PLUSCON  
PLUSCON circular  
Industrial Circular Connectors  
M16 – M58  
Assembly Instructions  
www.phoenixcontact.com  
Contents  
Page  
Modular Signal Connectors  
M23 – RC Series  
PLUSCON circular  
Cable connectors and cable connecting receptacles  
Panel mounting connectors  
4 – 5  
6
M23 – UC Series, universal shielding  
Cable connectors and cable connecting receptacles  
7 – 9  
Bayonet TU Series  
Cable connectors and cable connecting receptacles  
Panel mounting connectors  
10  
11  
PC Board Layouts  
M23 / Bayonet – RC, UC / TU Series  
12  
13  
Signal Connectors  
PLUSCON circular  
M16 – PV Series  
Panel mounting connectors and PC Board layouts  
M17 – ST Series  
Cable connectors  
Cable connecting receptacles  
Panel mounting connectors  
(see M17 – P20 Series)  
(see M17 – P20 Series)  
(see M17 – P20 Series)  
24 – 25  
26 – 27  
28 – 33  
M23 – RF Series  
Cable connectors  
Cable connecting receptacles  
Panel mounting connectors  
14  
15  
16 – 21  
M27 – HC Series  
Cable connectors, cable connecting receptacles  
and panel mounting connectors  
PC Board layouts  
22  
23  
Power Connectors  
M17 – P20 Series  
PLUSCON circular  
Cable connectors  
Cable connecting receptacles  
Panel mounting connectors  
24 – 25  
26 – 27  
28 – 33  
M23 – P30 Series  
Cable connectors, short/long housing  
Cable connecting receptacles, short/long housing  
Cable connectors and cable connecting receptacles for ext. cable glands  
Wall bushings with mounting flange  
Panel mounting connectors  
Panel mounting connectors with knurled nut  
34 – 35  
36 – 37  
38 – 39  
40 – 41  
42 – 45  
46 – 47  
M40 – P70 Series  
Cable connectors, short/long housing  
Cable connecting receptacles, short/long housing  
Wall bushings with mounting flange  
Panel mounting connectors  
48 – 49  
50 – 51  
52 – 53  
54 – 56  
57 – 59  
Panel mounting connectors with knurled nut  
M58 – P150 Series  
Cable connectors  
Cable connecting receptacles  
Panel mounting connectors  
60  
61  
62  
PHOENIX CONTACT  
3
Modular Signal Connectors – PLUSCON circular  
M23 – RC Series  
Cable connectors and cable connecting receptacles,  
straight, shielded  
Coding groove  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
• Push the adapter (1), the union nut (2) and the sealing • Strip the litz wires by 3.5 mm, twist (and tin plate).  
element (4) with the gasket (3) onto the cable.  
• Strip the external sheath by 23 mm.  
• Detail A: Push back the braided screen such that it  
stands out at 90°. With a rotating motion, push the  
shielded sleeve (5A) over the foil or cotton braiding  
and under the braided screen. Cut the braided screen  
• Solder, crimp or screw the litz wires to the contacts.  
• Insert the spacer sleeve (6).  
• Guide the insert (7) and spacer sleeve (6) into the  
insert sleeve (8), taking care that the desired coding  
groove of the insert (7) is introduced into the coding  
bar.  
flush with the external diameter of the shielded sleeve • Press in the cable with the shield and sealing unit.  
(5A).  
• Screw the adapter (1) as tight as possible.  
Trim the foil, wadding and inner insulation.  
Installation dimensions  
Cable connecting receptacle for wall mounting  
Ø2,7  
M2,5  
Flat gasket  
Axial O-ring  
Radial O-ring  
RC-0000000B2FZ  
(front mounting)  
RC-0000000C0FZ  
(rear mounting)  
RC-0000000Q0FZ  
(rear mounting)  
Cable connectors and cable connecting receptacles with plastic cap,  
straight, shielded  
Coding groove  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
• Push the adapter (1), the union nut (2) and the seal-  
ing element (4) with the gasket (3) onto the cable.  
• Strip the external sheath by 23 mm.  
• Push back the braided screen such that it stands out  
at 90° and cut it flush with the outer diameter of the  
shield disc (5).  
Trim the foil, wadding and inner insulation.  
• Strip the litz wires by 3.5 mm, twist (and tin plate).  
• Solder, crimp or screw the litz wires to the contacts.  
• Insert the spacer sleeve (6).  
• Guide the insert (7) and spacer sleeve (6) into the  
insert sleeve (8), taking care that the desired coding  
groove of the insert (7) is introduced into the coding  
bar.  
• Press in the cable with the shield and sealing unit.  
• Screw the adapter (1) as tight as possible.  
Attention: The required torque must not increase by  
more than 10 Nm during this process, as this can  
effect the free movement of the union nut.  
PHOENIX CONTACT  
4
Modular Signal Connectors – PLUSCON circular  
M23 – RC Series  
Cable connectors,  
angled, shielded  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
Push the adapter (1) and the sealing element (3) with  
the gasket (2) onto the cable.  
• Solder, crimp or screw the litz wires to the contacts.  
• Insert the spacer sleeve (6).  
• Strip the external sheath by 70 mm.  
• Detail A: Push back the braided screen such that it  
stands out at 90°. With a rotating motion, push the  
• Guide the insert (7) and spacer sleeve (6) into the  
unit (8), taking care that the desired coding groove  
of the insert (7) is introduced into the coding bar.  
Coding groove  
shielded sleeve (4A) over the foil or cotton braiding but • Insert the entire unit into the angle housing (Attention:  
under the braided screen. Cut the braided screen flush  
with the external diameter of the shielded sleeve (4A).  
Trim the foil, wadding and inner insulation.  
• Strip the litz wires by 3.5 mm, twist (and tin plate).  
• Pull the cable unit as far as possible through the  
angle housing (5).  
eight coding options) and secure with nut (8A)  
(torque: 10 Nm up to 12 Nm).  
• Press in the cable with the shield and sealing unit.  
• Screw the adapter (1) as tight as possible.  
10 Nm - 12 Nm  
Wrench RC-Z 2099  
Cable connectors and cable connecting receptacles,  
straight, unshielded  
Coding groove  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
• Push the cable screw connection (1), adapter (2) and  
union nut (3) onto the cable.  
• Strip the external sheath by 20 mm.  
Trim the foil, wadding and inner insulation.  
• Strip the litz wires by 3.5 mm, twist (and tin plate).  
• Solder, crimp or screw the litz wires to the contacts.  
• Insert the spacer sleeve (4).  
• Guide the insert (5) and spacer sleeve (4) into the  
insert ring (6), taking care that the desired coding  
groove of the insert (7) is introduced into the coding  
bar.  
• Screw the adapter (2) as tight as possible.  
• Screw the cable gland (1) as tight as possible.  
Cable connectors,  
angled, unshielded  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
• Push the cable screw connection (1), adapter (2) and  
angle housing (3) onto the cable.  
• Strip the external sheath by 30 mm.  
Trim the foil, wadding and inner insulation.  
• Strip the litz wires by 3.5 mm, twist (and tin plate).  
• Solder, crimp or screw the litz wires to the contacts.  
• Insert the spacer sleeve (4).  
Coding groove  
• Guide the insert (5) and spacer sleeve (4) into the unit  
(6), taking care that the desired coding groove of the  
insert (5) is introduced into the coding bar.  
• Insert the entire unit into the angle housing (Attention:  
eight coding options) and secure with nut (6A)  
(torque: 10 Nm up to 12 Nm).  
10 Nm - 12 Nm  
• Screw the adapter (2) as tight as possible.  
• Screw the cable gland (1) as tight as possible.  
Wrench RC-Z 2099  
PHOENIX CONTACT  
5
Modular Signal Connectors – PLUSCON circular  
M23 – RC Series  
Panel mounting connectors,  
angled rotary  
Torx T10 • 1.7 Nm  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
Installation  
dimensions  
RC-0000000AD00  
Solder, crimp or screw the litz wires to the contacts  
and guide them into the insert (3).  
Alternatively:  
Solder, crimp or screw the litz wires to the contacts  
and push them through the housing (1)  
• Push the crimped contacts into the insert (3).  
• Push the spacer sleeve (2) onto the insert (3) and  
position it in the housing (1).  
• Push the cover (4) onto the housing (1) and hook it in.  
• Attach the cover (4) with the screws (5) (Torx T10,  
torque: 1.7 Nm).  
• Push the insert (3) through the housing (1).  
• Push the spacer sleeve (2) onto the insert (3) and  
position it in the housing (1).  
• Push the cover (4) onto the housing (1) and hook it in.  
• Attach the cover (4) with the screws (5) (Torx T10),  
torque: 1.7 Nm  
Edge stripping  
max. 0.2  
Panel mounting connectors,  
straight  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
Installation dimensions  
Panel mounting connectors, front mounting  
Mounting hole with anti-rotation protection  
and counter nut  
(Recommendation for fitting in steel plate)  
Mounting bushing with thread  
(Recommendation for fitting in steel plate)  
Flat gasket  
Radial O-ring  
RC-00000002200 (flat gasket)  
RC-0000000WQ00 (radial O-ring)  
RC-00000006100  
(axial O-ring )  
Installation dimensions  
Panel mounting connectors, rear mounting  
Removing the plastic  
latching ring  
Radial O-ring  
Axial O-ring  
RC-00000004200, RC-00000005200,  
RC-0000000E000  
RC-0000000H000  
PHOENIX CONTACT  
6
Modular Signal Connectors – PLUSCON circular  
M23 – UC Series  
Cable connectors and cable connecting receptacles,  
straight, universal shielding  
Coding groove  
Installation dimensions  
cable connecting receptacles  
for wall mounting  
UC-0000000Q0DU  
UC-0000000Q3DU  
UC-0000000QNDU  
Axial O-ring  
• Push the adapter (1) and the sealing element (3) with • Insert the spacer sleeve (4).  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
the gasket (2) onto the cable.  
• Guide the insert (5), the spacer sleeve (4) and the  
• Strip the external sheath by 30 mm.  
sealing element (3) with the gasket (2) into the insert  
ring (6), taking care that the desired coding groove of  
the insert (5) is introduced into the coding bar of the  
spacer sleeve (6).  
• Push back the braided screen so it stands out at 90°  
and cut to length.  
Trim the foil, wadding and inner insulation.  
• Screw the adapter (1) as tight as possible.  
• Strip the litz wires by 3.5 mm, twist (and tin plate).  
• Solder, crimp or screw the litz wires to the contacts.  
PHOENIX CONTACT  
7
Modular Signal Connectors – PLUSCON circular  
M23 – UC Series  
Cable connectors,  
angled, universal shielding  
Coding groove  
10 Nm - 12 Nm  
• Push the adapter (1) and sealing element (2) onto the • Push crimped contacts into the insert (6).  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
cable.  
• Insert the spacer sleeve (5).  
• Strip the external sheath by 80 mm.  
• Guide the insert (6) and spacer sleeve (5) into the unit  
Trim the foil, wadding and inner insulation.  
(7), taking care that the desired coding groove of the  
insert (6) is introduced into the coding bar.  
• Push back the braided screen so it stands out at 90°  
and cut to length.  
• Insert the entire unit into the angle housing. (Attention:  
eight coding options) and secure with nut (7A) (torque:  
10 Nm up to 12 Nm).  
• Strip the litz wires by 6 mm.  
• Crimp the litz wires to the contacts.  
• Screw the adapter (1) as tight as possible.  
• Push the cable unit through  
the angle housing (4).  
• Insert the spacer sleeve (3) into the angle housing (4).  
• Push the sealing element (2) over the spacer sleeve  
(3) thus clamping the braided screen between sealing  
element and spacer sleeve.  
PHOENIX CONTACT  
8
PHOENIX CONTACT  
9
Modular Signal Connectors – PLUSCON circular  
Bayonet TU Series  
Cable connectors and cable connecting receptacles,  
straight, shielded  
Coding groove  
• Push the adapter (1) and the sealing element (3) with • Insert the spacer sleeve (4).  
the gasket (2) onto the cable.  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
• Guide the insert (5), the spacer sleeve (4) and the  
• Strip the external sheath by 30 mm.  
sealing element (3) with the gasket (2) into the insert  
ring (6), taking care that the desired coding groove of  
the insert (5) is introduced into the coding bar of the  
spacer sleeve (6).  
• Push back the braided screen so it stands out at 90°  
and cut to length.  
Trim the foil, wadding and inner insulation.  
• Screw the adapter (1) as tight as possible.  
• Strip the litz wires by 3.5 mm, twist (and tin plate).  
• Solder, crimp or screw the litz wires to the contacts.  
PHOENIX CONTACT  
10  
Modular Signal Connectors – PLUSCON circular  
Bayonet TU Series  
Cable connectors,  
angled, shielded  
Coding groove  
10 Nm - 12 Nm  
• Push the adapter (1) and sealing element (2) onto the • Push the sealing element (2) over the spacer sleeve  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
cable.  
(3) thus clamping the braided screen between sealing  
element and spacer sleeve.  
• Strip the external sheath by 80 mm.  
Trim the foil, wadding and inner insulation.  
• Push crimped contacts into the insert (6).  
• Insert the spacer sleeve (5).  
• Push back the braided screen so it stands out at 90°  
and cut to length.  
• Guide the insert (6) and spacer sleeve (5) into the unit  
(7), taking care that the desired coding groove of the  
insert (6) is introduced into the coding bar.  
• Strip the litz wires by 6 mm.  
• Solder, crimp or screw the litz wires to the contacts.  
• Insert the entire unit into the angle housing. (Attention:  
eight coding options) and secure with nut (7A)  
(torque: 10 Nm up to 12 Nm).  
• Push the cable unit through  
the angle housing (4).  
• Insert the spacer sleeve (3) into the angle housing (4).  
• Screw the adapter (1) as tight as possible.  
Panel mounting connectors,  
straight  
Installation dimensions  
Panel mounting connectors, front / rear mounting  
Please note: torque for screw termination  
• max. 0.1 Nm for screw contacts with  
mating dia. 1 mm  
• max. 0.2 Nm for screw contacts with  
mating dia. 2 mm  
Axial O-ring  
Removing the plastic  
latching ring  
Radial O-ring  
Flat gasket  
TU-0000000WB00 (axial O-ring )  
TU-00000005300 (radial O-ring )  
TU-00000004100 (flat gasket)  
PHOENIX CONTACT  
11  
Modular Signal Connectors – PLUSCON circular  
Bayonet TU Series  
PC Board layouts (dip solder contacts)  
6-pos.  
9 (6+3)-pos  
9 (8+1)-pos.  
12-pos.  
17-pos.  
No. of positions  
6
9(6+3)  
9(8+1)  
12  
17  
Mating dia. 6 x Ø 2.0 mm 6 x Ø 1.0 mm 8 x Ø 1.0 mm 12 x Ø 1.0 mm 17 x Ø 1.0 mm  
3 x Ø 2.0 mm 1 x Ø 2.0 mm  
Free solder pin length  
ØP dip solder pin  
6 x Ø 0.6 mm 8 x Ø 0.6 mm  
3 x Ø 1.5 mm 1 x Ø 1.5 mm  
A
B
C
D
Ø 1.5 mm  
Ø 1.5 mm  
Ø 1.5 mm  
Ø 1.5 mm  
Ø 0.6 mm  
Ø 1.0 mm  
Ø 1.2 mm  
Ø 1.2 mm  
Ø 0.6 mm  
Ø 1.0 mm  
Ø 1.2 mm  
Ø 1.2 mm  
6 x Ø 1.0 mm 8 x Ø 1.0 mm  
3 x Ø 1.5 mm 1 x Ø 1.5 mm  
6 x Ø 1.2 mm 8 x Ø 1.2 mm  
3 x Ø 1.5 mm 1 x Ø 1.5 mm  
6 x Ø 1.2 mm 8 x Ø 1.2 mm  
3 x Ø 1.5 mm 1 x Ø 1.5 mm  
The free solder pin length A, B, C or D is the distance  
between the mounting flange of the panel mounting  
connector and the end of the dip solder contact. This  
distance includes the housing wall thickness and the air  
gap to the printed circuit board.  
Housing type  
M23  
Free solder pin length  
Housing type  
Free solder pin length  
A
B
[mm]  
C
[mm]  
D
A
B
[mm]  
C
[mm]  
D
Bayonet  
[mm]  
[mm]  
[mm]  
[mm]  
RC-.......2200  
RC-.......WQ00  
RC-.......4200  
RC-.......5200  
RC-.......H000  
RC-.......E000  
3.5  
3.5  
3.5  
3.5  
4.5  
4.5  
4.5  
4.5  
10.0  
10.0  
10.0  
10.0  
3.5  
17.5  
17.5  
17.5  
17.5  
11.0  
11.0  
TU-.......WB00  
TU-.......4100  
TU-.......5300  
9.0  
9.0  
9.0  
16.5  
16.5  
16.5  
2.5  
2.5  
3.5  
3.5  
3.5  
PHOENIX CONTACT  
12  
Signal Connectors – PLUSCON circular  
M16 – PV Series  
Panel mounting connectors straight,  
front/rear mounting  
PV-..P1N126100 (front mounting),  
PV-..P1N.2HG00 (rear mounting)  
PV-..P1N126100  
min. 1,5 mm  
max. 5,0 mm  
Solder connection  
Installation  
dimensions  
PV-..P1N.2HG00  
PV-..P1N22HG00  
min. 1,5 mm  
max. 5,0 mm  
Solder connection  
Dip solder connection  
Installation  
dimensions  
PCB hole patterns, dip solder connection  
Bore dia. 0.8 0.0ꢀ mm  
X
Y
A
C
E
G
J
- 2.5  
- 4.25  
- 2.3  
2.3  
- 4.0  
0.0  
4.0  
4.0  
4.25  
2.5  
0.0  
L
- 4.0  
- 2.4  
- 0.95  
0.95  
2.4  
14-pos.  
12-pos.  
M
N
O
P
R
S
T
- 0.95  
- 2.4  
- 2.4  
- 0.95  
0.95  
2.4  
2.4  
0.95  
- 0.95  
- 2.4  
2.4  
U
0.95  
10-pos.  
8-pos.  
PHOENIX CONTACT  
13  
Signal Connectors – PLUSCON circular  
M23 – RF Series  
7
Cable connectors  
RF-..P..8A80.., RF-..S..8A80..  
RF-..P..8A8V.., RF-..S..8A8V.. (stainless steel housings)  
6
5
5b  
5a  
4
3
6
2
1
5b  
close  
5a  
Pos. 5 and 6: contact carrier open;  
clip the crimp contacts in at the side.  
24  
Assembly drawings show assembly with  
female contacts. The same applies to male  
contacts.  
24  
• Push the adapter (1) and the sealing element (3) with • Crimp the contacts to the conductors. Stripping lengths in the direction of “close”. When locked correctly, the  
the sealing ring (2) onto the cable.  
depend on the contact used; see setting matrix under  
crimping tools.  
Note: The contacts can also be crimped before the  
shield is put on.  
• Clip the contacts into the sides of the contact carrier  
coding grooves form a line and the contact carrier  
(5+6) cannot be separated.  
• Push the shielding block (2+3+4) onto the insulating  
body so that a “unit” is created. Fit the unit in the  
housing (7). Observe the position of the coding groove.  
• Strip the external cable sheath by approx. 28 mm.  
Trim and remove the foil, wadding and inner insulation.  
• Fold the braided screen up backwards. It is not  
necessary to unbraid or cut off the braided screen.  
• Push the metal screen sleeve (4) over the braided  
screen from the front until the right collar of the screen  
sleeve is flush with the cable sheath.  
• Push protruding braided screen up somewhat.  
• Push the unit (2+3) together over the braided screen  
at (4) as far as it will go. The braided screen is thereby  
folded.  
(5). Observe the contact chamber marking. First equip • Screw the adapter (1) tight, torque 7 Nm.  
the inside part (5a) with contacts and push it into the  
outer contact carrier (5b) (observe the marking for  
assistance).  
Turn the ring of the insulating body sleeve (6) to the  
“open” position. Push the unit (5a+5b) into the  
insulating body sleeve (6). Lock (6) by turning the ring  
Stainless steel housings: screw the adapter (1)  
tight to the stop.  
PHOENIX CONTACT  
14  
Signal Connectors – PLUSCON circular  
M23 – RF Series  
7
Cable connecting receptacles  
6
RF-..P..8A90.., RF-..S..8A90..  
RF-..P..8A9V.., RF-..S..8A9V.. (stainless steel housings)  
5
5b  
5a  
4
6
3
2
1
5b  
close  
5a  
Pos. 5 and 6: contact carrier open;  
clip the crimp contacts in at the side.  
24  
Assembly drawings show assembly with  
male contacts. The same applies to female  
contacts.  
24  
• Push the adapter (1) and the sealing element (3) with • Crimp the contacts to the conductors. Stripping lengths in the direction of “close”. When locked correctly, the  
the sealing ring (2) onto the cable.  
depend on the contact used; see setting matrix under  
crimping tools.  
Note: The contacts can also be crimped before the  
shield is put on.  
• Clip the contacts into the sides of the contact carrier  
coding grooves form a line and the contact carrier  
(5+6) cannot be separated.  
• Push the shielding block (2+3+4) onto the insulating  
body so that a “unit” is created. Fit the unit in the  
housing (7). Observe the position of the coding groove.  
• Strip the external cable sheath by approx. 28 mm.  
Trim and remove the foil, wadding and inner insulation.  
• Fold the braided screen up backwards. It is not  
necessary to unbraid or cut off the braided screen.  
• Push the metal screen sleeve (4) over the braided  
screen from the front until the right collar of the screen  
sleeve is flush with the cable sheath.  
• Push protruding braided screen up somewhat.  
• Push the unit (2+3) together over the braided screen  
at (4) as far as it will go. The braided screen is thereby  
folded.  
(5). Observe the contact chamber marking. First equip • Screw the adapter (1) tight, torque 7 Nm.  
the inside part (5a) with contacts and push it into the  
outer contact carrier (5b) (observe the marking for  
assistance).  
Turn the ring of the insulating body sleeve (6) to the  
“open” position. Push the unit (5a+5b) into the  
insulating body sleeve (6). Lock (6) by turning the ring  
Stainless steel housings: screw the adapter (1)  
tight to the stop.  
PHOENIX CONTACT  
15  
Signal Connectors – PLUSCON circular  
M23 – RF Series  
Panel mounting connectors straight  
RF-.....8AWA00, RF-.....8AWQ00  
RF-.....8AWV00, RF-.....8AWU00 (stainless steel housings)  
4
5
M2.5 / M3 (not included in  
the scope of delivery)  
3
3
2
2b  
2a  
2b  
1
close  
2a  
Pos. 2 and 3: contact carrier open;  
clip the crimp contacts in at the side.  
Installation dimensions  
• Crimp the conductors to the contacts and guide them  
through the mounting panel and the ring (1). Stripping  
lengths depend on the contact used; see setting matrix  
under crimping tools.  
Note: The conductors can also be guided through the  
notched ring (1) at a later time.  
• Clip the contacts into the sides of the contact carrier  
(2). Observe the contact chamber marking. First equip  
the inside part (2a) with contacts and push it into the  
outer contact carrier (2b) (observe the marking for  
assistance).  
Turn the ring of the insulating body sleeve (3) to the  
“open” position. Push the unit (2a+2b) into the  
insulating body sleeve (3.) Lock (3) by turning the ring  
in the direction of “close”. When locked correctly, the  
coding grooves form a line and the contact carrier  
(2+3) cannot be separated.  
• Slide the housing (4) onto the unit (2+3).  
• Insert the ring (1) in the housing (4).  
• Fasten the assembled connector to the mounting  
panel using screws (5).  
Assembly drawings show assembly with  
male contacts. The same applies to female  
contacts.  
PHOENIX CONTACT  
16  
Signal Connectors – PLUSCON circular  
M23 – RF Series  
Panel mounting connectors straight,  
contact carrier for snapping in  
3
RF-..P..8AW400, RF-..S..8AW400  
RF-..P..8AWB00, RF-..S..8AWB00  
2
4
M2.5 / M3 (not included  
in the scope of delivery)  
2
1
1b  
1b  
1a  
close  
1a  
Pos. 1 and 2: contact carrier open; clip  
the crimp contacts in at the side.  
Installation dimensions  
• Secure flange connector housing (3) to the mounting  
panel using screws (4).  
• Crimp the conductors to the contacts. Stripping lengths  
depend on the contact used; see setting matrix under  
crimping tools.  
• Clip the contacts into the sides of the contact carrier  
(1). Observe the contact chamber marking. First equip  
the inside part (1a) with contacts and push it into the  
outer contact carrier (1b) (observe the marking for  
assistance).  
Turn the ring of the insulating body sleeve (2) to the  
“open” position. Push the unit (1a+1b) into the  
insulating body sleeve (2). Lock (2) by turning the ring  
in the direction of “close”. When locked correctly, the  
coding grooves form a line and the contact carrier  
(1+2) cannot be separated.  
• Snap the contact carrier (unit 1+2) into the housing  
(3).  
• For dismantling, the contact carrier can be released  
from the front (plug-in side). Use the release tool  
RF-Z0001 for this.  
Assembly drawings show assembly with  
male contacts. The same applies to female  
contacts.  
PHOENIX CONTACT  
17  
Signal Connectors – PLUSCON circular  
M23 – RF Series  
Panel mounting connectors straight,  
central fastening thread  
3
RF-..P..8A6100  
RF-..S..8A6100  
2
2
4
Order counter nut M20 x 1.5  
separately (RC-13041)  
1
1b  
1b  
1a  
close  
1a  
Pos. 1 and 2: contact carrier open;  
clip the crimp contacts in at the side.  
(Recommendation for  
fitting in steel plate)  
Mounting hole with anti-rotation  
protection and counter nut  
(Recommendation for  
fitting in steel plate)  
Mounting bushing with thread  
• Secure flange connector housing (3) to the mounting  
panel with counter nut (4) or screw it directly into the  
housing panel (see assembly drawings).  
• Crimp the conductors to the contacts. Stripping lengths  
depend on the contact used; see setting matrix under  
crimping tools.  
• Clip the contacts into the sides of the contact carrier  
(1). Observe the contact chamber marking. First equip  
the inside part (1a) with contacts and push it into the  
outer contact carrier (1b) (observe the marking for  
assistance).  
Turn the ring of the insulating body sleeve (2) to the  
“open” position. Push the unit (1a+1b) into the  
insulating body sleeve (2). Lock (2) by turning the ring  
in the direction of “close”. When locked correctly, the  
coding grooves form a line and the contact carrier  
(1+2) cannot be separated.  
• Snap the contact carrier (unit 1+2) into the housing (3).  
• For dismantling, the contact carrier can be released  
from the front (plug-in side). Use the release tool  
RF-Z0001 for this.  
Assembly drawings show assembly with  
male contacts. The same applies to female  
contacts.  
PHOENIX CONTACT  
18  
Signal Connectors – PLUSCON circular  
M23 – RF Series  
Panel mounting connectors,  
angled fixed / angled rotary  
RF-.....8AAF00  
RF-.....8AAK00  
RF-.....8AAD00  
Rotary housings: Before  
mounting on the device, check  
the position of the stop edge for  
the range of rotation.  
6
RF-.....8AAC00  
4
3
2
3b  
5
3a  
1
Installation dimensions  
RF-.....8AAK00  
4
3b  
close  
3a  
Installation dimensions  
RF-.....8AAF00  
Pos. 3 and 4: contact carrier open; clip  
the crimp contacts in at the side.  
Edge stripping  
max. 0.2  
Installation dimensions  
RF-.....8AAC00  
Torx T10 • 1.7 Nm  
Edge stripping  
max. 0.2  
Installation dimensions  
RF-.....8AAD00  
• Crimp the contacts to the conductors. Stripping lengths  
depend on the contact used; see setting matrix under  
crimping tools.  
Assembly drawings show assembly with  
male contacts. The same applies to female  
contacts.  
• Clip the contacts into the sides of the contact carrier  
(3). Observe the contact chamber marking. First equip  
the inside part (3a) with contacts and push it into the  
outer contact carrier (3b) (observe the marking for  
assistance).  
• Push the assembled contact carrier (unit 3a+3b)  
through the base housing (1). Fasten the base housing  
to the device using 4 screws.  
“open” position. Push the unit (3a+3b) into the  
insulating body sleeve (4). Lock (4) by turning the ring • Position the housing cover (5) on the base housing (1)  
in the direction of “close”. When locked correctly, the  
coding grooves form a line and the insulating body  
(3+4) cannot be separated.  
• Insert the insulating body cap (2) into the base  
housing (1) from above.  
(unit 3+4), use the guide in the cover.  
and fasten with screws (6) (Torx T10), torque: 1.7 Nm.  
Turn the ring of the insulating body sleeve (4) to the  
• Push the housing cover (5) onto the insulating body  
PHOENIX CONTACT  
19  
Signal Connectors – PLUSCON circular  
M23 – RF Series  
5
Panel mounting connectors,  
angled fixed, 2-part housing  
6
4
RF-..P..8AA200  
RF-..S..8AA200  
3
3b  
3a  
4
2
1
3b  
close  
3a  
Pos. 3 and 4: contact carrier open;  
clip the crimp contacts in at the side.  
Installation dimensions  
• Crimp the conductors to the contacts. Stripping lengths  
depend on the contact used; see setting matrix under  
crimping tools. Guide the conductors through the  
assembled angle housing (1) and support (2).  
Note: The conductors can also be guided through the  
noticed ring (2) at a later time.  
• Clip the contacts into the sides of the contact carrier  
(3). Observe the contact chamber marking. First equip  
the inside part (3a) with contacts and push it into the  
outer contact carrier (3b) (observe the marking for  
assistance).  
Turn the ring of the insulating body sleeve (4) to the  
“open” position. Push the unit (3a+3b) into the  
insulating body sleeve (4). Lock (4) by turning the ring  
in the direction of “close”. When locked correctly, the  
coding grooves form a line and the contact carrier  
(3+4) cannot be separated.  
• Slide the housing (5) onto the unit (3+4).  
• Insert the ring (2) in the housing (5).  
• Fasten the assembled connector to the angle housing  
(1) using screws (6).  
Assembly drawings show assembly with  
male contacts. The same applies to female  
contacts.  
PHOENIX CONTACT  
20  
PHOENIX CONTACT  
21  
Signal Connectors – PLUSCON circular  
M27 – HC Series  
Cable connectors and cable connecting receptacles,  
straight, shielded  
Coding groove  
• Push endbell (pos.1), seal element (pos.3) with sealing • Solder, screw or crimp wires to contacts of the insert.  
ring inside (pos.2) on to the cable.  
• Fold collapsible plastic sleeve over wires as shown  
• Strip the cable exterior insulation back 30 mm  
(approx. 1.2 inches).  
(pos.4).  
• Push insert (pos.5), collapsible sleeve (pos.4), and  
sealing element (pos.3) with sealing ring (pos.2) into  
enclosure cylinder (pos.6). Caution: The desired  
coding channel of the insert (pos.5) must be aligned  
to the coding rib of the enclosure cylinder. Screw the  
endbell (pos.1) all the way down tight to the stop.  
• Bend shielding braid back at right angles and cut it as  
shown (diameter 30 mm).  
• Remove foil, inner insulation, etc. to expose cable  
wires.  
• Strip wire ends 3.5 mm, twist strands together and  
tin them with solder (if necessary).  
Panel mounting connectors,  
straight  
Remove contact carrier  
• Easy to disassemble from plug-in side without  
special tools  
PHOENIX CONTACT  
22  
Signal Connectors – PLUSCON circular  
M27 – HC Series  
PC Board layout 26-/28-pos. (dip solder contacts)  
Deviation from center ꢀ.ꢁ mm  
X
Y
X
Y
Pos.  
Pos.  
Pos.  
Pos.  
Pos.  
Pos.  
Pos.  
Pos.  
Pos.  
Pos. ꢁꢀ  
Pos. ꢁꢁ  
Pos. ꢁ2  
Pos. ꢁ3  
Pos. ꢁ4  
2
3
4
5
6
7
8
9
+1.95  
+4.85  
+6.82  
+7.72  
+7.28  
+5.67  
+3.08  
+0.55  
-3.08  
-5.67  
-7.28  
-7.75  
-6.82  
-4.82  
+7.47  
+6.05  
+3.65  
+0.65  
- 2.53  
- 5.23  
- 7.08  
- 7.73  
- 7.08  
- 5.27  
- 2.53  
+0.63  
+3.65  
+6.05  
Pos. ꢁ5  
Pos. ꢁ6  
Pos. ꢁ7  
Pos. ꢁ8  
Pos. ꢁ9  
Pos. 2ꢀ  
Pos. 2ꢁ  
Pos. 22  
Pos. 23  
Pos. 24  
Pos. 25  
Pos. 26  
Pos. 27  
Pos. 28  
-1.95  
-0.82  
+2.82  
+4.55  
+4.28  
+1.83  
-1.83  
-4.25  
-4.55  
-2.82  
-0.82  
-0.82  
+2.02  
-2.02  
+7.47  
+5.03  
+3.64  
+0.97  
- 2.13  
- 4.17  
- 4.17  
- 2.13  
+0.97  
+3.65  
+1.88  
- 1.63  
+0.14  
+0.14  
Housing Type Free solder pin length [mm]  
Dip solder  
A
B
C
pin-Ø 0.6 mm  
1.0 mm 0.8 mm  
HC-.......2300  
3.5  
4.5  
10.0  
10.0  
10.0  
HC-.......WA00  
HC-.......4300  
3.5  
4.5  
The free solder pin length A, B or C is the distance  
between the mounting flange of the panel mounting  
connector and the end of the dip solder contact. This  
distance includes the housing wall thickness and the air  
gap to the printed circuit board.  
PHOENIX CONTACT  
23  
Signal / Power Connectors – PLUSCON circular  
M17 – ST Series / P20 Series  
Cable connectors  
(Assembly for cable-Ø up to 10 mm)  
ST-..S1N8A80.., ST-..S1N8A80..S  
ST-..P1N8A80.., ST-..P1N8A80..S  
4
3
6
5
17-pos.  
without PE  
2
1
Clip the crimp contacts  
into the contact carrier (4)  
on the side.  
19  
Assembly drawings show the cable  
connector with female components.  
The same applies for male components.  
19  
• Push the adapter (1) and compression element (2)  
(sealing ring and clamping cage) over the cable.  
• Strip the external cable sheath:  
the braided screen until the protruding residual length  
of the braided screen is 12 – 18 mm.  
• Push the compression element (2) over the braided  
screen against the spacer sleeve (3) until it engages.  
Push the braided screen over the unit (2 + 3).  
The braided screen must not lie over the gasket.  
unit (2 +3) in the insulating sleeve (5).  
• Push the unit (2+3+4+5 ) into the housing (6).  
• Screw in the adapter (1), torque  
2.5 Nm for cable Ø < 5 mm  
25 mm.  
Trim and remove the foil, wadding and inner insulation.  
• Unbraid the braided screen and push it up.  
4 Nm for cable Ø 5 mm.  
• Strip the conductors (for the length, please refer to the • Clip the contacts into the sides of the contact carrier  
setting matrix for crimp contacts).  
• Crimp the conductors to the contacts.  
• Push the spacer sleeve (3) over the conductors and  
(4).  
• Push the contact carrier (4) with the assembled  
contacts into the insulating sleeve (5) and engage the  
PHOENIX CONTACT  
24  
Signal / Power Connectors – PLUSCON circular  
M17 – ST Series / P20 Series  
Cable connectors  
(Assembly for cable-Ø > 10 mm up to 11.5 mm)  
ST-..S1N8A8004, ST-..S1N8A8004S  
ST-..P1N8A8004, ST-..P1N8A8004S  
4
3
6
5
17-pos.  
without PE  
2
1
Clip the crimp contacts  
into the contact carrier (4)  
on the side.  
Assembly drawings show the cable  
connector with female components.  
The same applies for male components.  
19  
19  
• Slide adapter (1) and compression element (2) (gasket  
and clamping cage) over the cable.  
• Strip the external cable sheath:  
25 – 30 mm  
screen against the spacer sleeve (3) until it clicks into  
place. Push braided screen back over unit (2+3).  
• Clip the contacts into the sides of the contact carrier  
(4).  
The braided screen must then not lie over the gasket.  
• Slide the unit (2+3+4+5) into the housing (6).  
• Screw the adapter (1) on tight.  
Trim and remove the foil, wadding and inner insulation.  
• Unbraid the braided screen and push it up.  
• Strip the conductors (for length, refer to the setting  
matrix for crimp contacts).  
Tightening torque 4 Nm  
• Slide the contact carrier (4) with assembled contacts  
into the insulating sleeve (5) and snap the unit (2+3)  
into the insulating sleeve (5).  
• Crimp the conductors to the contacts.  
• Push the spacer sleeve (3) over the conductors up to  
the cable sheath.  
Trim braided screen to a length of 3 – 6 mm.  
• Push the compression element (2) over the braided  
PHOENIX CONTACT  
25  
Signal / Power Connectors – PLUSCON circular  
M17 – ST Series / P20 Series  
Cable connecting receptacles  
(Assembly for cable-Ø up to 10 mm)  
4
ST-..S1N8A90..S  
ST-..P1N8A90..S  
3
6
5
17-pos.  
without PE  
2
1
Clip the crimp contacts  
into the contact carrier (4)  
on the side.  
Assembly drawings show the cable  
connecting receptacle with male  
components. The same applies for  
female components.  
19  
19  
• Push the adapter (1) and compression element (2)  
(sealing ring and clamping cage) over the cable.  
• Strip the external cable sheath:  
the braided screen until the protruding residual length  
of the braided screen is 12 – 18 mm.  
• Push the compression element (2) over the braided  
screen against the spacer sleeve (3) until it engages.  
Push the braided screen over the unit (2 + 3).  
The braided screen must not lie over the gasket.  
unit (2 +3) in the insulating sleeve (5).  
• Push the unit (2+3+4+5 ) into the housing (6).  
• Screw in the adapter (1), torque  
2.5 Nm for cable Ø < 5 mm  
25 mm.  
Trim and remove the foil, wadding and inner insulation.  
• Unbraid the braided screen and push it up.  
4 Nm for cable Ø 5 mm.  
• Strip the conductors (for the length, please refer to the • Clip the contacts into the sides of the contact carrier  
setting matrix for crimp contacts).  
• Crimp the conductors to the contacts.  
• Push the spacer sleeve (3) over the conductors and  
(4).  
• Push the contact carrier (4) with the assembled  
contacts into the insulating sleeve (5) and engage the  
PHOENIX CONTACT  
26  
Signal / Power Connectors – PLUSCON circular  
M17 – ST Series / P20 Series  
Cable connecting receptacles  
(Assembly for cable-Ø > 10 mm up to 11.5 mm)  
ST-..S1N8A9004S  
ST-..P1N8A9004S  
4
3
6
5
17-pos.  
without PE  
2
1
Clip the crimp contacts  
into the contact carrier (4)  
on the side.  
Assembly drawings show the cable  
connecting receptacle with male  
components. The same applies for  
female components.  
19  
19  
• Slide adapter (1) and compression element (2) (gasket  
and clamping cage) over the cable.  
• Strip the external cable sheath:  
25 – 30 mm  
screen against the spacer sleeve (3) until it clicks into  
place. Push braided screen back over unit (2+3).  
• Clip the contacts into the sides of the contact carrier  
(4).  
The braided screen must then not lie over the gasket.  
• Slide the unit (2+3+4+5) into the housing (6).  
• Screw the adapter (1) on tight.  
Trim and remove the foil, wadding and inner insulation.  
• Unbraid the braided screen and push it up.  
• Strip the conductors (for length, refer to the setting  
matrix for crimp contacts).  
Tightening torque 4 Nm  
• Slide the contact carrier (4) with assembled contacts  
into the insulating sleeve (5) and snap the unit (2+3)  
into the insulating sleeve (5).  
• Crimp the conductors to the contacts.  
• Push the spacer sleeve (3) over the conductors up to  
the cable sheath.  
Trim braided screen to a length of 3 – 6 mm.  
• Push the compression element (2) over the braided  
PHOENIX CONTACT  
27  
Signal / Power Connectors – PLUSCON circular  
M17 – ST Series / P20 Series  
Panel mounting connectors,  
angled rotary  
6
ST-..S1N8AAD00S, ST-..P1N8AAD00S  
ST-..S1N8AAC00S, ST-..P1N8AAC00S  
17-pos.  
without PE  
Rotary housing: Before mounting  
on the device, check the position of  
the stop edge for the range of  
rotation.  
5
2
4
1
3
Clip the crimp contacts  
into the contact carrier (3)  
on the side.  
Installation dimensions  
ST-...1N8AAD00S  
Installation dimensions  
ST-...1N8AAC00S  
• Crimp the conductors to the contacts and push them  
through the fastened housing (1).  
• Clip the contacts into the contact carrier (3) on the  
side.  
• Slide the contact carrier (3) with the assembled  
contacts into the insulating sleeve (4).  
Torx T10 • 1.7 Nm  
• Engage the ejection protection (2) onto the unit (3+4).  
• Push the cover (5) onto the unit (2+3+4) horizontally.  
• Position the cover (5) to the housing (1) vertically and  
fasten it with screws (6) (Torx T10), torque: 1.7 Nm.  
Assembly drawings show the panel  
mounting connector with male components.  
The same applies for female components.  
PHOENIX CONTACT  
28  
Signal / Power Connectors – PLUSCON circular  
M17 – ST Series / P20 Series  
Panel mounting connectors,  
straight  
4
ST-..S1N8AWQ00S  
ST-..P1N8AWQ00S  
5
M2.5 (not included in  
the scope of delivery)  
3
2
1
17-pos.  
without PE  
Clip the crimp contacts  
into the contact carrier (2)  
on the side.  
Installation dimensions  
• Crimp the conductors to the contacts and push them  
through the support (1).  
• Clip the contacts into the contact carrier (2) on the  
side.  
• Slide the contact carrier (2) with the assembled  
contacts into the insulating sleeve (3).  
• Guide the unit (2) and (3) into the housing (4).  
• Set the support (1) on the housing (4).  
• Secure flange connector unit to the mounting panel  
using screws (5).  
Assembly drawings show the panel  
mounting connector with male components.  
The same applies for female components.  
PHOENIX CONTACT  
29  
Signal / Power Connectors – PLUSCON circular  
M17 – ST Series / P20 Series  
Panel mounting connectors straight  
with contact insert for snapping  
4
ST-..S1N8AW400S  
3
ST-..P1N8AW400S  
5
M2.5 (not included in  
the scope of delivery)  
2
1
17-pos.  
without PE  
Clip the crimp contacts  
into the contact carrier (2)  
on the side.  
Installation dimensions  
• Secure flange connector housing (4) to the mounting  
panel using screws (5).  
• Crimp the conductors to the contacts and push them  
through the support (1). (Support can also be attached  
later.)  
• Clip the contacts into the contact carrier (2) on the  
side.  
• Slide the contact carrier (2) with the assembled  
contacts into the insulating sleeve (3).  
• Snap the support (1) onto the unit (2+3).  
• Snap the unit (1+2+3) into the housing (4).  
• For dismantling, the support can be released from the  
front (plug-in side). Use the release tool ST-Z0001 for  
this.  
Assembly drawings show the panel  
mounting connector with male components.  
The same applies for female components.  
PHOENIX CONTACT  
30  
Signal / Power Connectors – PLUSCON circular  
M17 – ST Series / P20 Series  
Panel mounting connectors straight,  
central fastening thread,  
front mounting  
19  
20  
ST-..S1N8A6100S  
ST-..P1N8A6100S  
3
4
5
Order counter nut M18 x 0.75  
separately (ST-E2015151)  
2
1
17-pos.  
without PE  
Clip the crimp contacts  
into the contact carrier (2)  
on the side.  
(Recommendation for  
fitting in steel plate)  
Mounting hole with anti-rotation  
protection and counter nut  
(Recommendation for  
fitting in steel plate)  
Mounting bushing with thread  
• Secure flange connector housing (4) to the mounting  
panel with counter nut (5) or screw it directly into the  
housing panel (see assembly drawings).  
• Crimp the conductors to the contacts and push them  
through the support (1). (Support can also be attached  
later.)  
• Clip the contacts into the contact carrier (2) on the  
side.  
• Slide the contact carrier (2) with the assembled  
contacts into the insulating sleeve (3).  
• Snap the support (1) onto the unit (2+3).  
• Snap the unit (1+2+3) into the housing (4).  
• For dismantling, the support can be released from the  
front (plug-in side). Use the release tool ST-Z0001 for  
this.  
Assembly drawings show the panel  
mounting connector with male components.  
The same applies for female components.  
PHOENIX CONTACT  
31  
Signal / Power Connectors – PLUSCON circular  
M17 – ST Series / P20 Series  
Panel mounting connectors straight,  
central fastening thread,  
rear mounting  
24  
24  
4
3
ST-..S1N8AH100S  
ST-..P1N8AH100S  
5
Order counter nut M20 x 1.5  
separately (RC-13041)  
2
1
17-pos.  
without PE  
Clip the crimp contacts  
into the contact carrier (2)  
on the side.  
(Recommendation for  
fitting in steel plate)  
Mounting hole with anti-rotation  
protection and counter nut  
(Recommendation for  
fitting in steel plate)  
Mounting bushing with thread  
• Secure flange connector housing (4) to the mounting  
panel with counter nut (5) or screw it directly into the  
housing panel (see assembly drawings).  
• Crimp the conductors to the contacts and push them  
through the support (1). (Support can also be attached  
later.)  
• Clip the contacts into the contact carrier (2) on the  
side.  
• Slide the contact carrier (2) with the assembled  
contacts into the insulating sleeve (3).  
• Snap the support (1) onto the unit (2+3).  
• Snap the unit (1+2+3) into the housing (4).  
• For dismantling, the support can be released from the  
front (plug-in side). Use the release tool ST-Z0001 for  
this.  
Assembly drawings show the panel  
mounting connector with male components.  
The same applies for female components.  
PHOENIX CONTACT  
32  
PHOENIX CONTACT  
33  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Cable connectors,  
short version  
SF-5ES1N8A80..  
SF-7ES1N8A80..  
6
3
2
5
1
4
Clip the crimp contacts into  
the contact carrier (5) on  
the side.  
26  
26  
• Push the adapter (1) and the sealing element (3) with • Crimp the conductors to the contacts (with or without  
• Cut the shielding to length if necessary and twist the  
remaining shielding into the space provided (3).  
the sealing ring (2) onto the cable.  
• Strip the external cable sheath:  
Short version (64 mm long):  
insulating crimp).  
Clip the contacts into the sides of the contact carrier (5). • Screw the adapter (1) as tight as possible.  
• Open the spacer sleeve (4), fit it before the braided  
screen and clip them together.  
• Guide the contact carrier (5) and the spacer sleeve (4)  
into the insert sleeve (6).  
• Push up the braided screen and slide the sealing  
element (3) with the braided screen firmly against the  
spacer sleeve (4) until the teeth lock.  
6-position:  
8-position:  
29 mm  
32 mm for contacts Ø 1 mm,  
for contacts Ø 2 mm, cut the conductors  
to a length of 28 mm.  
Trim and remove the foil, wadding and inner insulation.  
• Unbraid the braided screen and push it back.  
• Strip the conductors (for the length, please refer to the  
setting matrix for crimp contacts).  
The braided screen then lies between the insert sleeve  
(6) and the sealing element (3).  
PHOENIX CONTACT  
34  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Cable connectors,  
long version  
SF-5ES1N8A8L..  
SF-7ES1N8A8L..  
6
5
3
2
1
4
Clip the crimp contacts into  
the contact carrier (5) on  
the side.  
26  
26  
• Push the adapter (1) and the sealing element (3) with • Crimp the conductors to the contacts (with or without  
• Cut the shielding to length if necessary and twist the  
remaining shielding into the space provided (3).  
the sealing ring (2) onto the cable.  
• Strip the external cable sheath:  
long version (75 mm long):  
insulating crimp).  
• Clip the contacts into the sides of the contact carrier (5). • Screw the adapter (1) as tight as possible.  
• Open the spacer sleeve (4), fit it before the braided  
screen and clip them together.  
6-position: 37 mm  
8-position: 40 mm for contacts Ø 1 mm,  
• Guide the contact carrier (5) and the spacer sleeve (4)  
into the insert sleeve (6).  
for contacts Ø 2 mm, cut the conductors  
to a length of 36 mm.  
• Push up the braided screen and slide the sealing  
element (3) with the braided screen firmly against the  
spacer sleeve (4) until the teeth lock.  
The braided screen then lies between the insert sleeve  
(6) and the sealing element (3).  
Trim and remove the foil, wadding and inner insulation.  
• Unbraid the braided screen and push it back.  
• Strip the conductors (for the length, please refer to the  
setting matrix for crimp contacts).  
PHOENIX CONTACT  
35  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Cable connecting receptacles,  
short version  
SF-5EP1N8A90..  
SF-7EP1N8A90..  
6
7
3
2
5
1
4
Clip the crimp contacts into  
the contact carrier (5) on  
the side.  
26  
26  
• Push the adapter (1) and the sealing element (3) with • Crimp the conductors to the contacts (with or without  
(6) and the sealing element (3).  
the sealing ring (2) onto the cable.  
• Strip the external cable sheath:  
Short version (60.1 mm long):  
insulating crimp).  
• Cut the shielding to length if necessary and twist the  
remaining shielding into the space provided (3).  
• Screw the adapter (1) as tight as possible.  
• Clip the contacts into the sides of the contact carrier (5).  
• Open the spacer sleeve (4), fit it before the braided  
screen and clip them together.  
6-position:  
8-position:  
25 mm  
29 mm for contacts Ø 1 mm,  
• Slide the contact carrier sleeve (7) onto contact carrier (5).  
for contacts Ø 2 mm, cut the conductors • Guide the unit (5+7) into the insert sleeve (6).  
to a length of 24 mm. • Guide the spacer sleeve (4) into the insert sleeve (6).  
Trim and remove the foil, wadding and inner insulation. • Push up the braided screen and slide the sealing  
• Unbraid the braided screen and push it back.  
• Strip the conductors (for the length, please refer to the  
setting matrix for crimp contacts).  
element (3) with the braided screen firmly against the  
spacer sleeve (4) until the teeth lock.  
The braided screen then lies between the insert sleeve  
PHOENIX CONTACT  
36  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Cable connecting receptacles,  
long version  
SF-5EP1N8A9L..  
SF-7EP1N8A9L..  
6
7
3
5
2
1
4
Clip the crimp contacts into  
the contact carrier (5) on  
the side.  
26  
• Push the adapter (1) and the sealing element (3) with  
the sealing ring (2) onto the cable.  
• Strip the external cable sheath:  
26  
long version (70.9 mm long):  
6-position:  
8-position:  
33 mm  
• Open the spacer sleeve (4), fit it before the braided  
screen and clip them together.  
• Slide the contact carrier sleeve (7) onto contact carrier (5). • Screw the adapter (1) as tight as possible.  
• Guide the unit (5+7) into the insert sleeve (6).  
• Guide the spacer sleeve (4) into the insert sleeve (6).  
• Push up the braided screen and slide the sealing  
element (3) with the braided screen firmly against the  
spacer sleeve (4) until the teeth lock.  
The braided screen then lies between the insert sleeve  
(6) and the sealing element (3).  
• Cut the shielding to length if necessary and twist the  
remaining shielding into the space provided (3).  
37 mm for contacts Ø 1 mm,  
for contacts Ø 2 mm, cut the conductors  
to a length of 32 mm.  
Trim and remove the foil, wadding and inner insulation.  
• Unbraid the braided screen and push it back.  
• Strip the conductors (for the length, please refer to the  
setting matrix for crimp contacts).  
• Crimp the conductors to the contacts (with or without  
insulating crimp).  
• Clip the contacts into the sides of the contact carrier (5).  
PHOENIX CONTACT  
37  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Cable connectors with metric thread  
for external cable gland M20 x 1.5  
SF-5ES1N8AR4DU  
SF-7ES1N8AR4DU  
6
5
3
2
1
4
M20 x 1.5  
Clip the crimp contacts into  
the contact carrier (5) on  
the side.  
26  
26  
• Push the adapter (1) and the sealing element (3) with • Crimp the conductors to the contacts (with or without  
remaining shielding into the space provided (3).  
• Screw the adapter (1) as tight as possible.  
the sealing ring (2) onto the cable.  
• Strip the external cable sheath:  
insulating crimp).  
• Clip the contacts into the sides of the contact carrier (5).  
• Open the spacer sleeve (4), fit it before the braided  
screen and clip them together.  
• Guide the contact carrier (5) and the spacer sleeve (4)  
into the insert sleeve (6).  
• Push up the braided screen and slide the sealing  
element (3) with the braided screen firmly against the  
spacer sleeve (4) until the teeth lock.  
6-position:  
8-position:  
29 mm  
32 mm for contacts Ø 1 mm,  
for contacts Ø 2 mm, cut the conductors  
to a length of 28 mm..  
Trim and remove the foil, wadding and inner insulation.  
• Unbraid the braided screen and push it back.  
• Strip the conductors (for the length, please refer to the  
setting matrix for crimp contacts).  
The braided screen then lies between the insert sleeve  
(6) and the sealing element (3).  
• Cut the shielding to length if necessary and twist the  
PHOENIX CONTACT  
38  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Cable connecting receptacles with metric thread  
for external cable gland M20 x 1.5  
SF-5EP1N8AF4DU  
SF-7EP1N8AF4DU  
6
7
3
2
5
1
4
Clip the crimp contacts into  
the contact carrier (5) on the  
side.  
M20 x 1.5  
26  
• Push the adapter (1) and the sealing element (3) with  
the sealing ring (2) onto the cable.  
• Strip the external cable sheath:  
26  
6-position:  
8-position:  
25 mm  
29 mm for contacts Ø 1 mm,  
for contacts Ø 2 mm, cut the conductors  
to a length of 24 mm.  
• Slide the contact carrier sleeve (7) onto contact carrier (5).  
• Guide the unit (5+7) into the insert sleeve (6).  
• Guide the spacer sleeve (4) into the insert sleeve (6).  
• Push up the braided screen and slide the sealing  
element (3) with the braided screen firmly against the  
spacer sleeve (4) until the teeth lock.  
The braided screen then lies between the insert sleeve  
(6) and the sealing element (3).  
• Cut the shielding to length if necessary and twist the  
remaining shielding into the space provided (3).  
• Screw the adapter (1) as tight as possible.  
Trim and remove the foil, wadding and inner insulation.  
• Unbraid the braided screen and push it back.  
• Strip the conductors (for the length, please refer to the  
setting matrix for crimp contacts).  
• Crimp the conductors to the contacts (with or without  
insulating crimp).  
• Clip the contacts into the sides of the contact carrier (5).  
• Open the spacer sleeve (4), fit it before the braided  
screen and clip them together.  
PHOENIX CONTACT  
39  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Wall bushings with mounting flange,  
short version  
SF-5EP1N8AC0..  
SF-7EP1N8AC0..  
6
7
3
2
5
1
4
Clip the crimp contacts into  
the contact carrier (5) on  
the side.  
Installation dimensions  
• Push the adapter (1) and the sealing element (3) with  
the sealing ring (2) onto the cable.  
• Strip the external cable sheath:  
26  
Short version (60.1 mm long):  
• Crimp the conductors to the contacts (with or without  
insulating crimp).  
• Clip the contacts into the sides of the contact carrier (5).  
• Open the spacer sleeve (4), fit it before the braided  
screen and clip them together.  
• Slide the contact carrier sleeve (7) onto contact carrier (5).  
• Guide the unit (5+7) into the insert sleeve (6).  
• Guide the spacer sleeve (4) into the insert sleeve (6).  
• Push up the braided screen and slide the sealing  
element (3) with the braided screen firmly against the  
spacer sleeve (4) until the teeth lock.  
The braided screen then lies between the insert sleeve  
(6) and the sealing element (3).  
• Cut the shielding to length if necessary and twist the  
remaining shielding into the space provided (3).  
• Screw the adapter (1) as tight as possible.  
6-position:  
8-position:  
25 mm  
29 mm for contacts Ø 1 mm,  
for contacts Ø 2 mm, cut the conductors  
to a length of 24 mm.  
Trim and remove the foil, wadding and inner insulation.  
• Unbraid the braided screen and push it back.  
• Strip the conductors (for the length, please refer to the  
setting matrix for crimp contacts).  
PHOENIX CONTACT  
40  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Wall bushings with mounting flange,  
long version  
SF-5EP1N8ACL..  
SF-7EP1N8ACL..  
6
7
3
5
2
1
4
Clip the crimp contacts into  
the contact carrier (5) on the  
side.  
Installation dimensions  
• Push the adapter (1) and the sealing element (3) with  
the sealing ring (2) onto the cable.  
• Strip the external cable sheath:  
long version (70.9 mm long):  
26  
6-position: 33 mm  
8-position: 37 mm for contacts Ø 1 mm,  
for contacts Ø 2 mm, cut the conductors to  
• Clip the contacts into the sides of the contact carrier (5).  
• Open the spacer sleeve (4), fit it before the braided  
screen and clip them together.  
• Slide the contact carrier sleeve (7) onto contact carrier (5).  
• Guide the unit (5+7) into the insert sleeve (6).  
• Guide the spacer sleeve (4) into the insert sleeve (6).  
• Push up the braided screen and slide the sealing  
element (3) with the braided screen firmly against the  
spacer sleeve (4) until the teeth lock.  
The braided screen then lies between the insert sleeve  
(6) and the sealing element (3).  
• Cut the shielding to length if necessary and twist the  
remaining shielding into the space provided (3).  
• Screw the adapter (1) as tight as possible.  
a length of 32 mm.  
Trim and remove the foil, wadding and inner insulation.  
• Unbraid the braided screen and push it back.  
• Strip the conductors (for the length, please refer to the  
setting matrix for crimp contacts).  
• Crimp the conductors to the contacts (with or without  
insulating crimp).  
PHOENIX CONTACT  
41  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Panel mounting connectors straight  
5
4
M3 (not included in  
the scope of delivery)  
SF-5EP1N8AWA00  
SF-7EP1N8AWA00  
3
1
2
Clip the crimp contacts into  
the contact carrier (2) on  
the side.  
Installation dimensions  
• Crimp the conductors to the contacts and guide them  
through the mounting panel and the ring (1).  
• Clip the contacts into the contact carrier (2) on the  
side.  
• Push the sleeve (3) onto the contact carrier (2).  
• Slide the housing (4) onto the unit (2+3).  
• Insert the support (1) in the housing (4).  
• Fasten the assembled connectors to the mounting  
panel (5) using screws.  
PHOENIX CONTACT  
42  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Panel mounting connectors straight,  
flat design  
4
5
M3 (not included in  
the scope of delivery)  
SF-5EP1N8AWK00  
SF-7EP1N8AWK00  
3
1
2
Clip the crimp contacts into  
the contact carrier (2) on  
the side.  
Installation dimensions  
• Crimp the conductors to the contacts and guide them  
through the mounting panel and the ring (1).  
• Clip the contacts into the contact carrier (2) on the  
side.  
• Push the sleeve (3) onto the contact carrier (2).  
• Slide the housing (4) onto the unit (2+3).  
• Insert the ring (1) in the housing (4).  
• Fasten the assembled connectors to the mounting  
panel (5) using screws.  
PHOENIX CONTACT  
43  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Panel mounting connectors,  
angled fixed / angled rotary  
SF-.EP1N8AAF00  
SF-.EP1N8AAK00  
SF-.EP1N8AAD00  
SF-.EP1N8AAC00  
Rotary housings: Before mounting  
on the device, check the position of  
the stop edge for the range of  
rotation.  
5
4
1
3
Installation dimensions  
SF-.EP1N8AAF00  
2
Clip the crimp contacts  
into the contact carrier  
(2) on the side.  
Installation dimensions  
SF-.EP1N8AAK00  
Edge stripping  
max. 0.2  
Installation dimensions  
SF-.EP1N8AAD00  
Torx T10 • 1.7 Nm  
Edge stripping  
max. 0.2  
Installation dimensions  
SF-.EP1N8AAC00  
• Crimp the conductors to the contacts and push them  
through the housing (1).  
• Fasten base housing pos. 1 using 4 screws.  
• Clip the contacts into the sides of the contact carrier (2).  
• Push the sleeve (3) onto the contact carrier (2).  
• Push the cover (4) onto the unit (2+3), use guide in  
cover.  
• Position the cover (4) to the housing (1) and fasten with  
screws (5) (Torx T10), torque: 1.7 Nm.  
PHOENIX CONTACT  
44  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Panel mounting connectors,  
angled fixed, 2-part housing  
6
SF-5EP1N8AA200  
SF-7EP1N8AA200  
5
4
1
3
2
Clip the crimp contacts into  
the contact carrier (3) on the  
side.  
Installation dimensions  
• Crimp the conductors to the contacts and push them  
through the assembled angle housing (1) and support  
(2).  
• Clip the contacts into the contact carrier (3) on the  
side.  
• Push the sleeve (4) onto the contact carrier (3).  
• Slide the housing (5) onto the unit (3+4).  
• Insert the support pos. 2 in the housing pos. 5.  
• Fasten the assembled connectors to the angle housing  
(6) using screws.  
PHOENIX CONTACT  
45  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Panel mounting connectors with knurled nut  
4
M3 (not included in  
the scope of delivery)  
SF-5ES1N8AY000  
SF-7ES1N8AY000  
3
1
2
Panel mounting connectors with  
knurled nut must have female  
contacts. Clip the crimp contacts  
into the contact carrier (2) on the  
side.  
Installation dimensions  
• Guide the conductors through the mounting panel and  
crimp them to the contacts.  
• Slide the crimped contacts through the bracket (1).  
• Clip the contacts into the contact carrier (2) on the  
side.  
• Slide the contact carrier (2) with preassembled  
contacts into the housing (3).  
• Position the bracket (1) in the housing (3).  
• Fasten the complete unit to the mounting panel (4)  
using screws.  
PHOENIX CONTACT  
46  
Power Connectors – PLUSCON circular  
M23 – P30 Series  
Panel mounting connectors with knurled nut,  
angled fixed  
SF-5ES1N8AYW00  
SF-7ES1N8AYW00  
5
4
1
3
2
Panel mounting connectors with  
knurled nut must have female contacts.  
Clip the crimp contacts into the contact  
carrier (3) on the side.  
Installation dimensions  
• Crimp the conductors to the contacts and push them  
through the assembled angle housing (1) and support  
(2).  
• Clip the contacts into the contact carrier (3) on the side.  
• Slide the contact carrier (3) with preassembled contacts  
into the housing (4).  
• Insert the support pos. 2 in the housing pos. 4.  
• Fasten the assembled connectors to the angle housing  
(5) using screws.  
PHOENIX CONTACT  
47  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
Cable connectors,  
SPEEDCON / long version  
4
SM-.ES1N8A8S.. (long version)  
SM-.ES1N8A8L..S (SPEEDCON quick locking)  
5
3
2
1
Clip the crimp contacts  
into the contact carrier  
(4) on the side.  
For example pin  
assignment, see page 59  
41  
41  
• After assigning the connections, mount the contacts  
on the contact carrier (4).  
• Slide adapter (1) and compression element (2)  
(sealing ring and clamping cage) over the cable.  
• Strip the sheath of the 62 mm cable.  
• Cut off and remove foil and other filling material.  
• Unbraid the braided screen and push back approx. half  
of the length that has been stripped.  
• Push the contacting ring (3) over the conductors and  
the braided screen until the inside diameter of the level  
surface is flush with the cable sheath.  
• Push the compression element (2) onto the contacting  
ring (3). Screw the remaining shielding into the unit  
(2 + 3) by turning the compression element (2) while  
Procedure: First clip in the power contacts and PE  
contacts, then the signal contacts on the side.  
• Fit the assembled unit in the housing (5).  
Note: Use the PE connection as orientation.  
• Screw in the adapter (1) tightly, torque  
25 Nm for cable gaskets Ø 9.0-14.0 mm  
20 Nm for cable gaskets Ø 14.0-20.5 mm  
20 Nm for cable gaskets Ø 20.5-26.5 mm.  
Note: Dimensions for assembly may differ depending on  
the cable variant.  
preventing the contacting ring (3) from turning.  
• Shorten the 3 power conductors to 50 mm and the PE  
conductor to 51.5 mm.  
• Strip the wires:  
10 mm for power and PE contacts Ø 3.6 mm  
8 mm for signal contacts Ø 2 mm.  
• Crimp the conductors to the contacts. Observe  
settings for crimping pliers and positioner (please refer  
to the setting matrix for crimp contacts).  
PHOENIX CONTACT  
48  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
4
Cable connectors,  
short version  
3
SM-.ES1N8A80..  
2
1
Clip the crimp contacts into the  
side of the insulating body (3).  
For example pin assignment,  
see page 59  
41  
41  
Designation  
Stripping length, sheath Offset length  
Stripping, insulation  
Short version  
Short version  
---  
External sheath  
Control wires  
Power wires  
63.4 mm  
---  
---  
---  
---  
---  
8 mm  
10 mm  
10 mm  
Cut to 51.4 mm  
Cut to 52.9 mm  
PE conductors  
• Slide adapter (1) and compression element (2) over  
the cable.  
• Strip the sheath of the power connector (see table).  
Unbraid the braided screen of the main shield and  
push it back.  
• Remove foil and other filling material.  
• Offset individual wires and strip following the table.  
• Crimp the power and control contacts using crimping  
pliers. Observe settings for manual crimping pliers and  
positioner (please refer to the setting matrix for crimp  
contacts).  
• After assigning the connections, mount the contacts  
on the insulating body (3).  
Procedure: First clip in the power contacts and PE  
contacts, then the control contacts.  
• Fit the assembled unit in the housing (4).  
Note: Use the PE connection as orientation.  
• Fold up the braided screen.  
• Push the pressure cage assembly (2) over the crown  
of the housing (4).  
aid of two fork spanners WAF 41, screw as tight as  
possible.  
Note:  
Dimensions for the assembly may differ depending on  
the cable variant.  
Trim the shield (see cutting edge drawing above).  
• Push the adapter over the pressure cage and with the  
PHOENIX CONTACT  
49  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
Cable connecting receptacles,  
long version  
4
SM-.EP1N8A9L..S  
5
3
2
1
41  
41  
Clip the crimp contacts  
into the contact carrier  
(4) on the side.  
For example pin assignment,  
see page 59  
• Slide adapter (1) and compression  
element (2) (sealing ring and clamping cage) over the  
cable.  
• Strip the sheath of the 62 mm cable.  
• Cut off and remove foil and other filling material.  
• Unbraid the braided screen and push back approx. half  
of the length that has been stripped.  
• Push the contacting ring (3) over the conductors and  
the braided screen until the inside diameter of the level  
surface is flush with the cable sheath.  
• Push the compression element (2) onto the contacting  
ring (3). Screw the remaining shielding into the unit  
(2 + 3) by turning the compression element (2) while  
preventing the contacting ring (3) from turning.  
Procedure: First clip in the power contacts and PE  
contacts, then the signal contacts on the side.  
• Fit the assembled unit in the housing (5).  
Note: Use the PE connection as orientation.  
• Screw in the adapter (1) tightly, torque  
25 Nm for cable gaskets Ø 9.0-14.0 mm  
20 Nm for cable gaskets Ø 14.0-20.5 mm  
20 Nm for cable gaskets Ø 20.5-26.5 mm.  
Note: Dimensions for assembly may differ depending on  
the cable variant.  
• Shorten the 3 power conductors to 50 mm and the PE  
conductor to 51.5 mm.  
• Strip the wires:  
10 mm for power and PE contacts Ø 3.6 mm  
8 mm for signal contacts Ø 2 mm.  
• Crimp the conductors to the contacts. Observe  
settings for crimping pliers and positioner (please refer  
to the setting matrix for crimp contacts).  
• After assigning the connections, mount the contacts  
on the contact carrier (4).  
PHOENIX CONTACT  
50  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
4
Cable connecting receptacles,  
short version  
3
SM-.EP1N8A90..  
2
1
Clip the crimp contacts into side of  
the insulating body (3).  
For example pin assignment,  
see page 59  
41  
41  
Designation  
Stripping length, sheath Offset length  
Stripping, insulation  
Short version  
Short version  
---  
External sheath  
Control wires  
Power wires  
63.4 mm  
---  
---  
---  
---  
---  
8 mm  
10 mm  
10 mm  
Cut to 51.4 mm  
Cut to 52.9 mm  
PE conductors  
• Slide adapter (1) and compression element (2) over  
the cable.  
• Strip the sheath of the power connector (see table).  
Unbraid the braided screen of the main shield and  
push it back.  
contacts).  
Trim the shield (see cutting edge drawing above).  
• Push the adapter over the pressure cage and with the  
aid of two fork spanners WAF 41, screw as tight as  
possible.  
• After assigning the connections, mount the contacts  
on the insulating body (3).  
Procedure: First clip in the power contacts and PE  
contacts, then the control contacts.  
• Remove foil and other filling material.  
• Offset individual wires and strip following the table.  
• Crimp the power and control contacts using crimping  
• Fit the assembled unit in the housing (4).  
Note: Use the PE connection as orientation.  
• Fold up the braided screen.  
Note:  
Dimensions for the assembly may differ depending on  
the cable variant.  
pliers. Observe settings for manual crimping pliers and • Push the pressure cage assembly (2) over the crown  
positioner (please refer to the setting matrix for crimp of the housing (4).  
PHOENIX CONTACT  
51  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
4
Wall bushings  
with square mounting flange  
3
SM-.EP1N8AC0.. (short version)  
SM-.EP1N8ACL.. (long version)  
2
1
Clip the crimp contacts into side  
of the insulating body (3).  
For example pin assignment,  
see page 59  
41  
41  
Installation dimensions  
Designation  
Stripping length, sheath Offset length  
Stripping, insulation  
Short/long version  
Short/long version  
External sheath  
Control wires  
Power wires  
63.4 mm/75 mm  
---  
---  
---  
---  
---  
---  
8 mm  
10 mm  
10 mm  
Cut to 51.4 mm/63 mm  
Cut to 52.9 mm/64.5 mm  
PE conductors  
• Slide adapter (1) and compression element (2) over  
the cable.  
• Strip the sheath of the power connector (see table).  
Unbraid the braided screen of the main shield and  
push it back.  
contacts).  
Trim the shield (see cutting edge drawing above).  
• Push the adapter over the pressure cage and with the  
aid of two fork spanners WAF 41, screw as tight as  
possible.  
• After assigning the connections, mount the contacts  
on the insulating body (3).  
Procedure: First clip in the power contacts and PE  
contacts, then the control contacts.  
• Remove foil and other filling material.  
• Offset individual wires and strip following the table.  
• Crimp the power and control contacts using crimping  
• Fit the assembled unit in the housing (4).  
Note: Use the PE connection as orientation.  
• Fold up the braided screen.  
Note:  
Dimensions for the assembly may differ depending on  
the cable variant.  
pliers. Observe settings for manual crimping pliers and • Push the pressure cage assembly (2) over the crown  
positioner (please refer to the setting matrix for crimp  
of the housing (4).  
PHOENIX CONTACT  
52  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
4
Wall bushings  
with hexagonal mounting flange  
3
SM-.EP1N8AQ0.. (short version)  
SM-.EP1N8AQL.. (long version)  
2
1
41  
Clip the crimp contacts into side  
of the insulating body (3).  
For example pin assignment,  
see page 59  
41  
Installation dimensions  
Designation  
Stripping length, sheath Offset length  
Stripping, insulation  
Short/long version  
Short/long version  
External sheath  
Control wires  
Power wires  
63.4 mm/75 mm  
---  
---  
---  
---  
---  
---  
8 mm  
10 mm  
10 mm  
Cut to 51.4 mm/63 mm  
Cut to 52.9 mm/64.5 mm  
PE conductors  
• Slide adapter (1) and compression element (2) over  
the cable.  
• Strip the sheath of the power connector (see table).  
Unbraid the braided screen of the main shield and  
push it back.  
contacts).  
Trim the shield (see cutting edge drawing above).  
• Push the adapter over the pressure cage and with the  
aid of two fork spanners WAF 41, screw as tight as  
possible.  
• After assigning the connections, mount the contacts  
on the insulating body (3).  
Procedure: First clip in the power contacts and PE  
contacts, then the control contacts.  
• Remove foil and other filling material.  
• Offset individual wires and strip following the table.  
• Crimp the power and control contacts using crimping  
• Fit the assembled unit in the housing (4).  
Note: Use the PE connection as orientation.  
• Fold up the braided screen.  
Note:  
Dimensions for the assembly may differ depending on  
the cable variant.  
pliers. Observe settings for manual crimping pliers and • Push the pressure cage assembly (2) over the crown  
positioner (please refer to the setting matrix for crimp of the housing (4).  
PHOENIX CONTACT  
53  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
Panel mounting connectors,  
angled fixed  
SM-.EPWN8AA200  
6
5
4
2
1
3
Clip the crimp contacts into the  
side of the insulating body (3).  
For example pin assignment,  
see page 59  
Installation dimensions  
• Crimp the conductors to the contacts and push them  
through the assembled angle housing (1) and support  
(2).  
• Clip the contacts into the side of the lower part of the  
insulating body (3).  
Procedure: First clip in the power contacts and PE  
contacts, then the control contacts.  
• Slide the lower part of the insulating body (3) with the  
assembled contacts into the insulating sleeve (4).  
• Guide the unit (3) and (4) into the housing (5).  
• Mount the support (2) in the housing (5).  
• Screw flange connector (5) with screws (6) to the  
angle housing (1).  
PHOENIX CONTACT  
54  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
5
Panel mounting connectors,  
angled rotary  
SM-.EPWN8AAD00S  
3
Rotary housing: Before mounting  
on the device, check the position of  
the stop edge for the range of  
rotation.  
2
4
1
Clip the crimp contacts  
into the side of the  
insulating body (2).  
For example pin  
assignment,  
see page 59  
Edge stripping  
max. 0.3  
Installation dimensions  
Torx T20 • 3.2 Nm  
• Crimp the conductors to the contacts and push them through the housing (1).  
• Clip the contacts into the side of the lower part of the insulating body (2).  
Procedure: First clip in the power contacts and PE contacts, then the control  
contacts.  
• Slide the lower part of the insulating body (2) with the assembled contacts into the  
insulating sleeve (3).  
• Push the unit (2+3) from above into the housing guide (1).  
• Push the cover (4) onto the housing (1) and hook it in.  
• Attach the cover (4) with the screws (5) (Torx T20),  
torque: 3.2 Nm.  
PHOENIX CONTACT  
55  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
Panel mounting connectors,  
straight  
SM-.EPWN8AWT00  
5
4
M4 (not included in  
the scope of delivery)  
3
2
1
Clip the crimp contacts into the  
side of the insulating body (2).  
For example pin assignment,  
see page 59  
Installation dimensions  
• Crimp the conductors to the contacts and push them  
through the support (1).  
• Clip the contacts into the lower part of the insulating  
body (2).  
• Slide the lower part of the insulating body (2) with the  
assembled contacts into the insulating sleeve (3).  
• Guide the unit (2) and (3) into the housing (4).  
• Mount the support (1) in the housing (4).  
• Secure flange connector unit to the mounting panel  
using screws (5).  
PHOENIX CONTACT  
56  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
Panel mounting connectors with knurled nut,  
straight  
SM-.ES1N8AY000S (SPEEDCON quick locking)  
SM-.ES1N8AY000  
4
M4 (not included  
in the scope of  
delivery)  
3
1
2
Panel mounting connectors with knurled  
nut must have female contacts. Clip the  
crimp contacts into the side of the  
insulating body (2).  
For example pin assignment,  
see page 59  
• Crimp the conductors to the contacts and push  
them through the support (1).  
Installation dimensions  
• Clip the contacts into the insulating body (2).  
• Slide the insulating body (2) with preassembled  
contacts into the housing (3).  
• Mount the support (1) in the housing (3).  
• Secure flange connector unit to the mounting panel  
using screws (4).  
PHOENIX CONTACT  
57  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
Panel mounting connectors with knurled nut,  
angled fixed  
SM-.ES1N8AYW00S (SPEEDCON quick locking)  
SM-.ES1N8AYW00  
5
4
2
3
1
Panel mounting connectors with knurled  
nut must have female contacts. Clip the  
crimp contacts into the side of the  
insulating body (3).  
For example pin assignment,  
see page 59  
Installation dimensions  
• Crimp the conductors to the contacts and push them  
through the assembled angle housing (1) and  
support (2).  
• Clip the contacts into the insulating body (3).  
• Slide the insulating body (3) with preassembled  
contacts into the housing (4).  
• Mount the support (2) in the housing (4).  
• Screw flange connector with screws (5) to the  
assembled angle housing (1).  
PHOENIX CONTACT  
58  
Power Connectors – PLUSCON circular  
M40 – P70 Series  
Example for pin assignment  
Example  
pin assignment  
Pin Conductor  
Function  
1
4
L1  
L2  
U
V
Motor  
Motor  
3
L3  
W
Motor  
2
green/yellow  
Signal  
Signal  
Signal  
Signal  
PE  
A
B
C
D
1
2
+
Temp. Sensor -  
Temp. Sensor +  
Brake -  
Brake +  
Note:  
Pin assignment is application-specific  
PHOENIX CONTACT  
59  
Power Connectors – PLUSCON circular  
M58 – P150 Series  
Cable connectors  
5
SL-5ES1N8A80..  
SL-7ES1N8A80..  
4
6
3
2
1
Clip the crimp contacts  
into the contact carrier (4)  
on the side.  
55  
55  
• Slide adapter (1) and compression element (2)  
(sealing ringand clamping cage) over the cable.  
• Strip cable by 65 mm.  
leave the PE conductor and the signal conductors as  
they are.  
on the contact carrier (4).  
Procedure: First clip in the power contacts and PE  
contacts, then the signal contacts on the side.  
• Fit the assembled unit in the insulating sleeve (5).  
• Guide the unit (2+3+4+5 ) into the housing (6).  
Note: Use the PE connection as orientation.  
• Screw the adapter (1) tight, torque 30 Nm.  
Note:  
• Strip the wires:  
• Cut off and remove foil and other filling material.  
13.8 mm for contact cross sections of 10 mm2 and  
• Unbraid the braided screen and push back approx. half 16 mm2  
of the length that has been stripped.  
16.8 mm for a contact cross section of 25 mm2  
• Push the contacting ring (3) over the conductors and  
the braided screen until the inside diameter of the level  
surface is flush with the cable sheath.  
• Push the compression element (2) onto the contacting  
ring (3). Screw the remaining shielding into the unit  
(2 + 3) by turning the compression element (2) while  
preventing the contacting ring (3) from turning.  
• Shorten the 3 power conductors to 63.5 mm, and  
18.5 mm for a contact cross section of 35 mm2  
18.0 mm for a contact cross section of 50 mm2  
7 mm for signal contacts of Ø 1.6 mm  
Dimensions for the assembly may differ depending on  
the cable variant.  
(0.75 – 1.5 mm2).  
• Crimp the conductors to the contacts. Observe  
settings for crimping pliers and positioner (please refer  
to the setting matrix for crimp contacts).  
• After assigning the connections, mount the contacts  
PHOENIX CONTACT  
60  
Power Connectors – PLUSCON circular  
M58 – P150 Series  
Cable connecting receptacles  
5
SL-5EP1N8A90..  
SL-7EP1N8A90..  
4
6
3
2
1
Clip the crimp contacts  
into the contact carrier (4)  
on the side.  
55  
55  
• Slide adapter (1) and compression element (2)  
(sealing ringand clamping cage) over the cable.  
• Strip the cable by 65 mm.  
they are.  
• Strip the wires:  
contacts, then the signal contacts on the side.  
• Fit the assembled unit in the insulating sleeve (5).  
• Guide the unit (2+3+4+5 ) into the housing (6).  
Note: Use the PE connection as orientation.  
• Screw the adapter (1) tight, torque 30 Nm.  
Note:  
13.8 mm for contact cross sections of 10 mm2 and  
16 mm2  
• Cut off and remove foil and other filling material.  
• Unbraid the braided screen and push back approx. half 16.8 mm for a contact cross section of 25 mm2  
of the length that has been stripped.  
18.5 mm for a contact cross section of 35 mm2  
18.0 mm for a contact cross section of 50 mm2  
7 mm for signal contacts of Ø 1.6 mm  
(0.75 – 1.5 mm2).  
• Push the contacting ring (3) over the conductors and  
the braided screen until the inside diameter of the level  
surface is flush with the cable sheath.  
Dimensions for the assembly may differ depending on  
the cable variant.  
• Push the compression element (2) onto the contacting • Crimp the conductors to the contacts. Observe  
ring (3). Screw the remaining shielding into the unit  
(2 + 3) by turning the compression element (2) while  
preventing the contacting ring (3) from turning.  
• Shorten the 3 power conductors to 63.5 mm, and  
leave the PE conductor and the signal conductors as  
settings for crimping pliers and positioner (please refer  
to the setting matrix for crimp contacts).  
• After assigning the connections, mount the contacts  
on the contact carrier (4).  
Procedure: First clip in the power contacts and PE  
PHOENIX CONTACT  
61  
Power Connectors – PLUSCON circular  
M58 – P150 Series  
Panel mounting connectors,  
straight  
SL-5EPWN8AWA00  
SL-7EPWN8AWA00  
4
5
M5 (not included in  
the scope of delivery)  
3
2
1
Clip the crimp contacts  
into the contact carrier (2)  
on the side.  
Installation dimensions  
Single wire-Ø max. 14 mm  
• Strip the wires:  
• After assigning the connections, mount the contacts  
on the contact carrier (2).  
13.8 mm for contact cross sections of 10 mm2 and  
16 mm2  
Procedure: First clip in the power contacts and PE  
contacts, then the signal contacts on the side.  
• Fit the assembled unit in the insulating sleeve (3).  
• Guide the unit (2) and (3) into the housing (4).  
Note: Use the PE connection as orientation.  
• Mount the support (1) in the housing (4).  
• Secure flange connector unit to the mounting panel  
using screws (5).  
16.8 mm for a contact cross section of 25 mm2  
18.5 mm for a contact cross section of 35 mm2  
18.0 mm for a contact cross section of 50 mm2  
7 mm for signal contacts of Ø 1.6 mm  
(0.75 – 1.5 mm2).  
• Push the conductors through the support (1).  
• Crimp the conductors to the contacts. Observe  
settings for crimping pliers (please refer to the setting  
matrix for crimp contacts).  
PHOENIX CONTACT  
62  
MNR 52004545/10.12.2008-00  
AI-0008-11  
© PHOENIX CONTACT 2008  
Industrial Connection Technology,  
Marking Systems and Mounting Material  
CLIPLINE  
Industrial Connectors  
PLUSCON  
www.phoenixcontact.com  
PCB Connection Technology  
and Electronic Housings  
COMBICON  
Surge Protection  
TRABTECH  
Signal Converters, Switching Devices,  
Power Sypply Units  
INTERFACE  
Components and Systems  
AUTOMATION  

相关型号:

1607690

CONN RCP HSG FMAL 4POS PNL MT RA
PHOENIX

1607691

Circular Connector,
PHOENIX

1607692

Circular Connector
PHOENIX

1607710

CONN RCPT HSNG MALE 6POS PNL MT
PHOENIX

1607711

CONN RCPT HSNG MALE 6POS PNL MT
PHOENIX

1607717

CONN PLG HSG FMALE 6POS INLINE
PHOENIX

1607718

CONN PLG HSG FMALE 6POS INLINE
PHOENIX

1607725

CONN RCP HSG FMAL 6POS PNL MT RA
PHOENIX

1607728

Circular Connector, 6 Contact(s), Gadolinium Zinc Alloy, Female, Crimp Terminal, ROHS COMPLIANT
PHOENIX

1607735

Circular Connector,
PHOENIX

1607738

CONN PLUG HSG MALE 8POS INLINE
PHOENIX

1607741

CONN RCPT HSG MALE 8POS INLINE
PHOENIX