1868173 [PHOENIX]

Barrier Strip Terminal Block, 12A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT;
1868173
型号: 1868173
厂家: PHOENIX CONTACT    PHOENIX CONTACT
描述:

Barrier Strip Terminal Block, 12A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT

端子和端子排
文件: 总5页 (文件大小:128K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Extract from the online  
catalog  
MKDSFW 1,5/ 7-3,5  
Order No.: 1868173  
The figure shows a 10-position version of the product  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1868173  
PC terminal block, Nominal current: 12 A, Nom. voltage: 160 V,  
Pitch: 3.5 mm, Number of positions: 7, Type of connection: Screw  
connection, Mounting: Soldering, Conductor/PCB connection direction:  
90 °, Color: green  
Product notes  
WEEE/RoHS-compliant since:  
01/01/2003  
Commercial data  
GTIN (EAN)  
4
017918  
133832  
Note  
Made-to-order  
E006  
sales group  
Pack  
http://  
50 pcs.  
www.download.phoenixcontact.com  
Please note that the data given  
here has been taken from the  
online catalog. For comprehensive  
information and data, please refer  
to the user documentation. The  
General Terms and Conditions of  
Use apply to Internet downloads.  
Customs tariff  
Catalog page information  
85369010  
Page 55 (CC-2009)  
Technical data  
Dimensions / positions  
Length  
11.3 mm  
3.5 mm  
31 mm  
Pitch  
Dimension a  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 1 / 5  
Jan 19, 2011  
MKDSFW 1,5/ 7-3,5 Order No.: 1868173  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1868173  
Number of positions  
Pin dimensions  
7
0,5 x 0,9 mm  
1.3 mm  
M2  
Hole diameter  
Screw thread  
Tightening torque, min  
Tightening torque max  
0.22 Nm  
0.25 Nm  
Technical data  
Range of articles  
MKDSFW 1,5  
I
Insulating material group  
Rated surge voltage (III/3)  
Rated surge voltage (III/2)  
Rated surge voltage (II/2)  
Rated voltage (III/2)  
2.5 kV  
2.5 kV  
2.5 kV  
160 V  
Rated voltage (II/2)  
320 V  
Connection in acc. with standard  
Nominal current IN  
EN-VDE  
12 A  
Nominal voltage UN  
160 V  
Nominal cross section  
Maximum load current  
1.5 mm²  
12 A (with 1.5 mm2 conductor cross section)  
Insulating material  
PA  
Inflammability class acc. to UL 94  
Internal cylindrical gage  
V0  
A1  
Stripping length  
6 mm  
300 V  
10 A  
300 V  
10 A  
Nominal voltage, UL/CUL Use Group B  
Nominal current, UL/CUL Use Group B  
Nominal voltage, UL/CUL Use Group D  
Nominal current, UL/CUL Use Group D  
Connection data  
Conductor cross section solid min.  
Conductor cross section solid max.  
Conductor cross section stranded min.  
Conductor cross section stranded max.  
0.14 mm²  
1.5 mm²  
0.14 mm²  
1.5 mm²  
0.25 mm²  
Conductor cross section stranded, with ferrule  
without plastic sleeve min.  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 2 / 5  
Jan 19, 2011  
MKDSFW 1,5/ 7-3,5 Order No.: 1868173  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1868173  
Conductor cross section stranded, with ferrule  
without plastic sleeve max.  
1.5 mm²  
0.25 mm²  
1.5 mm²  
Conductor cross section stranded, with ferrule  
with plastic sleeve min.  
Conductor cross section stranded, with ferrule  
with plastic sleeve max.  
Conductor cross section AWG/kcmil min.  
Conductor cross section AWG/kcmil max  
2 conductors with same cross section, solid min.  
2 conductors with same cross section, solid max.  
26  
16  
0.14 mm²  
0.75 mm²  
0.14 mm²  
2 conductors with same cross section, stranded  
min.  
2 conductors with same cross section, stranded  
max.  
0.75 mm²  
0.25 mm²  
0.5 mm²  
0.5 mm²  
1 mm²  
2 conductors with same cross section, stranded,  
ferrules without plastic sleeve, min.  
2 conductors with same cross section, stranded,  
ferrules without plastic sleeve, max.  
2 conductors with same cross section, stranded,  
TWIN ferrules with plastic sleeve, min.  
2 conductors with same cross section, stranded,  
TWIN ferrules with plastic sleeve, max.  
Minimum AWG according to UL/CUL  
Maximum AWG according to UL/CUL  
30  
14  
Certificates / Approvals  
Certification  
CUL, GOST, UL  
Accessories  
Item  
Designation  
Description  
Marking  
0804073  
SK 3,5/2,8:FORTL.ZAHLEN  
Marker card, printed horizontally, self-adhesive, 10-section marker  
strip, 14 identical decades marked 1-10, 11-20 etc. up to 91-100,  
sufficient for 140 terminal blocks  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 3 / 5  
Jan 19, 2011  
MKDSFW 1,5/ 7-3,5 Order No.: 1868173  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1868173  
Tools  
1205037  
SZS 0,4X2,5 VDE  
Screwdriver, bladed, VDE insulated, size: 0.4 x 2.5 x 80 mm, 2-  
component grip, with non-slip grip  
Diagrams/Drawings  
Drilling plan/solder pad geometry  
Dimensioned drawing  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 4 / 5  
Jan 19, 2011  
MKDSFW 1,5/ 7-3,5 Order No.: 1868173  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1868173  
Address  
PHOENIX CONTACT Inc., USA  
586 Fulling Mill Road  
Middletown, PA 17057,USA  
Phone (800) 888-7388  
Fax (717) 944-1625  
http://www.phoenixcon.com  
© 2010 Phoenix Contact  
Technical modifications reserved;  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 5 / 5  
Jan 19, 2011  

相关型号:

1868186

Barrier Strip Terminal Block, 12A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

18681E3

Aluminum Capacitors Axial High Temperature, DIN-Based
VISHAY

18682

Axial Lead Inductors
CANDD

1868212

Barrier Strip Terminal Block, 12A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1868254

Barrier Strip Terminal Block,
PHOENIX

1868296

Barrier Strip Terminal Block,
PHOENIX

18682C

Axial Lead Inductors
MURATA

18683

Axial Lead Inductors
CANDD

1868335

Barrier Strip Terminal Block,
PHOENIX

186838-01

Configurable Signal Conditioning Enclosure
NI

1868380

TERM BLOCK
PHOENIX

18683C

Axial Lead Inductors
MURATA