PH9185.021NL [PULSE]
High Isolation Power Transformers;型号: | PH9185.021NL |
厂家: | PULSE A TECHNITROL COMPANY |
描述: | High Isolation Power Transformers 变压器 |
文件: | 总2页 (文件大小:443K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
High Isolation Power Transformers
EP7 Platform SMD - PH9185.XXXNL and PM2190.XXXNL
Push Pull Transformer
Reinforced insulation for isolated power supply
driver
8mm creepage
5KVrms isolation (1000Vrms continuous)
7
UL and TUV certified
Electrical Specifications @ 25°C - Operating Temperature -40°C to +125°C
Inductance (1-3) Leakage Inductance DCR (1-3) DCR (4-6)
ET MAX (1-3)1
Part Number
CAP
(pF MAX)
Turns Ratio
(1:3) (6:4)
Isolated Voltage4
(Vrms)
Commercial
Automotive8
PM2190.011NL
PM2190.012NL
PM2190.013NL
PM2190.021NL
(µH 45%)
(µH MAX)
(Ω MAX)
(Ω MAX) (V-µsec MAX)
PH9185.011NL
PH9185.012NL
PH9185.013NL
PH9185.021NL
750
1.2
0.50
0.55
0.80
0.95
0.45
0.75
1.00
0.56
0.40
66
52
10.0
10.0
8.0
1CT : 1CT
1CT : 2CT
1CT : 3CT
2CT : 1CT
3CT : 4CT
3CT : 8CT
4CT : 3CT
8CT : 3CT
450
0.9
0.40
0.35
200
0.6
36
1800
750
3.0
0.75
100
66
44
89
110
10.0
10.0
8.0
5000
PH9185.034NL PM2190.034NL
PH9185.038NL PM2190.038NL
PH9185.043NL PM2190.043NL
PH9185.083NL PM2190.083NL
1.2
0.50
310
0.9
0.44
1260
2350
1.5
0.70
12.0
8.0
6.0
0.90
Notes:
1. The ET Max is calculated to limit the core loss and temperature rise at 100KHz based on a
bipolar flux swing of 180mT Peak.
C. To calculate temperature rise, use the following formula: Temperature Rise (°C) =
90 * (Core Loss(W) + Copper Loss (W))
2. For Push-Pull topology, where the voltage is applied across half the primary winding
turns, the ET needs to be derated by 50% for the same flux swing.
3. The applied ET may need to be further derated for higher frequencies based on the
temperature rise which results from the core and copper losses
4. The AEC-Q200 temperature and humidity operational life testing was completed using a
dielectric strength test of 5000Vdc.
5. Optional Tape & Reel packing can be ordered by adding a “T” suffix to the part number
(i.e. PH9185.012NL becomes PH9185.012NLT). Pulse complies to industry standard tape and
reel specification EIA481.
A. To calculate total copper loss (W), use the following formula:
Copper Loss (W) = Irms_Primary2 * DCR_Primary + Irms_Secondary2*DCR_Secondary 6. The “NL” suffix indicates an RoHS-compliant part number.
B. To calculate total core loss (W), use the following formula:
Core Loss (W) = 4.40E-10 * (Frequency in kHz)1.67 * (180 * [ET/ET Max])2.53
Where ET is the applied Volt Second, ET Max is the rated Volt Second for 180mT flux
swing
7. Continuous isolation voltage confirmed by 125°C/1000hrs accelerated aging with the bias
voltage applied between primary and secondary windings.
8. The PM2190.XXXNL part numbers are AEC-Q200 and IATF16949 certified.
9. Special Characteristics
Schematic
Mechanical
PH9185.XXXNL/PM2190.XXXNL
Weight ...................2.6grams
Tape & Reel ...............150/reel
Tray .............................80/tray
Inches
mm
Dimensions:
Unless otherwise specified,
.010
0,25
all tolerances are
power.pulseelectronics.com
http://www.power.pulseelectronics.com/contact
P708. O (02/20)
1
High Isolation Power Transformers
EP7 Platform SMD - PH9185.XXXNL and PM2190.XXXNL
TAPE & REEL INFO
W
A
K
0
P
1
G
Direction of tape
SURFACE MOUNTING TYPE, REEL/TAPE LIST
REEL SIZE (mm) TAPE SIZE (mm)
QTY
PCS/REEL
150
PART NUMBER
A
G
P1
W
32
K0
PH9185.XXXNLT/PM2190.XXXNLT
Ø330
32.4
24
12.8
APPLICATION
PH9185.XXXNL is a series of high isolation power supply transformer drivers. Intended to operate in a fixed duty cycle Push Pull topology, it is a part of a low
cost solution for delivering lower power (up to 3W) from a low voltage source. A typical implementation would be an isolated RS-485/RS-232 power supply
driver circuit, the design is compatible with the MAXIM™ MAX253 IC.
VIN
A schematic diagram for the Push Pull converter topology is given below.
PH9185/PM2190
VCC
D1
D2
V
OUT
DRIVER
IC
GND
For a fixed 50% duty cycle mode of operation, the output voltage is simply determined by the input voltage and turns ratio. So, with the available turns ratios,
a variety of output voltages can be selected.
This transformer design has been certified by UL to comply with UL60950-1 2nd edition, and CAN/CSA C22.2 NO. 60950-1-07 2nd edition; and by TUV to comply
with EN61558-1 and EN61558-2-16 with reinforced insulation for a working voltage up to 400Vac 8mm creepage and 5000Vrms isolation voltage is guaranteed
to meet this requirement. The design also complies with the Pulse’s class F insulation system. PH9185.013NL was not included in the original UL/TUV certification
but is complaint. Cost reduced versions without UL/TUV certification available, please contact Pulse Electronics for more information.
MAXIM is a registered trademark of Maxim Integrated Products.
For More Information
Pulse Worldwide
Headquarters
15255 Innovation Drive Ste 100
San Diego, CA 92128
U.S.A.
Pulse Europe
Pulse China Headquarters
Pulse Electronics (ShenZhen) CO., LTD
D708, Shenzhen Academy of
Aerospace Technology,
The 10th Keji South Road,
Nanshan District, Shenzhen,
P.R. China 518057
Pulse North China
Room 2704/2705
Super Ocean Finance Ctr.
2067 Yan An Road West
Shanghai 200336
China
Pulse South Asia
3 Fraser Street
0428 DUO Tower
Singapore 189352
Pulse North Asia
1F., No.111 Xiyuan Rd
Zhongli City
Taoyuan City 32057
Taiwan (R.O.C)
Pulse Electronics GmbH
Am Rottland 12
58540 Meinerzhagen
Germany
Tel: 858 674 8100
Fax: 858 674 8262
Tel: 49 2354 777 100
Fax: 49 2354 777 168
Tel: 86 755 33966678
Fax: 86 755 33966700
Tel: 86 21 62787060
Fax: 86 2162786973
Tel: 65 6287 8998
Fax: 65 6280 0080
Tel: 886 3 4356768
Fax: 886 3 4356820
Performance warranty of products offered on this data sheet is limited to the parameters specified. Data is subject to change without notice. Other brand and product names mentioned herein may
be trademarks or registered trademarks of their respective owners. © Copyright, 2020. Pulse Electronics, Inc. All rights reserved.
power.pulseelectronics.com
http://www.power.pulseelectronics.com/contact
P708. O (02/20)