1858028 [PHOENIX]
Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT;型号: | 1858028 |
厂家: | PHOENIX CONTACT |
描述: | Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT 端子和端子排 |
文件: | 总6页 (文件大小:126K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Extract from the online
catalog
IMC 1,5/16-ST-3,81
Order No.: 1858028
The figure shows a 10-position version of the product
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1858028
Plug component, Nominal current: 8 A, Nom. voltage: 160 V,
Pitch: 3.81 mm, Number of positions: 16, Connection type: Screw
connection, Color: green
Product notes
WEEE/RoHS-compliant since:
01/01/2003
Commercial data
EAN
4017918144265
50 pcs.
Pack
Customs tariff
Weight/Piece
Catalog page information
85366990
0.0127 KG
http://
Page 148 (CC-2009)
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Dimensions / positions
Pitch
3.81 mm
57.15 mm
16
Dimension a
Number of positions
Screw thread
M2
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 1 / 6
Feb 17, 2010
IMC 1,5/16-ST-3,81 Order No.: 1858028
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1858028
Tightening torque, min
Tightening torque max
0.22 Nm
0.25 Nm
Technical data
Insulating material group
Rated surge voltage (III/3)
Rated surge voltage (III/2)
Rated surge voltage (II/2)
Rated voltage (III/2)
I
2.5 kV
2.5 kV
2.5 kV
160 V
320 V
EN-VDE
8 A
Rated voltage (II/2)
Connection in acc. with standard
Nominal current IN
Nominal voltage UN
160 V
1.5 mm²
Nominal cross section
Maximum load current
8 A (with 1.5 mm2 conductor cross section)
Insulating material
PA
Inflammability class acc. to UL 94
Internal cylindrical gage
Stripping length
V0
A1
7 mm
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section stranded min.
Conductor cross section stranded max.
0.14 mm²
1.5 mm²
0.14 mm²
1.5 mm²
0.25 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve min.
Conductor cross section stranded, with ferrule
without plastic sleeve max.
1.5 mm²
0.25 mm²
0.5 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve min.
Conductor cross section stranded, with ferrule
with plastic sleeve max.
Conductor cross section AWG/kcmil min.
Conductor cross section AWG/kcmil max
2 conductors with same cross section, solid min.
2 conductors with same cross section, solid max.
28
16
0.08 mm²
0.5 mm²
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 2 / 6
Feb 17, 2010
IMC 1,5/16-ST-3,81 Order No.: 1858028
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1858028
2 conductors with same cross section, stranded
min.
0.08 mm²
0.75 mm²
0.2 mm²
0.34 mm²
0.5 mm²
0.5 mm²
2 conductors with same cross section, stranded
max.
2 conductors with same cross section, stranded,
ferrules without plastic sleeve, min.
2 conductors with same cross section, stranded,
ferrules without plastic sleeve, max.
2 conductors with same cross section, stranded,
TWIN ferrules with plastic sleeve, min.
2 conductors with same cross section, stranded,
TWIN ferrules with plastic sleeve, max.
Certificates / Approvals
Certification
CB, CUL, GOST, UL, VDE-PZI
CUL
Nominal voltage UN
Nominal current IN
AWG/kcmil
300 V
8 A
30-14
UL
Nominal voltage UN
Nominal current IN
AWG/kcmil
300 V
8 A
30-14
Accessories
Item
Designation
Description
General
1834343
KGG-MC 1,5/ 2
KGG-MC 1,5/ 6
Cable housing, Pitch: 3.81 mm, Number of positions: 2,
Dimension a: 10.01 mm, Color: green
1834385
Cable housing, Pitch: 3.81 mm, Number of positions: 6,
Dimension a: 25.25 mm, Color: green
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 3 / 6
Feb 17, 2010
IMC 1,5/16-ST-3,81 Order No.: 1858028
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1858028
Marking
0804109
SK 3,81/2,8:FORTL.ZAHLEN
Marker card, printed horizontally, self-adhesive, 10-section marker
strip, 14 identical decades marked 1-10, 11-20 etc. up to 91-
(99)100, sufficient for 140 terminal blocks
Plug/Adapter
1734634
CP-MSTB
Keying profile, is inserted into the slot on the plug or inverted
header, red insulating material
Tools
1205037
SZS 0,4X2,5
Screwdriver, bladed, matches all screw terminal blocks up to 1.5
mm² connection cross section, blade: 0.4 x 2.5 mm
Additional products
Item
Designation
Description
General
1851180
FK-MCP 1,5/16-ST-3,81
Plug component, Nominal current: 8 A, Nom. voltage: 160 V,
Pitch: 3.81 mm, Number of positions: 16, Connection type: Spring-
cage conn., Color: green
1850806
FRONT-MC 1,5/16-ST-3,81
Plug component, Nominal current: 8 A, Nom. voltage: 160 V,
Pitch: 3.81 mm, Number of positions: 16, Connection type: Screw
connection, Color: green
1862713
1875564
1803714
IMC 1,5/16-G-3,81
IMCV 1,5/16-G-3,81
MC 1,5/16-ST-3,81
Header, Nominal current: 8 A, Nom. voltage: 160 V, Pitch: 3.81
mm, Number of positions: 16, Color: green, Assembly: Soldering
Header, Nominal current: 8 A, Nom. voltage: 160 V, Pitch: 3.81
mm, Number of positions: 16, Color: green, Assembly: Soldering
Plug component, Nominal current: 8 A, Nom. voltage: 160 V,
Pitch: 3.81 mm, Number of positions: 16, Connection type: Screw
connection, Color: green
1852312
1827266
1827114
1897539
MCC 1/16-STZ-3,81
MCVR 1,5/16-ST-3,81
MCVW 1,5/16-ST-3,81
QC 0,5/16-ST-3,81
Plug component, Nominal current: 8 A, Nom. voltage: 160 V,
Pitch: 3.81 mm, Number of positions: 16, Connection type: Crimp
connection
Plug component, Nominal current: 8 A, Nom. voltage: 160 V,
Pitch: 3.81 mm, Number of positions: 16, Connection type: Screw
connection, Color: green
Plug component, Nominal current: 8 A, Nom. voltage: 160 V,
Pitch: 3.81 mm, Number of positions: 16, Connection type: Screw
connection, Color: green
Plug component, Nominal current: 6 A, Nom. voltage: 320 V,
Pitch: 3.81 mm, Number of positions: 16, Connection type:
Insulation displacement connection QUICKON, Color: green
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 4 / 6
Feb 17, 2010
IMC 1,5/16-ST-3,81 Order No.: 1858028
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1858028
Diagrams/Drawings
Dimensioned drawing
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 5 / 6
Feb 17, 2010
IMC 1,5/16-ST-3,81 Order No.: 1858028
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1858028
Address
PHOENIX CONTACT Inc., USA
586 Fulling Mill Road
Middletown, PA 17057,USA
Phone (800) 888-7388
Fax (717) 944-1625
http://www.phoenixcon.com
© 2010 Phoenix Contact
Technical modifications reserved;
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 6 / 6
Feb 17, 2010
相关型号: