RAC04-0512DC/230 [RECOM]
4 Watt Single Dual Output;型号: | RAC04-0512DC/230 |
厂家: | RECOM INTERNATIONAL POWER |
描述: | 4 Watt Single Dual Output |
文件: | 总3页 (文件大小:90K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
● Universal Input 80-264VAC
● 100mW max No load Power Consumption
● Efficiency up to 79%
● High Operating Temperature Range
(-40°C to +80°C)
● Isolated Output 3.75kVAC / 1 min
● Continuous Short Circuit Protection
● Meet EN55022 Class B
POWERLINE
AC/DC-Converter
with 3 year Warranty
Features
Regulated
Converters
● EN, UL and CE Certified
4 Watt
Single &
Dual Output
The RAC04-C/230 series are fully certified single and dual regulated
AC/DC converters in an encapsulated PCB-mount package style with
3.75kVAC isolation and very low standby power consumption. The
converters have SC protected single as well as dual outputs and meet
EN55022 class B without any external components. Uses include
board-level power supplies, home automation, instrumentation
systems and standby applications.
Description
Selection Guide
Part
Number
Input
Voltage
(VAC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(Typ.)
Max.
Capacitive
Load**
(%)
RAC04-3.3SC/230 80-264
3.3
5
1200
800
72
75
77
78
79
75
76
78
10000μF
7200μF
1000μF
820μF
RAC04-05SC/230
RAC04-12SC/230
RAC04-15SC/230
RAC04-24SC/230
80-264
80-264
80-264
80-264
12
15
24
5/12
5
333
267
167
220μF
RoHS
2011/65/EU
6/6
RAC04-0512DC/230 80-264
720/33
400
4700/100μF
3300μF
680μF
E224736
RAC04-05DC/230
80-264
EN-60950-1 certified
UL-60950-1 certified
RAC04-12DC/230
80-264
12
166
** measured @115VAC
Specifications (measured at TA 25°C, full load after warm-up)
Input Voltage Range (with Derating)
RAC04-C/230
80-264VAC or 113-373VDC
47-440Hz
Input Frequency
Input Current (Full Load)
Inrush Current
115VAC/230VAC
115VAC/230VAC
115VAC/230VAC 50/60Hz
Single Outputs
Dual Outputs
98mA / 64mA max.
15A / 30A max.
100mW max.
2ꢀ typ.
No Load Power Consumption
Output Voltage Accuracy (Full Load)
Derating-Graph
2ꢀ typ.
(Ambient Temperature)
5V / 12V
2ꢀ / 10ꢀ typ.
0.2ꢀ typ.
Line Voltage Regulation (90-264VAC)
Single Outputs
Dual Outputs
100
0.2ꢀ typ.
80
5V / 12V
0.2ꢀ / 1ꢀ typ.
1ꢀ typ.
Safe Operating Area
60
50
40
Load Voltage Regulation
(10ꢀ - 100ꢀ load)
3.3V/5V Output
All Others
0.5ꢀ typ.
20
0
5V / 12V
1ꢀ / 5ꢀ typ.
200mVp-p typ.
Output Ripple&Noise
80
-40
-20
0
20
40
60
65
(measured @ 20MHz of bandwidth with 0.1μF & 47μF parallel capacitors)
Ambient Temperature Range (°C)
Switching Frequency (Full Load)
67kHz typ.
15ms min.
Hold-Up Time
115VAC
Minimum Load
Isolation Voltage
Leakage Current
Isolation Resistance
0ꢀ
Input-Output
3.75kVAC / 1minute
0.25mA max.
230VAC / 50Hz
100M Ω min.
continued on next page
PA-20
REV: 0/2015
www.recom-power.com
RAC04-xxxC/230
Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, full load after warm-up)
Short Circuit Protection
Over Voltage Category
Auto Recovery
OVC II
Operating Temperature Range
-40°C to +65°C (without Derating)
Natural Convection
-40°C to +80°C
(with Derating)
Storage Temperature Range
Case Material
Relative Humidity
Package Weight
Dimension
-40°C to +100°C
UL94V-0 Black Plastic
95ꢀ RH max.
Non-condensing
31.5g typ.
(L x W x H)
Conducted and Radiated
Noise Immunity
36.7 x 27.2 x 17.1mm
EN55022 Class B
EN55024
EMC
MTBF (+25°C)
Certification
MIL-HDBK-217F
CE
500 x 10³ hours
EN55022 Class B
UL General Safety
EN General Safety
CB General Safety
Report: E224736
Report: 131055-1CB-M1
Report: 131055-1CB-M1
UL60950-1, 2nd Edition
EN60950-1, 2006, 2nd Edition + A12:2012
IEC 60950-1: 2005; 2nd Edition
Efficiency vs Load
Single Output 115VAC
Dual Output 115VAC
90
80
24SC
15SC
12SC
05SC
3.3SC
90
80
12DC
05DC
0512DC
70
60
50
40
30
20
10
0
70
60
50
40
30
20
10
0
0
10 20 30 40 50 60 70 80 90 100
Load (%)
0
10 20 30 40 50 60 70 80 90 100
Load (%)
Single Output 230VAC
Dual Output 230VAC
90
80
90
80
24SC
15SC
12SC
05SC
3.3SC
05DC
12DC
0512DC
70
60
50
40
30
20
10
0
70
60
50
40
30
20
10
0
0
10 20 30 40 50 60 70 80 90 100
Load (%)
0
10 20 30 40 50 60 70 80 90 100
Load (%)
www.recom-power.com
REV: 0/2015
PA-21
RAC04-xxxC/230
Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, full load after warm-up)
Application Note:
0.1uF/50V
100
L
Vout+
Vout-
VAC (L)
VAC (N)
Fuse 1A
Load
80
N
47uF/50V
60
SAFE OPERATING AREA
40
1. Recommended external input fuse 1A/slow blow type.
2. To measure the output ripple & noise connect 0.1uF/50V & 47uF/50V @20MHz,
as close to pins as possible with nominal input and full load. Please see above.
20
0
80 90 100 115
230 264
Input Voltage (VAC)
Package Style and Pinning
27.2
26.5
36.7
36.0
17.1
4.0
21.0
0.6
Pin Connections
21.5
7.5
Pin #
Single Out
No Pin
Dual Output
No Pin
Dual Output
No Pin
3.1
Primary
1
7
6
5
2
+VDC out
-VDC out
NC
+Vout
+Vout
Isolation
Spacing
3
Com
Com
4
-Vout
+12V
21.0
Bottom View
5
VAC in (L)
VAC in (N)
NC
VAC in (L)
VAC in (N)
NC
VAC in (L)
VAC in (N)
NC
6
7*
1
2 3 4
Secondary
NC = No Connection
3.8
21.5
3.75x2
xx.x = 0.5mm
xx.xx = 0.25mm
* Pin 7 is NC but need 4mm minimum clearence to ground for safety.
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-22
REV: 0/2015
www.recom-power.com
相关型号:
©2020 ICPDF网 联系我们和版权申明