RHV3-1212D/R20 [RECOM]
3 Watt SIP16 Single and Dual Output;型号: | RHV3-1212D/R20 |
厂家: | RECOM INTERNATIONAL POWER |
描述: | 3 Watt SIP16 Single and Dual Output |
文件: | 总6页 (文件大小:1863K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 12.5kVAC/1 minute isolation
• Compact SIP16 case with >30mm pin separation
• Low4pFmax. isolationcapacitance
• Wide operating temperature range from
-40°C to +80°C at full load
DC/DC Converter
• Efficiency up to 81%
RHV3
Description
3 Watt
SIP16
Single and Dual
Output
The RHV3 is a DC/DC converter with exceptionally high 20kVDC (12.5KVAC/1 minute) isolation in a
compact SIP16 case. Input voltages can be 5, 12 or 24VDC and outputs 5V, 12V, 24V, 5V or 12V.
The operating temperature is -40°C to +80°C without derating. Applications include high vacuum
monitoring, X-Ray equipment, HVAC dust extraction systems and other high voltage industrial
applications where a very high isolation remote power supply is required.
Selection Guide
Part
Number
nom. Input
Voltage
[VDC]
Output
Voltage
[VDC]
Output
Current
[mA]
Efficiency
typ. (1)
[%]
max. Capacitive
Load (2)
[µF]
RHV3-0505S/R20
RHV3-0512S/R20
RHV3-0524S/R20
RHV3-1205S/R20
RHV3-1212S/R20
RHV3-1224S/R20
RHV3-2405S/R20
RHV3-2412S/R20
RHV3-2424S/R20
RHV3-0505D/R20
RHV3-0512D/R20
RHV3-1205D/R20
RHV3-1212D/R20
RHV3-2405D/R20
RHV3-2412D/R20
5
5
12
24
5
600
250
125
600
250
125
600
250
125
300
125
300
125
300
125
76
78
80
78
79
80
80
80
81
78
80
78
81
80
80
1000
330
100
1000
330
100
1000
330
100
680
150
680
150
680
150
5
5
12
12
12
24
24
24
5
12
24
5
12
24
5
5
12
5
12
12
24
24
12
5
12
IEC/EN62368-1 certified
IEC/EN61010-1 certified
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: The capacitive load is tested at minimum input and constant resistive load
Model Numbering
RHV3-__ __ /R20
Isolation Voltage
Output Power
Single or Dual Output
nom. Input Voltage
Output Voltage
www.recom-power.com
REV.: 0/2019
ECO-1
RHV3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Filter
Input Voltage Range
Minimum Load
capacitors
10ꢀ
0ꢀ
Internal Operating Frequency
Output Ripple and Noise (3)
20kHz
45kHz
20MHz BW
150mVp-p
200mVp-p
Notes:
Note3: Measurements are made with a 0.1µF MLCC across output (low ESR)
Efficiency vs. Load
RHV3-0505S/R20
RHV3-2424S/R20
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
ꢆutput ꢇoad ꢃꢄꢅ
ꢆutput ꢇoad ꢃꢄꢅ
RHV3-0505D/R20
RHV3-1205S/R20
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
ꢆutput ꢇoad ꢃꢄꢅ
ꢆutput ꢇoad ꢃꢄꢅ
www.recom-power.com
REV.: 0/2019
ECO-2
RHV3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Condition
Value
5.0ꢀ max.
low line to high line, full load
1.2ꢀ of 1.0ꢀ Vin typ.
15.0ꢀ max.
5Vin
others
Load Regulation(4)
Cross Regulation
10ꢀ to 100ꢀ load
10.0ꢀ max.
10ꢀ to 100ꢀ load
7.5ꢀ typ.
Notes:
Note4: Operation below 10ꢀ load will not harm the converter, but specifications may not be met
Tolerance Envelope
RHV3-0505S/R20
RHV3-0524S/R20
+15%
+12.5%
+10%
+8%
+5%
+5%
+0.5%
Vnom
Vnom
-1.5%
-5%
-5%
10
50
100
10
50
100
ꢀutput ꢅoad ꢂꢃꢄ
RHV3-0505D/R20
ꢀutput ꢅoad ꢂꢃꢄ
RHV3-2412D/R20
+15%
+12%
+10%
+6.6%
+5%
+5%
+1.5%
Vnom
Vnom
-1.5%
-5%
-5%
10
50
100
10
50
100
ꢀutput ꢅoad ꢂꢃꢄ
ꢀutput ꢅoad ꢂꢃꢄ
RHV3-1205S/R20
RHV3-2424S/R20
+15%
+10%
+10%
+6.5%
+5%
+1%
+5%
0%
Vnom
Vnom
-5%
-5%
10
50
100
10
50
100
ꢀutput ꢅoad ꢂꢃꢄ
ꢀutput ꢅoad ꢂꢃꢄ
www.recom-power.com
REV.: 0/2019
ECO-3
RHV3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
PROTECTIONS
Parameter
Type
Value
tested for 1 second
tested for 1 minute
20kVDC
12.5kVAC
Isolation Voltage(5)
I/P to O/P
Isolation Resistance
Isolation Capacitance
Insulation Grade
15GW min.
3.5pF typ./ 4pF max.
reinforced
Notes:
Note5:
Note6:
For repeat Hi-Pot testing, reduce the time and/or the test voltage
Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
ENVIRONMENTAL
Parameter
Condition
Value
-40°C to +80°C
+105°C
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Thermal Impedance
Operating Altitude
without derating @ natural convection 0.1m/s (see graph)
0.02ꢀ/K max.
12K/W typ.
5000m
Operating Humidity
Pollution Degree
non-condensing
5ꢀ - 95ꢀ RH max.
PD2
Vibration
MIL-STD-202G
+25°C
+80°C
13400 x 103 hours
3600 x 103 hours
MTBF
according to MIL-HDBK-217F,G.B.
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10
0
10 20 30 40 50 60 70 80 90 100110
95
ꢅmbient ꢆemperature ꢂꢇCꢄ
www.recom-power.com
REV.: 0/2019
ECO-4
RHV3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
Audio/Video, information and communication technology equipment -
Part1: Safety requirements
IEC62368-1:2014 2nd Edition
EN62368-1:2014+AC:2015
WD-SE-R-190305-A0
Safety requirements for electrical equipment for measurement, control
and laboratory use - Part 1: General requirements
IEC61010:2010
EN61010:2010
WD-SE-R-190305-B0
RoHS 2
RoHS 2011/65/EU + AM2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment –
Emission Requirements
refer to “EMC Filtering Suggestions”
EN55032, Class B
Information technology equipment - Immunity characteristics - Limits
and methods of measurement
EN55024:2010 + A1:2015
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Air: 2, 4, 8kV, Contact: 2, 4kV
3V/m
IEC61000-4-2:2009, Criteria A
IEC61000-4-3:2006+A2:2010, Criteria A
IEC61000-4-4:2012, Criteria A
DC Power Port: 0.5kV, 1kV
DC Power (Output) Port: 0.5kV
DC Power (Output) Port: 3V
50Hz, 1A/m
Surge Immunity
IEC61000-4-5:2014+A1:2017, Criteria A
IEC61000-4-6:2013+C1:2015, Criteria A
IEC61000-4-8:2010, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
EMC Filtering Suggestions according to EN55032
Single Output
Dual Output
L1
L1
+Vin
ꢂꢁout
+Vin
-Vin
ꢂꢁout
+Vin
-Vin
+Vout
+Vin
+Vout
Com
Com
C1
C1
-Vout
-Vin
-Vout
-Vin
ꢀꢁout
ꢀꢁout
Component List Class B
nom. Input Voltage
5VDC, 12VDC, 24VDC
C1
L1
10µF, 50VDC MLCC
18µH choke RLS-226
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
case
PCB
Value
black plastic, (UL94V-0)
FR4, (UL94V-0)
Material
potting
epoxy, (UL94V-0)
Package Dimension (LxWxH)
Weight
45.0 x 15.0 x 17.0mm
19.7g typ.
continued on next page
REV.: 0/2019
www.recom-power.com
ECO-5
RHV3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
Dimension Drawing (mm)
Pinning Information
Pin # Single
Dual
+Vin
-Vin
embossed logo
1
2
+Vin
-Vin
45.0
ꢀ5.0
14
15
16
-Vout
no pin
+Vout
-Vout
Com
+Vout
Marking
Tolerance:
xx.x= 0.5mm
xx.xx= 0.25mm
0.ꢀ0
0.ꢀ0
0.25
0.5
Recommended Footprint Details
ꢀ ꢁ
ꢀꢂꢀꢄꢀꢃ
ꢅottom ꢆieꢇ
ꢈop ꢆieꢇ
ꢀ ꢁ
ꢀꢂꢀꢄꢀꢃ
3.45
ꢀ2 x 2.54 = 30.48
2.54
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
Packaging Quantity
tube
520.0 x 26.9 x 17.9mm
10pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
5ꢀ - 95ꢀ RH max.
non-condensing
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 0/2019
ECO-6
相关型号:
©2020 ICPDF网 联系我们和版权申明