1969412 [PHOENIX]

Barrier Strip Terminal Block, 76A, 16mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT;
1969412
型号: 1969412
厂家: PHOENIX CONTACT    PHOENIX CONTACT
描述:

Barrier Strip Terminal Block, 76A, 16mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT

端子和端子排
文件: 总5页 (文件大小:162K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Extract from the online  
catalog  
IPC 16/ 6-ST-10,16  
Order No.: 1969412  
The figure shows a 5-pos. version of the product  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1969412  
Plug component, Nominal current: 76 A, Rated voltage (III/2): 1000 V,  
Number of positions: 6, Pitch: 10.16 mm, Color: green, Metal surface:  
Ag  
Product notes  
WEEE/RoHS-compliant since:  
05/05/2003  
Commercial data  
GTIN (EAN)  
4
017918  
943660  
Note  
Made-to-order  
E542  
sales group  
Pack  
http://  
50 pcs.  
www.download.phoenixcontact.com  
Please note that the data given  
here has been taken from the  
online catalog. For comprehensive  
information and data, please refer  
to the user documentation. The  
General Terms and Conditions of  
Use apply to Internet downloads.  
Customs tariff  
Catalog page information  
85366990  
Page 412 (CC-2009)  
Technical data  
Dimensions / positions  
Pitch  
10.16 mm  
50.8 mm  
6
Dimension a  
Number of positions  
Screw thread  
M4  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 1 / 5  
Feb 7, 2011  
IPC 16/ 6-ST-10,16 Order No.: 1969412  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1969412  
Tightening torque, min  
Tightening torque max  
1.7 Nm  
1.8 Nm  
Technical data  
Range of articles  
IPC 16/..-ST  
I
Insulating material group  
Rated surge voltage (III/3)  
Rated surge voltage (III/2)  
Rated surge voltage (II/2)  
Rated voltage (III/2)  
8 kV  
8 kV  
6 kV  
1000 V  
1000 V  
EN-VDE  
76 A  
Rated voltage (II/2)  
Connection in acc. with standard  
Nominal current IN  
Nominal voltage UN  
1000 V  
16 mm²  
76 A  
Nominal cross section  
Maximum load current  
Insulating material  
PA  
Inflammability class acc. to UL 94  
Internal cylindrical gage  
Stripping length  
V0  
A6  
14 mm  
600 V  
55 A  
Nominal voltage, UL/CUL Use Group B  
Nominal current, UL/CUL Use Group B  
Nominal voltage, UL/CUL Use Group C  
Nominal current, UL/CUL Use Group C  
600 V  
55 A  
Connection data  
Conductor cross section solid min.  
Conductor cross section solid max.  
Conductor cross section stranded min.  
Conductor cross section stranded max.  
0.75 mm²  
16 mm²  
0.75 mm²  
16 mm²  
Conductor cross section stranded, with ferrule  
without plastic sleeve min.  
0.5 mm²  
Conductor cross section stranded, with ferrule  
without plastic sleeve max.  
16 mm² Only in connection with CRIMPFOX 16 S  
0.5 mm²  
Conductor cross section stranded, with ferrule  
with plastic sleeve min.  
Conductor cross section stranded, with ferrule  
with plastic sleeve max.  
16 mm² Only in connection with CRIMPFOX 16 S  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 2 / 5  
Feb 7, 2011  
IPC 16/ 6-ST-10,16 Order No.: 1969412  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1969412  
Conductor cross section AWG/kcmil min.  
Conductor cross section AWG/kcmil max  
2 conductors with same cross section, solid min.  
2 conductors with same cross section, solid max.  
18  
6
0.75 mm²  
6 mm²  
0.75 mm²  
2 conductors with same cross section, stranded  
min.  
2 conductors with same cross section, stranded  
max.  
6 mm²  
2 conductors with same cross section, stranded,  
ferrules without plastic sleeve, min.  
0.5 mm²  
4 mm²  
2 conductors with same cross section, stranded,  
ferrules without plastic sleeve, max.  
2 conductors with same cross section, stranded,  
TWIN ferrules with plastic sleeve, min.  
0.5 mm²  
6 mm²  
2 conductors with same cross section, stranded,  
TWIN ferrules with plastic sleeve, max.  
Minimum AWG according to UL/CUL  
Maximum AWG according to UL/CUL  
20  
6
Certificates / Approvals  
Certification  
CUL, UL  
Diagrams/Drawings  
Diagram  
Derating curve for: IPC 16/..-ST-10,16 with  
DFK-IPC 16/..-G-10,16  
Derating curve for: IPC 16/...-ST-10,16  
with IPC 16/...-G-10,16  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 3 / 5  
Feb 7, 2011  
IPC 16/ 6-ST-10,16 Order No.: 1969412  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1969412  
Derating curve for: PC 16/..-ST-10,16 with IPC 16/..-ST-10,16  
Dimensioned drawing  
The illustration shows the 3-pos. version  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 4 / 5  
Feb 7, 2011  
IPC 16/ 6-ST-10,16 Order No.: 1969412  
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1969412  
Address  
PHOENIX CONTACT Inc., USA  
586 Fulling Mill Road  
Middletown, PA 17057,USA  
Phone (800) 888-7388  
Fax (717) 944-1625  
http://www.phoenixcon.com  
© 2011 Phoenix Contact  
Technical modifications reserved;  
PHOENIX CONTACT Inc., USA  
http://www.phoenixcon.com  
Page 5 / 5  
Feb 7, 2011  

相关型号:

1969438

Barrier Strip Terminal Block, 76A, 16mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1969441

Barrier Strip Terminal Block, 76A, 16mm2, 1 Row(s), 1 Deck(s), ROHS COMPLIANT
PHOENIX

1969442-2

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1969442-3

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1969442-4

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1969442-5

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1969442-6

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1969442-7

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1969442-8

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1969442-9

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1969443-2

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

1969443-3

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE