Extract from the online  
catalog  
MKDS 3/ 2-5,08  
Order No.: 1711725  
The illustration shows a combination as a 15-position version  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1711725  
PC terminal block, Nominal current: 24 A, Nom. voltage: 400 V,  
Pitch: 5.08 mm, Number of positions: 2, Connection method: Screw  
connection, Mounting: Soldering, Conductor/PCB connection direction:  
0 °, Color: green, The article can be aligned to create different nos. of  
positions!  
Product notes  
WEEE/RoHS-compliant since:  
01/01/2003  
Commercial data  
GTIN (EAN)  
4
017918  
023713  
sales group  
E012  
Pack  
50 pcs.  
85369010  
http://  
Customs tariff  
Catalog page information  
www.download.phoenixcontact.com  
Please note that the data given  
here has been taken from the  
online catalog. For comprehensive  
information and data, please refer  
to the user documentation. The  
General Terms and Conditions of  
Use apply to Internet downloads.  
Page 97 (CC-2011)  
Technical data  
Dimensions / positions  
Length  
Height  
11.2 mm  
18 mm  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 1 / 6  
Jun 6, 2011  
MKDS 3/ 2-5,08 Order No.: 1711725  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1711725  
Pitch  
5.08 mm  
5.08 mm  
2
Dimension a  
Number of positions  
Pin dimensions  
Pin spacing  
0,9 x 0,9 mm  
15.24 mm  
1.3 mm  
M3  
Hole diameter  
Screw thread  
Tightening torque, min  
Tightening torque max  
0.5 Nm  
0.6 Nm  
Technical data  
Range of articles  
MKDS 3  
Insulating material group  
Rated surge voltage (III/3)  
Rated surge voltage (III/2)  
Rated surge voltage (II/2)  
Rated voltage (III/3)  
I
4 kV  
4 kV  
4 kV  
250 V  
Rated voltage (III/2)  
400 V  
Rated voltage (II/2)  
630 V  
Connection in acc. with standard  
Nominal current IN  
EN-VDE  
24 A  
Nominal cross section  
2.5 mm²  
Maximum load current  
28 A (with 4 mm² conductor cross section)  
Insulating material  
PA  
Inflammability class acc. to UL 94  
Internal cylindrical gage  
Stripping length  
V0  
A3  
8 mm  
300 V  
15 A  
300 V  
10 A  
Nominal voltage, UL/CUL Use Group B  
Nominal current, UL/CUL Use Group B  
Nominal voltage, UL/CUL Use Group D  
Nominal current, UL/CUL Use Group D  
Connection data  
Conductor cross section solid min.  
Conductor cross section solid max.  
Conductor cross section stranded min.  
0.2 mm²  
4 mm²  
0.2 mm²  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 2 / 6  
Jun 6, 2011  
MKDS 3/ 2-5,08 Order No.: 1711725  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1711725  
Conductor cross section stranded max.  
2.5 mm²  
Conductor cross section stranded, with ferrule  
without plastic sleeve min.  
0.25 mm²  
Conductor cross section stranded, with ferrule  
without plastic sleeve max.  
2.5 mm²  
0.25 mm²  
2.5 mm²  
Conductor cross section stranded, with ferrule  
with plastic sleeve min.  
Conductor cross section stranded, with ferrule  
with plastic sleeve max.  
Conductor cross section AWG/kcmil min.  
Conductor cross section AWG/kcmil max  
2 conductors with same cross section, solid min.  
2 conductors with same cross section, solid max.  
24  
12  
0.2 mm²  
1.5 mm²  
0.2 mm²  
2 conductors with same cross section, stranded  
min.  
2 conductors with same cross section, stranded  
max.  
1.5 mm²  
0.25 mm²  
0.75 mm²  
0.5 mm²  
1.5 mm²  
2 conductors with same cross section, stranded,  
ferrules without plastic sleeve, min.  
2 conductors with same cross section, stranded,  
ferrules without plastic sleeve, max.  
2 conductors with same cross section, stranded,  
TWIN ferrules with plastic sleeve, min.  
2 conductors with same cross section, stranded,  
TWIN ferrules with plastic sleeve, max.  
Minimum AWG according to UL/CUL  
Maximum AWG according to UL/CUL  
30  
12  
Certificates / Approvals  
Certification  
CCA, CSA, CUL, GL, GOST, SEV, UL  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 3 / 6  
Jun 6, 2011  
MKDS 3/ 2-5,08 Order No.: 1711725  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1711725  
Accessories  
Item  
Designation  
Description  
Assembly  
1703047  
RZ 1,25-MKDS 3  
Pitch spacer, for adjusting the pitches between MKDS and  
GMKDS terminal blocks in mixed rows, 1.25 mm thick  
General  
1733169  
EBP 2- 5  
Insertion bridge, fully insulated, for plug connectors with 5.0 or  
5.08 mm pitch, no. of positions: 2  
Marking  
1051993  
B-STIFT  
Marker pen, for manual labeling of unprinted Zack strips, smear-  
proof and waterproof, line thickness 0.5 mm  
0804293  
0805085  
0805412  
SK 5,08/3,8:FORTL.ZAHLEN  
Marker card, printed horizontally, self-adhesive, 12 identical  
decades marked 1-10, 11-20 etc. up to 91-(99)100, sufficient for  
120 terminal blocks  
SK 5,08/3,8:SO  
Marker card, special printing, self-adhesive, labeled acc. to  
customer requirements, 12 identical marker strips per card, max.  
25-position labeling per strip, color: white  
SK 5,08/3,8:UNBEDRUCKT  
Marker cards, unprinted, with pitch divisions, self-adhesive, 10-  
section marker strips, 12 strips per card, can be labeled with the  
M-PEN  
Tools  
1205053  
SZS 0,6X3,5  
Actuation tool, for ST terminal blocks, insulated, also suitable  
for use as a bladed screwdriver, size: 0.6 x 3.5 x 100 mm, 2-  
component grip, with non-slip grip  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 4 / 6  
Jun 6, 2011  
MKDS 3/ 2-5,08 Order No.: 1711725  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1711725  
Diagrams/Drawings  
Drilling plan/solder pad geometry  
Dimensioned drawing  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 5 / 6  
Jun 6, 2011  
MKDS 3/ 2-5,08 Order No.: 1711725  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1711725  
Address  
PHOENIX CONTACT Inc., USA  
586 Fulling Mill Road  
Middletown, PA 17057,USA  
Phone (800) 888-7388  
Fax (717) 944-1625  
http://www.phoenixcon.com  
© 2011 Phoenix Contact  
Technical modifications reserved;  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 6 / 6  
Jun 6, 2011  

相关型号:

1733172

Terminal Block Accessory, Insertion Bridge
PHOENIX

1733185

Interconnection Device, ROHS COMPLIANT
PHOENIX

1733198

Terminal Block Accessory
PHOENIX

17331E3

Aluminum Capacitors Axial High Temperature, DIN-Based
VISHAY

17333

Radial Lead Inductors
CANDD

173333M250Y

CAPACITOR, FILM/FOIL, POLYPROPYLENE, 0.033uF, THROUGH HOLE MOUNT, RADIAL LEADED
CDE

1733367

Connector Accessory,
PHOENIX

1733372

CONTACT H.D. CRIMP PIN 8AWG
PHOENIX

1733376

Barrier Strip Terminal Block,
PHOENIX

17333C

Radial Lead Inductors
MURATA

17334

Radial Lead Inductors
CANDD

1733411

PTSA 1,5/ 3-3,5-F WH BU RD
PHOENIX