IMBR20200C [RECTRON]
SCHOTTKY BARRIER RECTIFIER;型号: | IMBR20200C |
厂家: | RECTRON SEMICONDUCTOR |
描述: | SCHOTTKY BARRIER RECTIFIER |
文件: | 总5页 (文件大小:312K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
IMBR2045C
THRU
IMBR20200C
SCHOTTKY BARRIER RECTIFIER
VOLTAGE RANGE 45 to 200 Volts CURRENT 20.0
FEATURES
* Low switching noise
* Low forward voltage drop
* Low thermal resistance
* High current capability
* High switching capability
* High surge capabitity
* High reliability
ITO-220
.201(5.1)
.154(3.9)
.150(3.8)
.102(2.6)
.421(10.7)
.382(9.7)
MECHANICAL DATA
.128(3.25)
.085(2.15)
.140(3.56)
.083(2.10)
ꢀ &DVHꢁꢂ,7RꢃꢄꢄꢅꢂPROGHGꢂSODVWLF
* Epoxy: Device has UL flammability classification 94V-O
* Lead: MIL-STD-202Emethod 208C guaranteed
* Mounting position: Any
.626(15.9)
.567(14.4)
.177 (4.5)
.122 (3.1)
.126(3.2)
.083(2.1)
.071(1.8)
.055(1.4)
.559(14.2)
.492(12.5)
.071(1.8)
.055(1.4)
.031(0.8)
.016(0.4)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 oC ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.031(0.8)
.016 (0.4)
.116(2.95)
.071(1.80)
Dimensions in inches and (millimeters).
O
MAXIMUM RATINGS (@ T
A
=25 C unless otherwise noted)
IMBR2060C
IMBR20150C
150
IMBR20200C
SYMBOL
IMBR2045C
45
IMBR20100C
UNITS
RATINGS
100
70
VRRM
VRMS
VDC
200
140
Volts
Volts
Volts
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
60
42
105
32
45
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at Derating Case Temperature
200
100
20
60
150
IO
Amps
Amps
A2S
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
IFSM
130
I2
t
Typical Current Squared Time
70
R
R
2.0
J C
J A
θ
θ
Typical Thermal Resistance (Note 1)
0C/W
40
TJ
TSTG
0 C
0 C
Operating Temperature Range
Storage Temperature Range
-55 to + 150
-55 to + 150
O
ELECTRICAL CHARACTERISTICS(@T
A
=25 C unless otherwise noted)
IMBR20100C
.85
IMBR20150C
IMBR20200C
.95
IMBR20150C
IMBR20200C
.75
CHARACTERISTICS
SYMBOL
VF
UNITS
Volts
Maximum Instantaneous Forward Voltage at 10.0A DC
.90
0.1
.65
@TA = 25oC
Maximum Average Reverse Current
mA
mA
0.2
IR
at Rated DC Blocking Voltage
@TA = 150oC
100
NOTES : 1. Thermal Resistance : Heat-sink mounted.
2. Suffix “A” = Common Anode.
2019-11/47
REV :
O
3. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
4. "ROHS compliant".
(IMBR2045C THRU IMBR20200C)
RATING AND CHARACTERISTICS CURVES
1000
100
10
24
T
=150 OC
A
20
16
12
8
1.0
T
=25 O
C
A
0.1
4
0.01
0
20
40
60
80
100
120
140
CASE TEMPERATURE, (OC)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
FIG.2 MAXIMUM REVERSE
CHARACTERISTICS
50
130
100
At rated TL
8.3mS Single Half Sine-Wave
JEDEC Method
IMBR2060C
IMBR2045C
10
70
50
IMBR20200C
IMBR20150C
40
30
20
1.0
0.1
IMBR20100C
T
= 25 OC
J
Pulse width=300
1% Duty Cycle
S
10
0.4
1.3
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.4
MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
MAXIMUM INSTANTANEOUS FORWARD
CHARACTERISTICS
FIG.3
5(&7521
ꢀꢁ ,QWHUQDOꢂ&LUFXLWꢂ
ꢃꢁ 0DUNLQJꢂRQꢂWKHꢂERG\
3ODQWꢀꢁꢀFRGHꢀ
<HDUꢀ±ꢀFRGHꢀ
ꢂ<ꢃꢀ/DVWꢀGLJLWꢀRIꢀ\HDUꢀꢄꢀ
ꢀ ꢀ $ꢃꢅꢆꢇꢆꢈ%ꢃꢅꢆꢇꢇ««ꢉꢀ
:HHNꢀ±ꢀFRGHꢀ
9ꢂ ꢂ ;ꢂ ꢂ ;ꢂ ꢂ ;
5HFWURQꢀ/RJRꢀ
I M B R
2 0 X X
ꢂ&ꢂ ꢂ
˄::ꢃꢆꢇaꢊꢅ
˅
3DUWꢀ1Rꢋꢀ
9ROWDJHꢁFRGHꢀ
45-----45V
ꢀ ꢀ ꢀ ꢀ
60-----60V
ꢀ ꢀ ꢀ ꢀ
100-----100V
150-----150V
ꢀ ꢀ ꢀ ꢀ
200-----200V
ꢄꢁ ,WHPVꢂPDUNHGꢂRQꢂWKHꢂLQQHUꢂER[ꢂDQGꢂFDUWRQ
ꢄꢁꢀꢂ2QꢂWKHꢂER[ꢂꢅIRUꢂ±&ꢆꢂ
&86720(5ꢂ
7<3(
/27ꢂ12ꢁꢂ
48$17,7<ꢂ
4ꢁ$ꢁ
'$7(ꢂ
ꢄꢁꢃ 2QꢂWKHꢂFDUWRQꢂ
&86720(5ꢂ
7<3(
48$17,7<ꢂ
/27ꢂ12ꢁꢂ
5(0$5.ꢂ
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
TUBE PACK
INNER BOX SIZE
(mm)
CARTON SIZE
(mm)
EA PER CARTON
4,000
PACKAGE
EA PER BOX
2,000
WEIGHT(Kg)
11.80
PACKING CODE
-C
(I)TO-220/TO-220(A)
550*140*92
572*308*120
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.
相关型号:
©2020 ICPDF网 联系我们和版权申明