SAC-5P-M12MS/2,0-920/M12FS [PHOENIX]
Cable Assembly;![SAC-5P-M12MS/2,0-920/M12FS](http://pdffile.icpdf.com/pdf2/p00241/img/icpdf/SAC-5P-M12MS_1460247_icpdf.jpg)
型号: | SAC-5P-M12MS/2,0-920/M12FS |
厂家: | ![]() |
描述: | Cable Assembly 连接器 连接器支架 |
文件: | 总5页 (文件大小:111K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
https://www.phoenixcontact.com/us/products/1507557
Bus system cable - SAC-5P-M12MS/ 2,0-920/M12FS - 1507557
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, violet RAL 4001, shielded, Plug
straight M12, A-coded, on Socket straight M12, A-coded, Cable length: 2 m
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
155.0 g
85444290
Poland
Technical data
Dimensions
Length of cable
2 m
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 90 °C (Plug / socket)
IP65
IP67
General
Rated current at 40°C
Rated voltage
4 A
60 V
Number of positions
Insulation resistance
Coding
5
≥ 100 MΩ
A - standard
CANopen®
Signal type/category
DeviceNet™
Status display
No
II
Overvoltage category
05/19/2016 Page 1 / 5
https://www.phoenixcontact.com/us/products/1507557
Bus system cable - SAC-5P-M12MS/ 2,0-920/M12FS - 1507557
Technical data
General
Degree of pollution
Insertion/withdrawal cycles
Torque
3
≥ 100
0.4 Nm (M12 connector)
Material
Flammability rating according to UL 94
Contact material
HB
CuSn
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Sealing material
Pin assignment
Position = wire color (signal) = position (optional)
1 (Plug) = SR (shield) = 1 (Socket)
2 (Plug) = RD (V+) = 2 (Socket)
3 (Plug) = BK (V-) = 3 (Socket)
4 (Plug) = WH (CAN_H) = 4 (Socket)
5 (Plug) = BU (CAN_L) = 5 (Socket)
Standards and Regulations
Flammability rating according to UL 94
HB
Cable
Cable type
CAN Bus/DeviceNet
920
Cable type (abbreviation)
UL AWM style
21198 (80°C/300 V)
2xAWG24/19+2xAWG22/19
2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
24
Cable structure
Conductor cross section
AWG signal line
AWG power supply
22
Conductor structure signal line
Conductor structure, voltage supply
Core diameter including insulation
19x 0.13 mm
19x 0.15 mm
1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
Red-black, blue-white
2 cores to the pair
Wire colors
Twisted pairs
05/19/2016 Page 2 / 5
https://www.phoenixcontact.com/us/products/1507557
Bus system cable - SAC-5P-M12MS/ 2,0-920/M12FS - 1507557
Technical data
Cable
Type of pair shielding
Overall twist
Plastic-coated aluminum foil, aluminum side outside
2 pairs around a drain wire in the center to the core
Tinned copper braided shield
80 %
Shielding
Optical shield covering
External sheath, color
External cable diameter D
Minimum bending radius, flexible installation
Number of bending cycles
Bending radius
violet RAL 4001
6.7 mm ±0,3 mm
10 x D
5000000
70 mm
Traversing path
4.5 m
Traversing rate
3 m/s
Acceleration
3 m/s²
Outer sheath, material
Material conductor insulation
PUR
Foamed PE (Data cable)
PE (Power supply)
Conductor material
Insulation resistance
Tin-plated Cu litz wires
≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
≤ 90.9 Ω/km (Data cable)
≤ 57.4 Ω/km (Power supply)
nom. 40 pF/m (Data cable)
120 Ω ±10 % (with 1 MHz)
≥ 0.0229 dB/m (with 1 MHz)
≤ 300 V (Peak value, not for high-power applications)
2000 V (50 Hz, 1 min.)
2000 V (50 Hz, 1 min.)
UL 1581, Sec. 1060 (FT-1)
IEC 60332-1
Conductor resistance
Cable capacity
Wave impedance
Wave attenuation
Nominal voltage, cable
Test voltage Core/Core
Test voltage Core/Shield
Flame resistance
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
in accordance with DIN VDE 0472 part 815
According to IEC 60754-1
Low adhesion
Halogen-free
Other resistance
Ambient temperature (operation)
-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)
≤ 70 °C (cable, drag chain applications)
05/19/2016 Page 3 / 5
https://www.phoenixcontact.com/us/products/1507557
Bus system cable - SAC-5P-M12MS/ 2,0-920/M12FS - 1507557
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
eCl@ss 9.0
27060306
27060306
27061801
27061801
27061801
27061801
27279218
27060311
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC000830
EC001855
EC001855
EC001855
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
31251501
31251501
31251501
31251501
31251501
UNSPSC 12.01
UNSPSC 13.2
Approvals
Approvals
Approvals
EAC
Ex Approvals
Approvals submitted
Approval details
05/19/2016 Page 4 / 5
https://www.phoenixcontact.com/us/products/1507557
Bus system cable - SAC-5P-M12MS/ 2,0-920/M12FS - 1507557
Approvals
EAC
Drawings
Schematic diagram
Schematic diagram
4
3
3
4
5
5
1
2
2
1
Pin assignment M12 male connector, 5-pos., A-coded, male side
Cable cross section
Pin assignment M12 socket, 5-pos., A-coded, socket side view
Circuit diagram
1
2
3
4
5
1 --- (Drain)
2 RD (V+)
3 BK (V-)
4 WH (CAN_H)
5 BU (CAN_L)
CAN Bus/DeviceNet [920]
Contact assignment of the M12 connector and the M12 socket
Dimensional drawing
Dimensional drawing
47,3
44,5
Plug, M12 x 1, straight, shielded
M12 x 1 socket, straight, shielded