Printed-circuit board connector - FKCN 2,5/ 8-ST-5,08 - 1754623  
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's  
documentation. Our General Terms of Use for Downloads are valid  
(http://phoenixcontact.com/download)  
Plug component, nominal current: 12 A, rated voltage (III/2): 320 V, number of positions: 8, pitch: 5.08 mm,  
connection method: Push-in spring connection, color: green, contact surface: Tin  
The figure shows a 10-position  
version of the product  
Why buy this product  
Time saving push-in connection, tools not required  
Intuitive use through colour coded actuation lever  
Extremely small design for the respective conductor cross section  
Quick and convenient testing using integrated test option  
Can be combined with the MSTB 2´,5 range  
Key Commercial Data  
Packing unit  
50 STK  
GTIN  
GTIN  
4046356330282  
Technical data  
Dimensions  
Length [ l ]  
Width [ w ]  
Height [ h ]  
Pitch  
27.1 mm  
40.64 mm  
10.9 mm  
5.08 mm  
35.56 mm  
Dimension a  
General  
Range of articles  
Type of contact  
FKCN 2,5/..-ST  
Female connector  
8
Number of positions  
Connection method  
Push-in spring connection  
02/09/2018 Page 1 / 4  
https://www.phoenixcontact.com/pi/products/1754623  
Printed-circuit board connector - FKCN 2,5/ 8-ST-5,08 - 1754623  
Technical data  
General  
Insulating material group  
Rated surge voltage (III/3)  
Rated surge voltage (III/2)  
Rated surge voltage (II/2)  
Rated voltage (III/3)  
I
4 kV  
4 kV  
4 kV  
320 V  
320 V  
630 V  
EN-VDE  
12 A  
2.5 mm²  
12 A  
PA  
Rated voltage (III/2)  
Rated voltage (II/2)  
Connection in acc. with standard  
Nominal current IN  
Nominal cross section  
Maximum load current  
Insulating material  
Flammability rating according to UL 94  
Stripping length  
V0  
10 mm  
Connection data  
Conductor cross section solid min.  
Conductor cross section solid max.  
Conductor cross section flexible min.  
Conductor cross section flexible max.  
0.2 mm²  
1.5 mm²  
0.2 mm²  
2.5 mm²  
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²  
Conductor cross section flexible, with ferrule without plastic sleeve max. 1.5 mm²  
Conductor cross section flexible, with ferrule with plastic sleeve min.  
Conductor cross section flexible, with ferrule with plastic sleeve max.  
Conductor cross section AWG min.  
0.25 mm²  
1.5 mm²  
24  
Conductor cross section AWG max.  
16  
Minimum AWG according to UL/CUL  
24  
Maximum AWG according to UL/CUL  
14  
Standards and Regulations  
Connection in acc. with standard  
EN-VDE  
CUL  
Flammability rating according to UL 94  
V0  
Environmental Product Compliance  
China RoHS  
Environmentally friendly use period: unlimited = EFUP-e  
No hazardous substances above threshold values  
Approvals  
Approvals  
02/09/2018 Page 2 / 4  
https://www.phoenixcontact.com/pi/products/1754623  
Printed-circuit board connector - FKCN 2,5/ 8-ST-5,08 - 1754623  
Approvals  
Approvals  
VDE Gutachten mit Fertigungsüberwachung / IECEE CB Scheme / EAC / IECEE CB Scheme / cULus Recognized  
Ex Approvals  
Approval details  
VDE Gutachten mit  
Fertigungsüberwachung  
http://www.vde.com/en/Institute/OnlineService/  
VDE-approved-products/Pages/Online-Search.aspx  
40041908  
mm²/AWG/kcmil  
0.2-2.5  
12 A  
Nominal current IN  
Nominal voltage UN  
400 V  
IECEE CB Scheme  
http://www.iecee.org/  
DE1-55379  
B.01742  
EAC  
IECEE CB Scheme  
http://www.iecee.org/  
DE1-58427  
mm²/AWG/kcmil  
0.2-2.5  
12 A  
Nominal current IN  
Nominal voltage UN  
400 V  
cULus Recognized  
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm E60425-19931012  
D
B
mm²/AWG/kcmil  
24-14  
10 A  
24-14  
10 A  
Nominal current IN  
Nominal voltage UN  
300 V  
300 V  
02/09/2018 Page 3 / 4  
https://www.phoenixcontact.com/pi/products/1754623  
Phoenix Contact 2018 © - all rights reserved  
http://www.phoenixcontact.com  
PHOENIX CONTACT GmbH & Co. KG  
Flachsmarktstr. 8  
32825 Blomberg  
Germany  
Tel. +49 5235 300  
Fax +49 5235 3 41200  
http://www.phoenixcontact.com  
02/09/2018 Page 4 / 4  

相关型号:

1754625-1

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1754625-2

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1754625-3

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1754627

Barrier Strip Terminal Block, 12A, 2.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1754630

Modular Terminal Block, 12A, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1754656

Strip Terminal Block, 12A, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1754669

Barrier Strip Terminal Block, 12A, 2.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1754685

Barrier Strip Terminal Block, 12A, 2.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1754698

Strip Terminal Block, 12A, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1754700-1

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1754700-2

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1754700-3

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE