RAC04-24SK/277 [RECOM]

4 Watt Single Output;
RAC04-24SK/277
型号: RAC04-24SK/277
厂家: RECOM INTERNATIONAL POWER    RECOM INTERNATIONAL POWER
描述:

4 Watt Single Output

文件: 总7页 (文件大小:2035K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
• 80 to 305VAC input voltage range  
• 150% peak power capability  
• Wide temperature range: -40°C to +90°C  
• No load power consumption <150mW  
• Household and ITE certified  
Features  
AC/DC Converter  
Regulated  
Converter  
• 4kVac isolation  
04-K/277  
Description  
4 Watt  
Single  
Output  
The RAC04-K/277 series delivers an uncompromising 4 watts of continuous output power (6W peak) in harsh  
industrial and household environments. These modules deliver full load output power from -40°C to 75°C across  
the entire input range of 80VAC to 305VAC and are certified for operation with power derating up to 90°C air  
ambient. A peak load capability of up to 150% supports dynamic power demands of applications. This series of  
fully encapsulated AC/DC modules is a complete solution without the need for external components which supports  
Ecodesign Lot 6 standby mode operation for worldwide applications in automation, industry 4.0, IoT, household,  
and home automation. With international safety and EMC certifications for industrial, domestic, ITE, and household  
applications, these are some of the most versatile power modules on the market. Due to their reinforced class II  
installation rating for floating outputs and their significantly wide margin to class B emissions compliance without  
external components and a certified 4kV AC (5.25 kV DC) isolation, these are the easiest to use modular power  
solutions in the industry.  
Selection Guide  
Part  
Number  
Input  
Voltage Range  
[(VAC]  
Output  
Voltage  
[VDC]  
Output  
Current (1)  
[mA]  
Efficiency  
typ. (2)  
[%]  
Max. Capacitive  
Load  
[µF)  
RAC04-05SK/277  
RAC04-12SK/277  
RAC04-15SK/277  
RAC04-24SK/277  
80-305  
80-305  
80-305  
80-305  
5
800  
333  
267  
167  
76  
78  
80  
80  
7200  
1000  
820  
12  
15  
24  
E224736  
220  
On Request  
RAC04-3.3SK/277  
80-305  
3.3  
1200  
73  
10000  
Notes:  
Note1: Refer to “Line Derating“ graph  
Note2: Measured @ 230VAC/50Hz at +25°C with constant resistant mode at full load  
IEC60950-1 (pending)  
IEC62368-1 (pending)  
UL62368-1 certified  
CSA/CAN C22.2 No. 62368-1-14 certified  
EN62368-1 compliant  
EN60335-1 compliant  
IEC/EN61558-1 compliant  
IEC/EN61558-2-16 compliant  
EN55032 compliant  
Model Numbering  
EN55024 compliant  
EN55014-1 /-2 compliant  
IEC/EN61204-3 compliant  
FCC 47 Part 15  
RAC04-__ SK/277  
nom. Output Power  
nom. Output Voltage  
Single  
CB Report (pending)  
Ordering Examples  
RAC04-05SK/277 =  
RAC04-12SK/277 = 12Vout  
5Vout  
Single  
Single  
www.recom-power.com  
REV.: 0/2019  
PA-1  
RAC04-K/277  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
Max.  
nom. Vin= 277VAC  
80VAC  
110VDC  
305VAC  
390VDC  
Input Voltage Range (3)  
115VAC  
230VAC  
250mA  
100mA  
Input Current  
115VAC  
230VAC  
80-305VAC, 50/60Hz  
10A  
20A  
Inrush Current  
cold start at +25°C  
No load Power Consumption  
100mW  
150mW  
ErP Standby Mode Conformity  
(Output Load Capability)  
0.5W  
1W  
0.3W  
0.65W  
Input Power=  
Input Frequency Range  
Start-up Time  
AC input  
47Hz  
0%  
63Hz  
20ms  
10ms  
Rise Time  
115VAC  
230VAC  
20ms  
80ms  
Hold-up time  
Minimum Load  
Power Factor  
115VAC  
230VAC  
0.6  
0.45  
Internal Operating Frequency  
Output Ripple and Noise (4)  
full load  
130kHz  
1% of nom. Vout  
Notes:  
Note3: The products were submitted for safety files at AC-Input operation  
Note4: Measurements are made with a 1.0µF MLCC and a 10µF MLCC across output  
Efficiency vs. Load  
RAC04-05SK/277  
RAC04-12SK/277  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
115VAC  
230VAC  
277VAC  
115VAC  
230VAC  
277VAC  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
continued on next page  
REV.: 0/2019  
www.recom-power.com  
PA-2  
RAC04-K/277  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
RAC04-15SK/277  
RAC04-24SK/277  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
115VAC  
230VAC  
277VAC  
115VAC  
230VAC  
277VAC  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
REGULATIONS  
Parameter  
Condition  
Value  
Output Accuracy  
Line Regulation  
Load Regulation  
1.0% typ.  
0.5% typ.  
1.0% typ.  
25% load step change  
recovery time  
4.0% max.  
500µs  
Transient Response  
Deviation vs. Load  
(80-305VAC)  
RAC04-05SK/277  
RAC04-12SK/277  
1
0.5  
0
1
0.5  
0
-0.5  
-1  
-0.5  
-1  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
continued on next page  
REV.: 0/2019  
www.recom-power.com  
PA-3  
RAC04-K/277  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
RAC04-15SK/277  
RAC04-24SK/277  
1
0.5  
0
1
0.5  
0
-0.5  
-1  
-0.5  
-1  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
PROTECTIONS  
Parameter  
Type  
internal  
Value  
Input Fuse (5)  
T1A, slow blow  
Hiccup Mode, auto recovery  
125% - 195%, Hiccup Mode  
OVCII  
Short Circuit Protection (SCP)  
Over Voltage Protection (OVP)  
Over Voltage Category (OVC)  
Over Current Protection (OCP)  
Class of Equipment  
150% - 210%, Hiccup Mode  
Class II  
5.75kVDC  
4kVAC  
Isolation Voltage(safety certified) (6)  
I/P to O/P  
I/P to O/P  
1 mintue  
Isolation Resistance  
Isolation Capacitance  
Insulation Grade  
Viso= 500VDC  
1Gmin.  
100pF max.  
reinforced  
100kHz, 0.1V  
Leakage Current  
0.25mA max.  
Notes:  
Note5: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type  
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage.  
Peak Load Capability (7)  
Pout [%]  
Peak Load Calculation  
Pnom = nom. output power  
[W]  
PP = peak output power (6W max.) [W]  
Pp  
Pnom x (t1 + t2) - PP x t1  
t2 x k  
Pr = recovery output power  
t1 = peak time set (10s max.)  
t2 = recovery time (min. 4 x t1  
[W]  
[s]  
[s]  
[ ]  
Pr =  
Pnom  
Pr  
)
k
= safety factor 1.3  
Practical Example:  
Take the RAC04-05SK/277 at 230VAC input Voltage and full load at TAMB= 50°C (4W).  
Time [s]  
t1  
t2  
Pnom. = please refer to derating graph (4W)  
PP = 6W  
4 x (10 + 4 x 10) - (6 x 10)  
t1 = 10s  
t2 = min. 4 x t1  
Pr =  
= 2.69W  
4 x 10 x 1.3  
Notes:  
k
= 1.3  
Note7: Peak load calculation valid for 100-305VAC  
www.recom-power.com  
REV.: 0/2019  
PA-4  
RAC04-K/277  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
ENVIRONMENTAL  
Parameter  
Condition  
Value  
full load  
-40°C to +75°C  
Operating Temperature Range @ natural convection 0.1m/s  
refer to “Derating Graph“  
-40°C to +90°C  
Maximum Case Temperature  
Temperature Coefficient  
+100°C  
0.02%/K  
Operating Altitude (8)  
Operating Humidity  
Pollution Degree  
Vibration  
according to IEC62368-1 (EN60335-1)  
non-condensing  
5000m (4000m)  
20% - 95%, RH max.  
PD2  
according to MIL-STD-202G  
10-500Hz, 2G 10min. / 1 cycle, periode 60min. each along x, y, z axis  
MTBF  
according to MIL-HDBK-217F, G.B  
+25°C  
+25°C  
+70°C  
+25°C  
+70°C  
>500 x 103 hours  
125 x 10³ hours  
51 x 103 hours  
105 x 103 hours  
37 x 103 hours  
230VAC  
277VAC  
Design Lifetime  
Notes:  
Note8: Recognized by safety agency for safe operation up to 5000m. High altitude operation may impact the performance and lifetime.  
Please contact RECOM tech support for advice.  
Line Derating  
Derating Graph  
(@ Chamber and natural convection 0.1m/s)  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
ꢀꢁꢂꢃꢄ ꢅꢆꢇꢈ  
ꢉꢁꢂꢃꢄ ꢅꢆꢇꢈ  
0
-40 -20 -10  
0
10 20 30 40 50 60 70 80 90 100  
80  
90 100  
305  
75  
Ambient Temperature [°C]  
Input Voltage [VAC]  
SAFETY AND CERTIFICATIONS  
Certificate Type  
Report / File Number  
Standard  
UL62368-1:2014, 2nd Edition  
Audio/video, information and communication technology equipment - Safety requirements  
E224736  
CAN/CSA C22.2 No. 62368-1-14, 2nd Edition  
IEC60950-1:2005 + A2:2013, 2nd Edition  
IEC/EN62368-1:2014, 2nd Edition  
EN62368-1:2014 + A11:2017  
Information Technology Equipment, General Requirements for Safety (CB)  
(pending)  
(pending)  
Audio/video, information and communication technology equipment - Safety requirements (CB)  
Audio/video, information and communication technology equipment - Safety requirements (LVD)  
Household and similar electrical appliances - Safety - Part 1: General requirements (LVD)  
EN60335-1:2012 + A1:2018  
Safety of power transformers, power supplies, reactors and similar products for supply voltages  
up to 1100 V  
IEC61558-1:2005 2nd Edition + A1:2009  
EN61558-1:2005 + A1:2009  
continued on next page  
REV.: 0/2019  
www.recom-power.com  
PA-5  
RAC04-K/277  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
Certificate Type  
Report / File Number  
Standard  
Safety of transformers, reactors, power supply units and similar products for supply voltages up  
to 1100 V - Part 2-16: Particular requirements and tests for switch mode power supply units and  
transformers for switch mode power supply units (LVD)  
IEC61558-2-16:2009 + A1:2013, 1st Edition  
EN61558-2-16:2009 + A1:2013  
Safety requirements for electrical equipment for measurement, control and laboratory use -  
Part 1: General requirements (LVD)  
EN61010-1:2010  
RoHS2  
RoHs-2011/65/EU + AM-2015/863  
EMC Compliance (Household)  
Report / File Number  
Standard / Criterion  
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar  
apparatus - Part 1: Emission (8)  
EN55014-1:2006 + A2:2011  
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar  
apparatus - Part 2: Immunity  
EN55014-2:2015  
ESD Electrostatic discharge immunity test  
Fast Transient and Burst Immunity  
Air 8kV; Contact 4kV  
AC Power Port: 1.0kV  
AC Power Port: L-N 1.0kV  
AC Power Port: 3V  
IEC61000-4-2:2008, Criteria B  
IEC61000-4-4:2012, Criteria B  
IEC61000-4-5:2014, Criteria B  
EN61000-4-6:2013, Criteria A  
Surge Immunity  
Immunity to conducted disturbances, induced by radio-frequency fields  
100%  
Voltage Dips:  
60%  
EN61000-4-11:2004, Criteria C  
EN61000-4-11:2004, Criteria C  
Voltage Dips and Interruptions  
EMC Compliance (Multimedia)  
Condition  
Standard / Criterion  
IEC/EN61204-3:2000, Class B  
EN55032:2015, Class B  
Low voltage power supplies, d.c. output - Part 3: Electromagnetic compatibility  
Electromagnetic compatibility of multimedia equipment - Emission requirements (9)  
Information technology equipment - Immunity characteristics - Limits and methods of measurement  
ESD Electrostatic discharge immunity test  
EN55024:2010 + A1:2015  
IEC61000-4-2:2008, Criteria B  
IEC61000-4-3, Criteria A  
Air 2,4,8kV; Contact 4kV  
10V/m (80 - 1000MHz)  
Radiated, radio-frequency, electromagnetic field immunity test  
3V/m (1800MHz, 2600Mhz,  
3500MHz, 5000MHz)  
IEC61000-4-3:2006 + A2:2010, Criteria A  
AC Power Port: 2.0kV  
AC Power Port: 1.0kV  
AC Power Port: L-N 1.0kV  
AC Power Port: 10V  
IEC61000-4-4, Criteria B  
IEC61000-4-4:2012, Criteria A  
IEC61000-4-5:2014, Criteria A  
IEC61000-4-6, Criteria A  
Fast Transient and Burst Immunity  
Surge Immunity  
Immunity to conducted disturbances, induced by radio-frequency fields  
100% / 30%  
IEC61000-4-11:2004, Criteria A  
IEC61000-4-11:2004, Criteria B  
IEC61000-4-11:2004, Criteria C  
Voltage Dips:  
70%  
40%  
Voltage Dips and Interruptions  
Interruptions: >95%  
IEC61000-4-11:2004, Criteria A  
Limits of Voltage Fluctuations & Flicker  
EN61000-3-3:2013  
Limitations on the amount of electromagnetic interference allowed from digital and electronic  
devices  
WTS19S01003086E  
FCC 47 Part 15 Subpart B:2017, Class B  
Notes:  
Note9: If output is connected to GND, please contact RECOM tech support for further information  
DIMENSION and PHYSICAL CHARACTERISTICS  
Parameter  
Type  
case/baseplate  
potting  
Value  
plastic, (UL94 V-0)  
silicone, (UL94 V-0)  
FR4, (UL94 V-0)  
Material  
PCB  
Dimension (LxWxH)  
Weight  
36.7 x 27.2 x 17.4mm  
30g typ.  
continued on next page  
REV.: 0/2019  
www.recom-power.com  
PA-6  
RAC04-K/277  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
Dimension Drawing (mm)  
36.7  
embossed logo  
Pinning information  
Pin #  
Single  
1
2
3
4
5
6
NC  
VAC in (N)  
VAC in (L)  
NC  
36.0  
26.5  
-Vout  
+Vout  
NC= no connection  
Tolerance: xx.x= 0.5mm  
xx.xx= 0.25mm  
0.05  
Ø0.6  
21.00  
Recommended footprint details  
2.54  
3.85  
21.50  
7.50  
ꢄ ꢀ ꢃ  
Bottom View  
Top View  
3.75  
3.75  
PACKAGING INFORMATION  
Parameter  
Type  
Value  
Packaging Dimension (LxWxH)  
tube  
506.4 x 29.8 x 25.5mm  
Packaging Quantity  
12pcs  
Storage Temperature Range  
Storage Humidity  
-40°C to +85°C  
20% to 90% RH max.  
non-condensing  
The product information and specifications may be subꢀect to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The  
products are not authorized for use in safety-critical applications without RECOMꢁs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause  
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized  
use of RECOM products in such safety-critical applications.  
www.recom-power.com  
REV.: 0/2019  
PA-7  

相关型号:

RAC04-277

AC/DC-Converter with 3 year Warranty
RECOM

RAC04-3.3SA

Ultracompact AC-DC Power Supply
RECOM

RAC04-3.3SA/277

AC/DC CONVERTER 3.3V 4W
ETC

RAC04-3.3SC

Universal Input 80-264VAC or 115-370VDC
RECOM

RAC04-3.3SC/230

4 Watt Single Dual Output
RECOM

RAC04-3.3SC/277

4 Watt Single and Dual Output
RECOM

RAC04-3.3SC/W

4 Watt Single Output
RECOM

RAC04-3.3SC230

Universal Input 80-264VAC
RECOM

RAC04-3.3SC277

50mW max. No Load Power Consumption
RECOM

RAC04-3.3SCW

Universal Input 80-264VAC or 115-370VDC
RECOM

RAC04-3.3SGA

4 Watt Single Output EMC Class A
RECOM

RAC04-3.3SGB

4 Watt Single Output EMC Class B
RECOM