3206542 [PHOENIX]
Modular Terminal Block;型号: | 3206542 |
厂家: | PHOENIX CONTACT |
描述: | Modular Terminal Block 端子和端子排 |
文件: | 总6页 (文件大小:80K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
https://www.phoenixcontact.com/pi/products/3206542
Feed-through terminal block - QTCU 2,5 BU - 3206542
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Feed-through terminal block, connection method: Quick connection, Screw connection, cross section: 0.5
mm² - 2.5 mm², AWG: 20 - 14, width: 6.2 mm, color: blue, mounting: NS 35/7,5, NS 35/15
Why buy this product
The hybrid versions combine the advantages of the different connection technologies
The time-saving QUICKON fast connection is used on the control cabinet side
The screw connection is used on the connection side
Key Commercial Data
Packing unit
50 STK
GTIN
GTIN
4046356057721
Technical data
General
Number of levels
1
Number of connections
Nominal cross section
Color
2
2.5 mm²
blue
Insulating material
PA
Flammability rating according to UL 94
Rated surge voltage
V0
8 kV
Degree of pollution
3
Overvoltage category
III
Insulating material group
Maximum power dissipation for nominal condition
Ambient temperature (actuation)
Connection method
I
0.77 W
-10 °C ... 90 °C
Quick connection
02/09/2018 Page 1 / 6
https://www.phoenixcontact.com/pi/products/3206542
Feed-through terminal block - QTCU 2,5 BU - 3206542
Technical data
General
Connection in acc. with standard
Maximum load current
IEC 60947-7-1
24 A (with a 2.5 mm² conductor cross section)
Nominal current IN
24 A
Nominal voltage UN
800 V
Connection method
Screw connection
Connection in acc. with standard
Maximum load current
IEC 60947-7-1
24 A (with 2.5 mm² conductor connection cross section)
Nominal current IN
24 A
Nominal voltage UN
800 V
Open side panel
Yes
Shock protection test specification
Back of the hand protection
Finger protection
DIN EN 50274 (VDE 0660-514):2002-11
guaranteed
guaranteed
Test passed
9.8 kV
Result of surge voltage test
Surge voltage test setpoint
Result of power-frequency withstand voltage test
Power frequency withstand voltage setpoint
Test passed
2 kV
Result of the test for mechanical stability of terminal points (5 x
conductor connection)
Test passed
Result of bending test
Test passed
10 rpm
Bending test rotation speed
Bending test turns
135
Bending test conductor cross section/weight
0.5 mm² / 0.3 kg
2.5 mm² / 0.7 kg
0.14 mm² / 0.2 kg
4 mm² / 0.9 kg
6 mm2 / 1.4 kg
Test passed
0.5 mm²
20 N
Tensile test result
Conductor cross section tensile test
Tractive force setpoint
Conductor cross section tensile test
Tractive force setpoint
2.5 mm²
50 N
Conductor cross section tensile test
Tractive force setpoint
4 mm²
60 N
Result of tight fit on support
Tight fit on carrier
Test passed
NS 35
Setpoint
1 N
Result of voltage-drop test
Requirements, voltage drop
Result of temperature-rise test
Short circuit stability result
Test passed
≤ 3.2 mV
Test passed
Test passed
02/09/2018 Page 2 / 6
https://www.phoenixcontact.com/pi/products/3206542
Feed-through terminal block - QTCU 2,5 BU - 3206542
Technical data
General
Conductor cross section short circuit testing
Short-time current
2.5 mm²
0.3 kA
Result of aging test
Test passed
192
Ageing test for screwless modular terminal block temperature cycles
Result of thermal test
Test passed
30 s
Proof of thermal characteristics (needle flame) effective duration
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE
0304-21))
130 °C
Static insulating material application in cold
Behavior in fire for rail vehicles (DIN 5510-2)
Flame test method (DIN EN 60695-11-10)
-60 °C
Test passed
V0
Oxygen index (DIN EN ISO 4589-2)
>32 %
NF F16-101, NF F10-102 Class I
2
NF F16-101, NF F10-102 Class F
2
Surface flammability NFPA 130 (ASTM E 162)
Specific optical density of smoke NFPA 130 (ASTM E 662)
Smoke gas toxicity NFPA 130 (SMP 800C)
Calorimetric heat release NFPA 130 (ASTM E 1354)
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
passed
passed
passed
28 MJ/kg
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
Dimensions
Width
6.2 mm
Length
62.6 mm
42.8 mm
50.3 mm
2.2 mm
Height NS 35/7,5
Height NS 35/15
End cover width
Connection data
Connection method
Quick connection
IEC 60947-7-1
3.8 mm
0.5 mm²
2.5 mm²
20
Connection in acc. with standard
Max. wire diameter incl. insulation
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG min.
Conductor cross section AWG max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Min. AWG conductor cross section, flexible
14
0.5 mm²
2.5 mm²
20
02/09/2018 Page 3 / 6
https://www.phoenixcontact.com/pi/products/3206542
Feed-through terminal block - QTCU 2,5 BU - 3206542
Technical data
Connection data
Max. AWG conductor cross section, flexible
Connection in acc. with standard
Test certificate name
14
IEC/EN 60079-7
KEMA 05ATEX2148 U
PVC / PE
Screw connection
IEC 60947-7-1
M3
Material wire insulation
Connection method
Connection in acc. with standard
Screw thread
Tightening torque, min
0.6 Nm
Tightening torque max
0.8 Nm
Stripping length
9 mm
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG min.
Conductor cross section AWG max.
Conductor cross section flexible min.
Conductor cross section flexible max.
0.14 mm²
6 mm²
26
10
0.14 mm²
4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve max.
2 conductors with same cross section, solid min.
0.14 mm²
4 mm²
0.14 mm²
1.5 mm²
0.14 mm²
1.5 mm²
2 conductors with same cross section, solid max.
2 conductors with same cross section, stranded min.
2 conductors with same cross section, stranded max.
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, min.
0.14 mm²
1.5 mm²
0.5 mm²
2.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, max.
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, min.
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, max.
Standards and Regulations
Connection in acc. with standard
CSA
IEC 60947-7-1
IEC 60947-7-1
Flammability rating according to UL 94
V0
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
02/09/2018 Page 4 / 6
https://www.phoenixcontact.com/pi/products/3206542
Feed-through terminal block - QTCU 2,5 BU - 3206542
Technical data
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Circuit diagram
Approvals
Approvals
Approvals
CSA / UL Recognized / cUL Recognized / EAC / LR / DNV GL / cULus Recognized
Ex Approvals
IECEx / ATEX / EAC Ex
Approval details
CSA
http://www.csagroup.org/services-industries/product-listing/
13631
B
C
mm²/AWG/kcmil
20-14
15 A
600 V
20-14
15 A
600 V
Nominal current IN
Nominal voltage UN
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
C
FILE E 60425
B
mm²/AWG/kcmil
20-14
15 A
20-14
15 A
Nominal current IN
Nominal voltage UN
600 V
600 V
02/09/2018 Page 5 / 6
https://www.phoenixcontact.com/pi/products/3206542
Feed-through terminal block - QTCU 2,5 BU - 3206542
Approvals
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
C
FILE E 60425
B
mm²/AWG/kcmil
20-14
15 A
20-14
15 A
Nominal current IN
Nominal voltage UN
600 V
600 V
EAC
7500651.22.01.00246
LR
http://www.lr.org/en
15/20023
DNV GL
http://exchange.dnv.com/tari/
TAE000014H
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com
02/09/2018 Page 6 / 6
©2020 ICPDF网 联系我们和版权申明