RP30-4805SF [RECOM]
30 Watt Single & Dual Output;型号: | RP30-4805SF |
厂家: | RECOM INTERNATIONAL POWER |
描述: | 30 Watt Single & Dual Output |
文件: | 总8页 (文件大小:562K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 2:1 Wide Input Voltage Range
• 1.6kVDC Isolation
• UL Certified
Features
DC/DC Converter
• Efficiency up to 91%
• Six-Sided Continuous Shield
• No Minimum Load Required
Regulated
Converters
RP30-F
Description
30 Watt
The RP30-F series DC/DC converters are designed to meet to UL 60950-1 and to cUL60950-1. This
makes them ideal for all telecom and industrial applications where approved safety standards are
required. The industry standard 2” x 1” package meets military standards for thermal shock and
vibration tolerance.
2“x1“Package
Single & Dual
Output
Selection Guide
Part Number
Input
Output
Output
Current
[mA]
Input(1) Efficiency(1) Max. Capacitive
Voltage Range Voltage
Current
[mA]
typ.
[%]
Load(2)
[µF]
[VDC]
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
9-18
[VDC]
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
5
12
15
5
12
15
5
RP30-123.3SF(3,4)
RP30-1205SF(3,4)
RP30-1212SF(3,4)
RP30-1215SF(3,4)
RP30-243.3SF(3,4)
RP30-2405SF(3,4)
RP30-2412SF(3,4)
RP30-2415SF(3,4)
RP30-483.3SF(3,4)
RP30-4805SF(3,4)
RP30-4812SF(3,4)
RP30-4815SF(3,4)
RP30-1205DF(3,4)
RP30-1212DF(3,4)
RP30-1215DF(3,4)
RP30-2405DF(3,4)
RP30-2412DF(3,4)
RP30-2415DF(3,4)
RP30-4805DF(3,4)
RP30-4812DF(3,4)
RP30-4815DF(3,4)
8000
6000
2500
2000
8000
6000
2500
2000
8000
6000
2500
2000
3000
1250
1000
3000
1250
1000
3000
1250
1000
2588
2874
2809
2809
1264
1389
1374
1374
632
694
687
687
2874
2874
2874
1389
1404
1389
694
85
87
89
89
87
90
91
91
87
90
91
91
87
87
87
90
89
90
90
88
89
20000
14400
3000
2000
20000
14400
3000
2000
20000
14400
3000
2000
3000
2000
1300
3000
2000
1300
3000
2000
1300
9-18
9-18
18-36
18-36
18-36
36-75
36-75
36-75
12
15
710
702
Notes:
Note1: Typical value at nominal input voltage and full load.
Note2: Test by minimum Vin and constant resistor load.
E196683
UL60950-1 Certified
Model Numbering
RP30-__ __ _F/_ _
Package(4)
Control Logic(3)
Input Voltage
Output Voltage
Single or Dual
Ordering Examples
RP30-2405SF = 24V Input, 5V Output, Positive Logic CTRL pin fitted
RP30-4812DF/N-HC = 48V Input, 12V Output, Negative Logic CTRL pin fitted, Heat-sink fitted
Notes:
Note3: no suffix for CTRL function with Positive Logic (1=ON, 0=OFF)
add “N” for CTRL function with Negative Logic (0=ON, 1=OFF)
Note4: add suffix -HC for premounted Heat-sink and clips
www.recom-power.com
REV.: 1/2016
PD-1
RP30-F
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
nom. Vin = 12V
nom. Vin = 24V
nom. Vin = 48V
9VDC
18VDC
36VDC
12VDC
24VDC
48VDC
18VDC
36VDC
75VDC
Input Voltage Range
DC-DC ON
DC-DC OFF
9VDC
18VDC
36VDC
Vin = 12V
Vin = 24V
Vin = 48V
8VDC
16VDC
32VDC
DC-DC ON
DC-DC OFF
Under Voltage Lockout (UVLO)
DC-DC ON
DC-DC OFF
Input Filter
Pi-Type
Input Reflected Ripple Current(5)
nominal Vin and full load
20mAp-p
Vin = 12V, 100ms max.
Vin = 24V, 100ms max.
Vin = 48V, 100ms max.
25VDC
50VDC
100VDC
Input Surge Voltage
Power up
Remote ON/OFF
30ms
30ms
Start-up time
Operating Frequency Range
Minimum Load
387kHz
0%
430kHz
473kHz
measured by 20Mhz bandwidth 3.3Vout, 5Vout
with a 1µF/50V MLCC 12Vout, 15Vout
100mVp-p
150mVp-p
Ripple and Noise
DC-DC ON
Positive Logic
Open or 3.0V < Vr < 12V
Short or 0V < Vr < 1.2V
DC-DC OFF
Remote ON/OFF(6)
DC-DC ON
Negative Logic
Short or 0V < Vr < 1.2V
Open or 3.0V < Vr < 12V
DC-DC OFF
DC-DC OFF
DC-DC ON
3mA
Input current of Remote pin (CTRL)
-0.5mA
0.5mA
Notes:
Note5: Simulated source impedance of 12µH. 12µH inductor in series with +Vin.
Note6: The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin pin.
RP30-1205SF
Efficiency vs. Output Current
Efficiency vs. Input Voltage
95
90
85
80
75
70
65
95
90
85
80
75
70
65
60
55
50
45
9Vin
12Vin
18Vin
40
10
9
10
11
12
13
14
15
16
17
18
20
30
40
50
60
70
80
90
100
Input Voltage [VDC]
Output Current [%]
continued on next page
REV.: 1/2016
PD-2
www.recom-power.com
RP30-F
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
Series
RP30-2405SF
Efficiency vs. Output Current
Efficiency vs. Input Voltage
95
95
90
85
80
75
70
65
90
85
80
75
70
65
60
55
18Vin
24Vin
36Vin
50
45
40
18
20
22
24
26
28
30
32
34
36
10
20
30
40
50
60
70
80
90
100
Output Current [%]
Input Voltage [VDC]
RP30-4805SF
Efficiency vs. Output Current
Efficiency vs. Input Voltage
95
90
85
80
75
70
65
60
55
50
45
95
90
85
80
75
70
65
36Vin
48Vin
75Vin
40
10
40
20
30
50
60
70
80
90
100
36
40
44
48
52
56
60
64
68
72
75
Output Current [%]
Input Voltage [VDC]
REGULATIONS
Parameter
Output Voltage Accuracy
Voltage Adjustability
Condition
Value
1%
Single Output
10%
0.2%
Line Voltage Regulation
low line to high line at full load
Single
Dual
0.5%
1.0%
Load Voltage Regulation
no load to full load
Cross Regulation
asymmetrical 25%<>100% load
25% load step change
5%
Transient Response recovery time
250µs
External Output Trimming
Output Voltage Trimming
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using
external trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for
chosing these trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to
work out the resis tor required or use a variable resistor to set the output voltage.
Output can be externally trimmed by using the method shown below.
Trim up
Trim down
6
5
6
R
U
R
D
4
continued on next page
REV.: 1/2016
www.recom-power.com
PD-3
RP30-F
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
Series
RP30-xx3.3SF
Trim up
Vout =
RU =
1
2
3
4
5
6
7
8
9
10
%
3.333
57.93
3.366
26.16
3.399
15.58
3.432
10.28
3.465
7.11
3.498
4.99
3.531
3.48
3.564
2.34
3.597
1.46
3.63
0.75
Volts
KOhms
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
%
3.267
69.47
3.234
31.23
3.201
18.49
3.168
12.12
3.135
8.29
3.102
5.74
3.069
3.92
3.036
2.56
3.003
1.50
2.97
0.65
Volts
KOhms
RP30-xx05SF
Trim up
1
2
3
4
5
6
7
8
9
10
%
Vout =
5.05
5.10
16.58
5.15
9.92
5.20
6.58
5.25
4.59
5.30
3.25
5.35
2.30
5.4
1.59
5.45
1.03
5.50
0.59
Volts
KOhms
RU =
36.57
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
%
4.95
45.53
4.90
20.61
4.85
12.31
4.80
8.15
4.75
5.66
4.70
4.00
4.65
2.81
4.60
1.92
4.55
1.23
4.50
0.68
Volts
KOhms
RP30-xx12SF
Trim up
1
2
3
4
5
6
7
8
9
10
%
Vout =
RU =
12.12
12.24
165.95
12.36
98.64
12.48
64.98
12.60
44.78
12.72
31.32
12.84
21.70
12.96
14.49
13.08
8.88
13.20
4.39
Volts
KOhms
367.91
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
%
11.88
460.99
11.76
207.95
11.64
123.60
11.52
81.42
11.40
56.12
11.28
39.25
11.16
27.20
11.04
18.16
10.92
11.13
10.8
5.51
Volts
KOhms
RP30-xx15SF
Trim up
1
2
3
4
5
6
7
8
9
10
%
Vout =
RU =
15.15
15.3
15.45
106.06
15.60
68.80
15.75
46.44
15.90
31.53
16.05
20.88
16.20
12.90
16.35
6.69
16.50
1.72
Volts
KOhms
404.18
180.59
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
%
14.85
499.82
14.70
223.41
14.55
131.27
14.40
85.20
14.25
57.56
14.10
39.14
13.95
25.97
13.80
16.10
13.65
8.42
13.50
2.282
Volts
KOhms
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
Continuous, automatic recovery
3.3Vout
5Vout
12Vout
15Vout
3.9VDC
6.2VDC
15VDC
18VDC
Over Voltage Protection (OVP)
Over Load Protection (OLP)
Zener Diode Clamp
% of Iout rated
150% typ.
115°C typ.
Over Temperature Protection (OTP)
I/P to O/P
I/P to O/P to case
1.6kVDC/1 minute
1.6kVDC/1 minute
Isolation Voltage
Isolation Resistance
Isolation Capacitance
500VDC
1GΩ min.
1500pF max.
Notes:
Note8: This power module is not internally fused. An input line fuse must always be used.
PD-4
REV.: 1/2016
www.recom-power.com
RP30-F
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
Series
ENVIRONMENTAL
Parameter
Condition
Value
without derating
with derating
-40°C o +74°C
-40°C to +97°C
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
+105°C
0.02%/°C max.
Natural convection (20LFM)
Natural convection (20LFM) with Heat-sink
12°C/Watt
10°C/Watt
Thermal Impedance
Operating Humidity
Thermal Shock
Vibration
5% - 95% RH
MIL-STD-810F
MIL-STD-810F
MIL-HDBK-217F
Bellcore TR-NWT-000332(9)
1453 x 103 hours
3173 x 103 hours
MTBF
Derating Graph(10)
RP30-2415SF
RP30-2415SF with Heat-sink
100
80
100
80
60
40
20
0
60
40
20
0
-40 -20
0
20 40
60
80 100 120
97
-40 -20
0
20 40
60
80 100 120
75 97
74
Ambient Temperature [°C]
Ambient Temperature [°C]
Notes:
Note9: BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment)
MIL-HDBK-217F Notice2 @ TA= 25°C, Full load (Ground, Benign, controlled environment)
Note10:Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
UL60950-1 1st. Ed.: 2003
C22.2 No. 60950 1st. Ed.: 2003
UL General Safety
E196683
EMC Compliance
EMI Standard(11)
Condition
with external filter
Standard / Criterion
EN55022, Class A or B
ESD
Air 8kV and Contact 6kC
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
Radiated Immunity
Fast Transient(12)
Surge(12)
10 V/m
2kV
1kV
Conducted Immunity
10 Vr.m.s
continued on next page
REV.: 1/2016
www.recom-power.com
PD-5
RP30-F
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
Series
Notes:
Note12: The standard modues meet EMI Class A or Class B with external components, see filter suggestions below.
Note13: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter
capacitor Recom suggests: 12VDC & 24VDC input Nippon chemi-con KY series, 330µF/50V
48VDC input Nippon chemi-con KY series, 220µF/100V
EMI Filtering Class A
C2
C3
Fuse
Fuse
+V
OUT
+V
OUT
+V
IN
+V
IN
Input
Input
DC
DC
C1
C2
COM
DC
DC
-V
OUT
-V
OUT
-V
IN
-V
IN
C3
C4
C4
C4
MODEL
C1
C2/C3/C4
RP30-12xxSF
RP30-12xxDF
10µF/25V
1812 MLCC
1000pF/2kV
1808 MLCC
RP30-24xxSF
RP30-24xxDF
4.7µF/50V
1812 MLCC
1000pF/2kV
1808 MLCC
RP30-48xxSF
RP30-48xxDF
2.2µF/100V
1812 MLCC
1000pF/2kV
1808 MLCC
EMI Filtering Class B
C4
L1
L1
Fuse
+VOUT
+V
IN
Input
DC
C1
C3
C2
DC
-VOUT
-V
IN
C5
C6
C4
L1
L1
Fuse
+VOUT
+V
IN
Input
DC
C1
C3
C2
COM
DC
-VOUT
-V
IN
C5
C6
continued on next page
REV.: 1/2016
PD-6
www.recom-power.com
RP30-F
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
Series
MODEL
C1/C2/C3
C4/C5/C6
L1
L2
CMC: 33.3µH
ref.: WE 744842932 ref.: WE 744290560
CMC: 55µH
RP30-12xxSF
RP30-12xxDF
10µF/25V
1812 MLCC
1000pF/2kV
1808 MLCC
ref.: CMC-09
ref.: CMC-10
CMC: 33.3µH
ref.: WE 744842932 ref.: WE 744290560
CMC: 55µH
RP30-24xxSF
RP30-24xxDF
4.7µF/50V
1812 MLCC
1000pF/2kV
1808 MLCC
ref.: CMC-09
ref.: CMC-10
CMC: 33.3µH
ref.: WE 744842932 ref.: WE 744290560
CMC: 55µH
RP30-48xxSF
RP30-48xxDF
2.2µF/100V
1812 MLCC
1000pF/2kV
1808 MLCC
ref.: CMC-09
ref.: CMC-10
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Case
Base
Nickel coated copper
FR4 PCB
Material
Potting
Epoxy (UL94-V0)
without Heat-sink
with Heat-sink
50.8 x 25.4 x 10.2mm
56.8 x 25.4 x 16.8mm
Package Dimensions (LxWxH)
Package Weight
without Heat-sink
with Heat-sink
30.5g
41.39g
Dimension Drawing (mm)
50.8
25.4
Ø1.00
45.72
4
1
Pin Connections
2
Bottom View
5
Pin #
Single
+Vin
Dual
+Vin
-Vin
1
2
3
4
5
6
3
-Vin
6
CTRL
+Vout
-Vout
Trim
CTRL
+Vout
Com
Dimension Drawing (mm) with Heat-sink
50.0
-Vout
Pin Pitch Tolerance 0.25 mm
Pin Dimension Tolerance 0.1mm
Tolerance: X.X 0.5mm
Top View
Heat-sink
X.XX 0.25mm
1.40
1.30
25.4
Ø1.0
56.8
www.recom-power.com
REV.: 1/2016
PD-7
RP30-F
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
Series
PACKAGING INFORMATION
Parameter
Type
Value
without Heat-sink Tube
with Heat-sink Tray
9pcs.
20pcs.
Packaging Quantity
Storage Temperature Range
Storage Humidity
-55°C to +125°C
5% - 95% RH
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PD-8
REV.: 0/2015
www.recom-power.com