1897694 [PHOENIX]

Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT;
1897694
型号: 1897694
厂家: PHOENIX CONTACT    PHOENIX CONTACT
描述:

Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT

端子和端子排
文件: 总5页 (文件大小:174K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Extract from the online  
catalog  
EMKDS 1,5/ 2-5,08  
Order No.: 1897694  
The illustration shows a 12-position version  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1897694  
PC terminal block, Nominal current: 8 A, Nom. voltage: 250 V,  
Pitch: 5.08 mm, Number of positions: 2, Type of connection: Screw  
connection, Assembly: Press-in, Conductor/PCB connection direction:  
0 °, Color: green  
Product notes  
WEEE/RoHS-compliant since:  
01/01/2003  
Commercial data  
EAN  
4017918165406  
50 pcs.  
Pack  
Customs tariff  
Weight/Piece  
Catalog page information  
85369010  
0.00191 KG  
Page 19 (CC-2005)  
http://  
www.download.phoenixcontact.com  
Please note that the data given  
here has been taken from the  
online catalog. For comprehensive  
information and data, please refer  
to the user documentation. The  
General Terms and Conditions of  
Use apply to Internet downloads.  
Technical data  
Dimensions / positions  
Pitch  
5.08 mm  
2
Number of positions  
Pin dimensions  
Hole diameter  
1,4 mm  
1.15 mm  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 1 / 5  
Feb 17, 2010  
EMKDS 1,5/ 2-5,08 Order No.: 1897694  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1897694  
Screw thread  
M2  
Tightening torque, min  
Tightening torque max  
0.22 Nm  
0.25 Nm  
Technical data  
Insulating material group  
Rated surge voltage (III/3)  
Rated surge voltage (III/2)  
Rated surge voltage (II/2)  
Rated voltage (III/2)  
I
4 kV  
4 kV  
4 kV  
320 V  
630 V  
EN-VDE  
8 A  
Rated voltage (II/2)  
Connection in acc. with standard  
Nominal current IN  
Nominal voltage UN  
250 V  
1.5 mm²  
Nominal cross section  
Maximum load current  
8 A (with 1.5 mm2 conductor cross section)  
Insulating material  
PA  
Inflammability class acc. to UL 94  
Internal cylindrical gage  
Stripping length  
V0  
A1  
7 mm  
Connection data  
Conductor cross section solid min.  
Conductor cross section solid max.  
Conductor cross section stranded min.  
Conductor cross section stranded max.  
0.14 mm²  
1.5 mm²  
0.14 mm²  
1.5 mm²  
0.25 mm²  
Conductor cross section stranded, with ferrule  
without plastic sleeve min.  
Conductor cross section stranded, with ferrule  
without plastic sleeve max.  
1.5 mm²  
0.25 mm²  
0.5 mm²  
Conductor cross section stranded, with ferrule  
with plastic sleeve min.  
Conductor cross section stranded, with ferrule  
with plastic sleeve max.  
Conductor cross section AWG/kcmil min.  
Conductor cross section AWG/kcmil max  
2 conductors with same cross section, solid min.  
2 conductors with same cross section, solid max.  
26  
16  
0.14 mm²  
0.5 mm²  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 2 / 5  
Feb 17, 2010  
EMKDS 1,5/ 2-5,08 Order No.: 1897694  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1897694  
2 conductors with same cross section, stranded  
min.  
0.14 mm²  
0.5 mm²  
0.25 mm²  
0.34 mm²  
0.5 mm²  
0.5 mm²  
2 conductors with same cross section, stranded  
max.  
2 conductors with same cross section, stranded,  
ferrules without plastic sleeve, min.  
2 conductors with same cross section, stranded,  
ferrules without plastic sleeve, max.  
2 conductors with same cross section, stranded,  
TWIN ferrules with plastic sleeve, min.  
2 conductors with same cross section, stranded,  
TWIN ferrules with plastic sleeve, max.  
Certificates / Approvals  
Certification  
CUL, GOST, UL  
CUL  
Nominal voltage UN  
Nominal current IN  
AWG/kcmil  
300 V  
10 A  
30-14  
UL  
Nominal voltage UN  
Nominal current IN  
AWG/kcmil  
300 V  
10 A  
30-14  
Accessories  
Item  
Designation  
Description  
Marking  
0804293  
SK 5,08/3,8:FORTL.ZAHLEN  
Marker card, printed horizontally, self-adhesive, 12 identical  
decades marked 1-10, 11-20 etc. up to 91-(99)100, sufficient for  
120 terminal blocks  
Tools  
1205053  
SZS 0,6X3,5  
Screwdriver, bladed, matches all screw terminal blocks up to 4.0  
mm² connection cross section, blade: 0.6 x 3.5 mm, without VDE  
approval  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 3 / 5  
Feb 17, 2010  
EMKDS 1,5/ 2-5,08 Order No.: 1897694  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1897694  
Diagrams/Drawings  
Drilling plan/solder pad geometry  
Dimensioned drawing  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 4 / 5  
Feb 17, 2010  
EMKDS 1,5/ 2-5,08 Order No.: 1897694  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1897694  
Address  
PHOENIX CONTACT Inc., USA  
586 Fulling Mill Road  
Middletown, PA 17057,USA  
Phone (800) 888-7388  
Fax (717) 944-1625  
http://www.phoenixcon.com  
© 2010 Phoenix Contact  
Technical modifications reserved;  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 5 / 5  
Feb 17, 2010  

相关型号:

1897704

Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1897717

Barrier Strip Terminal Block, 10A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1897720

Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1897733

Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1897746

Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1897759

Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1897762

Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1897788

Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1897791

Barrier Strip Terminal Block, 8A, 1.5mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1897801

Barrier Strip Terminal Block, 8A, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1897814

Barrier Strip Terminal Block, 8A, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1897827

Barrier Strip Terminal Block, 8A, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX