LES006ZB [POWER-ONE]
LES SERIES - 15 WATT; LES系列 - 15 WATT型号: | LES006ZB |
厂家: | POWER-ONE |
描述: | LES SERIES - 15 WATT |
文件: | 总3页 (文件大小:181K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
LES SERIES - 15 WATT
DESCRIPTION
FEATURES
LES DC/DC converters provide up to 15 Watts of output
power in an industry standard package and footprint. With
a maximum case temperature of 100°C, the LES is well
suited for the most demanding telecom, networking, and
industrial applications. The LES features 1500 VDC
isolation, short circuit, and overtemperature protection, as
well as six-sided shielding. The LES is available with
optional enable and voltage trim pins. Please see the IAD
Series for dual output applications.
• Industry Standard Package • 24V and 48V Inputs
• Industry Standard Pinout
• 85°C Case Operation
• Short Circuit Protection
• Input Pi Filter and
6-Sided Shielding
• Regulated Outputs
• 1500V Isolation
Efficiency vs. Load (24V Input)
85
80
75
70
65
60
55
50
45
LES010YE-A
EFF. (18v)
EFF. (24v)
EFF. (36v)
TECHNICAL SPECIFICATIONS
Input
Voltage Range
10
20
30
40
50
60
70
80
90
100
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
18 - 36 VDC
36 - 75 VDC
50 mA
LOAD %
Efficiency vs. Load (48V Input)
Output
85
Setpoint Accuracy
±1%
80
75
70
65
60
55
50
Line Regulation V Min. - V Max., I
Rated
0.2% V
in
in
out
out
Load Regulation I
Min. - I
Max., V Nom.
0.5% V
out
out
in
out
Minimum Output Current
10% I
Rated
out
Dynamic Regulation, Loadstep
Pk Deviation
25% I
LES010ZE
LES015ZG
out
out
2% V
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of I
500 µs
±10%
Shutdown / Hiccup
Rated
110 - 150%
out
10
20
30
40
50
60
70
80
90
100
LOAD %
Short Circuit Current Max.
200% I
out
(12V & 15V : 4.0A when V = 0.25V)
out
out
out
OVP Trip Range
OVP Type
115 -140% V
Nom.
General
out
Second Control Loop
Turn-On Time
10 mS
Remote Shutdown
Switching Frequency
Isolation
Positive/Negative Logic
400 kHz
Notes
Input - Output
Output - Case
1500 VDC
500 VDC
†
MTBF predictions may vary slightly from model to model.
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
0.02 ppm/°C
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
-40 To +100°C
-40 To +100°C
95%
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
5 g, 10 - 55 Hz
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
6
MTBF† (Bellcore TR-NWT-000332)
Safety
2.5 X 10 hrs
UL, cUL, TUV
Units are water-washable and fully compatible with commercial spray or immersion
post wave-solder washing equipment.
Rev. 06/01
1
LES SERIES - 15 WATT
MODELS - (See the last page of section for options.)
SINGLE OUTPUT MODEL SELECTION CHART
INPUT VOLTAGE
(VOLTS)
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
MODEL
CURRENT (AMPS)*
LES008YD
LES010YE
LES015YG
24
24
24
18-36
18-36
18-36
0.6
0.8
1.1
2.5
3.3
5
3.00
3.00
3.00
75
100
100
77%
81%
84%
LES015YH
LES015YJ
LES006ZB
LES008ZD
LES010ZE
LES015ZG
LES020ZG
LES015ZH
LES015ZJ
24
24
48
48
48
48
48
48
48
18-36
18-36
36-75
36-75
36-75
36-75
40-60
36-75
36-75
1.3
1.3
12
15
1.8
2.5
3.3
5
1.25
1.00
3.00
3.00
3.00
3.00
4.00
1.25
1.00
120
150
75
85%
86%
73%
77%
81%
83%
84%
86%
86%
0.25
0.35
0.4
75
100
100
100
120
150
0.6
0.63
0.65
0.65
5
12
15
NOTES: * Maximum input current at minimum input voltage, maximum rated output power.
** At nominal V , rated output.
in
MECHANICAL DRAWING
Thermal Impedance
Pin
Tolerances
Function
Inches:
.XX ± 0.020
.XXX ± 0.010
(Millimeters)
.X ± 0.5
.XX ± 0.25
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
15.4 °C/W
12.2 °C/W
9.3 °C/W
7.4 °C/W
6.4 °C/W
1
2
3
+V
in
-V
in
No Pin
(Optional Shutdown Pin)
Pin:
± 0.002
4
5
+V
out
± 0.05
No Pin
(Optional Trim Pin)
Case:
6
-V
+ 0.04, - 0.00
+ 1.0, - 0.00
out
Note:
(Dimensions as listed unless otherwise
specified.)
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
2
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer
and add them to the model number. Example ordering options are located below the options table.
OPTION
Negative Logic
SUFFIX
APPLICABLE SERIES
REMARKS
N
HAS, HBD, HBS, HES, HLS, HLD, LES,
QBS, QES, QLS, TES, TQD
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
Lucent-Compatible
T
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Terminal Strip
Trim
TS
1
XWS, XWD, XWT
IAS, LES
Enable
2
IAD, IAS, LES, SMS
IAS, LES
Trim and Enable
Current Share
Headerless
3
4
SMS
Y
Encapsulated EWS, IWS, OWS
Pin Length and Heatsink Options
0.110" (2.8mm) Pin Length
Standard Pin Length is 0.180" (4.6mm)
8
9
All Units (Except SMS)
All Units (Except SMS)
0.150" (3.8mm) Pin Length
0.24" (6.1mm) Horizontal Heatsink
1H
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
0.24" (6.1mm) Vertical Heatsink
0.45" (11.4mm) Horizontal Heatsink
0.45" (11.4mm) Vertical Heatsink
0.95" (24.1mm) Horizontal Heatsink
0.95" (24.1mm) Vertical Heatsink
1V
2H
2V
3H
3V
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
All Units (All Units Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
3
相关型号:
©2020 ICPDF网 联系我们和版权申明