NBFM Multichannel 500mW VHF Transceiver  
UHX1 is small dual frequency multi-  
channel VHF transceiver with up to  
500mW RF power output.  
The dual frequency capability allows  
UHX1’s transmitter section to be  
operated on one frequency while  
receiver frequency on another.  
Figure 1: UHX1-144-5  
Features  
Conforms to ETSI EN 300 220-3 and EN 301 489-3  
High performance double superhet, 128 channel PLL synthesizer  
500mW RF power output: adjustable via serial command  
Data rates up to 5 kbps for standard module  
Usable range over 1km  
Fully screened. Low profile  
Feature-rich interface (RSSI, analogue and digital baseband)  
Digital RSSI output  
Incorporate a 1200baud modem  
Re-programmable via RS232 interface  
Low power requirements  
Applications  
Handheld terminals  
Heavy vehicle/machine remote controls  
EPOS equipment, barcode scanners  
Data loggers  
Industrial telemetry and telecommand  
In-building environmental monitoring and control  
High-end security and fire alarms  
Vehicle data up/download  
Technical Summary  
Operating frequency: Any 2MHz segment in 140- 175MHz  
128 channels selected by serial interface  
16 channels selected by parallel interface  
Transmit power: 500mW (+27dBm) nominal. Adjustable 1 – 500mW  
Supply range: 5V regulated transmit, 3.1 - 15V receive,  
Current consumption: 330mA (at 500mW output) transmit, 25mA receive  
Data bit rate: 5kbps max. (standard module)  
Receiver sensitivity: -118dBm (for 12 dB SINAD)  
Size: 67 x 30 x 12mm  
Radiometrix Ltd  
UHX1 Data Sheet (preliminary)  
page 1  
Radiometrix Ltd  
UHX1 Data Sheet (preliminary)  
page 2  
Figure 3: Provisional UHX1 footprint  
Pin Description  
Pins  
Normal mode  
Serial mode  
Modem  
mode  
RF  
1A  
2A  
3A  
4A  
5A  
6A  
User  
1
RF Gnd  
RF ground  
RF in/out To the antenna  
RF Gnd  
GND  
GND  
RF ground  
0V  
0V  
Vcc (TX)  
5V regulated supply for TX  
TXD  
TXE  
DC coupled input for TTL/ CMOS logic  
Transmit enable.  
Low = TX mode  
0V  
DC supply input (3.1 –15V) for receiver  
Parallel channel select MSB  
Parallel channel select  
NC  
NC  
2
3
4
5
6
7
8
9
GND  
Vcc  
P3  
Serial read back  
TBA  
TBA  
PGM in  
BUSY  
P2  
P1  
P0  
MOD TXD  
MOD RXD  
PGM in  
Parallel channel select  
Parallel channel select LSB  
DC level between 0.5V and 2.5V. 60dB dynamic  
range  
RSSI  
10  
11  
RXD  
AF out  
Open collector output of data slicer  
500mV p-p audio. DC coupled, approx 0.8V bias  
NC  
NC  
NOTES:  
1. No inversion occurs between TXD and RXD. However, AF out is inverted relative to mod in.  
2. P0 - P3 (parallel channel selects) and TXE are active LOW and have internal 47K pullups to 3v.  
3. Open collector output RXD has a 47K pullup to 3v.  
4. The software incorporates a 1200baud dumb modem, compatible with that implemented in  
other Radiometrix narrowband units ( i1200 tones and format ). Modem operation is selected by  
a serial command.  
5. Main serial port (P0-P3) operates at 9600 baud. (Command set is not the same as TR2M, SMX  
families). The unit is capable of operating in 'basic' parallel channel select only mode, or in  
serial controlled 'expanded' mode.  
6. Transmit power can be set by serial command.  
7. RSSI, and other status information, can be read back as a digital value. (on P3).  
7a. The RSSI is a high impedence output. If a low impedence voltage source (an op-amp output) is  
connected to the RSSI out pin then this voltage (0-2.5v) will override the RSSI value during  
RSSI 'digital read' operations.  
8. If analogue transmit modulation is needed, then connect a series 1uF cap + 500K trimmer (a  
multiturn is advised) in the 'baseband TXD' circuit. Adjust trimmer for 90% of peak deviation  
(+/- 2.7KHz) at mean input level.  
9. The high current (250mA max.) transmitter supply (5v regulated) is fed to a separate connector  
10. A version without a RX/TX switch is available. This unit has a 4 pin RF connector (RX, GND,  
TX, GND) and is intended for use with external power amplifiers  
Radiometrix Ltd  
UHX1 Data Sheet (preliminary)  
page 3  
Serial interface commands  
The UHX1 user interface is accessed through the four parallel pins (P0/serial through P3).  
It has four operating modes:  
1. Parallel.  
Frequency of operation is selected as one of 16 (chans 0-15), by means of a 4 bit inverted value applied  
to P0-P3. The P0 pin will also respond to a LOCKSERIALMODE datastream (inverted rs232, 9600  
baud), which will cause the radio to enter serial mode. In parallel mode, the IDENT command string is  
still decoded, but the unit remains in parallel mode.  
2. Serial  
Frequency of operation, radio set up, power output and various other parameters are controlled by  
command strings sent to P0. Pin P3 functions as a 'readback' port while P1,2 are not used in this mode.  
In this mode, decimal values are used (to simplify direct manual programming via a terminal)  
Commands include:  
Commands  
Function  
empty command buffer  
read back buffer contents  
delete last character  
process buffer  
Notes  
:
? or /  
<backspace>  
<cr>  
PARALLEL  
return to the basic, parallel mode (and turn  
modem off)  
DUMP  
MODEM  
NOMODEM  
read back contents of EEPROM (output on P3)  
activate 1200 baud modem  
de-activate 1200 baud modem  
#
#
DEFCH ccc  
DEFPOW pp  
set default channel (non-volatile)  
set default tx power (non-voltatile)  
#
#
CHAN ccc  
POWER pp  
RSSI  
jump to channel (volatile)  
select tx power (volatile)  
single read of RSSI (output on P3)  
SHORT  
enter short command mode  
#
(The following commands are used to set up the radio operating characteristics, and should be viewed  
with caution. Especially the CALPOWER command, which initiates a multiple write operation to the  
power calibration table )  
Commands  
NDIV nnnnn  
RDIV rrrrr  
RLOAD rrrrr  
OFFSET ooooo  
LOAD aa nnnnn  
START nnnnn  
STEP i  
Function  
Notes  
force N divider value (volatile)  
force R divider value (volatile)  
Set R divider value  
#
#
#
#
#
#
Set RX offset  
Set N values for first 16 channels  
Set N value for ch 16  
Set increment for table  
Set highest permitted channel number  
Set maximum power output (500mW)  
(see factory procedures for more details)  
Generate a 250Hz test modulation (only fuctions in  
TX mode, cancelled by sending a <cr> byte)  
Readback a single byte, depending on current  
mode:  
LIMIT ccc  
SETPOW eee  
CALPOWER (etc)  
TEST  
IDENT  
Radiometrix Ltd  
UHX1 Data Sheet (preliminary)  
page 4  
Commands  
Function  
Parallel:  
Serial:  
Notes  
P
S
I
Short:  
Modem:  
M
(Channels 0-15 are individually programmed by the LOAD operation. Channels 16-127 are a  
consecutive table, using the START value as a start point (=channel 16) and increasing the N value by  
STEP with each increase in channel number)  
ccc  
aa  
= a channel number from 00 to 127  
= a two digit channel number from 00 to 15  
nnnnn = synthesizer N register value, (up to 65535)  
rrrrr = synthesizer R register value, (up to 16383)  
pp  
i
= power setting value (3-30: a value of 30 corresponds to a power output of +27dBm)  
= table step (increments of N) (0-7)  
ooooo = receive mode frequency offset  
eee = power calibration figure  
N = channel frequency / (10MHz / R)  
10MHz / R = 25KHz , so R = 400 (usually)  
receive offset = 21.4MHz / (10MHz / R) , so = 856 (usually)  
A pause of at least 50mS must be allowed after operations which result in eeprom programming  
operations (all except NDIV, RDIV, GOTO, PSET and RSSI). This allows the programming cycle to  
complete.  
Instructions marked ' # ' output a three byte ' OK<cr> ' sequence after sucessfully completing their  
eeprom programming cycles  
When first powered up, the unit will operate on channel and output level specified by the last CHAN  
and POWER instructions, irrespective of previous NDIV, RDIV, CHAN or PSET operations)  
3. Short  
A limited range of radio functions are controlled by sending a single byte to PO  
0
- 127  
select channel  
select power  
(volatile)  
( = byte -128) (volatile)  
(output on P3)  
128 - 159  
200  
201  
222  
single read of RSSI  
single byte read, as for IDENT command  
reception of 16 consecutive 222 bytes returns radio to serial mode.  
This mode of operation is intended to provide a simple, fast, serial command mode.  
4. Modem  
Commands are interpreted as in SERIAL mode (and 'short' mode may be selected.) In this mode the  
unit operates as a simple 1200 baud packet modem, with TXD (in) on P2 and RXD (out) on P1.  
The TXE pin does not control tx switching in this mode, but rather the presence of valid data in the tx  
buffer initiates a transmit burst. No handshaking is provided, and the unit has a sufficient over-link  
data rate to transparently 'stream' continuous data. Error correction, re-transmission of corrupt packets  
and addressing are not provided.  
This mode is compatible with other Radiometrix 'i 1200' mode equipment, including the narrow band  
eval kit.  
Notes:  
1. Unlike in the RLC and TLC units, the LOCKSERIALMODE (and FAST) commands are non-  
volatile. Once a serial mode is selected, the unit will power up in this mode until a PARALLEL  
command is received.  
Radiometrix Ltd  
UHX1 Data Sheet (preliminary)  
page 5  
2. The command interpreter IS case sensitive. Use upper case.  
3. Spaces are optional (they are not decoded), provided the command line does not exceed 16  
characters.  
4. When manually programming this unit we recommend setting your terminal to local echo. The  
'backspace' key functions normally.  
5. All serial communications use 9600baud 'inverted RS232' 8 bit data, no parity, 1 start bit, 1 or  
2 stop bits  
6. A simple 'driver' program will be made available to simplify programming of these units, if  
desired.  
7. RSSI read operations only function correctly if the unit is in RX mode (TXE pin is high or  
floating)  
Condensed specifications (All details are provisional)  
Frequency  
Any 2MHz segment in 140 - 175MHz  
(TX and RX frequencies need not be the same)  
+/-5ppm (better than 1.5kHz)  
20kHz or 25kHz (12.5kHz by special order)  
128 channels by serial RS232 interface or 16 by parallel select  
Frequency stability  
Channel spacing  
Number of channels  
Supply  
Receive  
3.1 -15V at 24mA  
Transmit:  
5.0V regulated  
55mA (at 10mW output)  
270mA (at 500mW output)  
(plus 20mA at 3.6-15v from pin4: Vcc)  
-20 to +70 C (Storage -30 to +70 C)  
Compliant with ETSI EN 300 220-3 and EN 301 489-3  
Operating temperature  
Spurious radiations  
Interface  
User  
11 pin 0.1" pitch molex  
6 pin 0.1" pitch molex  
5 pin 0.1" pitch socket in top of case  
1.2mm (min.)  
RF and TX supply  
Reprogram  
Recommended PCB hole size  
Size  
67 x 30 x 12mm  
Transmitter  
500mW (+27dBm); Adjustable via serial command 1 - 500mW in 1dB steps)  
Output power  
TX on switching time  
Modulation type  
TX modulation bandwidth  
Deviation  
Adjacent channel TX power  
TX spurii  
Inputs  
<50 ms  
FM, FSK (F1D, F3D)  
DC – 3kHz  
3kHz ( 1.5kHz for 12.5kHz channel variant)  
-37dBm  
<-40dBm  
Data (CMOS/TTL compatible)  
Receiver  
Sensitivity  
image / spurious  
blocking  
-118dBm for 12dB SINAD  
-65dB  
-86dB  
adjacent channel  
Outputs  
-65dB (tested per ETSI EN300 086)  
RSSI, Audio, Data  
Dynamic timing  
RX data recovery settling time 20ms  
Power on to stable (50:50  
mark / space) RXD  
Maximum time between data  
transitions  
50ms (TXE low/active to stable RX data out)  
250ms  
Radiometrix Ltd  
UHX1 Data Sheet (preliminary)  
page 6  
Radiometrix Ltd  
Hartcran House  
231 Kenton Lane  
Harrow, Middlesex  
HA3 8RP  
ENGLAND  
Tel: +44 (0) 20 8909 9595  
Fax: +44 (0) 20 8909 2233  
sales@radiometrix.com  
www.radiometrix.com  
Copyright notice  
This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in wholeor  
in part must give clear acknowledgement to the copyright owner.  
Limitation of liability  
The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the  
right to make changes or improvements in the design, specification or manufacture of its subassembly products  
without notice. Radiometrix Ltd does not assume any liability arising from the application or use of any product or  
circuit described herein, nor for any infringements of patents or other rights of third parties which may result from  
the use of its products. This data sheet neither states nor implies warranty of any kind, including fitness for any  
particular application. These radio devices may be subject to radio interference and may not function as intended if  
interference is present. We do NOT recommend their use for life critical applications.  
The Intrastat commodity code for all our modules is: 8542 6000.  
R&TTE Directive  
After 7 April 2001 the manufacturer can only place finished product on the market under the provisions of the  
R&TTE Directive. Equipment within the scope of the R&TTE Directive may demonstrate compliance to the  
essential requirements specified in Article 3 of the Directive, as appropriate to the particular equipment.  
Further details are available on The Office of Communications (Ofcom) web site:  
http://www.ofcom.org.uk/radiocomms/ifi/  
Information Requests  
European Radiocommunications Office (ERO)  
Peblingehus  
Ofcom  
Riverside House  
Nansensgade 19  
2a Southwark Bridge Road  
London SE1 9HA  
DK 1366 Copenhagen  
Tel. +45 33896300  
Fax +45 33896330  
ero@ero.dk  
Tel: +44 (0)845 456 3000 or 020 7981 3040  
Fax: +44 (0)20 7783 4033  
information.requests@ofcom.org.uk  
www.ero.dk  

相关型号:

UHZ0J102MPJ

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 6.3V, 1000uF, THROUGH HOLE MOUNT, RADIAL LEADED
NICHICON

UHZ0J102MPM

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON

UHZ0J102MPM1FV

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 6.3V, 20% +Tol, 20% -Tol, 1000uF,
NICHICON

UHZ0J122MPM

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON

UHZ0J152MPM

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON

UHZ0J152MPM6AA

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 6.3V, 20% +Tol, 20% -Tol, 1500uF,
NICHICON

UHZ0J182MPJ

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 6.3V, 1800uF, THROUGH HOLE MOUNT, RADIAL LEADED
NICHICON

UHZ0J182MPM

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON

UHZ0J182MPM1AA

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 6.3V, 20% +Tol, 20% -Tol, 1800uF,
NICHICON

UHZ0J222MPJ3

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 6.3V, 2200uF, THROUGH HOLE MOUNT, RADIAL LEADED
NICHICON

UHZ0J222MPM

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON

UHZ0J222MPM3AA

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 6.3V, 20% +Tol, 20% -Tol, 2200uF,
NICHICON