1790364 [PHOENIX]
Modular Terminal Block, 17.5A, 1.5mm2,;![1790364](http://pdffile.icpdf.com/pdf2/p00310/img/icpdf/1790364_1867578_icpdf.jpg)
型号: | 1790364 |
厂家: | ![]() |
描述: | Modular Terminal Block, 17.5A, 1.5mm2, 端子和端子排 |
文件: | 总5页 (文件大小:132K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Extract from the online
catalog
FFKDSA/V1-7,62
Order No.: 1790364
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1790364
PC terminal block, Nominal current: 17.5 A, Nom. voltage: 500
V, Pitch: 7.62 mm, Number of positions: 1, Type of connection:
Spring-cage conn., Assembly: Soldering, Conductor/PCB connection
direction: 90 °, Color: green, The article can be aligned to create
different nos. of positions!
Product notes
WEEE/RoHS-compliant since:
01/01/2003
Commercial data
EAN
4017918044275
50 pcs.
Pack
Customs tariff
Weight/Piece
Catalog page information
85369010
0.001474 KG
Page 119 (CC-2009)
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Dimensions / positions
Length
12.7 mm
7.62 mm
1
Pitch
Number of positions
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 1 / 5
Feb 17, 2010
FFKDSA/V1-7,62 Order No.: 1790364
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1790364
Pin dimensions
Hole diameter
0,5 x 1 mm
1.3 mm
Technical data
Insulating material group
Rated surge voltage (III/3)
Rated surge voltage (III/2)
Rated surge voltage (II/2)
Rated voltage (III/2)
I
6 kV
6 kV
6 kV
630 V
1000 V
EN-VDE
17.5 A
500 V
1.5 mm²
Rated voltage (II/2)
Connection in acc. with standard
Nominal current IN
Nominal voltage UN
Nominal cross section
Maximum load current
17.5 A (with 1.5 mm2 conductor cross section)
Insulating material
PA
Inflammability class acc. to UL 94
Stripping length
V0
10 mm
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section stranded min.
Conductor cross section stranded max.
0.2 mm²
1.5 mm²
0.2 mm²
1.5 mm²
0.25 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve min.
Conductor cross section stranded, with ferrule
without plastic sleeve max.
0.75 mm²
0.25 mm²
0.75 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve min.
Conductor cross section stranded, with ferrule
with plastic sleeve max.
Conductor cross section AWG/kcmil min.
Conductor cross section AWG/kcmil max
24
16
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 2 / 5
Feb 17, 2010
FFKDSA/V1-7,62 Order No.: 1790364
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1790364
Certificates / Approvals
Certification
CCA, CSA, CUL, GOST, KEMA, UL
CSA
Nominal voltage UN
Nominal current IN
AWG/kcmil
300 V
10 A
16
CUL
Nominal voltage UN
Nominal current IN
AWG/kcmil
300 V
10 A
22-16
UL
Nominal voltage UN
Nominal current IN
AWG/kcmil
300 V
10 A
22-16
Accessories
Item
Designation
Description
Marking
0804552
SK 7,62/5:FORTL.ZAHLEN
Marker card, printed horizontally, self-adhesive, 10-section marker
strip, 10 identical decades marked 1-10, 11-20 etc. up to 91-100,
sufficient for 100 terminal blocks
Additional products
Item
Designation
Description
General
1790490
FFKDSA1/V1-7,62
PC terminal block, Nominal current: 17.5 A, Nom. voltage: 500
V, Pitch: 7.62 mm, Number of positions: 1, Type of connection:
Spring-cage connection, Assembly: Soldering, Conductor/PCB
connection direction: 90 °, Color: green, The article can be aligned
to create different nos. of positions!
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 3 / 5
Feb 17, 2010
FFKDSA/V1-7,62 Order No.: 1790364
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1790364
Diagrams/Drawings
Drilling plan/solder pad geometry
Dimensioned drawing
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 4 / 5
Feb 17, 2010
FFKDSA/V1-7,62 Order No.: 1790364
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1790364
Address
PHOENIX CONTACT Inc., USA
586 Fulling Mill Road
Middletown, PA 17057,USA
Phone (800) 888-7388
Fax (717) 944-1625
http://www.phoenixcon.com
© 2010 Phoenix Contact
Technical modifications reserved;
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 5 / 5
Feb 17, 2010