BLP30 AC-DC Series Data Sheet
30 Watts
Features
•
•
RoHS compliant for all six substances
2” x 4” footprint
•
•
•
•
•
•
•
•
•
•
Component height less than 1”
25 W rating with natural convection cooling
30 W rating with 10 CFM airflow
Compliance to EMI Class B
Universal AC input
Short-circuit protection
Overvoltage protection
Applications
CE marked to Low Voltage Directive (Pending)
Compliance to EN61000-4-2/-3/-4/-5/-6/-8/-11
Two-year warranty
•
•
•
•
•
•
•
Datacom (hubs, routers)
POS terminals
Industrial
Cable modems
External disk storage
Medical instrumentation
Computers
Description
The BLP30 Series’ economical and compact construction provides single or three-output AC to DC power
conversion to meet the requirements of most commercial and industrial applications.
Single-Output Model Selection
Model
Nominal
Output Voltage
Min-Max Output
Current (Amps),
Convection
Min-Max Output
Current (Amps),
Forced Air 1
Peak Output
Current
Total
Ripple &
Noise
Regulation
(Amps) 2
pk-pk % 4
(VDC)
(%) 3
± 2
BLP30-1005G
BLP30-1012G
BLP30-1024G
5V
0 – 5
0 – 6
0 – 2.5
0 – 1.25
7.2
3.0
1.5
1
1
12V
24V
0 – 2.1
0 – 1.0
± 2
0.6
± 2
Triple-Output Model Selection
Model
Nominal
Output Voltage
Min-Max Output
Current (Amps),
Convection
Min-Max Output
Current (Amps),
Forced Air 1
Peak Output
Current
Total
Ripple &
Noise
Regulation
(Amps) 2
pk-pk % 4
(VDC)
+5V
(%) 3
±2
0.2 – 2.5
0.1 – 1.2
0.0 – 0.3
0.2 – 3.5
0.1 – 2.0
0.0 – 0.5
5
3
1
1%
1%
1%
BLP30-3000G
+12V
-12V
±5
±5
1
10 CFM or 260 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm) cross-sectional area with
power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC input to the DC output.
Peak current duration for less than 30 seconds with a max duty cycle of 10%.
At 25 °C ambient including voltage set point tolerance, line, and load regulation
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, measured with a twisted pair differentially
across a 10 µF E-cap and a 0.1 µF ceramic cap in parallel. The point of measurement is within 1 cm of the output connection.
2
3
4
JUL 05, 2006 revised to DEC 05, 2006
Page 1 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
ELECTRICAL SPECIFICATIONS
Input Specifications
Parameter
Conditions/Description
Min.
Nom.
Max.
Units
Input Voltage - AC
Input Voltage - DC
Input Frequency
Input Current
Single-phase continuous input range
90
100 - 250
264
VAC
127
47
160/325
50 - 60
0.75
375
63
VDC
Hz
AC Input
At 90 VAC input., 30W
A rms
Inrush Surge Current
Internally limited. 115 VAC, Max Power, 25 °C
Internally limited. 230 VAC, Max Power, 25 °C
16
32
A pk
A pk
Input fuse
Non-user serviceable internally located AC
input line fuse is provided.
Efficiency
At maximum output power.
70
60
75
%
Switching Frequency
69
kHz
Output Specifications
Parameter
Conditions/Description
Min.
Nom.
Max.
Units
Output power
With convection cooling. See Model Selection.
With forced-air cooling. See Model Selection.
25
30
Watts
Load transient
Turn on Delay
Rise Time
Vo1, Vo2, or Vo3 deviation due to a 50 to 100%
load change at a rate of 1A/µs.
±5
1.5
20
%
Sec
ms
Ms
V
Time required for outputs to be within regulation
after initial application of AC input.
Time required for output voltage to rise from
10% to 90%.
Hold-up Time
At 30W, 115 VAC, 60 Hz.
20
Overvoltage Protection Main output.
5V:
12V:
24V:
5.6
14.0
29.0
6.9
16.7
34.2
Short-circuit Protection Fully-protected against output short circuit.
Overshoot
Overshoot
Single-output models.
Triple-output models.
2
5
%
%
JUL 05, 2006 revised to DEC 05, 2006
Page 2 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Regulatory & Safety Approvals
Parameter
Conditions/Description
Min.
Nom.
Max.
Units
UL60950-1
All models are approved.
All models are approved.
CSA-C22.2,
No. 60950-1-03
EN 60950-1
All models are approved.
/IEC 60950-1
CE Mark for LVD
CB Approval
All models are approved.
Completed.
Ground Continuity
At 12 VDC.
30
A
Dielectric Withstand
Voltage
Input-to-Ground (Basic)
2121
4242
VDC
.
Input-to-Output (Reinforced). The primary to
secondary test is not performed on completed
assemblies.
VDC
Output-to-Ground (Functional).
500
VDC
Electromagnetic
Interference
FCC Part 15.
CISPR 22 and CISPR 11.
Conducted:
Conducted:
B
B
Class
ESD
Per EN 61000-4-2, level 2.
Radiated Susceptibility Per EN 61000-4-3, level 3.
3
V/m
kV
EFT/Burst
Per EN 61000-4-4, level 3.
Per EN 61000-4-5, class 3.
1
Input Transient
Protection
Line-to-Line:
Line-to-Ground:
1
2
kV
RF Immunity
Per EN 61000-4-6, level 3.
Per EN 61000-4-8.
Per EN 61000-4-11
Per EN 60950
3
1
V/m
A/m
Magnetic Fields
Voltage Interruptions
Leakage Current
At 115 VAC:
At 230 VAC:
0.2
0.4
mA
JUL 05, 2006 revised to DEC 05, 2006
Page 3 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Environmental Specifications
Parameter
Conditions/Description
Min.
Nom.
Max.
Units
Altitude
Operating.
Non-Operating.
10K
50K
ASL ft
ASL ft
Operating Temp
0 ºC to 70 ºC with linear derating to 50% above
50 ºC. Unit will start-up at -20 ºC, but will not
meet all published specifications.
0
50
70
ºC
Storage Temp
-40
85
ºC
Temperature
Coefficient
0 ºC to 70 ºC (after 15-minute warm-up).
±0.02
%/ ºC
Relative Humidity
Shock
95% relative humidity @ 40 ºC, non-condensing
95
15
%RH
G
Operating: half-sine, 11 ±3 ms, 3-axis.
Non-Operating: half-sine, 11 ±3 ms, 3-axis.
40
G
Vibration
Operating: Random vibration; 5 to 500 Hz
(10 minutes, each axis).
2.4
Grms
Non-Operating: Random vibration; 5 to 500 Hz
(10 minutes, each axis).
6
Grms
JUL 05, 2006 revised to DEC 05, 2006
Page 4 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Mechanical Drawing – Single Output Models
All dimensions are in inches.
CN1 - AC CONN.
Pin 1
Pin 3
Pin 5
AC Neutral
AC Line
AC Ground
4.00 +/- 02
3.750
CN2 - DC CON
Ø 0.16 (4 places)
Pin #1
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
VOUT
DC COM
VOUT
TOP VIEW
DC COM
VOUT
CN2 - DC output
CN1 input
connector
connector
(see pin-out
table)
2.07
+/-.02
Pin #1
1.750
PCB AC Ground Connection
Point - Solder side
fastener
clearance area
0.25 DIA (4
places)
0.06
0.91
1.07
+/-.02
END VIEW
SIDE VIEW
Printed Circuit Board
0.1
*
RECOMMENDED MATING CONNECTORS
HOUSING
PIN
CN1 and CN2
MOLEX 22-01-2051
MOLEX 22-01-2057
MOLEX 22-01-3057
MOLEX 08-52-0123
MOLEX 08-52-0101
LEOCO 2530S05000
LEOCO 2533TPB0000
*
Equivalent housings and pins can also be used.
JUL 05, 2006 revised to DEC 05, 2006
Page 5 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Mechanical Drawing – Triple Output Model
All dimensions are in inches.
CN1 - AC CONN.
Pin 1
Pin 3
Pin 5
AC Neutral
AC Line
AC Ground
4.00 +/- 02
3.750
CN2 - DC CON
Ø 0.16 (4 places)
Pin #1
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Vo3
DC Com
Vo1
TOP VIEW
DC COM
Vo2
CN2 - DC output
CN1 input
connector
connector
(see pin-out
table)
2.00
+/-.02
Pin #1
1.750
PCB AC Ground Connection
Point - Solder side
fastener
clearance area
0.25 DIA (4
places)
0.06
0.91
1.07
+/-.02
END VIEW
SIDE VIEW
Printed Circuit Board
0.1
*
RECOMMENDED MATING CONNECTORS
HOUSING
PIN
CN1 and CN2
MOLEX 22-01-2051
MOLEX 22-01-2057
MOLEX 22-01-3057
MOLEX 08-52-0123
MOLEX 08-52-0101
LEOCO 2530S05000
LEOCO 2533TPB0000
*
Equivalent housings and pins can also be used.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent
of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
JUL 05, 2006 revised to DEC 05, 2006
Page 6 of 6
www.power-one.com
相关型号:
©2020 ICPDF网 联系我们和版权申明