DSP1N5S7 [POWER-ONE]
SINGLE OUTPUT; 单路输出DSP1 SERIES
SINGLE OUTPUT
DESCRIPTION
FEATURES
The DSP1 Series is specifically designed to convert a nominal 5
volt input into an isolated output voltage. The semi-regulated
output voltages were designed to allow analog circuits and three
terminal regulators to operate within their most efficient input
voltage range. This series achieves high power densities through
the use of 350KHz fixed frequency switching converters.
• Up to 1 Watt Unregulated Output Power
• Single In Line Package
• Four Terminal Operation
• Efficiencies to 75%
• 350KHz Fixed Frequency Operation
• 700V Isolation
• -40°C to +85°C Operation
FRONT VIEW
0.40
(10.16)
Selection Chart
RT
Input Range
SIDE
VIEW
0.02
Output Output
Power
W
VDC
Model
(0.51)
VDC
mA
Min
Max
0.000
4.5
4.5
4.5
4.5
4.5
4.5
5.5
5.5
5.5
5.5
5.5
5.5
5
7
12
14
15
17
150
140
80
70
65
0.75
1.0
1.0
1.0
1.0
1.0
DSP1N5S5
DSP1N5S7
DSP1N5S12
DSP1N5S14
DSP1N5S15
DSP1N5S17
1
2
3
4
60
PINS: 0.02 (0.51) x 0.01 (0.25)
LENGTH (TYPICAL): 0.15 (3.81)
General Specifications (1)
All Models
Units
Isolation
Isolation Voltage
Input to Output 10µA
Input to Output
Capacitance
MIN
TYP
700
25
VDC
pF
Mechanical tolerances unless otherwise noted:
X.XX dimensions: 0.020 inches
X.XXX dimensions: 0.010 inches
Environmental
MIN
MAX
MIN
-40
+85
-55
Case Operating Range, Tc
(3)
°C
Storage Range
°C
MAX
105
Pin
1
Function
+INPUT
-INPUT
-OUT
Thermal Impedance (2)
General
TYP
58
°C/Watt
2
MTBF (Calculated)
Unit Weight
TYP
TYP
700,000
0.1 / 2.8
HRS
3
oz / gm
4
+OUT
Case Material
Non Conductive Plastic
NOTES
For the Most Up-To-Date Information
www.power-one.com
24 Hours/Day—7 Days/Week
(1) All parameters measured at Tc=25°C, nominal input voltage and full rated load unless otherwise
noted.
(2) The case Thermal Impedance is specified as the case temperature rise over ambient per package dis-
sipated.
(3) Derate output power linearly to 0.6 watts from 70°c to 85°c.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.
Rev. 04/2000
1
DSP1 SERIES – SINGLE OUPUT
Output Parameters (1)
Model
DSP1N5S5
DSP1N5S7
DSP1N5S12 DSP1N5S14 DSP1N5S15 DSP1N5S17
Units
Output Voltage
5
7
12
14
15
17
VDC
MIN
TYP
MAX
4.75
5.00
5.25
6.65
7.00
7.35
11.40
12.00
12.60
13.30
14.00
14.70
14.25
15.00
15.75
16.15
17.00
17.85
Output Voltage Accuracy (3)
VDC
Output Voltage, No Load
Rated Load Range
TYP
7
10
16
19
21
24
VDC
mA
MIN
MAX
0
150
0
140
0
80
0
70
0
65
0
60
Load Regulation (4)
75% - 20% Load
75% - 100% Load
TYP
TYP
+8
-5
%
Line Regulation (5)
TYP
TYP
TYP
1.6
70
%
Noise, Peak - Peak (2)
Temperature Coefficient
mVPP
400
ppm/°C
Short Circuit Protection to Common (6)
Momentary
NOTES
DSP1 SERIES APPLICATION NOTES:
(1) All parameters measured at Tc=25°C, nominal input voltage and full rated load unless otherwise noted.
(2) Measurement bandwidth is 20 MHz. Input Reflected Ripple and output noise are measured with an exter-
nal 10µF/25V tantalum capacitor connected across the input and output pins.
(3) Output Voltage Accuracy measured at 75% of maximum Rated Load.
(4) Load Regulations measured relative to 75% of maximum Rated Load Current.
(5) Line Regulation is for a 1.0% change in input Voltage.
External Capacitance Requirements
Output filtering is required for operation. A minimum of
10ꢀF is specified for optimal performance. Output capaci-
tance may be increased for additional filtering, not to
(6) Use input fuse for protection. See Applying the input.
exceed 400ꢀF. To meet the reflected ripple requirements of
the converter, an input impedance of less than 0.5 Ohms
from DC to 350KHz is required. If a capacitive input source
is farther than 2” from the converter, it is recommended to
use a 10ꢀF, 25V solid tantalum capacitor.
Regulation
This converter uses a semi-regulated design. The output will
vary as the load is changed, with output decreasing with
increasing load. See Output Voltage vs. Output Load curves.
Additionally, output voltage will change in proportion to a
change in input voltage. The typical output voltage will
change 1.2% for each 1% change in input voltage.
Negative Outputs
A negative output voltage may be obtained by connecting
the +OUT to circuit ground and connecting -OUT as the
negative output.
2
DSP1 SERIES – SINGLE OUPUT
DSP1 SERIES BLOCK DIAGRAM
OUTPUT POWER DERATING
+ INPUT
1
2
1
0.8
0.6
0.4
4
3
+ OUTPUT
- OUT
OSCILLATOR
DRIVER
– INPUT
50
60
70
80
90
100
AMBIENT TEMPERATURE
Typical Performance: (Tc=25°C)
OUTPUT VOLTAGE Vs. OUTPUT LOAD
OUTPUT VOLTAGE Vs. OUTPUT LOAD
DSP1N5S7
OUTPUT VOLTAGE Vs. OUTPUT LOAD
DSP1N5S12
DSP1N5S5
5.80
7.90
7.60
13.50
13.00
12.50
12.00
11.50
5.60
5.40
5.20
5.00
4.80
4.60
7.30
7.00
6.70
6.40
0
40
80
120
160
0
40
80
120
160
0
30
60
90
OUTPUT LOAD (mA)
OUTPUT LOAD (mA)
OUTPUT LOAD (mA)
OUTPUT VOLTAGE Vs. OUTPUT LOAD
DSP1N5S15
OUTPUT VOLTAGE Vs. OUTPUT LOAD
DSP1N5S17
OUTPUT VOLTAGE Vs. OUTPUT LOAD
DSP1N5S14
16.50
15.90
15.30
14.70
14.10
18.50
18.00
17.50
17.00
16.50
16.00
15.40
15.00
14.60
14.20
13.80
13.40
0
20
40
60
80
0
20
40
60
80
0
20
40
60
80
OUTPUT LOAD (mA)
OUTPUT LOAD (mA)
OUTPUT LOAD (mA)
EFFICIENCY Vs. OUTPUT LOAD
80
12-17 VOLT OUTPUT
60
40
20
16
5-7 VOLT OUTPUT
0
20
40
60
80
100
% OF RATED LOAD (%)
3
相关型号:
©2020 ICPDF网 联系我们和版权申明