1838158 [PHOENIX]

Barrier Strip Terminal Block,;
1838158
型号: 1838158
厂家: PHOENIX CONTACT    PHOENIX CONTACT
描述:

Barrier Strip Terminal Block,

端子和端子排
文件: 总4页 (文件大小:85K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
https://www.phoenixcontact.com/in/products/1838158  
Printed-circuit board connector - FRONT-MSTB 2,5/13-ST-5,08  
GY - 1838158  
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's  
documentation. Our General Terms of Use for Downloads are valid  
(http://phoenixcontact.com/download)  
PCB connector, nominal current: 12 A, number of positions: 13, pitch: 5.08 mm, connection method: Front  
screw connection, color: gray, contact surface: Tin  
The figure shows a 10-position  
version of the product  
Your advantages  
Well-known connection principle allows worldwide use  
Optimized for tight installation situations: operation and conductor connection from one direction  
Low temperature rise, thanks to maximum contact force  
Allows connection of two conductors  
Key Commercial Data  
Packing unit  
1
GTIN  
GTIN  
4017918262983  
85366990  
Custom tariff number  
Technical data  
Dimensions  
Length [ l ]  
Width [ w ]  
Height [ h ]  
Pitch  
27.2 mm  
66.04 mm  
15 mm  
5.08 mm  
60.96 mm  
Dimension a  
General  
Range of articles  
FRONT-MSTB 2,5/..-ST  
13  
Number of positions  
01/17/2019 Page 1 / 4  
https://www.phoenixcontact.com/in/products/1838158  
Printed-circuit board connector - FRONT-MSTB 2,5/13-ST-5,08  
GY - 1838158  
Technical data  
General  
Connection method  
Front screw connection  
Rated voltage (III/3)  
250 V  
Connection in acc. with standard  
Nominal current IN  
EN-VDE  
12 A  
Nominal cross section  
2.5 mm²  
Connection data  
Conductor cross section solid min.  
Conductor cross section solid max.  
Conductor cross section flexible min.  
Conductor cross section flexible max.  
0.34 mm²  
2.5 mm²  
0.2 mm²  
2.5 mm²  
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²  
Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²  
Conductor cross section flexible, with ferrule with plastic sleeve min.  
Conductor cross section flexible, with ferrule with plastic sleeve max.  
Conductor cross section AWG min.  
0.25 mm²  
2.5 mm²  
24  
Conductor cross section AWG max.  
12  
2 conductors with same cross section, solid min.  
2 conductors with same cross section, solid max.  
2 conductors with same cross section, stranded min.  
2 conductors with same cross section, stranded max.  
0.2 mm²  
1.5 mm²  
0.2 mm²  
1.5 mm²  
2 conductors with same cross section, stranded, ferrules without plastic  
sleeve, min.  
0.25 mm²  
1 mm²  
2 conductors with same cross section, stranded, ferrules without plastic  
sleeve, max.  
2 conductors with same cross section, stranded, TWIN ferrules with  
plastic sleeve, min.  
0.5 mm²  
1 mm²  
2 conductors with same cross section, stranded, TWIN ferrules with  
plastic sleeve, max.  
Minimum AWG according to UL/CUL  
Maximum AWG according to UL/CUL  
30  
12  
Standards and Regulations  
Connection in acc. with standard  
EN-VDE  
CSA  
Environmental Product Compliance  
China RoHS  
Environmentally friendly use period: unlimited = EFUP-e  
No hazardous substances above threshold values  
01/17/2019 Page 2 / 4  
https://www.phoenixcontact.com/in/products/1838158  
Printed-circuit board connector - FRONT-MSTB 2,5/13-ST-5,08  
GY - 1838158  
Classifications  
eCl@ss  
eCl@ss 4.0  
eCl@ss 4.1  
eCl@ss 5.0  
eCl@ss 5.1  
eCl@ss 6.0  
eCl@ss 7.0  
eCl@ss 8.0  
eCl@ss 9.0  
272607xx  
27260701  
27260701  
27260700  
27260700  
27440309  
27440309  
27440309  
ETIM  
ETIM 3.0  
ETIM 4.0  
ETIM 5.0  
ETIM 6.0  
EC001121  
EC002638  
EC002638  
EC002638  
UNSPSC  
UNSPSC 6.01  
UNSPSC 7.0901  
UNSPSC 11  
30211810  
39121409  
39121409  
39121409  
39121409  
UNSPSC 12.01  
UNSPSC 13.2  
Approvals  
Approvals  
Approvals  
CSA / IECEE CB Scheme / VDE Gutachten mit Fertigungsüberwachung / EAC / cULus Recognized  
Ex Approvals  
Approval details  
CSA  
http://www.csagroup.org/services-industries/product-listing/  
13631  
D
B
Nominal voltage UN  
Nominal current IN  
300 V  
10 A  
300 V  
15 A  
01/17/2019 Page 3 / 4  
https://www.phoenixcontact.com/in/products/1838158  
Printed-circuit board connector - FRONT-MSTB 2,5/13-ST-5,08  
GY - 1838158  
Approvals  
D
B
mm²/AWG/kcmil  
22-12  
22-12  
IECEE CB Scheme  
http://www.iecee.org/  
DE1-58978-B1B2  
Nominal voltage UN  
Nominal current IN  
mm²/AWG/kcmil  
250 V  
12 A  
0.34-2.5  
VDE Gutachten mit  
Fertigungsüberwachung  
http://www2.vde.com/de/Institut/Online-Service/  
VDE-gepruefteProdukte/Seiten/Online-Suche.aspx  
40004701  
Nominal voltage UN  
Nominal current IN  
mm²/AWG/kcmil  
250 V  
12 A  
0.34-2.5  
EAC  
B.01742  
cULus Recognized  
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm E60425-19931011  
B
D
Nominal voltage UN  
Nominal current IN  
mm²/AWG/kcmil  
300 V  
10 A  
300 V  
15 A  
30-12  
30-12  
Phoenix Contact 2019 © - all rights reserved  
http://www.phoenixcontact.com  
01/17/2019 Page 4 / 4  

相关型号:

1838160

Barrier Strip Terminal Block,
PHOENIX

1838173

Barrier Strip Terminal Block,
PHOENIX

1838186

Barrier Strip Terminal Block,
PHOENIX

1838199

Barrier Strip Terminal Block,
PHOENIX

1838209

Barrier Strip Terminal Block,
PHOENIX

1838212

Barrier Strip Terminal Block,
PHOENIX

1838225

Barrier Strip Terminal Block,
PHOENIX

1838226

PC 4/ 4-ST-7,62 BK
PHOENIX

1838242

Barrier Strip Terminal Block
PHOENIX

1838267

Barrier Strip Terminal Block,
PHOENIX

1838268

Barrier Strip Terminal Block
PHOENIX

1838270

Barrier Strip Terminal Block,
PHOENIX