C3567VJ

更新时间:2024-11-08 23:24:20
品牌:POWERBOX
描述:Overvoltage protection with auto restart

C3567VJ 概述

Overvoltage protection with auto restart

C3567VJ 数据手册

通过下载C3567VJ数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
C3500 Series  
7 0 0 - 8 5 0 W AT T A C / D C - D C / D C - B AT T E R Y C H A R G E R S S I N G L E O U T P U T  
FEATURES  
DC input 18 - 640 V  
AC input 1 or 3-phase, 47 - 400 Hz  
DC output 5-400V  
Continuous short circuit protection  
Overvoltage protection with auto restart  
Thermal shutdown with auto restart  
Industrial grade components  
Compact and robust design  
DC/DC CONVERTERS  
700W  
850W  
INPUTVDC  
OUTPUTVDC  
18 –36  
VDC  
OUTPUT  
AMPS  
3675  
VDC  
4590  
VDC  
80160  
VDC  
160 – 320  
VDC  
320 – 380 1)  
VDC  
320 – 640 3)  
OUTPUT  
AMPS  
ADJ.  
RANGE  
VDC  
C 3520  
C 3521  
C 3522  
C 3523  
C 3524  
C 3525  
C 3529  
C 3526  
C 3527  
C 3527 J  
C 3528  
C 3528 J  
80  
55  
50  
40  
27  
23  
12  
10  
5.3  
3.5  
2.8  
1.7  
C 3530  
C 3531  
C 3532  
C 3533  
C 3534  
C 3535  
C 3539  
C 3536  
C 3537  
C 3540  
C 3541  
C 3542  
C 3543  
C 3544  
C 3545  
C 3549  
C 3546  
C 3547  
C 3550  
C 3551  
C 3552  
C 3553  
C 3554  
C 3555  
C 3559  
C 3556  
C 3557  
C 3570  
C 3571  
C 3572  
C 3573  
C 3574  
C 3575  
C 3579  
C 3576  
C 3577  
C 3580 Z  
C 3581 Z  
C 3582 Z  
C 3583 Z  
C 3584 Z  
C 3585 Z  
C 3589 Z  
C 3586 Z  
C 3587 Z  
C 3587 ZJ  
C 3588 Z  
C 3588 ZJ  
C 3570 G  
C 3571 G  
C 3572 G  
C 3573 G  
C 3574 G  
C 3575 G  
C 3579 G  
C 3576 G  
C 3577 G  
C 3577 GJ  
C 3578 G  
C 3578 GJ  
100  
65  
56  
45  
30  
27  
14  
12  
6.5  
4
5
4.5 – 5.5  
8 – 10  
9
12  
11 – 13  
15  
14 – 16  
24  
23 – 26  
28  
26 – 30  
48  
45 – 55  
60  
58 – 68  
110  
200  
220  
400  
100 – 130  
190 – 200  
200 – 250  
380 – 400  
C 3537 J C 3547 J C 3557 J C 3577 J  
C 3538 C 3548 C 3558 C 3578  
C 3538 J C 3548 J C 3558 J C 3578 J  
3.5  
2
AC/DC POWER SUPPLIES  
850W  
INPUTVAC,1-PHASE  
INPUTVAC,3-PHASE  
OUTPUTVDC  
OUTPUT  
AMPS  
115 20%  
230+15%  
20%  
230 + 15%  
– 20%  
3X200+15% 3X400+15% 3X480 +15%  
115 20%  
ADJ.  
RANGE  
20%  
20%  
– 20%  
2
C 3560  
C 3561  
C 3562  
C 3563  
C 3564  
C 3565  
C 3569  
C 3566  
C 3567  
C 3580  
C 3581  
C 3582  
C 3583  
C 3584  
C 3585  
C 3589  
C 3586  
C 3587  
C 3590  
C 3591  
C 3592  
C 3593  
C 3594  
C 3595  
C 3599  
C 3596  
C 3597  
C 3560 V  
C 3561 V  
C 3562 V  
C 3563 V  
C 3564 V  
C 3565 V  
C 3569 V  
C 3566 V  
C 3567 V  
C 3567 VJ  
C 3568 V  
C 3568 VJ  
C 3580 V  
C 3581 V  
C 3582 V  
C 3583 V  
C 3584 V  
C 3585 V  
C 3589 V  
C 3586 V  
C 3587 V  
C 3587 VJ  
C 3588 V  
C 3588 VJ  
C 3590 V  
C 3591 V  
C 3592 V  
C 3593 V  
C 3594 V  
C 3595 V  
C 3599 V  
C 3596 V  
C 3597 V  
C 3597 VJ  
C 3598 V  
C 3598 VJ  
100 )  
5
4.5 – 5.5  
8 – 10  
65  
56  
45  
30  
27  
14  
12  
6.5  
4
9
12  
11 – 13  
15  
14 – 16  
24  
23 – 26  
28  
26 – 30  
48  
45 – 55  
60  
58 – 68  
110  
200  
220  
400  
100 – 130  
190 – 200  
200 – 250  
380 – 400  
C 3567 J C 3587 J C 3597 J  
C 3568 C 3588 C 3598  
3.5  
2
C 3568 J C 3588 J C 3598 J  
BATTERY CHARGERS  
850W  
INPUTVAC,1-PHASE  
INPUTVAC,3-PHASE  
OUTPUTVDC  
OUTPUT  
AMPS  
115 20%  
230+15%  
20%  
3X200+  
15%  
20%  
3X400+  
15%  
20%  
3X480 +  
15%  
– 20%  
NOM.  
BATTERY  
VOLTAGE  
230 +15%  
– 20%  
115 20%  
RANGE  
B 3561  
B 3562  
B 3564  
B 3566  
B 3567  
B 3568  
B 3581  
B 3582  
B 3584  
B 3586  
B 3587  
B 3588  
B 3591  
B 3592  
B 3594  
B 3596  
B 3597  
B 3598  
B 3561 V  
B 3562 V  
B 3564 V  
B 3566 V  
B 3567 V  
B 3568 V  
B 3581 V  
B 3582 V  
B 3584 V  
B 3586 V  
B 3587 V  
B 3588 V  
B 3591 V  
B 3592 V  
B 3594 V  
B 3596 V  
B 3597 V  
B 3598 V  
50  
28  
15  
12  
7
12  
24  
12 – 16  
24 – 32  
48  
48 – 64  
60  
60 – 80  
110  
220  
110 – 145  
220 - 290  
3.5  
Doc. No. PBC9 Rev.C 28-4-11  
Euro Series  
E U R O O P T I O N S P E C I F I C AT I O N S  
OPTIONS  
INPUT  
Option “i” (inrush current limiting): A thermistor is connected in series with the  
input lines which changes its resistance from high to low when it gets hot. It does  
not reduce the current surge if the input power is interrupted for a short period of  
time not allowing the thermistor to cool down. Thermistors are fitted as standard  
to all mains input models except for 1-phase input of models > 2.5kW.  
Thermistors are available up to 45A. For higher input current an electronic inrush  
current limitation can be offered.  
Option “y” (sys-reset): This logic signal is a combination of power fail and DC-ok  
as specified for VME systems.  
Option “r” (relay): A relay instead of a logic signal is provided for failure  
indication.`  
PROGRAMMING & MONITORING  
Option “ie” electronic inrush current limiting An electronic circuit limits the inrush  
current.  
PROGRAMMING SERIES 200-5800, 6600  
By external signal, 0-10Vdc  
By external signal, 4-20mA  
By 270° potentiometer  
eu1  
eu2  
eu3  
eu4  
ei1  
ei2  
ei3  
ei4  
iso  
Option “sd” (series diode): A series diode protects the module against input  
voltage of wrong polarity (additional power losses).  
Of output voltage  
from 0 to 100%  
Option “ad” (anti-parallel diode):To avoid the power losses of a series diode a diode is  
provided with opposite polarity in parallel to the input blowing an internal or external  
fuse if the module is connected to a supply with wrong polarity.  
By 10 turn potentiometer  
By external signal, 0-10Vdc  
By external signal, 4-20mA  
By 270° potentiometer  
Of output current  
from 0 to 100%  
Option “au” (auto-ranging) For standard dual AC input models the range of  
115/230Vac is to be selected by connecting the input line to different pins on the  
connector. With auto-ranging the unit senses the input voltage and provides  
automatically the correct connection.  
By 10 turn potentiometer  
Isolating amplifier for programming  
Option “p” (power fail): A signal (logic or relay) is given if the input voltage (AC or  
DC) drops below the specified limit. In AC input units we sense the rectified input  
voltage so that a power fail alarm will not be triggered if at light loads mains  
power returns before the input capacitors are substantially discharged.  
Programming via interface RS232 or IEEE488  
MONITORING SERIES 200-5800, 6600  
By external signal, 0-10Vdc  
mu1  
mu2  
mi1  
mi2  
iso  
Of output voltage  
from 0 to 100%  
Option “r” (relay): A relay instead of a logic signal is provided for failure indication.  
By external signal, 4-20mA  
By external signal, 0-10Vdc  
By external signal, 4-20mA  
OUTPUT  
Of output current  
from 0 to 100%  
Option “dd” (decoupling diode): For redundant operation the outputs of two or  
more units are paralleled behind de-coupling diodes so that an internal fault of  
one module does not affect the operation of the others. These diodes cause power  
losses.  
Isolating amplifier for programming  
Programming via interface RS232 or IEEE488  
Option “cs” (active current sharing): An additional control circuit provides active  
current sharing via an interconnecting wire between converters that operate in  
parallel. Active current sharing should be used for multi-output units operating in  
parallel.  
CHARGER PROGRAMMING (ALL SERIES)  
Temperature compensated charging voltage(sensor not included)  
Not interchangeable due to fixed  
tc  
ts1  
ts2  
ch1  
ch2  
ch3  
resistor values  
Temperature sensor  
Option “csi” (current sharing interrupt): Option “csi” will effect the removal of the  
“cs” signal. Should there be an instance where a unit is not supplying the load,  
then the effect of its “cs” signal is removed, and the load voltage is unaffected by  
this condition.  
Interchangeable, IC controlled  
Automatic selection of charging characteristic (float / equalize  
charge) with timer  
Additionally: Manual selection of charging characteristic  
Option “h1” (inhibit): A terminal connected to the negative input line also shuts off the  
converter. This can also be used in conjunction with a thermal trip which shuts the unit  
down.  
Additionally: Boost charge operation (manually activated with  
time delayed return to normal operation)  
Option “h2” (inhibit): Operation of the unit is inhibited if a voltage signal  
(5V/10mA) is applied in reference to the negative line of the (main) output.  
Option “rco” (reducing current limiting at over temperature) A circuit reduces the  
current limiting level at higher temperature (to be specified).  
Option “d” (DC-ok, one output): A logic signal is given if the output voltage (main  
output in multi-output systems) is below the specified limit.  
Option “m” (DC-ok, all outputs): In multi-output systems a logic signal is provided  
if the voltage of any output is below the specified limit.  
Option “ac” (AC ok) A logic signal connected to relay contacts is given if the  
output voltage of an inverter is below the specified limit.  
Doc. No. PBC9 Rev.C 28-4-11  
Powering Progress – www.powerbox.com.au  
Euro Series  
E U R O O P T I O N S P E C I F I C AT I O N S  
PROGRAMMING / MONITORING- SERIES 6400  
Programming of output voltage  
By external signal, 0-10Vdc  
e1  
and current from 0-100%  
including isolation  
By external signal, 4-20mA  
By 270° potentiometer  
e2  
eu3  
eu4  
ei3  
Programming of output voltage  
from 0-100%  
By 10 turn potentiometer  
By 270° potentiometer  
Programming of output current  
from 0-100%  
By 10 turn potentiometer  
By external signal, 0-10Vdc  
By external signal, 4-20mA  
By external signal, 0-10Vdc  
By external signal, 4-20mA  
Via RS232 and IEEE488  
ei4  
Monitoring of output voltage  
and current from 0-100%  
including isolation  
Remote on/off programming  
and monitoring of output  
voltage and current from  
0-100% including isolation  
m1  
m2  
em1  
em2  
em3  
Improved tolerance  
Between reference (external  
signal) and measured value /  
between measured value and  
displayed signal: voltage 0.2%  
and current 0.5%.  
tol  
ENVIRONMENT  
Option “t” (tropical protection):The unit is given additional protection by a heavy  
coat of varnish on the printed circuit board(s) and components.  
Option “c” (extended temperature range):The circuit is designed and tested for  
operation at an ambient temperature as low as –40 °C.  
Option “ms” (increased mechanical strength): Screws are secured by Locktite and  
heavy components are fastened by ties and/or glue. Modules with the “ms” option  
meet the standard EN61373 regarding shock and vibration.  
MECHANICS  
Standard mounting “Eurocassette” pluggable module for 19” sub-racks 84TE  
Option “w” (wall mounting): Module is screwed against a mounting plate for  
installation in a cabinet. The load connections are typically a terminal block.  
Option “cha” (chassis mount) Module is designed for installation to a structure or  
within cabinet. Screw type connectors are supplied with the module.  
Option “din” (DIN rail mount) Module is designed for DIN rail mounting to a  
structure or within Cabinet. Screw type connectors are supplied with the module.  
Doc. No. PBC9 Rev.C 28-4-11  

C3567VJ 相关器件

型号 制造商 描述 价格 文档
C3568 POWERBOX Overvoltage protection with auto restart 获取价格
C3568J POWERBOX Overvoltage protection with auto restart 获取价格
C3568V POWERBOX Overvoltage protection with auto restart 获取价格
C3568VJ POWERBOX Overvoltage protection with auto restart 获取价格
C356C104G2G5TA KEMET Ceramic Capacitor, Ceramic 获取价格
C356C104J1G5TA KEMET Ceramic Capacitor, Ceramic, 100V, 5% +Tol, 5% -Tol, C0G, 30ppm/Cel TC, 0.1uF, Through Hole Mount, 5020, RADIAL LEADED 获取价格
C356C104K2G5TA KEMET Ceramic Capacitor, Ceramic 获取价格
C356C106J1R5HA7301 KEMET Radial Leaded Multilayer Ceramic Capacitors 获取价格
C356C106J1R5TA7301 KEMET Radial Leaded Multilayer Ceramic Capacitors 获取价格
C356C106J2R5HA7301 KEMET Radial Leaded Multilayer Ceramic Capacitors 获取价格

C3567VJ 相关文章

  • 强制中企出售股权,英国半导体领域渐成中企投资禁区
    2024-11-08
    22
  • 台积电拟对大陆AI公司禁运7nm及以下工艺,引发业界关注
    2024-11-08
    15
  • 锐成芯微推出基于8nm工艺的PVT Sensor IP,引领芯片技术创新
    2024-11-08
    16
  • 苹果与富士康接洽,商讨在中国台湾生产AI服务器
    2024-11-08
    14