SF5 [RECTRON]
SURFACE MOUNT FAST RECOVERY RECTIFIER VOLTAGE RANGE 50 to 600 Volts CURRENT 1.0 Ampere; 表面装载快速恢复整流电压范围50到600伏特电流1.0安培型号: | SF5 |
厂家: | RECTRON SEMICONDUCTOR |
描述: | SURFACE MOUNT FAST RECOVERY RECTIFIER VOLTAGE RANGE 50 to 600 Volts CURRENT 1.0 Ampere |
文件: | 总5页 (文件大小:419K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SF1
THRU
SF5
SURFACE MOUNT FAST RECOVERY RECTIFIER
VOLTAGE RANGE 50 to 600 Volts CURRENT 1.0 Ampere
FEATURES
* Fast switching
* Low leakage
* Low forward voltage drop
* High current capability
* High currenf surge
* High reliability
SOD-123F
MECHANICAL DATA
* Epoxy: Device has UL flammability classification 94V-O
* Mounting position: Any
.114 (2.9)
.106 (2.7)
.077 (1.95)
.069 (1.75)
* Weight: 0.016 gram
.035 (0.90)
.028 (0.70)
.008 (0.20)
.053 (1.35)
.047 (1.20)
.030 (0.75)
.022 (0.55)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 oC ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.150 (3.8)
.142 (3.6)
Dimensions in inches and (millimeters)
O
MAXIMUM RATINGS (@ T
A
=25 C unless otherwise noted)
RATINGS
SYMBOL
SF1
50
SF2
100
SF3
200
SF4
400
SF5
UNITS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
V
Volts
Volts
Volts
600
420
600
RRM
70
V
35
50
140
200
280
400
RMS
100
Maximum DC Blocking Voltage
V
DC
Maximum Average Forward Rectified Current
I
1.0
20
Amps
Amps
at T = 55oC
O
A
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
I
FSM
R
R
32
150
θJA
0C/W
Typical Thermal Resistance (Note 4)
θJL
Typical Junction Capacitance (Note 2)
C
15
pF
0C
J
Operating and Storage Temperature Range
T , T
-55 to + 150
J
STG
O
ELECTRICAL CHARACTERISTICS(@T
A
=25 C unless otherwise noted)
CHARACTERISTICS
SYMBOL
SF1
SF2
SF3
1.3
UNITS
Volts
SF4
SF5
Maximum Instantaneous Forward Voltage at 1.0A DC
Maximum DC Reverse Current
V
F
µAmps
µAmps
2.0
at Rated DC Blocking Voltage T = 25oC
A
I
R
Maximum Full Load Reverse Current Full Cycle Average,
100
150
.375” (9.5mm) lead length at T = 55oC
L
Maximum Reverse Recovery Time (Note 1)
trr
250
nSec
2006-12
NOTES : 1. Reverse Recovery Test Conditions: IF = 0.5A, IR = -1.0A, IRR = -0.25A
2. Measured at 1 MH and applied reverse voltage of 4.0 volts
Z
3. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
4. Thermal Resistance : Mounted on PCB.
RATING AND CHARACTERISTICS CURVES ( SF1 THRU SF5 )
trr
+0.5A
50 Ω
NONINDUCTIVE
10 Ω
NONINDUCTIVE
( - )
PULSE
GENERATOR
(NOTE 2)
D.U.T
0
( + )
25 Vdc
(approx)
( - )
-0.25A
1
( + )
OSCILLOSCOPE
(NOTE 1)
NON-
INDUCTIVE
NOTES: 1 Rise Time = 7ns max. Input Impedance =
1 megohm. 22pF.
-1.0A
2. Rise Time = 10ns max. Source Impedance =
50 ohms.
1cm
SET TIME BASE FOR 50/100 ns/cm
FIG.1 TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
1.0
0.8
100
60
40
20
10
T
= 100 OC
A
0.6
0.4
6
4
T
= 25 OC
2
1
A
0.6
0.4
Single Phase
Half Wave 60Hz
Resistive or
0.2
0
Inductive Load
0.2
0.1
0
25
50
75
100
125
150
175
0
20
40
60
80
100
120
140
AMBIENT TEMPERATURE, (OC)
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.2 TYPICAL FORWARD CURRENT
DERATING CURVE
FIG.3 TYPICAL REVERSE
CHARACTERISTICS
RATING AND CHARACTERISTICS CURVES ( SF1 THRU SF5 )
20
10
20
10
8.3ms Single Half Sine-Wave
(JEDED Method)
T
= 25 OC
J
3.0
1.0
5
0.3
0.1
3
2
0.03
0.01
Pulse Width=300uS
1% Duty Cycle
1
1
5
10
50
100
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
NUMBER OF CYCLES AT 60Hz
FIG.4 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
200
100
60
40
20
10
T
= 25 OC
J
6
4
2
1
0.1 0.2
0.4
1.0
2
4
10
20
40
100
REVERSE VOLTAGE, (V)
FIG.6 TYPICAL JUNCTION CAPACITANCE
Mounting Pad Layout
0.030 MIN.
(0.75 MIN.)
0.035MIN.
(0.90 MIN.)
0.165
(4.19) REF
Dimensions in inches and (millimeters)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.
©2020 ICPDF网 联系我们和版权申明