POWER LINE CHOKE
(DRUM CORE STYLE)
Electrical Specifications at 25
O
C
Parameter
Min.
Typ.
Max.
Units
Custom Specifications:
Working voltage 2000 volts typ.
Isolation 2000 Vrms, from core to
winding.
Part wound using wire with teflon
sleaving.
Bottom of part insulated with
mylar tape rated at 6500 Volts.
Finish with a shrink tubing.
Inductance
I
MAX
DCR
Lead Diameter
1
16
20
25
13
.0508
(1.29)
24
µH
A
mΩ
inches
(mm)
Test Conditions:
Inductance tested at 100 mV
RMS
and 300 kHz
1. Current for 10% drop in Inductance
PHYSICAL DIMENSIONS All dimensions in inches
D
C
Dim.
A
B
C
D
inches
1.390
1.010
0.315
0.190
B
.750"
TYP.
High Saturation
Pre-Tinned Leads
Center hole for mechanical mounting
A
Leads are .0508 (# 16 AWG)
Leads tinned to within 1/8" of body.
RHOMBUS P/N:
CUST P/N:
DATE:
12/20/01
L-735
NAME:
SHEET:
1 OF 1
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971