem Land der EU befinden).  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-7-  
2. Midspan Hardware Setup  
2.1 Physical Hardware Appearance:  
2.1.1 Single Port Models  
Front View:  
NIC  
Connector  
Port  
Data In  
PoE Out  
Figure 1: Single Port Midspans Ports  
Rear View:  
IEC320 C14  
AC Input  
Figure 1: Single Port Midspan AC Input  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-8-  
2.1.2 Small Frame Multiport Models  
Front View:  
Figure 3: Small Frame Multiport Midspan Ports  
Row 1: Data and Power OUT  
NIC Management Port  
to the Powered Device  
Row 2: Data IN from the Network  
Switch  
Rear View:  
Figure 4: Small Frame Multiport Midspan AC Input  
IEC320 C14 AC Input  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-9-  
2.1.3 1U Multiport Midspans  
Front View:  
Figure 5: 1U Multiport Midspan Ports  
NIC Management Port  
Row 1: Data and Power OUT  
to the Powered Device  
Row 2: Data IN from the Network  
Switch  
Rear View:  
Figure 6: 1U Multiport Midspan AC Input  
IEC320 C14 AC Input  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-10-  
2.2  
Connecting Ethernet Cables*  
2.2.1 Single Port Midspans  
NIC Connection:  
NIC Port Connected  
to management  
computer  
Figure 7: Single Port Midspan SNMP Connection  
Ports Connection:  
Figure 8: Single Port Midspan PoE and Data Connection  
Diagnostic LEDS  
Data IN  
from Network Switch  
PoE OUT  
*Ethernet cables are not included  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-11-  
2.2.2 Small Frame Multiport Midspans  
NIC Connection:  
NIC Port Connected  
to managment  
computer  
Figure 9: Small Frame Multiport Midpsan SNMP Connection  
Ports Connection:  
PoE OUT  
Connected to a  
Valid Load  
Figure 10: Small Frame Multiport Midpsan Data and PoE Connection  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-12-  
2.2.3 1U Multiport Midspans  
NIC Connection:  
NIC Port Connected  
to managment  
computer  
Figure 11: 1U Multiport Midpsan SNMP Connection  
Ports Connection:  
Figure 12: 1U Multiport Midpsan Data and PoE Connection  
PoE OUT  
Connected to a  
Valid Load  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-13-  
2.3  
Midspan Accessories  
2.3.1 Rack Mounting Options/AC Power Cord  
All multiport midspans may be rack mounted on a 19”1U rack in either single or double unit mounts  
(Small footprint multiport midspans). To position the Midspan on the rack; arrange the mounting bracket  
to the corresponding screw holes on the Midspan. Keep the screw area visible to insert screws, and  
then tighten the screws. Screws and brackets will be included in the package. For replacement parts  
contact Phihong for part number POE125U-ACCY01-R.  
Figure 13: Single Unit Rack Mount  
Figure 14: Two Units in Side by Side Rack Mounting  
Figure 15: Rack Mounted 19” Midspan  
Figure 16: Mounting Bracket  
Figure 17: AC Power Cord*  
The AC power cable is connected to the  
AC power connector located in the rear  
side of the Midspan and the power outlet.  
*AC Power Cord may be ordered seperately.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-14-  
2.4 Powering Your Midspan  
Power Cord Requirements  
Power cords must meet the requirements for the country it is intended to be used.  
U.S.A and  
Canada  
• The cord must have a minimum of 10A rated current competence  
• The cord must be CSA or UL approved  
• The minimum requirement for the flexible cord is:  
o 18 AWG (10A)  
o Three-Conductor (Line, Neutral, Ground)  
o Type SV (stranded Vacuum Rubber Jacketed) or SJ (stranded Junior  
Rubber Jacketed) or SVT (Stranded Vacuum Rubber Jacketed  
Thermoplastic) or SJT (Stranded Junior Thermoplastic)  
• The plus must be earth-grounded with a NEMA 5-15 (15A, 125V) or NEMA  
6-15P (15A, 250V) configuration  
Europe  
Switzerland  
• The supply plug must comply with SEV/ASE 1011  
Denmark  
• The supply plug must comply with section 108-2-D1, standard DK2-1a or  
DK2-5a  
United Kingdom  
• The Midspan is covered by General Approval (section 16.16.060,  
NS/G/12345/J100003, for indirect connection to a public  
telecommunication system  
France and Peru  
• IT equipments cannot power this device. In the case of an IT powered  
device, the unite needs to be powered by 230V through an isolation  
transformer with a ratio of 1:1 and the secondary connection (Neutral) is  
properly grounded  
• The Midspan must have access to a nearby power outlet. By disconnecting the power cord  
from the outlet, you will eliminate power from the device.  
• The flexible cord that connects to the Midspan must have a configuration to connect with an  
EN60320/IEC320 inlet connector.  
• According to the EN60950/IEC 950 specifications this device functions under SELV (Safety  
Extra Low Voltage) conditions. The conditions are true if the equipment and the connected  
device functions under SELV conditions.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-15-  
Power up Midspan:  
In order to power up your midspan insert an AC power cord into the appropriate connector on the rear  
of your midspan. Once the cord is connected to a universal or redundant power source the midspan  
will turn on.  
With AC power applied, the unit starts-up and all LEDs should illuminate. The device runs through  
a quick power-on test, which takes a couple of seconds. During this period, all ports are initially  
disabled and the port indicators light up. After completing the cold start, ports will operate under  
normal conditions and the unit is ready to connect to powered devices.  
2.5  
LED Indicators:  
Port LED:  
Model POE75U-1UP-N-R has three LED indicators labeled “ON”, “FAULT”, and “CONNECT”. The  
“ON” LED will illuminate a solid green to indicate that the AC connection is good and that unit is  
sufficiently powered. The “CONNECT” LED will illuminate solid green if it detects a device that requires  
more than 33.6W of power (12.5K-resistance). The “CONNECT” LED will illuminate a blinking green if  
it detects a device requiring less than 33.6W of power (25K resistance) and will power in IEEE802.3at  
mode. Should a fault occur with the connections; the yellow Fault LED will blink till the error is resolved.  
For a full description of the LED diagnostics, please review the individual product datasheet on www.  
phihong.com or www.midspans.com.  
For the series of multiport midspans, for each port the left LED (as viewed from front) will be blinking  
(green) if 25K-resistance load is detected, meaning that the powered device requires less than 33.6W  
of power and the midspan has powered in “IEEE802.3at mode”. The LED will illuminate in solid green  
if the powered device requires more than 33.6W of PoE and the midspan has powered up in Full  
Power mode. The right LED will blink Yellow if a fault has occurred with the connection. No LEDs will  
illuminate if the port is not connected.  
NIC LED:  
If both LEDs are off, it indicates that Midspan is disconnected from the network.  
If the green LED is illuminated and the orange LED blinks, it indicates the Midspan is properly connected  
to the network.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-16-  
2.6  
Technical Specifications  
Model Name:  
-N-R  
POE  
U-  
RoHS  
Power over Ethernet  
NIC Interface  
2-3 digits specifying the  
total power rating  
2 letters specifying the  
power level per port  
1-2 digits specifying the  
total number of output  
ports  
General Eletrical Specifications:  
• Input  
AC Input Voltage Rating  
AC Input Voltage range  
AC Input Current  
100VAC to 240VAC  
90VAC to 264VAC  
Varies per model  
47Hz to 63Hz  
AC Input frequency  
Max. In-rush current  
30A for 115VAC at Max. load  
60A for 230VAC at Max. load  
• Output  
POE125U-  
4AT-N  
POE75U-  
1UP-N  
POE240U-  
2MP-N  
POE240U-  
4UP-N  
POE576U-  
8UP-N  
POE576U-  
4MP-N  
POE806U-  
8MP-N  
Nominal DC Output Voltage  
56V  
33.6W  
0.6A  
56V  
75W  
56V  
56V  
Output Power per Port  
60W  
56V  
56V  
56V  
95W  
95W  
75W  
95W  
Maximum Current per Port  
1.339A  
1.696A  
1.071A  
1.339A  
1.696A  
1.696A  
• Detection Resistance  
POE125U-  
4AT-N  
POE75U-  
1UP-N  
POE240U-  
2MP-N  
POE240U-  
4UP-N  
POE576U-  
8UP-N  
POE576U-  
4MP-N  
POE806U-  
8MP-N  
25K  
12.5K and 25K (both)  
For detailed specifications, refer to the datasheets posted on www.phihong.com or www.midspans.com  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-17-  
3
Midspan Monitoring and Control - HTTP Protocol  
Use Cat5e cables or better to connect both PC and Midspans to the network as follows:  
Figure 18: Management Set-up Diagram  
3.1  
Port Control Webpage  
Enter the hostname in the address bar of your internet browser (The default value of hostname is  
phihong-xxxxxx, where xxxxxx is the last 6 letters of the Midspan’s MAC address found on the  
midspan’s label), then enter the username and password in the login screen. The default username  
and password are both “admin”. Users should note that when creating their new username and  
password both are case sensitive. The Port Control Webpage will be displayed as follows:  
Figure 19: Port Control Webpage  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-18-  
Model Name:  
This can be found in the upper left corner of the Port Control page.  
Heartbeat:  
The Heartbeat is a diagnostic tool to assess the quality of the connection between the midspan and  
the network. A blinking blue “Communication Okay” will indicate that the midspan is connected to  
the network and that data is being relayed correctly. Should a fault occur with the connection; the  
blinking will stop and a solid red “Communication Lost” will appear on the screen.  
Hostname, IP address, Firmware version and MAC address display:  
These can be found on the first row of the table located in the middle of the Port Control Page.  
Menu:  
The menu on the left side of webpage consists of Port Control and Configuration Settings including:  
Administrative Management, Network, SNMP, System Tools and Logout. These will be explained in  
detail later in this manual.  
Help Info:  
Located in the lower right hand corner of the screen, users may click the Help Info icon to obtain  
contact information for technical support. Users may also find support documents and contact  
information on www.midspans.com and www.phihong.com.  
Print Tools:  
To the left of the Help Info icon is the Print Tools icon. Clicking on this icon will print the current  
webpage. The default printer must be on the same network as the midspan in order to use this  
function.  
Phihong webpage:  
Clicking on any of the Phihong logos will link directly to www.phihong.com, where the detailed  
information for all Phihong products, including support information and datasheets, can be found.  
Port Monitoring and Control:  
At the center of the Port Control webpage, there is a table for the user to monitor and control port  
status.  
• Click on the control button “On” in each row, the corresponding port Output-LED will be turned  
on if connected to a valid load, or it will display “No Connection”.  
• Click on the control button “Off” in each row, the corresponding port Output-LED will be turned  
off.  
• Click on the control button “Cycle” in each row to reset that port, if the corresponding port Output-  
LED is already on (or No Connection), it will be turned off for several seconds and then turned on  
again (or No Connection). If the Output-LED is off, it will be turned on (or No Connection).  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-19-  
• Click the button Enable All Ports below the table, the port Output-LEDs will be turned on if  
connected to a valid device or it will display a status “No Connection” if a port is not connected  
to a valid end device.  
• Click the button Disable All Ports below the table, all port Output-LEDs will be turned off.  
• Click the button Cycle All Ports in the last row, all port Output-LEDs will follow one of the following  
actions: If the ports are already “ON” then the ports will be “On” (or No Connection) » Off »  
Turning On… » On (or No Connection). If all ports start turned off then the sequence will be Off  
» Turning On… » On (No Connection), depends on their original states.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-20-  
3.1  
Administrative Management  
Clicking Admin Management under the Configuration menu will bring you to the following page. From  
here the user can choose their own username and password to login to their Phihong Midspan web  
controller. Enter in the new username and password in the corresponding box and click on the Save  
button. Remember to write down your new login information in a safe place for reference. If you forget  
your login information, please review Section 7 – Frequently Asked Questions.  
• Both the username and the password must have a character length of 5 – 30 inclusive.  
• Valid characters include: 0-9, A–Z, and !@#$%^&*()-_+~?<>,.  
Figure 20: Administrative Management Webpage  
3.3  
Network Settings  
Clicking on the Network button under the Configuration menu will direct to the Network Settings page.  
This webpage allows the user to change the midspan’s hostname and configure network settings.  
Change hostname:  
A user may select any character from the keyboard for a hostname up to 15 characters maximum. Any  
extra characters entered will be truncated. Click on the Save button to save your new hostname or  
new network settings if they are acceptable, and you will be directed to the Reboot webpage.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-21-  
Configure network settings:  
WARNING: Only the network administrator is allowed to perform this configuration.  
Network settings on your midspan can be re-configured. Users can choose DHCP, where the midspan  
will be automatically assigned an IP address by the network. The alternative option is to choose Static  
which allowing the user to customize the IP address, IP Subnet Mask, Default Gateway, Primary DNS  
and Secondary DNS. Users need to be aware that any incorrect settings will cause your midspan to  
lose a valid network connection or may upset your network’s normal operation.  
Figure 21: Network Settings Webpage  
After clicking the Save button, a Reboot page (shown below) will be displayed to inform the user that  
the Midspan needs to reboot in order to update for the new settings. The Reboot webpage will also  
display instructions regarding reconnection.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-22-  
Figure 22: Reboot Webpage  
3.4 SNMP Community String  
Click SNMP under the Configuration menu to be directed to the SNMP Community String settings  
page. Phihong’s midspans allow users to change the SNMP Read-Only Community String and Read-  
Write Community String. SNMP community string is a security feature. Only those nodes sharing the  
same community strings in a network may participate in a communication exchange.  
The maximum length of the community string is 30 characters. When the new community string is  
entered, click the Save button to allow the midspan to reboot for the new settings.  
Figure 23: SNMP Community String  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-23-  
3.5  
System Tools  
This System Tools webpage allows user to execute the following 3 tasks:  
1. Upload Firmware  
Upload the binary file POEB-x.x.x.bin (web/SNMP image) into the midspan‘s internal EEPROM  
directly. Note that if a new version of firmware is released, in order to update, you first must use the  
Windows TFTP command to upload POEA-x.x.x.bin into the midspan‘s internal microprocessor,  
then upload POEB-x.x.x.bin. Please review Chapter 5: Firmware Updating at Field for more details  
regarding TFTP uploading.  
To upload web/SNMP image, using the Browser button to locate file POEB-x.x.x.bin, then click on  
the Upload button. If the upload is successful, a new page will display the message <Software  
Update Successful>. Click on the link referencing the site main page to be redirected to the newly  
updated controller.  
2. Reboot Midspan.  
In addition to the Reboot button, there is an input-box for time associated with the Reboot button.  
The Seconds input-box specifies the time for the boot loader to wait for a TFTP firmware upload  
after a power reset. Read Chapter 5: Firmware Updating at Field for more details regarding a TFTP  
upload.  
Choose 0 seconds for a normal reboot. If you have uploaded the POEA-x.x.x.bin via TFTP boot  
load, then a value of at least 6 must be input prior to clicking the Reboot button, then the page will  
be redirected to the Reboot webpage. Note that the POE ports will be turned off while the boot  
loader is waiting for an upload, however, if a reboot of 0 seconds (fast reset) is selected, the power  
across the ports in use will not experience any interruption.  
3. Restore Defaults.  
The Restore Defaults button restores midspan to the factory defaults, and redirects the user to the  
Rebooting page.  
Review the following default settings for your Phihong midspan.  
hostname: phihong-xxxxxx where ‘xxxxxx’ is the last 6 characters of the midspan’s MAC address.  
user name: admin (case sensitive)  
password: admin (case sensitive)  
DHCP: enabled  
read-write community: Phihong  
read-only community: Phihong-read-only  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-24-  
Figure 24: System Tools Webpage  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-25-  
4.  
Midspan Monitoring and Control through MIB Browser --- SNMP Protocol  
Simple Network Management Protocol (SNMP) is used most commonly in network management  
systems to monitor network-attached devices for remote diagnostics. Users can monitor and control  
Phihong midspans using the SNMPv2c protocol. There are many SNMP consoles available, with very  
little difference between them; Phihong leaves the final choice to user preference. Users may obtain  
all the SNMP MIB information shown in this manual in a txt file found in the support sections of our  
websites: www.midspans.com and www.phihong.com.  
4.1  
Structure of Management Information (SMI) for Phihong Midspans  
Figure 25: Phihong Midspan SMI  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-26-  
Figure 26: Phihong Midspan SMI Continued  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-27-  
4.2  
Phihong Midspan MIB  
The following table shows the OID, Name, Type, Value, and Description of Phihong Midspan MIB.  
Phihong USA Corp. registered PEN (Private Enterprise Number) is 1.3.6.1.4.1.24852  
SNMP Version: SNMPv2c (Simple Network Management Protocol Version 2 Community-based) TCP,  
UDP Port: 161.  
OID  
Name  
Type  
Value  
Descrip-  
tion  
phihong.poe.product (1.3.6.1.4.1.24852.1)  
1.3.6.1.4.1.24852.1.1.1  
name  
Read-  
Only  
DisplayString  
Display the  
name of  
this MID  
(Phihong  
SNMP MIB)  
1.3.6.1.4.1.24852.1.1.2  
1.3.6.1.4.1.24852.1.1.3  
version  
Read-  
Only  
DisplayString  
DisplayString  
Display  
the current  
Phihong  
Midspan  
firmware  
version  
date  
Read-  
Only  
Display  
the date  
when the  
current MIB  
updated  
phihong.poe.snmp (1.3.6.1.4.1.24852.1.2)  
1.3.6.1.4.1.24852.1.2.2 snmpAgentReadOnlyCommunity  
Read-  
Write  
DisplayString  
DisplayString  
SNMP  
community  
string tor  
Read  
1.3.6.1.4.1.24852.1.2.3 snmpAgentReadWriteCommunity Read-  
Write  
SNMP  
community  
string for  
Write  
1.3.6.1.4.1.24853.1.2.4  
1.3.6.1.4.1.24852.1.2.5  
snmpTrapHost  
Read-  
Write  
DisplayString  
DisplayString  
The IP of  
Host to  
receive Trap  
snmpTrapcommunity  
Read-  
Write  
SNMP  
Community  
string for  
trap  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-28-  
phihong.poe.network (1.3.6.1.4.1.24852.1.3)  
1.3.6.1.4.1.24852.1.3.1  
dhcp  
Read-  
Write  
enable(1);  
disable(0)  
Enable or  
disable  
DHCP  
1.3.6.1.4.1.24852.1.3.2  
1.3.6.1.4.1.24852.1.3.3  
inAddr  
ipMask  
Read-  
Write  
IpAddress  
IpAddress  
Read or set  
static IP  
Read-  
Write  
Read or  
change IP  
Mask  
1.3.6.1.4.1.24852.1.3.4  
defaultGateway  
Read-  
Write  
IpAddress  
Read or  
change  
Default  
Gateway  
1.3.6.1.4.1.24852.1.3.5  
1.3.6.1.4.1.24852.1.3.6  
primaryDNS  
Read-  
Write  
IpAddress  
IpAddress  
Read or  
change Pri-  
mary DNS  
secondaryDNS  
Read-  
Write  
Read or  
change  
Second  
DNS  
1.3.6.1.4.1.24852.1.3.7  
saveNewSettings  
Write-  
Only  
Integer (0 -- 25) (1). Reboot  
device and  
vaildate  
the new  
settings.  
(2). Specify  
the waiting  
seconds  
(0 - 255) for  
TFTP.  
phihong.poe.control (1.3.6.1.4.1.24852.1.4)  
1.3.6.1.4.1.24852.1.4.1  
firmwareVer  
Read-  
Only  
DisplayString  
Display  
current  
firmware  
version  
1.3.6.1.4.1.24852.1.4.2  
1.3.6.1.4.1.24852.1.4.3  
macAddr  
hostname  
Read-  
Only  
DisplayString  
DisplayString  
Display  
units MAC  
address  
Read-  
Write  
Read or  
change the  
hostname  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-29-  
1.3.6.1.4.1.24852.1.4.4  
1.3.6.1.4.1.24852.1.4.5  
1.3.6.1.4.1.24852.1.4.6  
1.3.6.1.4.1.24852.1.4.7  
username  
password  
Read-  
Write  
DisplayString  
DisplayString  
Read or  
change the  
username  
for web  
Read-  
Write  
Read or  
change  
password  
for web  
restore  
Write- restoreDefaults(1)  
only  
Restore  
factory  
default  
settings  
portsInSystem  
Read-  
Only  
Integer (1 --8)  
Display  
the port  
number in  
device  
1.3.6.1.4.1.24852.1.4.8  
1.3.6.1.4.1.24852.1.4.9  
1.3.6.1.4.1.24852.1.4.10  
1.3.6.1.4.1.24852.1.4.11  
1.3.6.1.4.1.24852.1.4.12  
1.3.6.1.4.1.24852.1.4.13  
1.3.6.1.4.1.24852.1.4.14  
1.3.6.1.4.1.24852.1.4.15  
1.3.6.1.4.1.24852.1.4.16  
Port1Ctr  
Port1Out  
Port2Ctr  
Port2Out  
Port3Ctr  
Port3Out  
Port4Ctr  
Port4Out  
Port5Ctr  
Read-  
Write  
Port1  
control: ON;  
OFF; N/A  
Read-  
Only  
Port1  
output: ON;  
OFF; N/A  
Read-  
Write  
Port2  
control: ON;  
OFF; N/A  
Read-  
Only  
Port2  
output: ON;  
OFF; N/A  
on(1);  
off(0);  
na(63);  
Read-  
Write  
Port3  
control: ON;  
OFF; N/A  
Read-  
Only  
Port3  
output: ON;  
OFF; N/A  
Port4  
control: ON;  
OFF; N/A  
Read-  
Write  
Read-  
Only  
Port4  
output: ON;  
OFF; N/A  
Read-  
Write  
Port5  
control: ON;  
OFF; N/A  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-30-  
1.3.6.1.4.1.24852.1.4.17  
1.3.6.1.4.1.24852.1.4.18  
1.3.6.1.4.1.24852.1.4.19  
1.3.6.1.4.1.24852.1.4.20  
1.3.6.1.4.1.24852.1.4.21  
1.3.6.1.4.1.24852.1.4.22  
1.3.6.1.4.1.24852.1.4.23  
1.3.6.1.4.1.24852.1.4.24  
1.3.6.1.4.1.24852.1.4.25  
Port5Out  
Port6Ctr  
Port6Out  
Port7Ctr  
Port7Out  
Port8Ctr  
Port8Out  
enableAll  
inhibitAll  
Read-  
Only  
Port5  
output: ON;  
OFF; N/A  
Read-  
Write  
Port6  
control: ON;  
OFF; N/A  
Read-  
Only  
Port6  
output: ON;  
OFF; N/A  
Read-  
Write  
Port7  
control: ON;  
OFF; N/A  
Read-  
Only  
Port7  
output: ON;  
OFF; N/A  
Read-  
Write  
Port8  
control: ON;  
OFF; N/A  
Read-  
Only  
Port8  
output: ON;  
OFF; N/A  
Write-  
Only  
enable(1)  
inhibit(0)  
Enable all  
ports in  
device  
Write-  
Only  
Inhibit all  
prorts in  
device  
1.3.6.1.4.1.24852.1.4.26  
1.3.6.1.4.1.24852.1.4.27  
1.3.6.1.4.1.24852.1.4.28  
1.3.6.1.4.1.24852.1.4.29  
1.3.6.1.4.1.24852.1.4.30  
1.3.6.1.4.1.24852.1.4.31  
1.3.6.1.4.1.24852.1.4.32  
port1Status  
port2Status  
port3Status  
port4Status  
port5Status  
port6Status  
port7Status  
Read-  
Only  
Display  
Port1 status  
Read-  
Only  
Display  
Port2 status  
Read-  
Only  
Display  
Port3 status  
on(0);  
notConnected(1);  
fault(2);  
Read-  
Only  
Display  
Port4 status  
off(3);  
na(63);  
Read-  
Only  
Display  
Port5 status  
Read-  
Only  
Display  
Port6 status  
Read-  
Only  
Display  
Port7 status  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-31-  
1.3.6.1.4.1.24852.1.4.33  
1.3.6.1.4.1.24852.1.4.34  
port8status  
modelName  
Read-  
Only  
Display  
port8 status  
Read-  
Only  
DisplayString  
Display  
devices  
Model  
Name  
4.3 Notes for using Phihong Midspan MIB  
1. Although Phihong midspans using SNMPv2c protocol can also run under a SNMPv1 console with  
the same MIB file, they will not operate with Phihong’s SNMPv3 MIB, as the MIB files are not the  
same.  
2. There is a tree node <network> in Phihong Midspan devices, which allows the network  
administrator to change the settings of dhcpStatus, ipAddr, ipmask, defaultGetway, primaryDNS  
and secondaryDNS. If these settings are changed; the OID <saveNewSettings> must be set at a  
value of “0” to reboot the device and validate the new settings. For other events requiring a system  
reboot, users can also set a value of ‘0’ to <saveNetSettings>, except for a TFTP upload (refer to  
Chapter 5: Firmware updating at field). A TFTP upload requires a value greater than or equal to ‘6’  
to validate the upload.  
3. Although <hostname> should technically be listed under network, we place it into the <control>  
section as it does not need a second step (rebooting) to be validated. <macAddr> which is read-  
only and follows the same rebooting rule, is also in this section.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-32-  
4.4  
Using MG-SOFT MIB Browser to run Phihong Midspan  
As an example, we have detailed instructions on how to operate a Phihong Midspan using the MG-  
SOFT MIB browser. These instructions do not apply to all MIB browsers, please see instructions for  
your specific browser if you don’t want to use this software.  
4.4.1 Generate Phihong-POE-MIB module  
It is assumed that MG-Soft MIB browser is already installed on your PC. For detailed operation  
information, users can get help by choosing from the menu Help » User Manual when the MG-SOFT  
MIB Browser is opened.  
1. Open the MIB Browser and click the Continue button on the Welcome popup window. A Tip  
of the Day window may pop-up for certain options in this browser. Users may choose to click  
the little box in the lower left hand corner to stop these pop-ups.  
2. Click the MIB tab; remove any MIB modules in the “Loaded MIB modules” by highlighting and  
double clicking them.  
3. Under the Action menu - open Run MIB Compiler.  
4. In the MG-SOFT MIB Compiler window, click File then Compile…… then in the Open window,  
browse for and open PHIHONG-POE-MIB.txt (users can get SNMP MIB rev 10/30/09 from the  
support section on either www.phihong.com or www.midspans.com).  
5. If compiling is successful, a Compiled MIB Modules window will be displayed. Click Save All  
and click OK on the Browse for Folder window.  
6. Close the MG-SOFT MIB Compiler window.  
7. In the MG-SOFT MIB Browser window, click the circular arrow button (the middle one of 5  
buttons right below the Loaded MIB modules window). This will update the MIB Browser  
windows’ contents (including the newly compiled MIB module Phihong-POE-MIB).  
8. In the lower window, click the tab MIB Modules. Locate the module < Phihong-POE-MIB >.  
Highlighting and double clicking it will load it into the upper Loaded MIB modules window.  
9. Also locate <RFC1213-MIB> and <SNMPv2-MIB>, load them into the upper Loaded MIB  
modules window.  
10.Now the setup for Phihong’s Midspan SNMP interface is complete.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-33-  
Figure 27: Phihong Midspan SMI Continued  
4.4.2 Contact Remote SNMP Agent  
1. In the MG-SOFT MIB Browser window, select the Query tab. Enter the agent’s hostname or IP  
address into Remote SNMP agent box.  
2. Click the hammer-symbol icon next to the Remote SNMP agent box; ensure all settings are  
as follows: SNMPv2c selected; phihong_read_only is entered in the Read community box,  
phihong is entered in the Set community box or your own custom community strings; Port  
Number: 161.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-34-  
Figure 28: Set SNMP Protocol to contact remote SNMP agent  
3. Click on the SNMP menu then Contact. If contact is successful, in the lower Query Results  
window, it will display a message similar to this:  
Welcome to MG-SOFT MIB Browser Professional SNMPv3 Edition  
Remote address: phihong-123456 port: 161 transport: IP/UDP  
Local address: 192.168.31.124 port: 1301 transport: IP/UDP  
Protocol version: SNMPv2c  
1: sysUpTime.0 (TimeTicks) 0 days 02h:28m:06s.59th (888659)  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-35-  
4.4.3 Test for Phihong Midspan SNMP Agent  
1. Expand the MIB menu as shown below and locate the <Phihong> node, then continue to expand  
to the 4 sub-nodes: product, snmp, network and control as shown in Fig. 28.  
Figure 29: Phihong Midspan MIB Tree  
2. Highlight the <phihong> node and click the SNMP menu then Walk. It will display all readable  
Control values.  
3. ToeditavalueforwriteableControls:hostname, username, password, restore, portxCtr, enableAll,  
and inhibitAll; highlight the individual control, then use Set under the SNMP menu to give each  
control a value. Please refer to Phihong’s Midspan MIB table for the list of assigned values. After  
entering the control value, click on the “Set Value” icon in the upper left-hand corner (Set –xxxxxx.0  
window) to validate the WRITE.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-36-  
4. To read individual Control values, highlight the individual control, then click Get under the SNMP  
menu to read values from the highlighted control.  
5. Change network setting:  
WARNING: Only network administrator is allowed to alter this configuration.  
Network settings on the Phihong midspan can also be re-configured using your MIB Browser.  
Users can enable DHCP to allow the network to assign an IP for the midspan automatically, or  
disable DHCP and configure ipAddr, ipMask, defaultGetway, promaryDNS and secondaryDNS.  
Remember entering <saveNewSettings> is required to fix the new settings. Incorrect settings may  
cause your midspan to lose its network connection or crash your network’s normal operation.  
6. Trap operation (POE port status change notifications)  
SETUP:  
a. Expand the MIB Tree to: iso/org/dod/internet/private/enterprises/phihong/poe/snmp.  
b. Highlight <snmpTrapHost>, click Set under the SNMP menu. Entering your PC’s IP  
address in xxx.xxx.xx.x format. (You can get your PC’s IP address by entering <ipconfig>  
in the Command Prompt window). Click the icon in the upper left hand corner in the Set –  
snmpTraphost.0 window to save the settings.  
Figure 30: Set IP Address of Trap Reciever  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-37-  
Operation:  
Notifications occur whenever a port status is changed.  
Connecting or disconnecting a powered device while the unit is “ON”, or turning portxCtr ON or OFF  
will cause a SNMP Trap Ringer Console window to pop up displaying the change. Click an individual  
trap event on the left side of the window, the detailed trap info will display on the right. Checking the  
Pause checkbox will stop trap reporting and un-checking it resume trap reporting. To clear the Trap  
Ringer Console, click the second icon from the left.  
Notes:  
If the TRAP receiver IP address is properly set but no notifications are received, a probable cause is  
that the Windows Firewall is blocking the TRAP UDP Port 162. To open this TRAP port, execute:  
Start » Control Panel » Windows Firewall » then select <Exceptions>. If the Firewall is ON, click <Add  
Port…> button, check radio button <UDP>, enter a Name (for example: SNMP TRAP) and set the port  
number as 162.  
Also check any other firewall on your network that might be blocking the network traffic on UDP Port  
162.  
Figure 31: Trap Ringer Console (Notification)  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-38-  
5.  
Field Firmware Updating  
Phihong is continuously updating our firmware to improve our systems. To ensure that you have the  
most up-to-date firmware, please check with the support section of our websites: www.phihong.com  
or www.midspans.com. Updates can be made from the user’s PC by installing two essential pieces  
of software: POEA-x.x.bin and POEB-x.x.bin where x.x is the version number of the firmware. POEA-  
x.x.bin is the main firmware to be loaded into internal microprocessor, while POEB-x.x.bin needs to be  
loaded into internal EEPROM.  
Update POEA-x.x.bin before updating POEB-x.x.bin.  
The MIB is a pure SNMP interface and used to generate the Phihong-POE-MIB.smidb module. To  
update the Phihong-POE-MIB.smidb module, refer to your SNMP console User Manual (See chapter  
<4.4.1 Generate Phihong-POE-MIB module> to review this method using the MG-SOFT MIB Browser).  
Some updating may only need 1 or 2 steps, based on any new firmware requirements as they become  
available.  
5.1. Updating Microprocessor Flash Contents with POEA-x.x.bin  
The boot loader inside the Midspan is used to upload POEA-x.x.bin into the internal microprocessor  
under Windows’ TFTP command. Windows XP always includes the TFTP utility. However, on Windows  
Vista the TFTP utility must be added by setting Control Panel » Programs and Features » Turn windows  
features on or off » TFTP client.  
There are two “modes” in which the boot loader can listen for a TFTP firmware upload.  
TFTP uploading (Application Entry Mode)  
For normal network/internet/SNMP operations, users may use this Application Entry Mode to manage  
TFTP uploading.  
1. Power up the ready-to-upgrade POE unit and connect it to the Ethernet network. Make sure that  
its TCP/IP feature is functioning. The boot loader will use its TFTP, ARP and ICMP services.  
2. Open the Command Prompt Console by clicking Start » Programs » Accessories » Command  
Prompt.  
3. In the Command Prompt Console, type:  
Tftp:phihong-xxxxxx put “C: \......\POEA-x.x.bin” as shown in the Fig. 5-1, make appropriate  
Hostname/IP Address and file path changes, do not execute the TFTP command yet.  
4. Because the boot loader always listens for 6 seconds after power-on for a TFTP firmware upload,  
an appropriate waiting time must be set for after a reboot. Open web » System Tools and in the  
same screen, enter a value greater than or equal to 6, in the box on the right of the Reboot button  
(or Open SNMP …./network/, click on the OID <saveNewSettings>, set a value 6).  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-39-  
Figure 32:TFTP Uploading using Application Entry Mode  
5. Reboot the midspan by clicking the Reboot button in the web controller (or clicking the first icon  
on the upper left hand corner in Set – xxxxxx.0 window to validate the Set value for the SNMP  
interface). Then quickly switch to the Command Prompt Console to execute TFTP.  
6. If successful, the TFTP client will indicate how long the transfer took as well as the transfer rate.  
7. After a successful write, the boot loader will quit after a few seconds and the POE unit will start to  
execute the new application that was just loaded.  
If the boot loading process is interrupted due to a network failure or user cancellation, the boot loading  
may be resumed by simply retrying the TFTP command, provided the power is not cycled. However,  
if the boot loading operation is interrupted due to power failure, the boot loading must be recovered  
using the following TFTP Power-On Reset Entry Mode.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-40-  
TFTP uploading (Power-On Reset Entry Mode)  
If a valid main firmware is not loaded or a power failure occurred during TFTP uploading Application  
Entry Mode, then the TFTP uploading Power-On Reset Entry Mode must be used. In this mode, the  
Midspan device must use a default IP address 10.0.2.5 with a Subnet mask of 255.255.255.0 for a  
TFTP upload. The procedure is as follows:  
1. Configure the PC as a Static Mode by setting Start » Settings » Network Connections » Local  
Area Connection » Properties » Internet Protocol (TCP/IP). In the Internet Protocol (TCP/IP)  
Properties window, set a static IP as shown in Fig. 32.  
Figure 33: Set static IP in Internet Protocol (TCP/IP) Properties window  
2. Connect the midspan directly to the PC with a Cat5e cable (An older PC may need a crossover  
Cat5 cable.)  
3. In the Command Prompt Console, type the following command but do not execute it:  
tftp 10.0.2.5 put “C: \......\POEA-x.x.bin” , make all the appropriate file path changes.  
4. Power up the midspan. If the device is already powered, turn it off by unplugging it for several  
seconds, and then reconnect it to a power source.  
5. Once the green LED on management RJ45 port blinks 3 times, quickly press Enter to run the TFTP  
command. It must be executed at the right moment as soon as the power turns on.  
6. After a successful TFTP boot loading process, restore your PC’s Internet Protocol (TCP/IP) settings  
to <Obtain an IP address automatically> and < Obtain DNS server address automatically > to  
allow normal network activity.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-41-  
5.2. Updating EEPROM Contents with POEB-x.x.bin  
After the POEA-x.x.bin update is complete, the web/SNMP interface image POEB-x.x.bin needs to be  
uploaded into the internal EEPROM. There are two methods to updating the POEB-x.x.bin.  
Method One:  
In the address bar of your internet browser, enter http://hostname/upload, where hostname is the  
string corresponding to the Midspan IP address. Then use the Browse... button (see Fig.5.3 Upload in  
Internet Explorer) to locate the file POEB-x.x.bin, then click the Upload button.  
Figure 34: Upload in Internet Explorer  
If the EEPROM is successfully updated, <Software Update Successful > will be displayed in a new  
window. Click on Site main page to open the main controller.  
Figure 35: Software Update Successful Window  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-42-  
Method Two:  
User can also use the Software Upgrade function in the main controller. Select Browser… and locate  
the file then click the Upload button on web/System Tools to update EEPROM.  
Figure 36: Upload Using System Tools on Web Interface  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-43-  
6.  
Troubleshooting  
If problems occur with the midspan, check the following troubleshooting table:  
The troubleshooting solutions provided can only solve minor problems. If your problem is not listed,  
please contact our Phihong directly for further technical assistance. All up-to-date contact information  
can be found on our website www.phihong.com or www.midspans.com.  
Troubleshooting  
Problem  
Possible Solutions  
1. Ensure that the AC ppower cord is connected  
2. Ensure that the AC power cord is in good  
condition  
Midspan does not power up  
3. If solutions 1 and 2 are true; then disconnect  
the AC power cord and reconnect. Observe  
the Port LEDs to verify a proper power up.  
1. The Port may be disabled and needs to  
be enabled using either the web or SNMP  
interfaces. Ensure that the Port in question is  
Enabled  
Port LEDs do not illuminate “Green”  
2. Ensure the NIC Port is properly connected to  
the Network  
Use the default IP address 10.0.2.5 and connect  
the midspan to the PC directly. Refer to the  
section TFTP uploading (Power-On Reset Entry  
Mode) for more details. If 10.0.2.5 will not open  
the correct webpage, check the network for any  
possible faults.  
The web interface won’t open or cannot  
contact the unit via SNMP  
The web does not update the port status  
SNMP can’t make contact  
Execute System Tools » Reboot  
Check to see if the community strings are correct  
1. Make sure the power is applied to the midspan  
2. Make sure the network ethernet cable is not  
connected to the POE Data and Power port  
3. Make sure the Data and Power cable is not  
connected to the Ethernet (NIC) power  
For all other issues, please verify the following:  
4. Ensure the proper type of Ethernet cable is  
used. Do not use a crossover type of Ethernet  
cable.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-44-  
7.  
Frequently Asked Questions  
Q1: What should I do if I forgot the hostname?  
A1: You can connect the Midspan to your PC directly, use default IP 10.0.2.5 to open the web or make  
SNMP contact (see details in section TFTP uploading (Power-On Reset Entry Mode). You can  
find the hostname in the web display or read the contents of the OID <hostname> in SNMP.  
Q2: What should I do if I forgot the login username and password?  
A2: If you still know the SNMP community strings, open the SNMP interface and set a value ‘1’ for  
the OID <restore>, the midspan restores itself to the factory defaults. You can reset with your new  
login username and password.  
Q3: What should I do if I forget the SNMP community strings?  
A3: If you still know the web login username and password, open System Tools in the web interface,  
click on the Restore Defaults button. Your midspan will restore to its factory default settings.  
You can reset your new Read-Write Community String and Read-Only Community Strings on the  
SNMP webpage.  
Q4: What should I do if I forgot both login credentials and SNMP community strings?  
A4: Please contact Phihong Support directly for further information on this topic.  
Q5: There is no Configuration menu on the HTTP webpage, what should I do?  
A5: Make sure that your web browser is compatible with the ones listed below. If it is not then upgrading  
would be the best solution.  
Q6: My PC has Internet Explorer 7. After I use the Reboot function under the menu Configure/  
System Tools three times, the hostname link on Reboot page doesn’t work anymore.  
A6: Close the browser and re-open a new window. This is a known limitation with the Internet Explorer  
7 program. There are no other known restrictions on IE7 at this time. You can also upgrade your  
Internet Explorer to latest version IE8. Other compatible web browsers include Firefox, Opera,  
Google Chrome, and Safari.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-45-  

相关型号:

POE576U-8UP-N-R

Phihong Midspan POE with TCPIP (SNMPv2c)
PHIHONG

POE600F-12LB

60 W PoE Transformers
COILCRAFT

POE600F-12LD

60 W PoE Transformers
COILCRAFT

POE600F-24LB

60 W PoE Transformers
COILCRAFT

POE600F-24LD

60 W PoE Transformers
COILCRAFT

POE600F-33LB

60 W PoE Transformers
COILCRAFT

POE600F-33LD

60 W PoE Transformers
COILCRAFT

POE600F-50LB

60 W PoE Transformers
COILCRAFT

POE600F-50LD

60 W PoE Transformers
COILCRAFT

POE600F_15

60 W PoE Transformers
COILCRAFT

POE60C-12L

Miniature Flyback Transformers for PoE
COILCRAFT

POE60C-12LB

Miniature Flyback Transformers for PoE
COILCRAFT