Barrier Strip Terminal Block, 41A, 4mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT;
1777561
型号: 1777561
厂家: PHOENIX CONTACT    PHOENIX CONTACT
描述:

Barrier Strip Terminal Block, 41A, 4mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT

端子和端子排
文件: 总4页 (文件大小:124K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
https://www.phoenixcontact.com/pi/products/1777561  
PCB terminal block - MKDS 5N HV/ 4-ZB-6,35 - 1777561  
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's  
documentation. Our General Terms of Use for Downloads are valid  
(http://phoenixcontact.com/download)  
PCB terminal block, nominal current: 41 A, nom. voltage: 1000 V, pitch: 6.35 mm, number of positions:  
4, connection method: Screw connection with tension sleeve, mounting: Wave soldering, conductor/PCB  
connection direction: 0 °, color: green  
The figure shows the 5-pos. version  
Why buy this product  
Well-known connection principle allows worldwide use  
Low temperature rise, thanks to maximum contact force  
Allows connection of two conductors  
Unrestricted 600-V-UL approval thanks to compact zig-zag pinning  
Key Commercial Data  
Packing unit  
50 STK  
GTIN  
GTIN  
4046356522342  
Technical data  
Dimensions  
Length [ l ]  
15.85 mm  
6.35 mm  
19.05 mm  
25.4 mm  
27 mm  
Pitch  
Dimension a  
Width [ w ]  
Constructional height  
Height [ h ]  
32.5 mm  
5 mm  
Solder pin [P]  
Pin dimensions  
Pin spacing  
Hole diameter  
0,9 x 0,9 mm  
9 mm  
1.3 mm  
General  
02/09/2018 Page 1 / 4  
https://www.phoenixcontact.com/pi/products/1777561  
PCB terminal block - MKDS 5N HV/ 4-ZB-6,35 - 1777561  
Technical data  
General  
Range of articles  
MKDS 5 N HV  
I
Insulating material group  
Rated surge voltage (III/3)  
Rated surge voltage (III/2)  
Rated surge voltage (II/2)  
Rated voltage (III/3)  
8 kV  
8 kV  
8 kV  
800 V  
1000 V  
1000 V  
EN-VDE  
41 A  
Rated voltage (III/2)  
Rated voltage (II/2)  
Connection in acc. with standard  
Nominal current IN  
Nominal cross section  
Maximum load current  
Insulating material  
4 mm²  
41 A  
PA  
Solder pin surface  
Sn  
Flammability rating according to UL 94  
Stripping length  
V0  
8 mm  
4
Number of positions  
Screw thread  
M3  
Tightening torque, min  
Tightening torque max  
0.5 Nm  
0.6 Nm  
Connection data  
Conductor cross section solid min.  
Conductor cross section solid max.  
Conductor cross section flexible min.  
Conductor cross section flexible max.  
0.2 mm²  
6 mm²  
0.2 mm²  
4 mm²  
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.2 mm²  
Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²  
Conductor cross section flexible, with ferrule with plastic sleeve min.  
Conductor cross section flexible, with ferrule with plastic sleeve max.  
Conductor cross section AWG min.  
0.25 mm²  
4 mm²  
24  
Conductor cross section AWG max.  
10  
2 conductors with same cross section, solid min.  
2 conductors with same cross section, solid max.  
2 conductors with same cross section, stranded min.  
2 conductors with same cross section, stranded max.  
0.2 mm²  
1.5 mm²  
0.2 mm²  
1.5 mm²  
2 conductors with same cross section, stranded, ferrules without plastic  
sleeve, min.  
0.25 mm²  
0.75 mm²  
0.5 mm²  
2 conductors with same cross section, stranded, ferrules without plastic  
sleeve, max.  
2 conductors with same cross section, stranded, TWIN ferrules with  
plastic sleeve, min.  
02/09/2018 Page 2 / 4  
https://www.phoenixcontact.com/pi/products/1777561  
PCB terminal block - MKDS 5N HV/ 4-ZB-6,35 - 1777561  
Technical data  
Connection data  
2 conductors with same cross section, stranded, TWIN ferrules with  
plastic sleeve, max.  
2.5 mm²  
Standards and Regulations  
Connection in acc. with standard  
EN-VDE  
CUL  
Flammability rating according to UL 94  
V0  
Environmental Product Compliance  
China RoHS  
Environmentally Friendly Use Period = 50  
For details about hazardous substances go to tab “Downloads”,  
Category “Manufacturer's declaration”  
Drawings  
Drilling diagram  
Diagram  
a
80  
70  
60  
50  
40  
30  
20  
3,18  
6,35  
= 6 mm2  
10  
0
0
20  
40  
60  
80  
100  
Ambient temperature [°C]  
Type: MKDS 5N HV/...-ZB-6,35  
Tested in accordance with DIN EN 60512-5-2:2003-01  
Reduction factor = 1  
Number of positions: 5  
Dimensional drawing  
15,85  
a+6,35  
9
2,1 3,18  
6,35  
a
Approvals  
Approvals  
Approvals  
SEV / CCA / EAC / cULus Recognized  
02/09/2018 Page 3 / 4  
https://www.phoenixcontact.com/pi/products/1777561  
PCB terminal block - MKDS 5N HV/ 4-ZB-6,35 - 1777561  
Approvals  
Ex Approvals  
Approval details  
SEV  
https://www.electrosuisse.ch/en/meta/shop/product-certificates.html  
IK-3248  
mm²/AWG/kcmil  
4
Nominal current IN  
Nominal voltage UN  
32 A  
1000 V  
CCA  
IK-3249  
mm²/AWG/kcmil  
4
Nominal voltage UN  
1000 V  
EAC  
B.01742  
cULus Recognized  
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm E60425-19770427  
C
B
mm²/AWG/kcmil  
30-10  
30 A  
30-10  
30 A  
Nominal current IN  
Nominal voltage UN  
600 V  
600 V  
Phoenix Contact 2018 © - all rights reserved  
http://www.phoenixcontact.com  
PHOENIX CONTACT GmbH & Co. KG  
Flachsmarktstr. 8  
32825 Blomberg  
Germany  
Tel. +49 5235 300  
Fax +49 5235 3 41200  
http://www.phoenixcontact.com  
02/09/2018 Page 4 / 4  

相关型号:

1777574

Barrier Strip Terminal Block
PHOENIX

1777587

Barrier Strip Terminal Block, 41A, 4mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1777590

Barrier Strip Terminal Block,
PHOENIX

1777600

CONN TERM BLK 8POS 6.35MM GREEN
PHOENIX

1777600000

Cable glands
WEIDMULLER

1777610000

Cable glands
WEIDMULLER

1777620000

Cable glands
WEIDMULLER

1777626

Barrier Strip Terminal Block
PHOENIX

1777630000

Cable glands
WEIDMULLER

1777633

MSTB 2.5/ 7-ST-5.08 (1357)
PHOENIX

1777639

TERM BLOCK
PHOENIX

1777640000

Cable glands
WEIDMULLER