RP30-4815SEW [RECOM]
POWERLINE - DC/DC - CONVERTER; 电力线 - DC / DC - 转换器型号: | RP30-4815SEW |
厂家: | RECOM INTERNATIONAL POWER |
描述: | POWERLINE - DC/DC - CONVERTER |
文件: | 总3页 (文件大小:271K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
POWERLINE - DC/DC-Converter
EW-Ser. 30W, 1.6 kV Isolation, 4:1 Wide Input Range (Single Output)
Features
● Output Current up to 8A
● High Efficiency up to 88%
● Standard Package,
50.8 mm x 25.4 mm x 10.2 mm
● Fixed Switching Frequency
● 30 Watts max. Output Power
● 4:1 Wide Input Voltage Range
● Six-Sided Continuous Shield
Selection Guide 1.8V, 2.5V, 3.3V, 5V, 12V and 15V Input Types
Part Number
Input
Range
Output
Voltage
Output
Current
Input Current
(see note 5)
Efficiency
(see note 6)
Max.
Capacitive
Load
(VDC)
10-40
10-40
10-40
10-40
10-40
10-40
18-75
18-75
18-75
18-75
18-75
18-75
(VDC)
1.8
2.5
3.3
5
(mA)
8000
8000
6000
6000
2500
2000
8000
8000
6000
6000
2500
2000
(mA)
789
(%)
80
82
86
87
87
88
81
83
87
88
87
88
(µF)
RP30-241.8SEW
RP30-242.5SEW
RP30-243.3SEW
RP30-2405SEW
RP30-2412SEW
RP30-2415SEW
RP30-481.8SEW
RP30-482.5EW
RP30-483.3SEW
RP30-4805SEW
RP30-4812SEW
RP30-4815SEW
65000
33000
19500
10200
3300
1068
1006
1506
1506
1488
390
12
15
1100
1.8
2.5
3.3
5
65000
33000
19500
10200
3300
527
497
744
12
753
15
744
1100
RP30-243.3SEW: Derating and Efficiency Curves, External Output Trimming
Derating Curve without Heat-Sink
Efficiency vs Input Voltage
External Output Trimming
125
88
87
86
85
84
83
82
81
80
79
78
77
7
100
75
Trim
Up
8
6
50
Natural Convection
Trim
Down
25
0
-40-25-10 0
50 60 70 80 90 100
10
15
20
25
30
35
40
Ambient Temperature Range (°C)
Input Voltage (V)
Derating Curve with Heat-Sink
Efficiency vs Output Load
125
100
75
88
87
86
85
84
83
82
81
80
75
70
65
50
Natural Convection
25
0
-40-25-10 0
50 60 70 80 90 100
1
2
3
4
5
6
Ambient Temperature Range (°C)
Output Load (A)
PO 60
August 2002
www.recom-international.com
POWERLINE - DC/DC-Converter
EW-Ser. 30W, 1.6 kV Isolation, 4:1 Wide Input Range (Single Output)
Specifications (typical at nominal input and 25°C unless otherwise noted)
Output Power
30W max.
1ꢀ
Voltage Accuracy (full Load and nominal Vin)
Voltage Adjustability
10ꢀ
Minimum Load
0ꢀ
Line Regulation (LL-HL at FL)
0.5ꢀ
Load Regulation (10ꢀ to 100ꢀ FL)
Ripple and Noise, 20MHz BW (measured with a 104pF/50V MLCC)
0.5ꢀ
75mVp-p
Temperature Coefficient
0.02ꢀ/°C max.
300µsec
Transient Response Recovery Time (25ꢀ load step change)
Over Voltage Protection (zener diode clamp):
1.8V Output
2.5V Output
3.3V Output
5V Output
12V Output
15V Output
3.0V
3.6V
3.9V
6.2V
15V
18V
Over Load Protection (0ꢀ of full load at nominal Vin)
Short Circuit Protection
150ꢀ typ.
Hiccup, Automatic Recovery
Input Voltage Range
24V types nominal input
48V types nominal input
10-40VDC
18-75VDC
Under Voltage Lockout
24V Input
DC-DC ON
10VDC
8VDC
18VDC
16VDC
DC-DC OFF
DC-DC ON
DC-DC OFF
48V Input
Input Filter
L-C Type
Input Surge Voltage
100 ms max.
24V Input
48V Input
50VDC
100VDC
Input Reflected Ripple (see note 1)
Nominal Vin and full load
150mAp-p
25ms
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF (see note 2)
(Positive logic)
DC-DC ON
DC-DC OFF
Nominal Vin
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
3mA
Remote off Input Current
Isolation Voltage
1600VDC
109 Ω
Isolation Resistance
Isolation Capacitance
Switching Frequency
Designed to Meet Safety Standard
Case Material
1000pF
300kHz
UL 1950, EN60950
Nickel-Coated Copper
Non-conducted Black Plastic
Epoxy (UL94-V0)
Base Material
Potting Material
Weight
48g (1.69 oz)
Dimensions
50.8 x 40.6 x 10.2 mm
1.315 x 106 Hours
-40°C to +85°C (with derating)
continued on next page
MTBF (see note 3)
Operating Temperature Range
www.recom-international.com
August 2002
PO 61
POWERLINE - DC/DC-Converter
EW-Ser. 30W, 1.6 kV Isolation, 4:1 Wide Input Range (Single Output)
Specifications continued (typical at nominal input and 25°C unless otherwise noted)
Maximum Case Temperature
+100°C
Storage Temperature Range
-55°C to +105°C
Thermal Impedance (see note 4)
Natural convection
10°C/Watt
Natural convection with heat-sink
8.24°C/Watt
Thermal Shock
Vibration
MIL-STD-810D
10-55Hz, 2G, ꢀ0 Min. along X, Y and Z
5% to 95% RH
Relative Humidity
Conducted Emissions
Radiated Emissions
Conducted Immunity
Radiated Immunity
Surge
EN55022
Level A
EN55022
Level A
EN61000-4-6
EN61000-4-ꢀ
EN61000-4-5
EN61000-4-4
EN61000-4-2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Fast Transient
ESD Air
Perf. Criteria 2
Perf. Criteria 2
Notes:
1. Simulated source impedance of 12uH, 12uH inductor in series with +Vin.
2. The ON/OFF control function. There is positiv logic (standard) and negative logic (option).
The pin voltage is referenced to negative input. To order negative logic ON-OFF control
add the suffix ‘N’ (Ex: RPꢀ0-2405SEWN)
ꢀ. BELLCORE TR-NWT-000ꢀꢀ2. Case I: 50% Stress, Temperature at 40°C
(Ground fixed and controlled environment).
4. Heat sink is optional and P/N: 7G-0011A.
5. Maximum value at nominal input voltage and full load.
6. Typical value at nominal input voltage and full load.
Package Style and Pinning (mm)
40.60
15.20
17.80
5.10
10.20
Pin Connections
4
2
1
Pin #
Single
+Vin
–Vin
dia.
1.0
1
2
4
5
6
7
8
Ctrl
No Pin
+Vout
–Vout
Trim
45.70
Bottom
View
50.10
Pin Pitch Tolerance 0.ꢀ5 mm
8
7
6
5
5.6
10.20
10.20
12.70
17.80
PO 62
August 2002
www.recom-international.com