1715400 [PHOENIX]
Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s),;![1715400](http://pdffile.icpdf.com/pdf2/p00230/img/icpdf/1715400_1347026_icpdf.jpg)
型号: | 1715400 |
厂家: | ![]() |
描述: | Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), 端子和端子排 |
文件: | 总4页 (文件大小:63K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
https://www.phoenixcontact.com/us/produkte/1715400
Printed-circuit board connector - MC 1,5/ 3-STF-3,5 BK - 1715400
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
Plug component, Nominal current: 8 A, Number of positions: 3, Pitch: 3.5 mm, Connection method: Screw
connection, Color: Black, Contact surface: Tin
Key commercial data
Packing unit
1 PCE
Minimum order quantity
1000 PCE
GTIN
Custom tariff number
Country of origin
85366990
GERMANY
Technical data
Dimensions / positions
Pitch
3.5 mm
7 mm
3
Dimension a
Number of positions
Technical data
Range of articles
MC 1,5/..-STF
EN-VDE
8 A
Connection in acc. with standard
Nominal current IN
Nominal voltage UN
160 V
Nominal cross section
1.5 mm²
300 V
Nominal voltage, UL/CUL Use Group B
Nominal current, UL/CUL Use Group B
Nominal voltage, UL/CUL Use Group D
Nominal current, UL/CUL Use Group D
8 A
300 V
8 A
Connection data
Conductor cross section solid min.
0.14 mm²
1.5 mm²
0.14 mm²
1.5 mm²
0.25 mm²
Conductor cross section solid max.
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section stranded, with ferrule without plastic sleeve min.
Conductor cross section stranded, with ferrule without plastic sleeve max. 1.5 mm²
25.04.2013 Page 1 / 4
https://www.phoenixcontact.com/us/produkte/1715400
Printed-circuit board connector - MC 1,5/ 3-STF-3,5 BK - 1715400
Technical data
Connection data
Conductor cross section stranded, with ferrule with plastic sleeve min.
Conductor cross section stranded, with ferrule with plastic sleeve max.
Conductor cross section AWG/kcmil min.
0.25 mm²
0.5 mm²
28
Conductor cross section AWG/kcmil max
16
2 conductors with same cross section, solid min.
2 conductors with same cross section, solid max.
2 conductors with same cross section, stranded min.
2 conductors with same cross section, stranded max.
0.08 mm²
0.5 mm²
0.08 mm²
0.75 mm²
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, min.
0.25 mm²
0.34 mm²
0.5 mm²
0.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, max.
2 conductors with same cross section, stranded, TWIN ferrules with plastic
sleeve, min.
2 conductors with same cross section, stranded, TWIN ferrules with plastic
sleeve, max.
Minimum AWG according to UL/CUL
Maximum AWG according to UL/CUL
30
14
Classifications
ETIM
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC001121
EC002638
EC002638
UNSPSC
UNSPSC 11
39121409
39121409
39121409
30211810
39121409
UNSPSC 12.01
UNSPSC 13.2
UNSPSC 6.01
UNSPSC 7.0901
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
272607xx
27260701
27260701
27260701
27260704
25.04.2013 Page 2 / 4
https://www.phoenixcontact.com/us/produkte/1715400
Printed-circuit board connector - MC 1,5/ 3-STF-3,5 BK - 1715400
Classifications
eCl@ss
eCl@ss 7.0
27440402
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / GOST / VDE Gutachten mit Fertigungsüberwachung / IECEE CB Scheme / GOST / CCA / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
UL Recognized
B
D
mm²/AWG/kcmil
30-14
8 A
30-14
8 A
Nominal current IN
Nominal voltage UN
300 V
300 V
cUL Recognized
B
D
mm²/AWG/kcmil
30-14
8 A
30-14
8 A
Nominal current IN
Nominal voltage UN
300 V
300 V
GOST
25.04.2013 Page 3 / 4
https://www.phoenixcontact.com/us/produkte/1715400
Printed-circuit board connector - MC 1,5/ 3-STF-3,5 BK - 1715400
Approvals
VDE Gutachten mit Fertigungsüberwachung
mm²/AWG/kcmil
0.2-1.5
8 A
Nominal current IN
Nominal voltage UN
160 V
IECEE CB Scheme
mm²/AWG/kcmil
0.2-1.5
8 A
Nominal current IN
Nominal voltage UN
160 V
GOST
CCA
mm²/AWG/kcmil
0.2-1.5
8 A
Nominal current IN
Nominal voltage UN
160 V
cULus Recognized
© Phoenix Contact 2013 - all rights reserved
http://www.phoenixcontact.com
25.04.2013 Page 4 / 4
相关型号: