RAC04-K-277 [RECOM]
4 Watt Single Output;型号: | RAC04-K-277 |
厂家: | RECOM INTERNATIONAL POWER |
描述: | 4 Watt Single Output |
文件: | 总7页 (文件大小:2035K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 80 to 305VAC input voltage range
• 150% peak power capability
• Wide temperature range: -40°C to +90°C
• No load power consumption <150mW
• Household and ITE certified
Features
AC/DC Converter
Regulated
Converter
• 4kVac isolation
04-K/277
Description
4 Watt
Single
Output
The RAC04-K/277 series delivers an uncompromising 4 watts of continuous output power (6W peak) in harsh
industrial and household environments. These modules deliver full load output power from -40°C to 75°C across
the entire input range of 80VAC to 305VAC and are certified for operation with power derating up to 90°C air
ambient. A peak load capability of up to 150% supports dynamic power demands of applications. This series of
fully encapsulated AC/DC modules is a complete solution without the need for external components which supports
Ecodesign Lot 6 standby mode operation for worldwide applications in automation, industry 4.0, IoT, household,
and home automation. With international safety and EMC certifications for industrial, domestic, ITE, and household
applications, these are some of the most versatile power modules on the market. Due to their reinforced class II
installation rating for floating outputs and their significantly wide margin to class B emissions compliance without
external components and a certified 4kV AC (5.25 kV DC) isolation, these are the easiest to use modular power
solutions in the industry.
Selection Guide
Part
Number
Input
Voltage Range
[(VAC]
Output
Voltage
[VDC]
Output
Current (1)
[mA]
Efficiency
typ. (2)
[%]
Max. Capacitive
Load
[µF)
RAC04-05SK/277
RAC04-12SK/277
RAC04-15SK/277
RAC04-24SK/277
80-305
80-305
80-305
80-305
5
800
333
267
167
76
78
80
80
7200
1000
820
12
15
24
E224736
220
On Request
RAC04-3.3SK/277
80-305
3.3
1200
73
10000
Notes:
Note1: Refer to “Line Derating“ graph
Note2: Measured @ 230VAC/50Hz at +25°C with constant resistant mode at full load
IEC60950-1 (pending)
IEC62368-1 (pending)
UL62368-1 certified
CSA/CAN C22.2 No. 62368-1-14 certified
EN62368-1 compliant
EN60335-1 compliant
IEC/EN61558-1 compliant
IEC/EN61558-2-16 compliant
EN55032 compliant
Model Numbering
EN55024 compliant
EN55014-1 /-2 compliant
IEC/EN61204-3 compliant
FCC 47 Part 15
RAC04-__ SK/277
nom. Output Power
nom. Output Voltage
Single
CB Report (pending)
Ordering Examples
RAC04-05SK/277 =
RAC04-12SK/277 = 12Vout
5Vout
Single
Single
www.recom-power.com
REV.: 0/2019
PA-1
RAC04-K/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
nom. Vin= 277VAC
80VAC
110VDC
305VAC
390VDC
Input Voltage Range (3)
115VAC
230VAC
250mA
100mA
Input Current
115VAC
230VAC
80-305VAC, 50/60Hz
10A
20A
Inrush Current
cold start at +25°C
No load Power Consumption
100mW
150mW
ErP Standby Mode Conformity
(Output Load Capability)
0.5W
1W
0.3W
0.65W
Input Power=
Input Frequency Range
Start-up Time
AC input
47Hz
0%
63Hz
20ms
10ms
Rise Time
115VAC
230VAC
20ms
80ms
Hold-up time
Minimum Load
Power Factor
115VAC
230VAC
0.6
0.45
Internal Operating Frequency
Output Ripple and Noise (4)
full load
130kHz
1% of nom. Vout
Notes:
Note3: The products were submitted for safety files at AC-Input operation
Note4: Measurements are made with a 1.0µF MLCC and a 10µF MLCC across output
Efficiency vs. Load
RAC04-05SK/277
RAC04-12SK/277
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
115VAC
230VAC
277VAC
115VAC
230VAC
277VAC
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
continued on next page
REV.: 0/2019
www.recom-power.com
PA-2
RAC04-K/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC04-15SK/277
RAC04-24SK/277
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
115VAC
230VAC
277VAC
115VAC
230VAC
277VAC
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
Line Regulation
Load Regulation
1.0% typ.
0.5% typ.
1.0% typ.
25% load step change
recovery time
4.0% max.
500µs
Transient Response
Deviation vs. Load
(80-305VAC)
RAC04-05SK/277
RAC04-12SK/277
1
0.5
0
1
0.5
0
-0.5
-1
-0.5
-1
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
continued on next page
REV.: 0/2019
www.recom-power.com
PA-3
RAC04-K/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC04-15SK/277
RAC04-24SK/277
1
0.5
0
1
0.5
0
-0.5
-1
-0.5
-1
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
PROTECTIONS
Parameter
Type
internal
Value
Input Fuse (5)
T1A, slow blow
Hiccup Mode, auto recovery
125% - 195%, Hiccup Mode
OVCII
Short Circuit Protection (SCP)
Over Voltage Protection (OVP)
Over Voltage Category (OVC)
Over Current Protection (OCP)
Class of Equipment
150% - 210%, Hiccup Mode
Class II
5.75kVDC
4kVAC
Isolation Voltage(safety certified) (6)
I/P to O/P
I/P to O/P
1 mintue
Isolation Resistance
Isolation Capacitance
Insulation Grade
Viso= 500VDC
1GΩ min.
100pF max.
reinforced
100kHz, 0.1V
Leakage Current
0.25mA max.
Notes:
Note5: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage.
Peak Load Capability (7)
Pout [%]
Peak Load Calculation
Pnom = nom. output power
[W]
PP = peak output power (6W max.) [W]
Pp
Pnom x (t1 + t2) - PP x t1
t2 x k
Pr = recovery output power
t1 = peak time set (10s max.)
t2 = recovery time (min. 4 x t1
[W]
[s]
[s]
[ ]
Pr =
Pnom
Pr
)
k
= safety factor 1.3
Practical Example:
Take the RAC04-05SK/277 at 230VAC input Voltage and full load at TAMB= 50°C (4W).
Time [s]
t1
t2
Pnom. = please refer to derating graph (4W)
PP = 6W
4 x (10 + 4 x 10) - (6 x 10)
t1 = 10s
t2 = min. 4 x t1
Pr =
= 2.69W
4 x 10 x 1.3
Notes:
k
= 1.3
Note7: Peak load calculation valid for 100-305VAC
www.recom-power.com
REV.: 0/2019
PA-4
RAC04-K/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
ENVIRONMENTAL
Parameter
Condition
Value
full load
-40°C to +75°C
Operating Temperature Range @ natural convection 0.1m/s
refer to “Derating Graph“
-40°C to +90°C
Maximum Case Temperature
Temperature Coefficient
+100°C
0.02%/K
Operating Altitude (8)
Operating Humidity
Pollution Degree
Vibration
according to IEC62368-1 (EN60335-1)
non-condensing
5000m (4000m)
20% - 95%, RH max.
PD2
according to MIL-STD-202G
10-500Hz, 2G 10min. / 1 cycle, periode 60min. each along x, y, z axis
MTBF
according to MIL-HDBK-217F, G.B
+25°C
+25°C
+70°C
+25°C
+70°C
>500 x 103 hours
125 x 10³ hours
51 x 103 hours
105 x 103 hours
37 x 103 hours
230VAC
277VAC
Design Lifetime
Notes:
Note8: Recognized by safety agency for safe operation up to 5000m. High altitude operation may impact the performance and lifetime.
Please contact RECOM tech support for advice.
Line Derating
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
ꢀꢁꢂꢃꢄ ꢅꢆꢇꢈ
ꢉꢁꢂꢃꢄ ꢅꢆꢇꢈ
0
-40 -20 -10
0
10 20 30 40 50 60 70 80 90 100
80
90 100
305
75
Ambient Temperature [°C]
Input Voltage [VAC]
SAFETY AND CERTIFICATIONS
Certificate Type
Report / File Number
Standard
UL62368-1:2014, 2nd Edition
Audio/video, information and communication technology equipment - Safety requirements
E224736
CAN/CSA C22.2 No. 62368-1-14, 2nd Edition
IEC60950-1:2005 + A2:2013, 2nd Edition
IEC/EN62368-1:2014, 2nd Edition
EN62368-1:2014 + A11:2017
Information Technology Equipment, General Requirements for Safety (CB)
(pending)
(pending)
Audio/video, information and communication technology equipment - Safety requirements (CB)
Audio/video, information and communication technology equipment - Safety requirements (LVD)
Household and similar electrical appliances - Safety - Part 1: General requirements (LVD)
EN60335-1:2012 + A1:2018
Safety of power transformers, power supplies, reactors and similar products for supply voltages
up to 1100 V
IEC61558-1:2005 2nd Edition + A1:2009
EN61558-1:2005 + A1:2009
continued on next page
REV.: 0/2019
www.recom-power.com
PA-5
RAC04-K/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Certificate Type
Report / File Number
Standard
Safety of transformers, reactors, power supply units and similar products for supply voltages up
to 1100 V - Part 2-16: Particular requirements and tests for switch mode power supply units and
transformers for switch mode power supply units (LVD)
IEC61558-2-16:2009 + A1:2013, 1st Edition
EN61558-2-16:2009 + A1:2013
Safety requirements for electrical equipment for measurement, control and laboratory use -
Part 1: General requirements (LVD)
EN61010-1:2010
RoHS2
RoHs-2011/65/EU + AM-2015/863
EMC Compliance (Household)
Report / File Number
Standard / Criterion
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar
apparatus - Part 1: Emission (8)
EN55014-1:2006 + A2:2011
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar
apparatus - Part 2: Immunity
EN55014-2:2015
ESD Electrostatic discharge immunity test
Fast Transient and Burst Immunity
Air 8kV; Contact 4kV
AC Power Port: 1.0kV
AC Power Port: L-N 1.0kV
AC Power Port: 3V
IEC61000-4-2:2008, Criteria B
IEC61000-4-4:2012, Criteria B
IEC61000-4-5:2014, Criteria B
EN61000-4-6:2013, Criteria A
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
100%
Voltage Dips:
60%
EN61000-4-11:2004, Criteria C
EN61000-4-11:2004, Criteria C
Voltage Dips and Interruptions
EMC Compliance (Multimedia)
Condition
Standard / Criterion
IEC/EN61204-3:2000, Class B
EN55032:2015, Class B
Low voltage power supplies, d.c. output - Part 3: Electromagnetic compatibility
Electromagnetic compatibility of multimedia equipment - Emission requirements (9)
Information technology equipment - Immunity characteristics - Limits and methods of measurement
ESD Electrostatic discharge immunity test
EN55024:2010 + A1:2015
IEC61000-4-2:2008, Criteria B
IEC61000-4-3, Criteria A
Air 2,4,8kV; Contact 4kV
10V/m (80 - 1000MHz)
Radiated, radio-frequency, electromagnetic field immunity test
3V/m (1800MHz, 2600Mhz,
3500MHz, 5000MHz)
IEC61000-4-3:2006 + A2:2010, Criteria A
AC Power Port: 2.0kV
AC Power Port: 1.0kV
AC Power Port: L-N 1.0kV
AC Power Port: 10V
IEC61000-4-4, Criteria B
IEC61000-4-4:2012, Criteria A
IEC61000-4-5:2014, Criteria A
IEC61000-4-6, Criteria A
Fast Transient and Burst Immunity
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
100% / 30%
IEC61000-4-11:2004, Criteria A
IEC61000-4-11:2004, Criteria B
IEC61000-4-11:2004, Criteria C
Voltage Dips:
70%
40%
Voltage Dips and Interruptions
Interruptions: >95%
IEC61000-4-11:2004, Criteria A
Limits of Voltage Fluctuations & Flicker
EN61000-3-3:2013
Limitations on the amount of electromagnetic interference allowed from digital and electronic
devices
WTS19S01003086E
FCC 47 Part 15 Subpart B:2017, Class B
Notes:
Note9: If output is connected to GND, please contact RECOM tech support for further information
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
case/baseplate
potting
Value
plastic, (UL94 V-0)
silicone, (UL94 V-0)
FR4, (UL94 V-0)
Material
PCB
Dimension (LxWxH)
Weight
36.7 x 27.2 x 17.4mm
30g typ.
continued on next page
REV.: 0/2019
www.recom-power.com
PA-6
RAC04-K/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Dimension Drawing (mm)
36.7
embossed logo
Pinning information
Pin #
Single
1
2
3
4
5
6
NC
VAC in (N)
VAC in (L)
NC
36.0
26.5
-Vout
+Vout
NC= no connection
Tolerance: xx.x= 0.5mm
xx.xx= 0.25mm
0.05
Ø0.6
21.00
Recommended footprint details
2.54
3.85
21.50
7.50
ꢅ
ꢁ
ꢂ
ꢃ
ꢄ ꢀ ꢃ
Bottom View
Top View
ꢄ
ꢀ
ꢅ
ꢁ
ꢂ
3.75
3.75
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
506.4 x 29.8 x 25.5mm
Packaging Quantity
12pcs
Storage Temperature Range
Storage Humidity
-40°C to +85°C
20% to 90% RH max.
non-condensing
The product information and specifications may be subꢀect to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOMꢁs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 0/2019
PA-7
相关型号:
©2020 ICPDF网 联系我们和版权申明