1309695 [PHOENIX]
AC charging controller - CHARX SEC-3150;型号: | 1309695 |
厂家: | PHOENIX CONTACT |
描述: | AC charging controller - CHARX SEC-3150 |
文件: | 总7页 (文件大小:77K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
https://www.phoenixcontact.com/us/products/1138965
AC charging controller - CHARX SEC-3150 - 1138965
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
CHARX control modular, AC charging controller according to IEC 61851-1, ISO/IEC 15118. Embedded Linux
system. operating mode Stand-alone, server, or client. interface: Ethernet (2x), Cellular communication (4G/2G),
CHARX control modular system bus, MICRO-USB type C. communication protocol: OCPP 1.6J, Modbus/TCP,
MQTT. Connectable peripheral devices: Energy meter, RFID, DC residual current detection. DIN rail mounting
Key Commercial Data
Packing unit
1
GTIN
GTIN
4063151080389
85371091
Custom tariff number
Technical data
Product definition
Type
Embedded Linux system
IEC 61851-1
Standards/regulations
ISO 15118
Charging standard
IEC 61851-1
ISO/IEC 15118
Mode 3, Case B + C
CE-compliant
Charging mode
Conformance
Dimensions
Height
Width
Depth
121 mm
37.6 mm
85.00 mm
Ambient conditions
09/27/2021 Page 1 / 7
https://www.phoenixcontact.com/us/products/1138965
AC charging controller - CHARX SEC-3150 - 1138965
Technical data
Ambient conditions
Ambient temperature (operation)
Ambient temperature (storage/transport)
Permissible humidity (operation)
Permissible humidity (storage/transport)
Air pressure (operation)
Air pressure (storage/transport)
Degree of protection
-25 °C ... 65 °C
-40 °C ... 80 °C
5 % ... 95 % (non-condensing)
5 % ... 95 % (non-condensing)
70 kPa ... 106 kPa (up to 3000 m above mean sea level)
58 kPa ... 106 kPa (up to 4500 m above mean sea level)
IP20
Degree of pollution
2 in acc. with IEC 60664-1
Overvoltage category
III
Shock (operation)
Shock in acc. with EN 60068-2-27/IEC 60068-2-27
15g, 11 ms period, half-sine shock pulse
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
5g, 10...150 Hz, 2.5 h, in XYZ direction
Test specification
Vibration (operation)
Test specification
Device supply
Supply voltage
12 V DC
Supply voltage range
Max. current consumption
No-load current
11.4 V DC ... 12.6 V DC
2 A (Stand-alone operation)
< 200 mA (without external loads)
System data
Operating system
Processor
Linux
Arm® Cortex®-A7 Single-Core Processor
512 Mbyte (RAM)
RAM
Mass storage
User interface
Security functions
8 GByte (eMMC)
Web-based management
IP, port, protocol
Data interfaces
Interface
Ethernet
2
Number
Connection method
Number of MAC addresses
Transmission speed
Transmission length
Operating mode
RJ45 jack
2
10/100 Mbps
100 m
WAN/LAN
LAN/LAN
OCPP 1.6J
Modbus/TCP
Protocols supported
09/27/2021 Page 2 / 7
https://www.phoenixcontact.com/us/products/1138965
AC charging controller - CHARX SEC-3150 - 1138965
Technical data
Data interfaces
MQTT
HTTP
HTTPS
Interface
Configuration and diagnostics
Number
1
Connection method
Protocols supported
Interface
Micro-USB type C
RNDIS
Energy meters
RS-485
Bus system
9.6 kbps ... 115.2 kbps (Automatic setting in accordance with the selected
energy meter)
Transmission speed
Interface
RFID readers
RS-485
Bus system
9.6 kbps ... 115.2 kbps (Automatic setting in accordance with the selected
RFID reader)
Transmission speed
Interface
CHARX control modular system bus
Number
1
Connection method
DIN rail bus connectors
Wireless interfaces
Interface
Cellular communication
GSM / GPRS / EDGE / LTE (FDD)
800 MHz (LTE B20)
Interface description
Frequency
900 MHz (LTE B8)
1800 MHz (LTE B3)
900 MHz (GSM/GPRS/EDGE )
1800 MHz (GSM/GPRS/EDGE )
50 Ω impedance SMA antenna socket
You will find a suitable antenna in the accessories are for this item
Micro SIM (3FF)
Antenna
Note
SIM card
LTE
CAT1
Country support
Protocols supported
Europe
OCPP 1.6J
Function interfaces
Interface
Vehicle interface
IEC 61851-1
ISO 15118
Communication protocol
GB/T 18487
09/27/2021 Page 3 / 7
https://www.phoenixcontact.com/us/products/1138965
AC charging controller - CHARX SEC-3150 - 1138965
Technical data
Function interfaces
Proximity
IEC 61851-1
GB/T 18487
Charging cases
Control voltage
Rated current
Mode 3, Case B + C
± 12 V (Locking actuator)
2 A
Integrated release function of the locking actuator for disconnection of
Infrastructure Plug and Infrastructure Socket Outlet
Locking release in the event of mains failure
Interface
Residual current detection
Sensor supply voltage
Error state signal level
12 V DC
12 V (Different terminal points)
0 V (Different terminal points)
Test & Reset signal level
Interface
12 V
Temperature monitoring
Sensor type
Pt 1000
PTC chain
Tripping characteristic
Interface
configurable
Contactor control
Interface description
Switching voltage
Floating switch contact
max. 250 V AC (Necessary for ISO 15118 communication)
max. 30 V DC
2 A
Rated current
Interrupting rating
max. 1500 VA
Inputs
Description of the input
Number inputs
Digital input
4
Nominal input voltage UN
Input voltage range
12 V
0 V ... 3 V (Off)
9 V ... 15 V (On)
configurable
Function
Outputs
Output name
Digital output
Number outputs
Operating mode
4
High-Side (Output switched to internal 12 V voltage)
Low-Side (Output switched to GND potential)
12 V (High-side operation)
≤ 12 V (Low-side operation)
Output voltage
Output current
max. 600 mA
09/27/2021 Page 4 / 7
https://www.phoenixcontact.com/us/products/1138965
AC charging controller - CHARX SEC-3150 - 1138965
Technical data
Outputs
Function
configurable
Connection data
Connection technology
pluggable
Push-in technology
0.14 mm² ... 1.5 mm²
0.2 mm² ... 2.5 mm²
0.25 mm² ... 1.5 mm² (with ferrules)
24 ... 16
Conductor cross section solid
Conductor cross section flexible
Conductor cross section
Conductor cross section AWG
Stripping length
8 mm
10 mm (for contactor control)
Classifications
eCl@ss
eCl@ss 11.0
eCl@ss 9.0
27144703
27144703
ETIM
ETIM 7.0
EC002889
Accessories
Accessories
Antenna
Antenna - PSI-GSM/UMTS-QB-ANT - 2313371
GSM UMTS antenna, with omnidirectional characteristic, 2 m antenna cable with SMA round connector
Residual current monitoring module
09/27/2021 Page 5 / 7
https://www.phoenixcontact.com/us/products/1138965
AC charging controller - CHARX SEC-3150 - 1138965
Accessories
Differential current monitoring - EV-RCM-6DC-WAT - 1309697
The residual current monitoring module is used for AC and DC residual current detection in AC charging points. The
higher-level safety equipment (e.g., residual current device) is protected against potential DC residual currents.
Differential current monitoring - EV-RCM-6DC-WAT-X10 - 1309695
The residual current monitoring module is used for AC and DC residual current detection in AC charging points. The
higher-level safety equipment (e.g., residual current device) is protected against potential DC residual currents.
RFID device
RFID device - EV-RFID-ELT-PCB - 1309772
RFID card reader for connection to CHARX control modular charging controllers
RFID device - EV-RFID-ELT-PCB-X10 - 1309752
RFID card reader for connection to CHARX control modular charging controllers
RFID device - EV-RFID-ELT-IP65 - 1309687
RFID card reader for connection to CHARX control modular charging controllers
09/27/2021 Page 6 / 7
https://www.phoenixcontact.com/us/products/1138965
Phoenix Contact 2021 © - all rights reserved
http://www.phoenixcontact.com
09/27/2021 Page 7 / 7
相关型号:
©2020 ICPDF网 联系我们和版权申明