RAC02-SE277 [RECOM]

35mW max. No Load Power Consumption;
RAC02-SE277
型号: RAC02-SE277
厂家: RECOM INTERNATIONAL POWER    RECOM INTERNATIONAL POWER
描述:

35mW max. No Load Power Consumption

文件: 总4页 (文件大小:402K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
• 35mW max. No Load Power Consumption  
• Efficiency up to 76%  
• Isolated Output 3kVAC / 1 min  
• SCP, OVP Protection  
Features  
AC/DC Converter  
Regulated  
Converters  
• Wide Operating Temperature Range:  
-40°C to +85°C  
• Universal Input 85-305VAC  
RAC02-SE/277  
2 Watt  
Single  
Description  
The ultra-compact RAC02-SE/277 modules are available with output voltages of 3.3, 5, 12 and  
24V, and the input-to-output isolation is 3kVAC/1min. With a standby consumption of 35mW  
maximum, the mini power supplies are particularly suitable for energy-saving sleep mode and  
standby applications. Because of its compact design (height <18mm), it is a versatile solution for home  
automation and other similar applications. Complete with an integrated input filter, the series has  
enhanced EMI performance and complies with EN55022, class B. The mini power supplies are  
also protected against short circuit with fully automatic restart after the error has been solved. The  
converters are EN/UL60950-1 certified and come complete with a 3 year warranty.  
Output  
Selection Guide  
Part  
Number  
nom. Input  
Voltage Range  
[VAC]  
Output  
Voltage  
[VDC]  
Output  
Current  
[mA]  
Efficiency  
typ.  
Max. Capacitive  
Load (1)  
[%]  
[µF]  
RAC02-3.3SE/277  
RAC02-05SE/277  
RAC02-12SE/277  
RAC02-24SE/277  
100-277  
100-277  
100-277  
100-277  
3.3  
5.0  
12  
600  
400  
167  
83  
67  
70  
73  
76  
12000  
5500  
500  
24  
160  
Notes:  
Note1: Test by minimum input and constant resistor load.  
E224736  
EN55024 Certified  
EN60950-1 Certified  
UL60950-1 Certified  
EN60335-1 Certified  
Specifications (measured @ ta= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
Max.  
85VAC  
120VDC  
305VAC  
430VDC  
Input Voltage Range  
115VAC  
230VAC  
47mA  
30mA  
Input Current  
Inrush Current  
115VAC  
230VAC  
15A  
30A  
cold start at +25°C  
No load Power Consumption  
Input Frequency Range  
Hold-up time  
85-305VAC, 47-63Hz  
AC Input  
35mW  
440Hz  
47Hz  
115VAC  
18ms  
Internal Operating Frequency  
Minimum Load  
100% load at nominal Vin  
55kHz  
2%  
3.3V  
5V, 12V, 24V  
300mVp-p  
250mVp-p  
Output Ripple and Noise(2)  
Notes:  
Note2: Ripple and Noise is the maximum peak-to-peak voltage value measured at the output with a  
20MHz bandwidth, at rated line voltage at full load. And with a 47µF low-ESR electrolytic  
capacitor in parallel with a 0.1µF ceramic capacitor across output.  
continued on next page  
www.recom-power.com  
REV.: 8/2017  
PA-1  
RAC02-SE/277  
AC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)  
Efficiency vs. Load  
RAC02-05SE/277  
80  
70  
60  
50  
40  
30  
20  
10  
0
115VAC  
230VAC  
277VAC  
0
0.1  
0.2  
0.3  
0.4  
Output Current [A]  
REGULATIONS  
Parameter  
Condition  
Value  
6.0% max.  
1.5% max.  
6.0% typ.  
Output Voltage Tolerance(3)  
Line Voltage Regulation  
Load Voltage Regulation  
low line to high line, full load  
2% to 100% load  
Notes:  
Note3: Includes initial voltage accuracy, thermal drift, line regulation and load regulation at rated input voltage and load conditions.  
PROTECTIONS  
Parameter  
Type  
Value  
continuous, automatic recovery  
110% - 140%  
110% - 190%  
OVC II  
Short Circuit Protection (SCP)  
Over Voltage Protection (OVP)  
Over Current Limit  
Zener Diode clamp  
Over Voltage Category  
Isolation Voltage  
tested for 1 minute  
3kVAC  
Isolation Resistance  
Leakage Current  
1Gmin.  
85-305VAC, 47-63Hz  
10µA max.  
Notes:  
Note4: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: T1A slow blow type  
Note5: An external MOV is recommended. The Varistor should comply with IEC-61051-2. e.g. EPCOS S14 Series  
L N  
FUSE  
U
PA-2  
REV.: 8/2017  
www.recom-power.com  
RAC02-SE/277  
AC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)  
ENVIRONMENTAL  
Parameter  
Condition  
230VAC, with derating (see graph)  
Value  
-40°C to +85°C  
+105°C  
Operating Temperature Range (6)  
Maximum Case Temperature  
Thermal Impedance  
Humidity  
8.5°C/W typ.  
non-condensing  
5% - 95%, RH max.  
MIL-STD-202G  
Vibration  
115VAC  
230VAC  
2238 x 103 hours  
1670 x 103 hours  
MTBF (7)  
MIL-HDBK-217F G.B., +25°C  
Derating Graph  
@ 85-140VAC  
@ 140-305VAC  
100  
80  
100  
3.3V and 5V  
all other models  
80  
60  
all models  
60  
50  
50  
40  
40  
20  
0
20  
0
-40 -20  
0
10  
20 30  
40  
50 60  
70 80  
75  
90 100  
-40 -20  
0
10  
20 30  
40  
50 60  
70 80  
75 85  
90 100  
-25  
85  
Ambient Temperature [°C]  
Ambient Temperature [°C]  
Notes:  
Note6: At low input voltage (85-140VAC) and temperature below -25°C the RAC02-3.3SE/277 and RAC02-05SE/277, will not start.  
SAFETY AND CERTIFICATIONS  
Certificate Type (Safety)  
Report / File Number  
Standard  
IEC60950-1, 2nd Edition, 2009  
EN60950-1, 2nd Edition, 2011  
Information Technology Equipment, General Requirements for Safety (LVD)  
LVD1208051  
UL60950-1, 2nd Edition, 2014  
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition 2014  
Information Technology Equipment, General Requirements for Safety  
Household and similar electrical appliances, General requirements  
E224736-X1-A24  
L0339L26-B2  
EN60335-1, 2014  
EMC Compliance  
Condition  
Standard / Criterion  
Information technology equipment - Radio disturbance  
characteristics - Limits and methods of measurement  
EN55022, Class B  
EN55024  
Report: 1502CE17  
ESD Electrostatic discharge immunity test  
Radiated, radio-frequency, electromagnetic field immunity test  
Fast Transient and Burst Immunity  
8kV Air Discharge; 6kV Contact  
3V/m  
EN61000-4-2, Criteria B  
EN61000-4-3, Criteria A  
EN61000-4-4, Criteria B  
EN61000-4-5, Criteria B  
EN61000-4-6, Criteria A  
EN61000-4-8, Criteria A  
AC Power Port: 1kV  
AC Power Port: line to line: 1kV  
AC Power Port: 3V/m  
1 A/m  
Surge Immunity  
Immunity to conducted disturbances, induced by radio-frequency fields  
Power Magnetic Field Immunity  
Voltage Dips and Interruption  
Voltage Dips: >95% reduction  
>30% reduction  
Interruption: >95%  
EN61000-4-11, Criteria B  
EN61000-4-11, Criteria C  
EN61000-4-11, Criteria C  
Voltage Fluctuations and Flicker in Public Low-Voltage Systems  
EN61000-3-3  
www.recom-power.com  
REV.: 8/2017  
PA-3  
RAC02-SE/277  
AC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)  
DIMENSION and PHYSICAL CHARACTERISTICS  
Parameter  
Type  
Value  
Case  
Potting  
black plastic (UL94 V-0)  
silicone (UL94 V-0)  
Material  
Package Dimension (LxWxH)  
Package Weight  
33.7 x 22.2 x 17.75mm  
24.5g typ.  
Dimension Drawing (mm)  
embossed logo  
5.0  
33.7  
28.0  
Ø 0.8 0.1  
Pin Connections  
Pin #  
Single  
VAC in (N)  
VAC in (L)  
-Vout  
1
2
3
4
2
1
Bottom View  
4
3
+Vout  
18.0  
tc  
Tolerance: xx.x=  
0.5mm  
xx.xx= 0.35mm  
0.05mm  
Pin width:  
PACKAGING INFORMATION  
Parameter  
Type  
tube  
Value  
520.0 x 37.0 x 28.0mm  
22 pcs  
Packaging Dimension (LxWxH)  
Packaging Quantity  
Storage Temperature Range  
-40°C to +85°C  
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written  
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer  
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.  
PA-4  
REV.: 8/2017  
www.recom-power.com  

相关型号:

RAC02-SE277W

35mW max. No Load Power Consumption
RECOM

RAC02E-05SK/277

2 Watt 1.35” x 0.88” Single Output
RECOM

RAC02E-12SK/277

2 Watt 1.35” x 0.88” Single Output
RECOM

RAC02E-15SK/277

2 Watt 1.35” x 0.88” Single Output
RECOM

RAC02E-24SK/277

2 Watt 1.35” x 0.88” Single Output
RECOM

RAC02E-3.3SK/277

2 Watt 1.35” x 0.88” Single Output
RECOM

RAC02E-K

2 Watt 1.35” x 0.88” Single Output
RECOM

RAC02E-K/277

2 Watt 1.35” x 0.88” Single Output
RECOM

RAC03-05SA

Ultracompact AC-DC Power Supply
RECOM

RAC03-05SC

3 Watt Single Output
RECOM

RAC03-05SC-277

AC/DC-Converter
RECOM

RAC03-05SE

30mW max. No Load Power Consumption
RECOM