3038600 [PHOENIX]

Modular Terminal Block;
3038600
型号: 3038600
厂家: PHOENIX CONTACT    PHOENIX CONTACT
描述:

Modular Terminal Block

端子和端子排
文件: 总10页 (文件大小:2187K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Four-Conductor Spring Cage Terminal Blocks  
ST ...-QUATTRO  
The double connection of ST...-QUATTRO allows four  
conductors to be connected on one potential. The  
QUATTRO variants can therefore be used as compact  
power distributors.  
The FBS plug-in bridge system allows bridging any  
number of terminal blocks and thus achieves further  
power distribution.  
Phoenix Contact GmbH & Co. KG • 32823 Blomberg, Germany  
Phone +49 52 35 3-00 • Fax +49 52 35 3-4 12 00 • www.phoenixcontact.com  
Local Contact: www.phoenixcontact.com/salesnetwork  
Four-Conductor Spring Cage  
Terminal Block  
ST 1,5-QUATTRO  
(IEC)  
[mm ]  
rigid  
solid  
flexible  
stranded  
I
U
[V]  
2
AWG [A]  
IEC 60 947-7-1  
EN 50 019**  
0.08-1.5  
0.08-1.5  
0.08-1.5  
0.08-1.5  
28-16 17.5* 500  
28-16 17.5* 420  
** EU certificate of design approval no.: KEMA 00ATEX2129U 1  
)
1) For installation notes and the use of accessories for EEx e applications  
see Catalog CLIPLINE.  
* The max. load current must not be exceeded by the total current of all connected  
conductors.  
u P F KEMA  
Technical data  
Pcs.  
Pkt.  
Type  
OrderNo.  
Spring cage terminal block,  
for mounting on 3  
gray terminal width 4.2  
blue terminal width 4.2  
ST 1,5-QUATTRO  
30 31 18 6  
30 31 19 9  
50  
50  
ST 1,5-QUATTRO BU  
(1) End cover  
gray  
gray  
D-ST 2,5-QUATTRO  
DS-ST 2,5  
30 30 51 4  
30 36 60 2  
50  
10  
(2) Segment cover, for covering  
projecting terminal segments  
(3) Insulating stop sleeve, prevents unintentional clamping  
of the insulation in the case of smaller cross sections  
Cross section range:  
0.08-0.2 mm2  
0.25-0.5 mm2  
white  
gray  
ISH 1,5/0,2  
ISH 1,5/0,5  
32 06 13 1  
30 31 03 4  
50  
50  
(4) Plug-in bridge, for  
cross-connections in the  
terminal center  
2-pos.  
3-pos.  
4-pos.  
5-pos.  
10-pos.  
20-pos.  
FBS 2-4  
FBS 3-4  
FBS 4-4  
FBS 5-4  
FBS 10-4  
FBS 20-4  
Imax.: 17.5 A  
30 30 11 6  
30 30 12 9  
30 30 13 2  
30 30 14 5  
30 30 15 8  
30 30 35 2  
50  
50  
50  
50  
10  
10  
17.5 A  
17.5 A  
17.5 A  
17.5 A  
17.5 A  
(5) Partition plate, for  
visual and electrical separation  
of terminal groups, 2 mm thick  
ATP ST-QUATTRO  
PAI 4  
30 30 81 5  
30 30 92 5  
30 30 95 8  
12 04 50 4  
08 08 58 7  
08 05 00 1  
50  
10  
50  
10  
10  
10  
(6) Test adapter, for 4 mm test connector PS  
and 4 mm safety test connectors,  
making contact in the bridge shaft  
(7) Warning cover, for the  
operating shafts of the “mini-spring”  
ST spring cage terminal blocks  
WST 1,5  
(8) Screwdriver, for  
actuating the tension spring  
SZF 0 - 0,4 x 2,5  
ZBF 4:UNPRINTED  
ZB 4:UNPRINTED  
(9) Zack marker sheet, flat, 100-section, for  
labeling the outer marker grooves  
white  
(10) Zack strip, 10-section, for  
labeling in the terminal center  
and on the plug-in bridges  
white  
Dimensions  
Width / length / end cover width  
[mm]  
[mm]  
4.2 / 72 / 2.2  
Height (NS 35/7.5 / NS 35/15)  
36.5 / 44  
Technical data in accordance with IEC/ DIN VDE  
Maximum load current/ cross section  
Rated surge voltage / contamination class  
Surge voltage category / insulation material group  
Capacity connection  
Stranded with ferrule with plastic sleeve  
Stranded with ferrule without plastic sleeve  
Stranded with TWIN ferrule with plastic sleeve  
Stripping length  
[A] / [mm2]  
[kV] / –  
– / –  
17.5 / 1.5  
6 / 3  
III / I  
[mm2]  
[mm2]  
[mm2]  
[mm]  
0.25 - 1.5  
0.25 - 1.5  
0.5  
10  
Internal cylindrical gauge (IEC 60 947-1)  
Insulating material  
A 1  
PA  
Inflammability class in acc. with UL 94  
V0  
Approval data (UL and CSA/CUL)  
Nom. voltage / nom. current / conduc. sizes  
UL: [V] / [A] / AWG  
CSA/CUL: [V] / [A] / AWG  
Phoenix Contact page 2 of 10  
Four-Conductor Spring Cage  
Ground Terminal Block  
ST 1,5-QUATTRO-PE  
(IEC)  
[mm ]  
rigid  
solid  
flexible  
stranded  
2
AWG  
IEC 60 947-7-2  
EN 50 019*  
0.08-1.5  
0.08-1,5  
0.08-1.5  
0.08-1.5  
28-16  
28-16  
* EU certificate of design approval no.: KEMA 00ATEX2129U 1  
)
1) For installation notes and the use of accessories for EEx e applications  
see Catalog CLIPLINE.  
The current carrying capacity of the mounting rails should be observed.  
u P F KEMA  
Technical data  
Pcs.  
Pkt.  
Type  
OrderNo.  
Spring cage ground terminal block,  
for mounting on 3  
green-yellow terminal width 4.2  
ST 1,5-QUATTRO-PE  
D-ST 2,5-QUATTRO  
DS-ST 2,5  
30 31 20 9  
30 30 51 4  
30 36 60 2  
50  
50  
10  
(1) End cover  
gray  
gray  
(2) Segment cover, for covering  
projecting terminal segments  
(3) Insulating stop sleeve, prevents unintentional clamping  
of the insulation in the case of smaller cross sections  
Cross section range:  
0.08-0.2 mm2  
0.25-0.5 mm2  
white  
gray  
ISH 1,5/0,2  
ISH 1,5/0,5  
32 06 13 1  
30 31 03 4  
50  
50  
(4) Screwdriver, for  
actuating the tension spring  
SZF 0 - 0,4 x 2,5  
12 04 50 4  
08 08 58 7  
08 05 00 1  
10  
10  
10  
(5) Zack strip, flat, for  
labeling the outer marker grooves  
white  
white  
ZBF 4:UNPRINTED  
ZB 4:UNPRINTED  
(6) Zack strip, 10-section, for  
labeling in the terminal center  
and on the plug-in bridges  
Dimensions  
Width / length / end cover width  
[mm]  
[mm]  
4.2 / 72 / 2.2  
Height (NS 35/7.5 / NS 35/15)  
36.5 / 44  
Technical data in accordance with IEC/ DIN VDE  
Maximum load current/ cross section  
Rated surge voltage / contamination class  
Surge voltage category / insulation material group  
Capacity connection  
Stranded with ferrule with plastic sleeve  
Stranded with ferrule without plastic sleeve  
Stranded with TWIN ferrule with plastic sleeve  
Stripping length  
[A] / [mm2]  
[kV] / –  
– / –  
6 / 3  
III / I  
[mm2]  
[mm2]  
[mm2]  
[mm]  
0.25 - 1.5  
0.25 - 1.5  
0.5  
10  
Internal cylindrical gauge (IEC 60 947-1)  
Insulating material  
A 1  
PA  
Inflammability class in acc. with UL 94  
V0  
Approval data (UL and CSA/CUL)  
Nom. voltage / nom. current / conduc. sizes  
UL: [V] / [A] / AWG  
CSA/CUL: [V] / [A] / AWG  
Phoenix Contact page 3 of 10  
Four-Conductor Spring Cage  
Terminal Block  
ST 2,5-QUATTRO  
(IEC)  
[mm ]  
rigid  
solid  
flexible  
stranded  
I
U
[V]  
2
AWG [A]  
IEC 60 947-7-1  
EN 50 019**  
0.08-4  
0.08-4  
0.08-2.5  
0.08-2.5  
28-12 28*  
28-12 24/21* 550  
** EU certificate of design approval no.: KEMA 00ATEX2052U 1  
800  
)
1) For installation notes and the use of accessories for EEx e applications  
see Catalog CLIPLINE.  
* The max. load current must not be exceeded by the total current of all connected  
conductors.  
u P F KEMA  
Technical data  
Pcs.  
Pkt.  
Type  
OrderNo.  
Spring cage terminal block,  
for mounting on 3  
gray terminal width 5.2  
blue terminal width 5.2  
ST 2,5-QUATTRO  
30 31 30 6  
30 31 31 9  
50  
50  
ST 2,5-QUATTRO BU  
(1) End cover  
gray  
gray  
D-ST 2,5-QUATTRO  
DS-ST 2,5  
30 30 51 4  
30 36 60 2  
50  
10  
(2) Segment cover, for covering  
projecting terminal segments  
(3) Insulating stop sleeve, prevents unintentional clamping  
of the insulation in the case of smaller cross sections  
Cross section range:  
0.08-0.2 mm2  
0.25-0.5 mm2  
0.75-1 mm2  
white  
gray  
black  
ISH 2,5/0,2  
ISH 2,5/0,5  
ISH 2,5/1  
30 02 84 3  
30 02 85 6  
30 02 86 9  
50  
50  
50  
(4) Plug-in bridge, for  
cross-connections in the  
terminal center  
2-pos.  
3-pos.  
4-pos.  
5-pos.  
10-pos.  
20-pos.  
FBS 2-5  
FBS 3-5  
FBS 4-5  
FBS 5-5  
FBS 10-5  
FBS 20-5  
Imax.: 24 A  
24 A  
30 30 16 1  
30 30 17 4  
30 30 18 7  
30 30 19 0  
30 30 21 3  
30 30 22 6  
50  
50  
50  
50  
10  
10  
24 A  
24 A  
24 A  
24 A  
(5) Partition plate, for  
visual and electrical separation  
of terminal groups, 2 mm thick  
ATP ST-QUATTRO  
PAI 4  
30 30 81 5  
30 30 92 5  
50  
10  
(6) Test adapter, for 4 mm test connector PS  
and 4 mm safety test connectors,  
making contact in the bridge shaft  
1
(7) 2.3 mm test connector ), consisting of  
MPS-RD  
RPS  
02 01 55 3  
02 01 64 7  
10  
10  
metal part and red insulating sleeve  
(8) Reducing plug  
(9) Warning cover, for the  
operating shafts of the “mini-spring”  
ST spring cage terminal blocks  
WST 2,5  
30 30 94 1  
12 04 51 7  
08 08 64 2  
10 50 00 4  
50  
10  
10  
10  
(10) Screwdriver, for  
actuating the tension spring  
SZF 1 - 0,6 x 3,5  
ZBF 5:UNPRINTED  
ZB 5:UNPRINTED  
(11) Zack strip, flat, for  
labeling the outer marker grooves  
white  
white  
(12) Zack strip, 10-section, for  
labeling in the terminal center  
and on the plug-in bridges  
Dimensions  
Width / length / end cover width  
[mm]  
[mm]  
5.2 / 72 / 2.2  
Height (NS 35/7.5 / NS 35/15)  
36.5 / 44  
Technical data in accordance with IEC/ DIN VDE  
Maximum load current/ cross section  
Rated surge voltage / contamination class  
Surge voltage category / insulation material group  
Capacity connection  
Stranded with ferrule with plastic sleeve  
Stranded with ferrule without plastic sleeve  
Stranded with TWIN ferrule with plastic sleeve  
Stripping length  
[A] / [mm2]  
[kV] / –  
– / –  
28 / 4  
8 / 3  
III / I  
[mm2]  
[mm2]  
[mm2]  
[mm]  
0.25 - 2.5  
0.25 - 2.5  
0.5  
10  
Internal cylindrical gauge (IEC 60 947-1)  
Insulating material  
A 3  
PA  
Inflammability class in acc. with UL 94  
V0  
Approval data (UL and CSA/CUL)  
Nom. voltage / nom. current / conduc. sizes  
CSA/CUL: [V] / [A] / AWG  
) Further colors are available on request.  
UL: [V] / [A] / AWG  
600 / 20 / 26 - 12  
600 / 20 / 26 - 12  
1
Phoenix Contact page 4 of 10  
Four-Conductor Spring Cage  
Ground Terminal Block  
ST 2,5-QUATTRO-PE  
(IEC)  
[mm ]  
rigid  
solid  
flexible  
stranded  
2
AWG  
IEC 60 947-7-2  
EN 50 019*  
0.08-4  
0.08-4  
0.08-2.5  
0.08-2.5  
28-12  
28-12  
* EU certificate of design approval no.: KEMA 00ATEX2052U 1  
)
1) For installation notes and the use of accessories for EEx e applications  
see Catalog CLIPLINE.  
The current carrying capacity of the mounting rails should be observed.  
u P F KEMA  
Technical data  
Pcs.  
Pkt.  
Type  
OrderNo.  
Spring cage ground terminal block,  
for mounting on 3  
green-yellow terminal width 5.2  
ST 2,5-QUATTRO-PE  
D-ST 2,5-QUATTRO  
DS-ST 2,5  
30 31 32 2  
30 30 51 4  
30 36 60 2  
50  
50  
10  
(1) End cover  
gray  
gray  
(2) Segment cover, for covering  
projecting terminal segments  
(3) Insulating stop sleeve, prevents unintentional clamping  
of the insulation in the case of smaller cross sections  
Cross section range:  
0.08-0.2 mm2  
0.25-0.5 mm2  
0.75-1 mm2  
white  
gray  
black  
ISH 2,5/0,2  
ISH 2,5/0,5  
ISH 2,5/1  
30 02 84 3  
30 02 85 6  
30 02 86 9  
50  
50  
50  
(4) Screwdriver, for  
actuating the tension spring  
SZF 1 - 0,6 x 3,5  
12 04 51 7  
08 08 64 2  
10 50 00 4  
10  
10  
10  
(5) Zack strip, flat, for  
labeling the outer marker grooves  
white  
white  
ZBF 5:UNPRINTED  
ZB 5:UNPRINTED  
(6) Zack strip, 10-section, for  
labeling in the terminal center  
and on the plug-in bridges  
Dimensions  
Width / length / end cover width  
[mm]  
[mm]  
5.2 / 72 / 2.2  
Height (NS 35/7.5 / NS 35/15)  
36.5 / 44  
Technical data in accordance with IEC/ DIN VDE  
Maximum load current/ cross section  
Rated surge voltage / contamination class  
Surge voltage category / insulation material group  
Capacity connection  
Stranded with ferrule with plastic sleeve  
Stranded with ferrule without plastic sleeve  
Stranded with TWIN ferrule with plastic sleeve  
Stripping length  
[A] / [mm2]  
[kV] / –  
– / –  
8 / 3  
III / I  
[mm2]  
[mm2]  
[mm2]  
[mm]  
0.25 - 2.5  
0.25 - 2.5  
0.5  
10  
Internal cylindrical gauge (IEC 60 947-1)  
Insulating material  
A 3  
PA  
Inflammability class in acc. with UL 94  
V0  
Approval data (UL and CSA/CUL)  
Nom. voltage / nom. current / conduc. sizes  
UL: [V] / [A] / AWG  
– / – / 26 - 12  
– / – / 26 - 12  
CSA/CUL: [V] / [A] / AWG  
Phoenix Contact page 5 of 10  
Four-Conductor Spring Cage  
Terminal Blocks  
ST 4-QUATTRO  
(IEC)  
[mm ]  
rigid  
solid  
flexible  
stranded  
I
U
[V]  
2
AWG [A]  
IEC 60 947-7-1  
EN 50 019**  
0.08-6  
0.08-6  
0.08-4  
0.08-4  
28-10 40*  
28-10 34/25* 550  
** EU certificate of design approval no.: KEMA 00ATEX2129U 1  
800  
)
1) For installation notes and the use of accessories for EEx e applications  
see Catalog CLIPLINE.  
* The max. load current must not be exceeded by the total current of all connected  
conductors.  
u P F KEMA  
Technical data  
Pcs.  
Pkt.  
Type  
OrderNo.  
Spring cage terminal block,  
for mounting on 3  
gray terminal width 6.2  
blue terminal width 6.2  
ST 4-QUATTRO  
30 31 44 5  
30 31 45 8  
50  
50  
ST 4-QUATTRO BU  
(1) End cover  
gray  
gray  
D-ST 4-QUATTRO  
DS-ST 4  
30 30 52 7  
30 36 61 5  
50  
10  
(2) Segment cover, for covering  
projecting terminal segments  
(3) Insulating stop sleeve, prevents unintentional clamping  
of the insulation in the case of smaller cross sections  
Cross section range:  
0.25-0.5 mm2  
0.75-1 mm2  
gray  
black  
ISH 4/0,5  
ISH 4/1  
30 02 88 5  
30 02 89 8  
50  
50  
(4) Plug-in bridge, for  
cross-connections in the  
terminal center  
2-pos.  
3-pos.  
4-pos.  
5-pos.  
10-pos.  
20-pos.  
FBS 2-6  
FBS 3-6  
FBS 4-6  
FBS 5-6  
FBS 10-6  
FBS 20-6  
Imax.: 32 A  
32 A  
30 30 33 6  
30 30 24 2  
30 30 25 5  
30 30 34 9  
30 30 27 1  
30 30 36 5  
50  
50  
50  
50  
10  
10  
32 A  
32 A  
32 A  
32 A  
(5) Partition plate, for  
visual and electrical separation  
of terminal groups, 2 mm thick  
ATP ST-QUATTRO  
PAI 4  
30 30 81 5  
30 30 92 5  
50  
10  
(6) Test adapter, for 4 mm test connector PS  
and 4 mm safety test connectors,  
making contact in the bridge shaft  
1
(7) 2.3 mm test connector ), consisting of  
MPS-RD  
RPS  
02 01 55 3  
02 01 64 7  
10  
10  
metal part and red insulating sleeve  
(8) Reducing plug  
(9) Warning cover, for the  
operating shafts of the “mini-spring”  
ST spring cage terminal blocks  
WST 4  
30 30 95 4  
12 04 51 7  
08 08 71 0  
10 51 00 3  
50  
10  
10  
10  
(10) Screwdriver, for  
actuating the tension spring  
SZF 1 - 0,6 x 3,5  
ZBF 6:UNPRINTED  
ZB 6:UNPRINTED  
(11) Zack strip, flat, for  
labeling the outer marker grooves  
white  
white  
(12) Zack strip, 10-section, for  
labeling in the terminal center  
and on the plug-in bridges  
Dimensions  
Width / length / end cover width  
[mm]  
[mm]  
6.2 / 87 / 2.2  
Height (NS 35/7.5 / NS 35/15)  
36.5 / 44  
Technical data in accordance with IEC/ DIN VDE  
Maximum load current/ cross section  
Rated surge voltage / contamination class  
Surge voltage category / insulation material group  
Capacity connection  
Stranded with ferrule with plastic sleeve  
Stranded with ferrule without plastic sleeve  
Stranded with TWIN ferrule with plastic sleeve  
Stripping length  
[A] / [mm2]  
[kV] / –  
– / –  
40 / 6  
8 / 3  
III / I  
[mm2]  
[mm2]  
[mm2]  
[mm]  
0.25 - 4  
0.25 - 4  
0.5 - 1  
10  
Internal cylindrical gauge (IEC 60 947-1)  
Insulating material  
A 4  
PA  
Inflammability class in acc. with UL 94  
V0  
Approval data (UL and CSA/CUL)  
Nom. voltage / nom. current / conduc. sizes  
CSA/CUL: [V] / [A] / AWG  
) Further colors are available on request.  
UL: [V] / [A] / AWG  
1
Phoenix Contact page 6 of 10  
Four-Conductor Spring Cage  
Ground Terminal Block  
ST 4-QUATTRO-PE  
(IEC)  
[mm ]  
rigid  
solid  
flexible  
stranded  
2
AWG  
IEC 60 947-7-2  
EN 50 019*  
0.08-6  
0,08-6  
0.08-4  
0,08-4  
28-10  
28-10  
* EU certificate of design approval no.: KEMA 00ATEX2129U 1  
)
1) For installation notes and the use of accessories for EEx e applications  
see Catalog CLIPLINE.  
The current carrying capacity of the mounting rails should be observed.  
u P F KEMA  
Technical data  
Pcs.  
Pkt.  
Type  
OrderNo.  
Spring cage ground terminal block,  
for mounting on 3  
green-yellow terminal width 6.2  
ST 4-QUATTRO-PE  
D-ST 4-QUATTRO  
DS-ST 4  
30 31 46 1  
30 30 52 7  
30 36 61 5  
50  
50  
10  
(1) End cover  
gray  
gray  
(2) Segment cover, for covering  
projecting terminal segments  
(3) Insulating stop sleeve, prevents unintentional clamping  
of the insulation in the case of smaller cross sections  
Cross section range:  
0.25-0.5 mm2  
0.75-1 mm2  
gray  
black  
ISH 4/0,5  
ISH 4/1  
30 02 88 5  
30 02 89 8  
50  
50  
(4) Screwdriver, for  
actuating the tension spring  
SZF 1 - 0,6 x 3,5  
12 04 51 7  
08 08 71 0  
10 51 00 3  
10  
10  
10  
(5) Zack strip, flat, for  
labeling the outer marker grooves  
white  
white  
ZBF 6:UNPRINTED  
ZB 6:UNPRINTED  
(6) Zack strip, 10-section, for  
labeling in the terminal center  
and on the plug-in bridges  
Dimensions  
Width / length / end cover width  
[mm]  
[mm]  
6.2 / 87 / 2.2  
Height (NS 35/7.5 / NS 35/15)  
36.5 / 44  
Technical data in accordance with IEC/ DIN VDE  
Maximum load current/ cross section  
Rated surge voltage / contamination class  
Surge voltage category / insulation material group  
Capacity connection  
Stranded with ferrule with plastic sleeve  
Stranded with ferrule without plastic sleeve  
Stranded with TWIN ferrule with plastic sleeve  
Stripping length  
[A] / [mm2]  
[kV] / –  
– / –  
8 / 3  
III / I  
[mm2]  
[mm2]  
[mm2]  
[mm]  
0.25 - 4  
0.25 - 4  
0.5 - 1  
10  
Internal cylindrical gauge (IEC 60 947-1)  
Insulating material  
A 3  
PA  
Inflammability class in acc. with UL 94  
V0  
Approval data (UL and CSA/CUL)  
Nom. voltage / nom. current / conduc. sizes  
UL: [V] / [A] / AWG  
CSA/CUL: [V] / [A] / AWG  
Phoenix Contact page 7 of 10  
Four-Conductor Spring Cage  
Terminal Block  
ST 1,5-QUATTRO-U  
(IEC)  
[mm ]  
rigid  
solid  
flexible  
stranded  
I
U
[V]  
2
AWG [A]  
IEC 60 947-7-1  
0.08-1.5  
0.08-1.5  
28-16 17.5* 500  
* The max. load current must not be exceeded by the total current of all connected  
conductors.  
Technical data  
Pcs.  
Pkt.  
Type  
OrderNo.  
Spring cage terminal block,  
for mounting on 3  
gray terminal width 4.2  
ST 1,5-QUATTRO-U  
D-ST 2,5-QUATTRO  
DS-ST 2,5  
30 38 60 0  
30 30 51 4  
30 36 60 2  
50  
50  
10  
(1) End cover  
gray  
gray  
(2) Segment cover, for covering  
projecting terminal segments  
(3) Insulating stop sleeve, prevents unintentional clamping  
of the insulation in the case of smaller cross sections  
Cross section range:  
0.08-0.2 mm2  
0.25-0.5 mm2  
white  
gray  
ISH 2,5/0,2  
ISH 2,5/0,5  
30 02 84 3  
30 02 85 6  
50  
50  
(4) Plug-in bridge, for  
cross-connections in the  
terminal center  
2-pos.  
3-pos.  
4-pos.  
5-pos.  
10-pos.  
20-pos.  
FBS 2-4  
FBS 3-4  
FBS 4-4  
FBS 5-4  
FBS 10-4  
FBS 20-4  
Imax.: 17,5 A  
30 30 11 6  
30 30 12 9  
30 30 13 2  
30 30 14 5  
30 30 15 8  
30 30 35 2  
50  
50  
50  
50  
10  
10  
17,5 A  
17,5 A  
17,5 A  
17,5 A  
17,5 A  
(5) Partition plate, for  
visual and electrical separation  
of terminal groups, 2 mm thick  
ATP ST-QUATTRO  
PAI 4  
30 30 81 5  
30 30 92 5  
50  
10  
(6) Test adapter, for 4 mm test connector PS  
and 4 mm safety test connectors,  
making contact in the bridge shaft  
1
(7) 2.3 mm test connector ), consisting of  
MPS-RD  
RPS  
02 01 55 3  
02 01 64 7  
10  
10  
metal part and red insulating sleeve  
(8) Reducing plug  
(9) Warning cover, for the  
operating shafts of the “mini-spring”  
ST spring cage terminal blocks  
WST 1,5  
30 30 95 8  
12 04 50 4  
08 08 58 7  
08 05 00 1  
50  
10  
10  
10  
(10) Screwdriver, for  
actuating the tension spring  
SZF 1 - 0,4 x 2,5  
ZBF 4:UNPRINTED  
ZB 4:UNPRINTED  
(11) Zack strip, flat, for  
labeling the outer marker grooves  
white  
white  
(12) Zack strip, 10-section, for  
labeling in the terminal center  
and on the plug-in bridges  
Dimensions  
Width / length / end cover width  
[mm]  
[mm]  
4.2 / 72 / 2.2  
Height (NS 35/7.5 / NS 35/15)  
36.5 / 44  
Technical data in accordance with IEC/ DIN VDE  
Maximum load current/ cross section  
Rated surge voltage / contamination class  
Surge voltage category / insulation material group  
Capacity connection  
Stranded with ferrule with plastic sleeve  
Stranded with ferrule without plastic sleeve  
Stranded with TWIN ferrule with plastic sleeve  
Stripping length  
[A] / [mm2]  
[kV] / –  
– / –  
17.5 / 1.5  
6 / 3  
III / I  
[mm2]  
[mm2]  
[mm2]  
[mm]  
0.25 - 2.5  
0.25 - 2.5  
0.5  
10  
Internal cylindrical gauge (IEC 60 947-1)  
Insulating material  
A 1  
PA  
Inflammability class in acc. with UL 94  
V0  
Approval data (UL and CSA/CUL)  
Nom. voltage / nom. current / conduc. sizes  
CSA/CUL: [V] / [A] / AWG  
) Further colors are available on request.  
UL: [V] / [A] / AWG  
1
Phoenix Contact page 8 of 10  
Four-Conductor Spring Cage  
Terminal Block  
ST 2,5-QUATTRO-U  
(IEC)  
[mm ]  
rigid  
solid  
flexible  
stranded  
I
U
[V]  
2
AWG [A]  
IEC 60 947-7-1  
0.08-4  
0.08-2.5  
28-12 28*  
800  
* The max. load current must not be exceeded by the total current of all connected  
conductors.  
Technical data  
Pcs.  
Pkt.  
Type  
OrderNo.  
30 31 63 6  
Spring cage terminal block,  
for mounting on 3  
gray terminal width 5.2  
ST 2,5-QUATTRO-U  
50  
(1) End cover  
gray  
gray  
D-ST 2,5-QUATTRO  
DS-ST 2,5  
30 30 51 4  
30 36 60 2  
50  
10  
(2) Segment cover, for covering  
projecting terminal segments  
(3) Insulating stop sleeve, prevents unintentional clamping  
of the insulation in the case of smaller cross sections  
Cross section range:  
0.08-0.2 mm2  
0.25-0.5 mm2  
0.75-1 mm2  
white  
gray  
black  
ISH 2,5/0,2  
ISH 2,5/0,5  
ISH 2,5/1  
30 02 84 3  
30 02 85 6  
30 02 86 9  
50  
50  
50  
(4) Plug-in bridge, for  
cross-connections in the  
terminal center  
2-pos.  
3-pos.  
4-pos.  
5-pos.  
10-pos.  
20-pos.  
FBS 2-5  
FBS 3-5  
FBS 4-5  
FBS 5-5  
FBS 10-5  
FBS 20-5  
Imax.: 24 A  
24 A  
30 30 16 1  
30 30 17 4  
30 30 18 7  
30 30 19 0  
30 30 21 3  
30 30 22 6  
50  
50  
50  
50  
10  
10  
24 A  
24 A  
24 A  
24 A  
(5) Partition plate, for  
visual and electrical separation  
of terminal groups, 2 mm thick  
ATP ST-QUATTRO  
PAI 4  
30 30 81 5  
30 30 92 5  
50  
10  
(6) Test adapter, for 4 mm test connector PS  
and 4 mm safety test connectors,  
making contact in the bridge shaft  
1
(7) 2.3 mm test connector ), consisting of  
MPS-RD  
RPS  
02 01 55 3  
02 01 64 7  
10  
10  
metal part and red insulating sleeve  
(8) Reducing plug  
(9) Warning cover, for the  
operating shafts of the “mini-spring”  
ST spring cage terminal blocks  
WST 2,5  
30 30 94 1  
12 04 51 7  
08 08 64 2  
10 50 00 4  
50  
10  
10  
10  
(10) Screwdriver, for  
actuating the tension spring  
SZF 1 - 0,6 x 3,5  
ZBF 5:UNPRINTED  
ZB 5:UNPRINTED  
(11) Zack strip, flat, for  
labeling the outer marker grooves  
white  
white  
(12) Zack strip, 10-section, for  
labeling in the terminal center  
and on the plug-in bridges  
Dimensions  
Width / length / end cover width  
[mm]  
[mm]  
5.2 / 72 / 2.2  
Height (NS 35/7.5 / NS 35/15)  
36.5 / 44  
Technical data in accordance with IEC/ DIN VDE  
Maximum load current/ cross section  
Rated surge voltage / contamination class  
Surge voltage category / insulation material group  
Capacity connection  
Stranded with ferrule with plastic sleeve  
Stranded with ferrule without plastic sleeve  
Stranded with TWIN ferrule with plastic sleeve  
Stripping length  
[A] / [mm2]  
[kV] / –  
– / –  
28 / 4  
8 / 3  
III / I  
[mm2]  
[mm2]  
[mm2]  
[mm]  
0.25 - 2.5  
0.25 - 2.5  
0.5  
10  
Internal cylindrical gauge (IEC 60 947-1)  
Insulating material  
A 3  
PA  
Inflammability class in acc. with UL 94  
V0  
Approval data (UL and CSA/CUL)  
Nom. voltage / nom. current / conduc. sizes  
CSA/CUL: [V] / [A] / AWG  
) Further colors are available on request.  
UL: [V] / [A] / AWG  
1
Phoenix Contact page 9 of 10  
Four-Conductor Spring Cage  
Terminal Block  
ST 4-QUATTRO-U  
(IEC)  
[mm ]  
rigid  
solid  
flexible  
stranded  
I
U
[V]  
2
AWG [A]  
IEC 60 947-7-1  
0.08-4  
0.08-2.5  
28-12 28*  
800  
* The max. load current must not be exceeded by the total current of all connected  
conductors.  
Technical data  
Pcs.  
Pkt.  
Type  
OrderNo.  
Spring cage terminal block,  
for mounting on 3  
gray terminal width 6.2  
ST 4-QUATTRO-U  
D-ST 4-QUATTRO  
DS-ST 4  
30 38 63 9  
30 30 52 7  
30 36 61 5  
50  
50  
10  
(1) End cover  
gray  
gray  
(2) Segment cover, for covering  
projecting terminal segments  
(3) Insulating stop sleeve, prevents unintentional clamping  
of the insulation in the case of smaller cross sections  
Cross section range:  
0.25-0.5 mm2  
0.75-1 mm2  
gray  
black  
ISH 4/0,5  
ISH 4/1  
30 02 88 5  
30 02 89 8  
50  
50  
(4) Plug-in bridge, for  
cross-connections in the  
terminal center  
2-pos.  
3-pos.  
4-pos.  
5-pos.  
10-pos.  
20-pos.  
FBS 2-6  
FBS 3-6  
FBS 4-6  
FBS 5-6  
FBS 10-6  
FBS 20-6  
Imax.: 32 A  
32 A  
30 30 33 6  
30 30 24 2  
30 30 25 5  
30 30 34 9  
30 30 27 1  
30 30 36 5  
50  
50  
50  
50  
10  
10  
32 A  
32 A  
32 A  
32 A  
(5) Partition plate, for  
visual and electrical separation  
of terminal groups, 2 mm thick  
ATP ST-QUATTRO  
PAI 4  
30 30 81 5  
30 30 92 5  
50  
10  
(6) Test adapter, for 4 mm test connector PS  
and 4 mm safety test connectors,  
making contact in the bridge shaft  
1
(7) 2.3 mm test connector ), consisting of  
MPS-RD  
RPS  
02 01 55 3  
02 01 64 7  
10  
10  
metal part and red insulating sleeve  
(8) Reducing plug  
(9) Warning cover, for the  
operating shafts of the “mini-spring”  
ST spring cage terminal blocks  
WST 4  
30 30 95 4  
12 04 51 7  
08 08 71 0  
10 51 00 3  
50  
10  
10  
10  
(10) Screwdriver, for  
actuating the tension spring  
SZF 1 - 0,6 x 3,5  
ZBF 6:UNPRINTED  
ZB 6:UNPRINTED  
(11) Zack strip, flat, for  
labeling the outer marker grooves  
white  
white  
(12) Zack strip, 10-section, for  
labeling in the terminal center  
and on the plug-in bridges  
Dimensions  
Width / length / end cover width  
[mm]  
[mm]  
6.2 / 87 / 2.2  
Height (NS 35/7.5 / NS 35/15)  
36.5 / 44  
Technical data in accordance with IEC/ DIN VDE  
Maximum load current/ cross section  
Rated surge voltage / contamination class  
Surge voltage category / insulation material group  
Capacity connection  
Stranded with ferrule with plastic sleeve  
Stranded with ferrule without plastic sleeve  
Stranded with TWIN ferrule with plastic sleeve  
Stripping length  
[A] / [mm2]  
[kV] / –  
– / –  
40 / 6  
8 / 3  
III / I  
[mm2]  
[mm2]  
[mm2]  
[mm]  
0.25 - 4  
0.25 - 4  
0.5 - 1  
10  
Internal cylindrical gauge (IEC 60 947-1)  
Insulating material  
A 4  
PA  
Inflammability class in acc. with UL 94  
V0  
Approval data (UL and CSA/CUL)  
Nom. voltage / nom. current / conduc. sizes  
CSA/CUL: [V] / [A] / AWG  
) Further colors are available on request.  
UL: [V] / [A] / AWG  
1
Phoenix Contact page 10 of 10  

相关型号:

3038613

THERMOMARK LINE
PHOENIX

3038642

Modular Terminal Block
PHOENIX

3038655

Connector Accessory
PHOENIX

3038723

Terminal Block Accessory, Plug Item,
PHOENIX

3038736

Terminal Block Accessory
PHOENIX

3038752

Modular Terminal Block
PHOENIX

3038875

Modular Terminal Block, 20A, 6mm2, 1 Row(s), 1 Deck(s),
PHOENIX

3038930

Terminal Block Accessory, Jumper Item,
PHOENIX

3038943

Terminal Block Accessory
PHOENIX

3038956

Terminal Block Accessory
PHOENIX

3038969

Terminal Block Accessory, Jumper Item, ROHS COMPLIANT
PHOENIX

3039007

Terminal Block Accessory, Jumper Item,
PHOENIX